Hermetically sealed. Tight tolerances & differentials. Pre-set & tamper proof. SPST contacts. Mounting brackets, terminals
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Features
- Hermetically sealed
- Tight tolerances
- Tight differentials
- Space qualified
- Hi-Rel
Potential Applications
- Satellites
- International space station
- Space shuttle
- Spacecraft
Others
- Insulation Resistance
- MIL-STD-202, Method 302; 500 MOhm
- Vibration
- MIL-STD-202, Method 204; 30 G : MIL-STD-202, Method 214; 50 G
- Shock
- MIL-STD-202, Method 213; 750 G
- Thermostat Environmental Exposure Range
- -65 °C to 177 °C [-85 °F to 350 °F]
- Acceleration Range/Limits
- MIL-STD-202, Method 212; 20 G
- Thermal Shock
- MIL-STD-202, Method 107; Cond. B
- Salt Spray
- MIL-STD-202, Method 101; Cond. B
- Operating temperature
- -51 °C to 163 °C [-60 °F to 325 °F]
- Agency Approvals and Standards
- MIL-PRF-24236
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.025 Ohm max.
- Humidity
- MIL-STD-202, Method 106
- Seal Type
- MIL-STD-202, Method 112; Cond. C
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac
Others
- Insulation Resistance
- MIL-STD-202, Method 302; 500 MOhm
- Vibration
- MIL-STD-202, Method 204; 30 G : MIL-STD-202, Method 214; 50 G
- Shock
- MIL-STD-202, Method 213; 750 G
- Thermostat Environmental Exposure Range
- -65 °C to 177 °C [-85 °F to 350 °F]
- Acceleration Range/Limits
- MIL-STD-202, Method 212; 20 G
- Thermal Shock
- MIL-STD-202, Method 107; Cond. B
- Salt Spray
- MIL-STD-202, Method 101; Cond. B
- Operating temperature
- -51 °C to 163 °C [-60 °F to 325 °F]
- Agency Approvals and Standards
- MIL-PRF-24236
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.025 Ohm max.
- Humidity
- MIL-STD-202, Method 106
- Seal Type
- MIL-STD-202, Method 112; Cond. C
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac
- Insulation Resistance : MIL-STD-202, Method 302; 500 MOhm
- Vibration : MIL-STD-202, Method 204; 30 G : MIL-STD-202, Method 214; 50 G
- Shock : MIL-STD-202, Method 213; 750 G
- Thermostat Environmental Exposure Range : -65 °C to 177 °C [-85 °F to 350 °F]
- Acceleration Range/Limits : MIL-STD-202, Method 212; 20 G
- Thermal Shock : MIL-STD-202, Method 107; Cond. B
- Salt Spray : MIL-STD-202, Method 101; Cond. B
- Operating temperature : -51 °C to 163 °C [-60 °F to 325 °F]
- Agency Approvals and Standards : MIL-PRF-24236
- Thermostat Contact Resistance : MIL-STD-202, Method 307; 0.025 Ohm max.
- Humidity : MIL-STD-202, Method 106
- Seal Type : MIL-STD-202, Method 112; Cond. C
- Dielectric Strength : MIL-STD-202, Method 301; 1250 Vac
Data Sheet
Manuals and Guides
Brochure
Technical Note
Application Note
Please sign in to view part numbers available for purchase based on your account Sign In