RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs)

Product Overview:

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.

The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

Features & Benefits:

  • Faster response time - Thanks to the sample flow-through design
  • Reduce maintenance cost - Easy to remove sensor module in hazardous locations without using of tools
  • No false alarms - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution

Quick Specs:

  • Digital Smart Sensor Technology
  • Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm
  • Operates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output
  • Graphic display and LED light status indicator for fault and alarm conditions

Fire and Gas Consultancy Services

Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Overview

  • Brand
    • RAE
  • Warranty
    • 1 Year for the Pump
    • 2 Years for the Housing and Electronics

Features

  • Sub-Category
    • Gas Detection Sensors & Transmitters
    • Gas Detection Sensors & Transmitters
  • Alarm Included
    • Yes
  • Display Type
    • LCD
  • Display Included
    • Yes
  • Features & Benefits
    • Accurate Readings
    • Continuous VOC Monitoring in Hazardous and Non-Hazardous Locations
    • Easy to Remove Sensor Module in Hazardous Locations without Use of Tools
    • Fast Speed of Response Provides Earliest Warning
    • Reduced Life Cost
  • Filter Included
    • Yes
  • Sampling Pump Included
    • Yes
  • Wireless Technology
    • Mesh
  • Replacement Parts
    • DigiPID Sensor Module, Lamp
  • Vibration
    • Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12

Dimensions & Weight

  • Weight range
    • 3.5 Kg
  • Inlet Connector Thread
    • 0.75 in
  • Dimension
    • L: 10.1 in W: 7.9 in H: 4.2 in

Technical Specifications

  • Humidity Range
    • 0 to 95% RH (Non-Condensing)
  • Number of Analog Outputs
    • 1
  • Analog Outputs
    • 4 to 20 mA
  • Analog Output Connection
    • 3-Wire
  • Calibration Procedures
    • Zero and Span Low, Zero, Span Low and Span High
  • Calibration Points
    • 2
  • Calibration Gas
    • Isobutylene
  • Calibration
    • Automatic, Fresh Air
  • Display Viewing Area
    • 128 x 64
  • Filter Type
    • Coalescing
  • Filter Required
    • Yes
  • Number of Digital Communication Ports
    • 1
  • Relay Rated Load
    • 30 VDC, 2A
  • Relay Circuit Resting Configuration
    • NO, NC
  • Sampling Pump Location
    • Internal
  • Sensor Mechanism
    • PID
  • Sensing Method
    • PID
  • Operating Life
    • 2
  • Number of Signal Outputs
    • 1
  • Number of Relay Outputs
    • 3
  • Number of Contacts
    • 3
  • Mounting
    • Wall
  • Maximum Pressure
    • 110 kPa
  • Drift
    • 10
  • Default Relay Activation
    • Low, High, Fault
  • Spectral Sensitivity
    • Infrared: 0.7 to 3.5 Micrometers (SS4-A and SS4-AS Only)
    • Ultraviolet: 185 to 260 Nanometers Wide Band
    • Visible: 400 to 700 Nanometers (SS4-A and SS4-AS only)
  • Signal Output
    • 3-Wire Signal Output
  • Sensitivity
    • Adjustable Between 60 ft, 45 ft, 30 ft, and 15 ft to a 1 sq.ft Gasoline Fire
  • Mounting Thread
    • 3/4 in NPT
  • Field of View
    • 120° Cone of Vision

Operating Characteristics

  • Minimum Temperature
    • -20°C

Electrical Specifications

  • Analog Output Signal Current
    • 4 to 20 mA
  • Maximum Operating Current
    • 210 mA
  • Maximum Analog Input Supply Current
    • 110
  • Analog Output Signal Voltage
    • 0.5 to 2.5 V
  • Power Requirement
    • 24 VDC
  • Power Consumption
    • < 5W
  • Operating Voltage
    • 10 to 28 VDC

Material Specifications

  • Material
    • 316 Stainless Steel
  • Filter Insert Material
    • PTFE

Standards & Certifications

  • Ingress Protection
    • IP65

Applications & Compatibility

  • Application
    • Acetone, Xylene, Phenol in Medical, Pathology, Histology Lab
    • Air Quality
    • Ammonia in Industry
    • Benzene in Refinery Analyser Shelters
    • Heat Transfer Fluids
    • Methyl Ethyl Ketone in Paint Spray Booths
    • Solvent and Chemicals Storage
    • Toluene in Printing
    • Toluene or Ammonia in Semi-Conductor Plants
    • Vinyl Chloride in Chemical Manufacturing

Overview

  • Brand
    • RAE
  • Warranty
    • 1 Year for the Pump
    • 2 Years for the Housing and Electronics

Features

  • Sub-Category
    • Gas Detection Sensors & Transmitters
    • Gas Detection Sensors & Transmitters
  • Alarm Included
    • Yes
  • Display Type
    • LCD
  • Display Included
    • Yes
  • Features & Benefits
    • Accurate Readings
    • Continuous VOC Monitoring in Hazardous and Non-Hazardous Locations
    • Easy to Remove Sensor Module in Hazardous Locations without Use of Tools
    • Fast Speed of Response Provides Earliest Warning
    • Reduced Life Cost
  • Filter Included
    • Yes
  • Sampling Pump Included
    • Yes
  • Wireless Technology
    • Mesh
  • Replacement Parts
    • DigiPID Sensor Module, Lamp
  • Vibration
    • Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12

Dimensions & Weight

  • Weight range
    • 3.5 Kg
  • Inlet Connector Thread
    • 0.75 in
  • Dimension
    • L: 10.1 in W: 7.9 in H: 4.2 in

Technical Specifications

  • Humidity Range
    • 0 to 95% RH (Non-Condensing)
  • Number of Analog Outputs
    • 1
  • Analog Outputs
    • 4 to 20 mA
  • Analog Output Connection
    • 3-Wire
  • Calibration Procedures
    • Zero and Span Low, Zero, Span Low and Span High
  • Calibration Points
    • 2
  • Calibration Gas
    • Isobutylene
  • Calibration
    • Automatic, Fresh Air
  • Display Viewing Area
    • 128 x 64
  • Filter Type
    • Coalescing
  • Filter Required
    • Yes
  • Number of Digital Communication Ports
    • 1
  • Relay Rated Load
    • 30 VDC, 2A
  • Relay Circuit Resting Configuration
    • NO, NC
  • Sampling Pump Location
    • Internal
  • Sensor Mechanism
    • PID
  • Sensing Method
    • PID
  • Operating Life
    • 2
  • Number of Signal Outputs
    • 1
  • Number of Relay Outputs
    • 3
  • Number of Contacts
    • 3
  • Mounting
    • Wall
  • Maximum Pressure
    • 110 kPa
  • Drift
    • 10
  • Default Relay Activation
    • Low, High, Fault
  • Spectral Sensitivity
    • Infrared: 0.7 to 3.5 Micrometers (SS4-A and SS4-AS Only)
    • Ultraviolet: 185 to 260 Nanometers Wide Band
    • Visible: 400 to 700 Nanometers (SS4-A and SS4-AS only)
  • Signal Output
    • 3-Wire Signal Output
  • Sensitivity
    • Adjustable Between 60 ft, 45 ft, 30 ft, and 15 ft to a 1 sq.ft Gasoline Fire
  • Mounting Thread
    • 3/4 in NPT
  • Field of View
    • 120° Cone of Vision

Operating Characteristics

  • Minimum Temperature
    • -20°C

Electrical Specifications

  • Analog Output Signal Current
    • 4 to 20 mA
  • Maximum Operating Current
    • 210 mA
  • Maximum Analog Input Supply Current
    • 110
  • Analog Output Signal Voltage
    • 0.5 to 2.5 V
  • Power Requirement
    • 24 VDC
  • Power Consumption
    • < 5W
  • Operating Voltage
    • 10 to 28 VDC

Material Specifications

  • Material
    • 316 Stainless Steel
  • Filter Insert Material
    • PTFE

Standards & Certifications

  • Ingress Protection
    • IP65

Applications & Compatibility

  • Application
    • Acetone, Xylene, Phenol in Medical, Pathology, Histology Lab
    • Air Quality
    • Ammonia in Industry
    • Benzene in Refinery Analyser Shelters
    • Heat Transfer Fluids
    • Methyl Ethyl Ketone in Paint Spray Booths
    • Solvent and Chemicals Storage
    • Toluene in Printing
    • Toluene or Ammonia in Semi-Conductor Plants
    • Vinyl Chloride in Chemical Manufacturing
  • Brand : RAE
  • Sub-Category : Gas Detection Sensors & Transmitters|Gas Detection Sensors & Transmitters
  • Weight range : 3.5 Kg
  • Humidity Range : 0 to 95% RH (Non-Condensing)
  • Minimum Temperature : -20°C
  • Alarm Included : Yes
  • Number of Analog Outputs : 1
  • Analog Outputs : 4 to 20 mA
  • Analog Output Signal Current : 4 to 20 mA
  • Analog Output Connection : 3-Wire
  • Calibration Procedures : Zero and Span Low, Zero, Span Low and Span High
  • Calibration Points : 2
  • Calibration Gas : Isobutylene
  • Calibration : Automatic, Fresh Air
  • Inlet Connector Thread : 0.75 in
  • Display Viewing Area : 128 x 64
  • Display Type : LCD
  • Display Included : Yes
  • Features & Benefits : Accurate Readings|Continuous VOC Monitoring in Hazardous and Non-Hazardous Locations|Easy to Remove Sensor Module in Hazardous Locations without Use of Tools|Fast Speed of Response Provides Earliest Warning|Reduced Life Cost
  • Filter Type : Coalescing
  • Filter Required : Yes
  • Filter Included : Yes
  • Material : 316 Stainless Steel
  • Filter Insert Material : PTFE
  • Number of Digital Communication Ports : 1
  • Relay Rated Load : 30 VDC, 2A
  • Relay Circuit Resting Configuration : NO, NC
  • Sampling Pump Location : Internal
  • Sampling Pump Included : Yes
  • Sensor Mechanism : PID
  • Sensing Method : PID
  • Operating Life : 2
  • Maximum Operating Current : 210 mA
  • Maximum Analog Input Supply Current : 110
  • Analog Output Signal Voltage : 0.5 to 2.5 V
  • Wireless Technology : Mesh
  • Replacement Parts : DigiPID Sensor Module, Lamp
  • Number of Signal Outputs : 1
  • Number of Relay Outputs : 3
  • Number of Contacts : 3
  • Mounting : Wall
  • Maximum Pressure : 110 kPa
  • Ingress Protection : IP65
  • Drift : 10
  • Default Relay Activation : Low, High, Fault
  • Warranty : 1 Year for the Pump|2 Years for the Housing and Electronics
  • Vibration : Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
  • Spectral Sensitivity : Infrared: 0.7 to 3.5 Micrometers (SS4-A and SS4-AS Only)|Ultraviolet: 185 to 260 Nanometers Wide Band|Visible: 400 to 700 Nanometers (SS4-A and SS4-AS only)
  • Signal Output : 3-Wire Signal Output
  • Sensitivity : Adjustable Between 60 ft, 45 ft, 30 ft, and 15 ft to a 1 sq.ft Gasoline Fire
  • Power Requirement : 24 VDC
  • Power Consumption : < 5W
  • Operating Voltage : 10 to 28 VDC
  • Mounting Thread : 3/4 in NPT
  • Field of View : 120° Cone of Vision
  • Dimension : L: 10.1 in W: 7.9 in H: 4.2 in
  • Application : Acetone, Xylene, Phenol in Medical, Pathology, Histology Lab|Air Quality|Ammonia in Industry|Benzene in Refinery Analyser Shelters|Heat Transfer Fluids|Methyl Ethyl Ketone in Paint Spray Booths|Solvent and Chemicals Storage|Toluene in Printing|Toluene or Ammonia in Semi-Conductor Plants|Vinyl Chloride in Chemical Manufacturing
Data Sheet
Name
Description
File Size
Date
Size
RAEGuard 2 PID Data Sheet
application/pdf 406.17 KB
7/15/2021
406.17 KB
Manuals and Guides
Name
Description
File Size
Date
Size
RAEGuard 2 PID User Guide Rev-R ENG
application/pdf 3.76 MB
7/7/2022
3.76 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
7/15/2021
820.7 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Certificate
Name
Description
File Size
Date
Size
RAEGuard 2 PID EU Declaration of Conformity
application/pdf 201.56 KB
2/4/2022
201.56 KB
RAEGuard 2 PID ATEX EC-Type Examiniation Certificate
application/pdf 964.3 KB
7/15/2021
964.3 KB
RAEGuard 2 (FGM 2xxx) EU Declaration of Conformity
application/pdf 201.56 KB
1/6/2022
201.56 KB
RAEGuard 2 PID DigiPID ATEX CE EU Declaration of Conformity
application/pdf 399.16 KB
11/8/2023
399.16 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
RAEGuard 2 PID Intrinsic Safety Report
application/pdf 50.9 KB
7/15/2021
50.9 KB
DigiPID EU Declaration of Conformity
application/pdf 213.06 KB
2/4/2022
213.06 KB
EU & UK Declaration of Conformity RAEGuard 2
application/pdf 557.92 KB
7/25/2023
557.92 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
RAEGuard 2 PID Atex Certificate of Conformity
application/pdf 240.87 KB
11/8/2023
240.87 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Name
Description
File Size
Date
Size
RAEGuard 2 PID EU Declaration of Conformity
application/pdf 201.56 KB
2/4/2022
201.56 KB
RAEGuard 2 PID ATEX EC-Type Examiniation Certificate
application/pdf 964.3 KB
7/15/2021
964.3 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
RAEGuard 2 PID Data Sheet
application/pdf 406.17 KB
7/15/2021
406.17 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
RAEGuard 2 (FGM 2xxx) EU Declaration of Conformity
application/pdf 201.56 KB
1/6/2022
201.56 KB
RAEGuard 2 PID User Guide Rev-R ENG
application/pdf 3.76 MB
7/7/2022
3.76 MB
RAEGuard 2 PID DigiPID ATEX CE EU Declaration of Conformity
application/pdf 399.16 KB
11/8/2023
399.16 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
RAEGuard 2 PID Intrinsic Safety Report
application/pdf 50.9 KB
7/15/2021
50.9 KB
DigiPID EU Declaration of Conformity
application/pdf 213.06 KB
2/4/2022
213.06 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
EU & UK Declaration of Conformity RAEGuard 2
application/pdf 557.92 KB
7/25/2023
557.92 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
7/15/2021
820.7 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
RAEGuard 2 PID Atex Certificate of Conformity
application/pdf 240.87 KB
11/8/2023
240.87 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Showing 1 to 10 of 86 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3034-000
ASSY,FILTER (D50MMX0.22UM)
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3034-000
ASSY,FILTER (D50MMX0.22UM)
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3035-000
DigiPID external dust pre-filter
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3035-000
DigiPID external dust pre-filter
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
050-0000-005
DigiPID lamp, 10.6 ev, 12
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
050-0000-005
DigiPID lamp, 10.6 ev, 12
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
050-0061-001
LAMP,10.6EV,12,13X40,MARK2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
050-0061-001
LAMP,10.6EV,12,13X40,MARK2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
081-0018-C00
KIT,AIR DRYING PRE-FILTER,CHINA
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
081-0018-C00
KIT,AIR DRYING PRE-FILTER,CHINA
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
411-0024-026
TUBING,TYGON,332X732X116
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
411-0024-026
TUBING,TYGON,332X732X116
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
430-0009-025
SCREW PKG 25,MACHINE,256X316,(PCB MOUNT
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
430-0009-025
SCREW PKG 25,MACHINE,256X316,(PCB MOUNT
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
430-0314-000
SCREW,M4X12,SET,SOCKET,HEX,SS,NC,GB80-85
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
430-0314-000
SCREW,M4X12,SET,SOCKET,HEX,SS,NC,GB80-85
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg