Gas Sensors

Midi

Overview
Specifications

Options

  • Brand
    • Honeywell
  • Series Name
    • CiTiceL 4

Technical Specifications

  • Baseline Offset (clean air)
    • <± 2 ppm
  • Long-Term Output Drift
    • < 5% per Year
  • Position Sensitivity
    • None
  • Maximum Overload
    • 20,000 ppm
  • Gases Detected
    • Carbon Monoxide (CO)
  • Sensitivity
    • 70 ± 15 nA/ppm
  • Orientation
    • Any
  • Resolution
    • < 1 ppm

Applications & Compatibility

  • Recommended Load Resistor
    • 5 Ohm

Operating Characteristics

  • Operating Pressure Range
    • 800 to 1200 mbar
  • Operating Humidity Range
    • 15 to 95% RH (Non-Condensing)
  • Expected Operating Life
    • 3 Years
  • Storage Temperature
    • 0 to 20°C

Material Specifications

  • Outer Body Material
    • Noryl N110
  • Contact Material
    • Gold Over Nickel Plated Brass
  • Casing Material
    • Noryl N110
  • Body Material
    • Noryl N110
  • Pin Material
    • Gold Over Nickel Plated Brass

Features

  • Operating Principle
    • 3-Electrode Electrochemical
  • Repeatability
    • <± 2% of Signal
  • Nominal Range
    • 0 to 10,000 ppm

Features & Benefits

  • Features & Benefits
    • Extended Operating Range
    • Fast Response and Recovery Time
    • Low Long-Term Output Drift
    • Superior Long-Term Performance at Temperature and Humidity Extremes

Dimensions & Weight

  • Weight range
    • 5 g
  • Dimensions
    • 20.2 mm x 20.2 mm x 20.6 mm

Electrical Specifications

  • Bias Voltage
    • Not Required

Options

  • Brand
    • Honeywell
  • Series Name
    • CiTiceL 4

Technical Specifications

  • Baseline Offset (clean air)
    • <± 2 ppm
  • Long-Term Output Drift
    • < 5% per Year
  • Position Sensitivity
    • None
  • Maximum Overload
    • 20,000 ppm
  • Gases Detected
    • Carbon Monoxide (CO)
  • Sensitivity
    • 70 ± 15 nA/ppm
  • Orientation
    • Any
  • Resolution
    • < 1 ppm

Applications & Compatibility

  • Recommended Load Resistor
    • 5 Ohm

Operating Characteristics

  • Operating Pressure Range
    • 800 to 1200 mbar
  • Operating Humidity Range
    • 15 to 95% RH (Non-Condensing)
  • Expected Operating Life
    • 3 Years
  • Storage Temperature
    • 0 to 20°C

Material Specifications

  • Outer Body Material
    • Noryl N110
  • Contact Material
    • Gold Over Nickel Plated Brass
  • Casing Material
    • Noryl N110
  • Body Material
    • Noryl N110
  • Pin Material
    • Gold Over Nickel Plated Brass

Features

  • Operating Principle
    • 3-Electrode Electrochemical
  • Repeatability
    • <± 2% of Signal
  • Nominal Range
    • 0 to 10,000 ppm

Features & Benefits

  • Features & Benefits
    • Extended Operating Range
    • Fast Response and Recovery Time
    • Low Long-Term Output Drift
    • Superior Long-Term Performance at Temperature and Humidity Extremes

Dimensions & Weight

  • Weight range
    • 5 g
  • Dimensions
    • 20.2 mm x 20.2 mm x 20.6 mm

Electrical Specifications

  • Bias Voltage
    • Not Required
  • Brand : Honeywell
  • Baseline Offset (clean air) : <± 2 ppm
  • Recommended Load Resistor : 5 Ohm
  • Operating Pressure Range : 800 to 1200 mbar
  • Operating Humidity Range : 15 to 95% RH (Non-Condensing)
  • Expected Operating Life : 3 Years
  • Long-Term Output Drift : < 5% per Year
  • Position Sensitivity : None
  • Storage Temperature : 0 to 20°C
  • Outer Body Material : Noryl N110
  • Operating Principle : 3-Electrode Electrochemical
  • Features & Benefits : Extended Operating Range|Fast Response and Recovery Time|Low Long-Term Output Drift|Superior Long-Term Performance at Temperature and Humidity Extremes
  • Maximum Overload : 20,000 ppm
  • Contact Material : Gold Over Nickel Plated Brass
  • Casing Material : Noryl N110
  • Gases Detected : Carbon Monoxide (CO)
  • Repeatability : <± 2% of Signal
  • Nominal Range : 0 to 10,000 ppm
  • Body Material : Noryl N110
  • Weight range : 5 g
  • Pin Material : Gold Over Nickel Plated Brass
  • Bias Voltage : Not Required
  • Series Name : CiTiceL 4
  • Sensitivity : 70 ± 15 nA/ppm
  • Orientation : Any
  • Resolution : < 1 ppm
  • Dimensions : 20.2 mm x 20.2 mm x 20.6 mm
Showing 1 to 5 of 5 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
2118B0106
Flammable Gases LEL Midi Sensor 3AC (0-100%LEL) Zellpell
2118B0106
Flammable Gases LEL Midi Sensor 3AC (0-100%LEL) Zellpell
2123B1013
SILANE TESTED ASSY
2123B1013
SILANE TESTED ASSY
2123B1060
Surecell PH2
2123B1060
Surecell PH2
2124B1010
SURECELL MIN ACID HCL (H) TESTED
2124B1010
SURECELL MIN ACID HCL (H) TESTED
32341488-001
iseries-Evaluation kit
32341488-001
iseries-Evaluation kit
Feedback