    Hermetically sealed. Use in severe duty applications where military device not needed

    Overview

    The 3800 Series is used where high levels of vibration and mechanical shock are common but a military device is not required. It is easily customized for use in a variety of applications.

    Features
    • Easily customized
    Potential Applications
    • Commercial aircraft
    Specifications

    Others

    • Dielectric Strength
      • MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
    • Humidity
      • MIL-STD-202, Method 106
    • Vibration
      • MIL-STD-202, Method 204; 20 G
    • Thermostat Environmental Exposure Range
      • -62 °C to 288 °C [-80 °F to 550 °F]
    • Shock
      • MIL-STD-202, Method 213; 400 G
    • Operating temperature
      • -29 °C to 260 °C [-20 °F to 500 °F]
    • Seal Type
      • MIL-STD-202, Method 112; Cond. 1x10-5
    • Thermostat Contact Resistance
      • MIL-STD-202, Method 307; 0.050 Ohm
    • Insulation Resistance
      • MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied

    Others

    • Dielectric Strength
      • MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
    • Humidity
      • MIL-STD-202, Method 106
    • Vibration
      • MIL-STD-202, Method 204; 20 G
    • Thermostat Environmental Exposure Range
      • -62 °C to 288 °C [-80 °F to 550 °F]
    • Shock
      • MIL-STD-202, Method 213; 400 G
    • Operating temperature
      • -29 °C to 260 °C [-20 °F to 500 °F]
    • Seal Type
      • MIL-STD-202, Method 112; Cond. 1x10-5
    • Thermostat Contact Resistance
      • MIL-STD-202, Method 307; 0.050 Ohm
    • Insulation Resistance
      • MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
    • Dielectric Strength : MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
    • Humidity : MIL-STD-202, Method 106
    • Vibration : MIL-STD-202, Method 204; 20 G
    • Thermostat Environmental Exposure Range : -62 °C to 288 °C [-80 °F to 550 °F]
    • Shock : MIL-STD-202, Method 213; 400 G
    • Operating temperature : -29 °C to 260 °C [-20 °F to 500 °F]
    • Seal Type : MIL-STD-202, Method 112; Cond. 1x10-5
    • Thermostat Contact Resistance : MIL-STD-202, Method 307; 0.050 Ohm
    • Insulation Resistance : MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    Precision and High Reliability Thermostats
    application/pdf 5.15 MB
    8/24/2021
    5.15 MB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    Thermostats Line Guide
    application/pdf 450.42 KB
    7/16/2021
    450.42 KB
    Precision Thermostat Selection Guide
    application/pdf 258.21 KB
    8/24/2021
    258.21 KB
    Technical Tip Bulletin - Precision Thermostat | Gold Contact Selection Guide
    application/pdf 33.28 KB
    8/24/2021
    33.28 KB
    Soldering Wire Leads on Precision Hermetic Thermostats
    application/pdf 216.61 KB
    8/24/2021
    216.61 KB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    Industrial Applications: Going Beyond Limits
    application/pdf 16.69 MB
    11/17/2022
    16.69 MB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    Industrial Product Line Card --
    application/pdf 2.24 MB
    10/25/2022
    2.24 MB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Forestry Vehicles
    application/pdf 1.05 MB
    12/20/2022
    1.05 MB
    Platform Vehicles
    application/pdf 628.05 KB
    12/20/2022
    628.05 KB
    Agricultural Vehicles
    application/pdf 1.11 MB
    4/11/2024
    1.11 MB
    Defence Ground Vehicles -
    application/pdf 872.87 KB
    6/14/2023
    872.87 KB
    Construction Vehicles -
    application/pdf 984.29 KB
    12/20/2022
    984.29 KB
    Name
    Description
    File Size
    Date
    Size
    Thermostats Line Guide
    application/pdf 450.42 KB
    7/16/2021
    450.42 KB
    Industrial Applications: Going Beyond Limits
    application/pdf 16.69 MB
    11/17/2022
    16.69 MB
    Industrial Product Line Card --
    application/pdf 2.24 MB
    10/25/2022
    2.24 MB
    Forestry Vehicles
    application/pdf 1.05 MB
    12/20/2022
    1.05 MB
    Platform Vehicles
    application/pdf 628.05 KB
    12/20/2022
    628.05 KB
    Precision Thermostat Selection Guide
    application/pdf 258.21 KB
    8/24/2021
    258.21 KB
    Agricultural Vehicles
    application/pdf 1.11 MB
    4/11/2024
    1.11 MB
    Defence Ground Vehicles -
    application/pdf 872.87 KB
    6/14/2023
    872.87 KB
    Technical Tip Bulletin - Precision Thermostat | Gold Contact Selection Guide
    application/pdf 33.28 KB
    8/24/2021
    33.28 KB
    Precision and High Reliability Thermostats
    application/pdf 5.15 MB
    8/24/2021
    5.15 MB
    Soldering Wire Leads on Precision Hermetic Thermostats
    application/pdf 216.61 KB
    8/24/2021
    216.61 KB
    Construction Vehicles -
    application/pdf 984.29 KB
    12/20/2022
    984.29 KB
    Name
    Description
    File Size
    Date
    Size
    Precision and High Reliability Thermostats
    5.15 MB
    8/24/2021
    Thermostats Line Guide
    450.42 KB
    7/16/2021
    Precision Thermostat Selection Guide
    258.21 KB
    8/24/2021
    Technical Tip Bulletin - Precision Thermostat | Gold Contact Selection Guide
    33.28 KB
    8/24/2021
    Soldering Wire Leads on Precision Hermetic Thermostats
    216.61 KB
    8/24/2021
    Industrial Applications: Going Beyond Limits
    16.69 MB
    11/17/2022
    Industrial Product Line Card --
    2.24 MB
    10/25/2022
    Forestry Vehicles
    1.05 MB
    12/20/2022
    Platform Vehicles
    628.05 KB
    12/20/2022
    Agricultural Vehicles
    1.11 MB
    4/11/2024
    Defence Ground Vehicles -
    872.87 KB
    6/14/2023
    Construction Vehicles -
    984.29 KB
    12/20/2022
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list