Thermostats
3800 Series
Hermetically sealed. Use in severe duty applications where military device not needed
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
The 3800 Series is used where high levels of vibration and mechanical shock are common but a military device is not required. It is easily customized for use in a variety of applications.
Features
- Easily customized
Potential Applications
- Commercial aircraft
Technical Specifications
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
- Thermostat Environmental Exposure Range
- -62 °C to 288 °C [-80 °F to 550 °F]
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.050 Ohm
- Insulation Resistance
- MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
Features
- Vibration
- MIL-STD-202, Method 204; 20 G
- Shock
- MIL-STD-202, Method 213; 400 G
- Seal Type
- MIL-STD-202, Method 112; Cond. 1x10-5
Operating Characteristics
- Operating Temperature
- -29 °C to 260 °C [-20 °F to 500 °F]
- Humidity
- MIL-STD-202, Method 106
Others
- Industry
- Aerospace
Technical Specifications
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
- Thermostat Environmental Exposure Range
- -62 °C to 288 °C [-80 °F to 550 °F]
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.050 Ohm
- Insulation Resistance
- MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
Features
- Vibration
- MIL-STD-202, Method 204; 20 G
- Shock
- MIL-STD-202, Method 213; 400 G
- Seal Type
- MIL-STD-202, Method 112; Cond. 1x10-5
Operating Characteristics
- Operating Temperature
- -29 °C to 260 °C [-20 °F to 500 °F]
- Humidity
- MIL-STD-202, Method 106
Others
- Industry
- Aerospace
- Dielectric Strength : MIL-STD-202, Method 301; 1250 Vac 60 Hz - Terminal to Case
- Vibration : MIL-STD-202, Method 204; 20 G
- Thermostat Environmental Exposure Range : -62 °C to 288 °C [-80 °F to 550 °F]
- Thermostat Contact Resistance : MIL-STD-202, Method 307; 0.050 Ohm
- Shock : MIL-STD-202, Method 213; 400 G
- Seal Type : MIL-STD-202, Method 112; Cond. 1x10-5
- Operating Temperature : -29 °C to 260 °C [-20 °F to 500 °F]
- Insulation Resistance : MIL-STD-202, Method 302; Cond. B - 500 MOhm - 500 Vdc applied
- Industry : Aerospace
- Humidity : MIL-STD-202, Method 106
Data Sheet
Manuals and Guides
Brochure
Application Note
eBook
Please sign in to view part numbers available for purchase based on your account Sign In
Please sign in to view part numbers available for purchase based on your account Sign In