光离子化检测器 (PID)
UltraRAE 3000 + PID9.8
The most advanced wireless handheld VOC monitor with parts per million measurement
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Dimension & Weight
- Weight
- 738 gram
- Weight range
- 738 g gram
- Instrument Size
- 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
Brand
- Brand
- Honeywell RAE Systems
Category
- Sub-Category
- Portable Handheld Compound-Specific VOC Monitor
Range
- Sensor Range
- Benzene 0 -200 ppm
- Butadiene 0-200 ppm
- VOC (0-10000ppm)- Benzene (0-200ppm)- Butadiene (0-200ppm)
- VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm
- Humidity Range
- 0 to 95% RH (Non-Condensing) percent
- Extended Range
- 0.01-10,000 ppm
Temperature
- Minimum Temperature
- -20
- -20 degree Celsius
- Maximum Temperature
- 50
- 50 degree Celsius
Features
- Alarm Included
- Yes
- Series Name
- UltraRAE 3000+ PID9.8
- Languages
- Multi-Language Support
Alarm
- Alarm Type
- Audible (95 dB)
- Audible- Visual- Vibrating
- Visual (LED)
- Alarm Settings
- Additional Diagnostic Alarm and Display Message for Low Battery and Pump Stall
- Alarm Latching with Manual Override or Automatic Reset
- High: 3 Beeps and Flashes per sec
- Low: 2 Beeps and Flashes per sec
Battery & Charging
- Battery Run Time
- 16 Hours hours
- Batteries Required
- Yes
- Batteries Included
- Yes
Calibration
- Calibration Procedures
- Calibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates
- Reflex PID Technology
- Two-Point or Three-Point Calibration for Zero and Span
- Calibration Points
- 2
- 3
Certifications
- Standards
- Europe: ATEX II 2G EEx ia IIC T4
- IECEx CSA 10.0005 Ex ia IIC/IIB GbT4
- US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D
- US and Canada: CSA- Classified as Intrinsically Safe for use in Class I- Division 1
Datalogging
- Datalogging Interval
- 1 min
- Datalogging Capable
- Yes
- Datalogging
- Standard 6 Months at 1 min Intervals
Display
- Display Viewing Area
- 28 x 43 mm
- Display Included
- Yes
Features & Benefits
- Features & Benefits
- Built-In Humidity Sensor with Automatic Temperature Controlled Sampling Time Calculation
- Cost Effective Solution and Low-Cost RAE-SepTM Tubes
- Easy Access to Lamp, Sensor and Battery in Seconds without Tools
- Highly Connectivity Capability through Multiple Wireless Module Options
- Highly Specific Readings, Combining a 9.8eV UV Lamp and RAE-Sep™ Benzene Tube
- Multi-Language Support
- Reflex PID Technology
- See-Through Sampling Probe Design for Instant Tube Breakthrough Visibility
- Versatile VOC or Benzene-Specific Modes
- • Versatile VOC or Benzene-Specific modes
Filter
- Filter Included
- No
Options
- User Options
- • Alarms latching with manual override or automatic reset
Sampling
- Sampling Pump Rate
- 400
- Sampling Pump Range
- 100 ft meter
- Sampling Pump Included
- Yes
Sensor
- Sensor Type
- Photoionization
- Sensor Mechanism
- Photoionization
- Number of Sensors Included
- 3
Warranty
- Warranty
- 1 Year for Pump, Battery, Sensor and Instrument
- 3 Years for 10.6 eV Lamp
- 3 years for 10.6 eV lamp- 6 months for
- 6 Months for 9.8 eV Lamp
Wireless
- Wireless Technology
- MESH- BLE
- Wireless Enabled
- Yes
Standards & Certifications
- Ingress Protection
- IP65
Additional Specifications
- Gas Type
- VOC- Benzene- Butadiene
- Decibels
- 95 decibel
- Combustible
- Yes
Technical Specifications
- Wireless Range
- EchoView Host: LOS > 660 ft (200 m)
- ProRAE Guardian and RAELink3 Mesh: LOS > 330 ft (100m)
- ProRAE Guardian and RAEMesh Reader: LOS > 660 ft (200m)
- Up to 15 ft (5m) for BLE
- Wireless Network
- Mesh RAE Systems Dedicated Wireless Network
- Wireless Approvals
- CE RandTTE
- FCC Part 15
- Sampling
- Internal
- Resolution
- Benzene 0.010 ppm
- Butadiene 0.010 ppm
- VOCs 0.010 ppm, 0.1 ppm, 1 ppm
- Pump Draw
- Sample from 100 ft (30m) Horizontally or Vertically
- Keypad Type
- 1 Operation and 2 Programming Keys, 1 Flashlight On/Off
- Gases Detected
- VOCS, Benzene, Butadiene
- EMC/RFI
- EMC Directive: 2004/108/EC
- EMI and ESD Test: 100 MHz to 1 GHz 30V/m, No Alarm, Contact: ±4kV, Air: ±8kV, No Alarm
- Display Graphic
- 4 Lines, 28 x 43 mm
- Direct Readout
- Battery and Shutdown Voltage
- Date and Time
- High and Low Values
- STEL and TWA
- Temperature
- VOCs as ppm by Volume (mg/m³)
- Communication and Data Download
- Download Data and Upload Instrument Set-Up From PC Through Charging Cradle or Using BLE Module and Dedicated App
- Wireless Data Transmission Through Built-In RF Modem
- Attachment
- Durable Bright Red Rubber Boot
Dimensions & Weight
- Size
- 10 in L x 3.0 in W x 2.5 in H
Electrical Specifications
- Power Source
- Battery
Material Specifications
- Housing Material
- Rubber
Applications & Compatibility
- Application
- Confined Space Entry Pre-Screening During Refinery and Plant Maintenance
- Hazardous Material Response
- Marine Spill Response
- Plant Overhaul
- Refinery Down-Stream Monitoring
Others
- Industry
- Energy
Dimension & Weight
- Weight
- 738 gram
- Weight range
- 738 g gram
- Instrument Size
- 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
Brand
- Brand
- Honeywell RAE Systems
Category
- Sub-Category
- Portable Handheld Compound-Specific VOC Monitor
Range
- Sensor Range
- Benzene 0 -200 ppm
- Butadiene 0-200 ppm
- VOC (0-10000ppm)- Benzene (0-200ppm)- Butadiene (0-200ppm)
- VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm
- Humidity Range
- 0 to 95% RH (Non-Condensing) percent
- Extended Range
- 0.01-10,000 ppm
Temperature
- Minimum Temperature
- -20
- -20 degree Celsius
- Maximum Temperature
- 50
- 50 degree Celsius
Features
- Alarm Included
- Yes
- Series Name
- UltraRAE 3000+ PID9.8
- Languages
- Multi-Language Support
Alarm
- Alarm Type
- Audible (95 dB)
- Audible- Visual- Vibrating
- Visual (LED)
- Alarm Settings
- Additional Diagnostic Alarm and Display Message for Low Battery and Pump Stall
- Alarm Latching with Manual Override or Automatic Reset
- High: 3 Beeps and Flashes per sec
- Low: 2 Beeps and Flashes per sec
Battery & Charging
- Battery Run Time
- 16 Hours hours
- Batteries Required
- Yes
- Batteries Included
- Yes
Calibration
- Calibration Procedures
- Calibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates
- Reflex PID Technology
- Two-Point or Three-Point Calibration for Zero and Span
- Calibration Points
- 2
- 3
Certifications
- Standards
- Europe: ATEX II 2G EEx ia IIC T4
- IECEx CSA 10.0005 Ex ia IIC/IIB GbT4
- US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D
- US and Canada: CSA- Classified as Intrinsically Safe for use in Class I- Division 1
Datalogging
- Datalogging Interval
- 1 min
- Datalogging Capable
- Yes
- Datalogging
- Standard 6 Months at 1 min Intervals
Display
- Display Viewing Area
- 28 x 43 mm
- Display Included
- Yes
Features & Benefits
- Features & Benefits
- Built-In Humidity Sensor with Automatic Temperature Controlled Sampling Time Calculation
- Cost Effective Solution and Low-Cost RAE-SepTM Tubes
- Easy Access to Lamp, Sensor and Battery in Seconds without Tools
- Highly Connectivity Capability through Multiple Wireless Module Options
- Highly Specific Readings, Combining a 9.8eV UV Lamp and RAE-Sep™ Benzene Tube
- Multi-Language Support
- Reflex PID Technology
- See-Through Sampling Probe Design for Instant Tube Breakthrough Visibility
- Versatile VOC or Benzene-Specific Modes
- • Versatile VOC or Benzene-Specific modes
Filter
- Filter Included
- No
Options
- User Options
- • Alarms latching with manual override or automatic reset
Sampling
- Sampling Pump Rate
- 400
- Sampling Pump Range
- 100 ft meter
- Sampling Pump Included
- Yes
Sensor
- Sensor Type
- Photoionization
- Sensor Mechanism
- Photoionization
- Number of Sensors Included
- 3
Warranty
- Warranty
- 1 Year for Pump, Battery, Sensor and Instrument
- 3 Years for 10.6 eV Lamp
- 3 years for 10.6 eV lamp- 6 months for
- 6 Months for 9.8 eV Lamp
Wireless
- Wireless Technology
- MESH- BLE
- Wireless Enabled
- Yes
Standards & Certifications
- Ingress Protection
- IP65
Additional Specifications
- Gas Type
- VOC- Benzene- Butadiene
- Decibels
- 95 decibel
- Combustible
- Yes
Technical Specifications
- Wireless Range
- EchoView Host: LOS > 660 ft (200 m)
- ProRAE Guardian and RAELink3 Mesh: LOS > 330 ft (100m)
- ProRAE Guardian and RAEMesh Reader: LOS > 660 ft (200m)
- Up to 15 ft (5m) for BLE
- Wireless Network
- Mesh RAE Systems Dedicated Wireless Network
- Wireless Approvals
- CE RandTTE
- FCC Part 15
- Sampling
- Internal
- Resolution
- Benzene 0.010 ppm
- Butadiene 0.010 ppm
- VOCs 0.010 ppm, 0.1 ppm, 1 ppm
- Pump Draw
- Sample from 100 ft (30m) Horizontally or Vertically
- Keypad Type
- 1 Operation and 2 Programming Keys, 1 Flashlight On/Off
- Gases Detected
- VOCS, Benzene, Butadiene
- EMC/RFI
- EMC Directive: 2004/108/EC
- EMI and ESD Test: 100 MHz to 1 GHz 30V/m, No Alarm, Contact: ±4kV, Air: ±8kV, No Alarm
- Display Graphic
- 4 Lines, 28 x 43 mm
- Direct Readout
- Battery and Shutdown Voltage
- Date and Time
- High and Low Values
- STEL and TWA
- Temperature
- VOCs as ppm by Volume (mg/m³)
- Communication and Data Download
- Download Data and Upload Instrument Set-Up From PC Through Charging Cradle or Using BLE Module and Dedicated App
- Wireless Data Transmission Through Built-In RF Modem
- Attachment
- Durable Bright Red Rubber Boot
Dimensions & Weight
- Size
- 10 in L x 3.0 in W x 2.5 in H
Electrical Specifications
- Power Source
- Battery
Material Specifications
- Housing Material
- Rubber
Applications & Compatibility
- Application
- Confined Space Entry Pre-Screening During Refinery and Plant Maintenance
- Hazardous Material Response
- Marine Spill Response
- Plant Overhaul
- Refinery Down-Stream Monitoring
Others
- Industry
- Energy
- Weight : 738 gram
- Brand : Honeywell RAE Systems
- Sub-Category : Portable Handheld Compound-Specific VOC Monitor
- Weight range : 738 g gram
- Instrument Size : 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
- Sensor Range : Benzene 0 -200 ppm|Butadiene 0-200 ppm|VOC (0-10000ppm)- Benzene (0-200ppm)- Butadiene (0-200ppm)|VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm
- Humidity Range : 0 to 95% RH (Non-Condensing) percent
- Extended Range : 0.01-10,000 ppm
- Minimum Temperature : -20|-20 degree Celsius
- Maximum Temperature : 50|50 degree Celsius
- Alarm Included : Yes
- Alarm Type : Audible (95 dB)|Audible- Visual- Vibrating|Visual (LED)
- Alarm Settings : Additional Diagnostic Alarm and Display Message for Low Battery and Pump Stall|Alarm Latching with Manual Override or Automatic Reset|High: 3 Beeps and Flashes per sec|Low: 2 Beeps and Flashes per sec
- Battery Run Time : 16 Hours hours
- Batteries Required : Yes
- Batteries Included : Yes
- Calibration Procedures : Calibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates|Reflex PID Technology|Two-Point or Three-Point Calibration for Zero and Span
- Calibration Points : 2|3
- Standards : Europe: ATEX II 2G EEx ia IIC T4|IECEx CSA 10.0005 Ex ia IIC/IIB GbT4|US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D|US and Canada: CSA- Classified as Intrinsically Safe for use in Class I- Division 1
- Datalogging Interval : 1 min
- Datalogging Capable : Yes
- Datalogging : Standard 6 Months at 1 min Intervals
- Display Viewing Area : 28 x 43 mm
- Display Included : Yes
- Features & Benefits : Built-In Humidity Sensor with Automatic Temperature Controlled Sampling Time Calculation|Cost Effective Solution and Low-Cost RAE-SepTM Tubes|Easy Access to Lamp, Sensor and Battery in Seconds without Tools|Highly Connectivity Capability through Multiple Wireless Module Options|Highly Specific Readings, Combining a 9.8eV UV Lamp and RAE-Sep™ Benzene Tube|Multi-Language Support|Reflex PID Technology|See-Through Sampling Probe Design for Instant Tube Breakthrough Visibility|Versatile VOC or Benzene-Specific Modes|• Versatile VOC or Benzene-Specific modes
- Filter Included : No
- User Options : • Alarms latching with manual override or automatic reset
- Sampling Pump Rate : 400
- Sampling Pump Range : 100 ft meter
- Sampling Pump Included : Yes
- Sensor Type : Photoionization
- Sensor Mechanism : Photoionization
- Number of Sensors Included : 3
- Warranty : 1 Year for Pump, Battery, Sensor and Instrument|3 Years for 10.6 eV Lamp|3 years for 10.6 eV lamp- 6 months for|6 Months for 9.8 eV Lamp
- Wireless Technology : MESH- BLE
- Wireless Enabled : Yes
- Ingress Protection : IP65
- Gas Type : VOC- Benzene- Butadiene
- Decibels : 95 decibel
- Combustible : Yes
- Wireless Range : EchoView Host: LOS > 660 ft (200 m)|ProRAE Guardian and RAELink3 Mesh: LOS > 330 ft (100m)|ProRAE Guardian and RAEMesh Reader: LOS > 660 ft (200m)|Up to 15 ft (5m) for BLE
- Wireless Network : Mesh RAE Systems Dedicated Wireless Network
- Wireless Approvals : CE RandTTE|FCC Part 15
- Size : 10 in L x 3.0 in W x 2.5 in H
- Series Name : UltraRAE 3000+ PID9.8
- Sampling : Internal
- Resolution : Benzene 0.010 ppm|Butadiene 0.010 ppm|VOCs 0.010 ppm, 0.1 ppm, 1 ppm
- Pump Draw : Sample from 100 ft (30m) Horizontally or Vertically
- Power Source : Battery
- Languages : Multi-Language Support
- Keypad Type : 1 Operation and 2 Programming Keys, 1 Flashlight On/Off
- Industry : Energy
- Housing Material : Rubber
- Gases Detected : VOCS, Benzene, Butadiene
- EMC/RFI : EMC Directive: 2004/108/EC|EMI and ESD Test: 100 MHz to 1 GHz 30V/m, No Alarm, Contact: ±4kV, Air: ±8kV, No Alarm
- Display Graphic : 4 Lines, 28 x 43 mm
- Direct Readout : Battery and Shutdown Voltage|Date and Time|High and Low Values|STEL and TWA|Temperature|VOCs as ppm by Volume (mg/m³)
- Communication and Data Download : Download Data and Upload Instrument Set-Up From PC Through Charging Cradle or Using BLE Module and Dedicated App|Wireless Data Transmission Through Built-In RF Modem
- Attachment : Durable Bright Red Rubber Boot
- Application : Confined Space Entry Pre-Screening During Refinery and Plant Maintenance|Hazardous Material Response|Marine Spill Response|Plant Overhaul|Refinery Down-Stream Monitoring
请 登录后即可查看根据您的帐户可购买的零件编号 登入