Thermostats
3100 Series
Hermetically sealed. UL &/or CSA. Tight tolerances & differentials. Pre-set & tamper proof
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
The 3100 Series consists of a single pole, single throw switch activated by a snap-action bimetal disc. Temperature calibrations are pre-set at the factory and each unit is 100% thermally and mechanically inspected. It is available to open or close on temperature rise. The case is laser welded to form a hermetically-sealed steel housing with a glass-to-metal seal at the terminal junction. It is manufactured and tested to meet or exceed critical commercial and industrial specifications.
Features
- Hermetically sealed
- Tight tolerances
- Tight differentials
Potential Applications
- Computers
- Medical electronics
- Power supplies
- Industrial controls
- Test equipment
- Infotech
Operating Characteristics
- Humidity
- MIL-STD-202, Method 106
- Operating Temperature
- -29 °C to 260 °C [-20 °F to 500 °F]
Technical Specifications
- Thermostat Environmental Exposure Range
- -62 °C to 288 °C [-80 °F to 550 °F]
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.050 Ohm
- Insulation Resistance
- MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
Features
- Seal Type
- MIL-STD-202, Method 112; Cond. 1x10-5
Operating Characteristics
- Humidity
- MIL-STD-202, Method 106
- Operating Temperature
- -29 °C to 260 °C [-20 °F to 500 °F]
Technical Specifications
- Thermostat Environmental Exposure Range
- -62 °C to 288 °C [-80 °F to 550 °F]
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.050 Ohm
- Insulation Resistance
- MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
Features
- Seal Type
- MIL-STD-202, Method 112; Cond. 1x10-5
- Humidity : MIL-STD-202, Method 106
- Thermostat Environmental Exposure Range : -62 °C to 288 °C [-80 °F to 550 °F]
- Thermostat Contact Resistance : MIL-STD-202, Method 307; 0.050 Ohm
- Operating Temperature : -29 °C to 260 °C [-20 °F to 500 °F]
- Insulation Resistance : MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
- Dielectric Strength : MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
- Seal Type : MIL-STD-202, Method 112; Cond. 1x10-5
Data Sheet
Manuals and Guides
Brochure
Technical Note
Application Note
eBook
Please sign in to view part numbers available for purchase based on your account Sign In