Componentes Centrais
Single-phase power supply unit 24 V DC (10 A)
Single-phase power supply unit (10 A) for the constant DC power supply of the call system in accordance with DIN VDE 0834-1: 2016-06, fulfilment of EN60601-1, 2xMOPP.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Part Number: 89954R5
Single-phase power supply unit (10 A) for the constant DC power supply of the call system in accordance with DIN VDE 0834-1: 2016-06, fulfilment of EN60601-1, 2xMOPP. UL/CSA 60601-1 (E213214) certified. Very compact design due to fully-integrated primary-clocked switching technology. Parallel-switchable and series-switchable for flexible power supply of the call system and its components. Voltage range adjustable, for adaptation to local requirements. DC-OK-Signal (LED/relay) for further interference processing in accordance with DIN VDE 0834-1: 2016-06. Fitted with "push-in" connectors for simple wiring (max. 2.5 mm2). Suitable for top-hat rail mounting in the sub-distribution.
Features
Connectors output:
- Push-In, max 2.5 mm2
- earth leakage current:
Signalling DC-OK:
- Uout > 21,5 V DC (LED)
- Uout > 21,5 V (typ.) max. 30 V/1A (relay)
Recommended circuit breaker:
- 10 A (characteristic B/C)
Switch-on current limitation:
- < 30 A, NTC
Additional information
IEC 60364-4-41 (DIN VDE 0100-410).
SELV: EN 60601-1, 2xMOPP.
EN 61558-1 /-2-16, EN 60950-1.
AAMI/ANSI ES 60601-1: 2005.
CSA C22.2 No. 60601-1 (2008).
EMC: EN 61204-3.
IEC 60601-1-2.
CE: in accordance with 2014/30/EU and 2014/35/EU.
UL: UL/CSA 60601-1 (E213214).
Operating Characteristics
- Ambient Temperature
- -25 to 70°C
- Storage Temperature
- -40 to 85°C
Dimensions & Weight
- Weight (kg)
- 1
- Dimensions
- W: 55 mm H: 127 mm D: 171 mm
Electrical Specifications
- Rated voltage (V AC)
- 230
- Rated current (A)
- 1.24
- Output current
- 10 A at 24 V (Continuous Load)
- Output Voltage
- 23 to 28.5 VDC
Technical Specifications
- Rated frequency
- 50 Hz
- Mounting
- Top-Hat Rail Mounting
Features
- Features & Benefits
- Earth Leakage Current: Uout > 21.5 VDC (LED), Uout > 21.5 V (typ.) Max. 30 V/1 A (Relay), 10 A (Characteristic B/C), < 30 A, NTC
- Max 2.5 mm²
- Push-In
Overview
- Brand
- Honeywell
Applications & Compatibility
- Application
- Constant DC Power Supply of the Call System
Others
- Industry
- Healthcare
Operating Characteristics
- Ambient Temperature
- -25 to 70°C
- Storage Temperature
- -40 to 85°C
Dimensions & Weight
- Weight (kg)
- 1
- Dimensions
- W: 55 mm H: 127 mm D: 171 mm
Electrical Specifications
- Rated voltage (V AC)
- 230
- Rated current (A)
- 1.24
- Output current
- 10 A at 24 V (Continuous Load)
- Output Voltage
- 23 to 28.5 VDC
Technical Specifications
- Rated frequency
- 50 Hz
- Mounting
- Top-Hat Rail Mounting
Features
- Features & Benefits
- Earth Leakage Current: Uout > 21.5 VDC (LED), Uout > 21.5 V (typ.) Max. 30 V/1 A (Relay), 10 A (Characteristic B/C), < 30 A, NTC
- Max 2.5 mm²
- Push-In
Overview
- Brand
- Honeywell
Applications & Compatibility
- Application
- Constant DC Power Supply of the Call System
Others
- Industry
- Healthcare
- Ambient Temperature : -25 to 70°C
- Weight (kg) : 1
- Storage Temperature : -40 to 85°C
- Rated voltage (V AC) : 230
- Rated frequency : 50 Hz
- Rated current (A) : 1.24
- Output current : 10 A at 24 V (Continuous Load)
- Output Voltage : 23 to 28.5 VDC
- Mounting : Top-Hat Rail Mounting
- Industry : Healthcare
- Features & Benefits : Earth Leakage Current: Uout > 21.5 VDC (LED), Uout > 21.5 V (typ.) Max. 30 V/1 A (Relay), 10 A (Characteristic B/C), < 30 A, NTC|Max 2.5 mm²|Push-In
- Dimensions : W: 55 mm H: 127 mm D: 171 mm
- Brand : Honeywell
- Application : Constant DC Power Supply of the Call System
Data Sheet
Por favor faça login para ver os números de peças disponíveis para compra com base na sua conta Entrar
Filters
Por favor faça login para ver os números de peças disponíveis para compra com base na sua conta Entrar