    Oxygen sensors for medical use: compliant with European MDD (CE certification). Compliant to EU RoHS Directive 2011/65/EU. Meets ISO 80601-2-55. Designed & manufactured according to EN ISO 13485. Higher accuracy and reliability in response

    Overview

    EnviteC Cross Reference List   |   Tech Support

    From standard sensors to customized sensors: Experienced EnviteC engineers analyze customer requirements. This input is used for different standard and OEM applications, and ongoing support is provided right up to the final integration in the solution. EnviteC designs customized sensors characterized by a high degree of precision, for example with different signal levels or temperature compensation elements.

    Step into the lead-free future: With innovative technology and engineering expertise, Honeywell has developed a patent-pending, lead-free oxygen sensor series. Honeywell lead-free O2 sensors are a one-to-one, drop-in replacement - no application redesign needed. This innovation was driven by European regulations to fulfill RoHS regulatory requirements for medical applications.

    The EnviteC Medical Oxygen Sensors are intended as oxygen sensing component of an oxygen analyzer that measures oxygen concentration in breathing gas mixtures in the following applications: Sensing device for oxygen in medical ventilators, anesthesia machines, incubators, and control device of oxygen concentrators.

    EnviteC by Honeywell

    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    Data Sheet - Medical Oxygen Sensor OOM202-2
    application/pdf 466.35 KB
    9/20/2024
    466.35 KB
    Data Sheet - Medical Oxygen Sensor OOM105
    application/pdf 375.05 KB
    9/20/2024
    375.05 KB
    Data Sheet - Medical Oxygen Sensor OOM106
    application/pdf 396.67 KB
    9/20/2024
    396.67 KB
    Data Sheet - Medical Oxygen Sensor OOM202
    application/pdf 431.42 KB
    9/20/2024
    431.42 KB
    Data Sheet - Medical Oxygen Sensor OOM101
    application/pdf 380.45 KB
    9/20/2024
    380.45 KB
    Data Sheet - Medical Oxygen Sensor OOM109-LF2
    application/pdf 389.92 KB
    9/20/2024
    389.92 KB
    Data Sheet - Medical Oxygen Sensor OOM102
    application/pdf 383.78 KB
    9/20/2024
    383.78 KB
    Data Sheet - Medical Oxygen Sensor OOM201
    application/pdf 360.19 KB
    9/20/2024
    360.19 KB
    Data Sheet - Medical Oxygen Sensor OOM103-1
    application/pdf 389.73 KB
    9/20/2024
    389.73 KB
    Data Sheet - Medical Oxygen Sensor OOM109
    application/pdf 458.02 KB
    9/20/2024
    458.02 KB
    Data Sheet - Medical Oxygen Sensor OOM204
    application/pdf 401.19 KB
    9/20/2024
    401.19 KB
    Data Sheet - Medical Oxygen Sensor OOM202-2S
    application/pdf 378.51 KB
    9/20/2024
    378.51 KB
    Data Sheet - Medical Oxygen Sensor OOM103
    application/pdf 376.48 KB
    9/20/2024
    376.48 KB
    Data Sheet - Medical Oxygen Sensor OOM111
    application/pdf 337.82 KB
    9/20/2024
    337.82 KB
    Data Sheet for OOM112 Medical Oxygen Sensor
    application/pdf 356.3 KB
    10/25/2024
    356.3 KB
    Data Sheet - Medical Oxygen Sensor OOM104
    application/pdf 354.14 KB
    9/20/2024
    354.14 KB
    Data Sheet - Medical Oxygen Sensor OOM102-1
    application/pdf 388.61 KB
    9/20/2024
    388.61 KB
    Data Sheet - Medical Oxygen Sensor OOM110
    application/pdf 373.9 KB
    9/20/2024
    373.9 KB
    Data Sheet - Medical Oxygen Sensor OOM103-1M
    application/pdf 427.2 KB
    9/20/2024
    427.2 KB
    Data Sheet - Medical Oxygen Sensor OOM113
    application/pdf 305.22 KB
    10/25/2024
    305.22 KB
    Data Sheet - Medical Oxygen Sensor OOM202-1
    application/pdf 435.39 KB
    9/20/2024
    435.39 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    OOM109-X Medical Oxygen Sensor - Operating Manual
    application/pdf 105.02 KB
    8/16/2023
    105.02 KB
    OOMLF Series Medical Oxygen Sensor – Lead-Free (LF) - Operating Manual
    application/pdf 142.27 KB
    9/22/2023
    142.27 KB
    Operating manual OOM Series Medical Oxygen Sensor (except OOM109-X)
    application/pdf 88.92 KB
    5/8/2024
    88.92 KB
    Certificate
    Name
    Description
    File Size
    Date
    Size
    EC Certificate (MDD)
    application/pdf 129.43 KB
    6/26/2024
    129.43 KB
    Confirmation Letter on validity of EC Certificate (MDD)
    application/pdf 405.61 KB
    6/26/2024
    405.61 KB
    Manufacturers Declaration according to EU MDR
    application/pdf 215.73 KB
    6/26/2024
    215.73 KB
    Certificate MDSAP ISO 13485
    application/pdf 420.2 KB
    6/26/2024
    420.2 KB
    Confirmation statement about company renaming
    application/pdf 227.43 KB
    6/26/2024
    227.43 KB
    Certificate According To ISO 13485 (English)
    application/pdf 340.29 KB
    6/26/2024
    340.29 KB
    Form certificate on hygiene status and desinfection of returned product/s
    application/pdf 470.7 KB
    9/22/2021
    470.7 KB
    Form certificate on hygiene status and desinfection of returned product/s
    application/pdf 469.94 KB
    9/22/2021
    469.94 KB
    Others
    Name
    Description
    File Size
    Date
    Size
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
    application/pdf 205.2 KB
    11/24/2021
    205.2 KB
    Form details on potential safety relevant failures or events
    application/pdf 492.27 KB
    9/22/2021
    492.27 KB
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
    application/pdf 34.46 KB
    3/10/2022
    34.46 KB
    Form details on potential safety relevant failures or events
    application/pdf 495.94 KB
    9/22/2021
    495.94 KB
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
    application/pdf 211.68 KB
    11/24/2021
    211.68 KB
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
    application/pdf 35.04 KB
    3/10/2022
    35.04 KB
    Name
    Description
    File Size
    Date
    Size
    Data Sheet - Medical Oxygen Sensor OOM202-2
    application/pdf 466.35 KB
    9/20/2024
    466.35 KB
    EC Certificate (MDD)
    application/pdf 129.43 KB
    6/26/2024
    129.43 KB
    Confirmation Letter on validity of EC Certificate (MDD)
    application/pdf 405.61 KB
    6/26/2024
    405.61 KB
    Manufacturers Declaration according to EU MDR
    application/pdf 215.73 KB
    6/26/2024
    215.73 KB
    Certificate MDSAP ISO 13485
    application/pdf 420.2 KB
    6/26/2024
    420.2 KB
    Confirmation statement about company renaming
    application/pdf 227.43 KB
    6/26/2024
    227.43 KB
    Certificate According To ISO 13485 (English)
    application/pdf 340.29 KB
    6/26/2024
    340.29 KB
    OOM109-X Medical Oxygen Sensor - Operating Manual
    application/pdf 105.02 KB
    8/16/2023
    105.02 KB
    OOMLF Series Medical Oxygen Sensor – Lead-Free (LF) - Operating Manual
    application/pdf 142.27 KB
    9/22/2023
    142.27 KB
    Data Sheet - Medical Oxygen Sensor OOM105
    application/pdf 375.05 KB
    9/20/2024
    375.05 KB
    Data Sheet - Medical Oxygen Sensor OOM106
    application/pdf 396.67 KB
    9/20/2024
    396.67 KB
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
    application/pdf 205.2 KB
    11/24/2021
    205.2 KB
    Form details on potential safety relevant failures or events
    application/pdf 492.27 KB
    9/22/2021
    492.27 KB
    Data Sheet - Medical Oxygen Sensor OOM202
    application/pdf 431.42 KB
    9/20/2024
    431.42 KB
    Data Sheet - Medical Oxygen Sensor OOM101
    application/pdf 380.45 KB
    9/20/2024
    380.45 KB
    Data Sheet - Medical Oxygen Sensor OOM109-LF2
    application/pdf 389.92 KB
    9/20/2024
    389.92 KB
    Data Sheet - Medical Oxygen Sensor OOM102
    application/pdf 383.78 KB
    9/20/2024
    383.78 KB
    Data Sheet - Medical Oxygen Sensor OOM201
    application/pdf 360.19 KB
    9/20/2024
    360.19 KB
    Operating manual OOM Series Medical Oxygen Sensor (except OOM109-X)
    application/pdf 88.92 KB
    5/8/2024
    88.92 KB
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
    application/pdf 34.46 KB
    3/10/2022
    34.46 KB
    Data Sheet - Medical Oxygen Sensor OOM103-1
    application/pdf 389.73 KB
    9/20/2024
    389.73 KB
    Data Sheet - Medical Oxygen Sensor OOM109
    application/pdf 458.02 KB
    9/20/2024
    458.02 KB
    Form certificate on hygiene status and desinfection of returned product/s
    application/pdf 470.7 KB
    9/22/2021
    470.7 KB
    Data Sheet - Medical Oxygen Sensor OOM204
    application/pdf 401.19 KB
    9/20/2024
    401.19 KB
    Data Sheet - Medical Oxygen Sensor OOM202-2S
    application/pdf 378.51 KB
    9/20/2024
    378.51 KB
    Form details on potential safety relevant failures or events
    application/pdf 495.94 KB
    9/22/2021
    495.94 KB
    Data Sheet - Medical Oxygen Sensor OOM103
    application/pdf 376.48 KB
    9/20/2024
    376.48 KB
    Form certificate on hygiene status and desinfection of returned product/s
    application/pdf 469.94 KB
    9/22/2021
    469.94 KB
    Data Sheet - Medical Oxygen Sensor OOM111
    application/pdf 337.82 KB
    9/20/2024
    337.82 KB
    Data Sheet for OOM112 Medical Oxygen Sensor
    application/pdf 356.3 KB
    10/25/2024
    356.3 KB
    Data Sheet - Medical Oxygen Sensor OOM104
    application/pdf 354.14 KB
    9/20/2024
    354.14 KB
    Data Sheet - Medical Oxygen Sensor OOM102-1
    application/pdf 388.61 KB
    9/20/2024
    388.61 KB
    Data Sheet - Medical Oxygen Sensor OOM110
    application/pdf 373.9 KB
    9/20/2024
    373.9 KB
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
    application/pdf 211.68 KB
    11/24/2021
    211.68 KB
    Data Sheet - Medical Oxygen Sensor OOM103-1M
    application/pdf 427.2 KB
    9/20/2024
    427.2 KB
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
    application/pdf 35.04 KB
    3/10/2022
    35.04 KB
    Data Sheet - Medical Oxygen Sensor OOM113
    application/pdf 305.22 KB
    10/25/2024
    305.22 KB
    Data Sheet - Medical Oxygen Sensor OOM202-1
    application/pdf 435.39 KB
    9/20/2024
    435.39 KB
    Name
    Description
    File Size
    Date
    Size
    Data Sheet - Medical Oxygen Sensor OOM202-2
    466.35 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM105
    375.05 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM106
    396.67 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM202
    431.42 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM101
    380.45 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM109-LF2
    389.92 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM102
    383.78 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM201
    360.19 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM103-1
    389.73 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM109
    458.02 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM204
    401.19 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM202-2S
    378.51 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM103
    376.48 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM111
    337.82 KB
    9/20/2024
    Data Sheet for OOM112 Medical Oxygen Sensor
    356.3 KB
    10/25/2024
    Data Sheet - Medical Oxygen Sensor OOM104
    354.14 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM102-1
    388.61 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM110
    373.9 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM103-1M
    427.2 KB
    9/20/2024
    Data Sheet - Medical Oxygen Sensor OOM113
    305.22 KB
    10/25/2024
    Data Sheet - Medical Oxygen Sensor OOM202-1
    435.39 KB
    9/20/2024
    OOM109-X Medical Oxygen Sensor - Operating Manual
    105.02 KB
    8/16/2023
    OOMLF Series Medical Oxygen Sensor – Lead-Free (LF) - Operating Manual
    142.27 KB
    9/22/2023
    Operating manual OOM Series Medical Oxygen Sensor (except OOM109-X)
    88.92 KB
    5/8/2024
    EC Certificate (MDD)
    129.43 KB
    6/26/2024
    Confirmation Letter on validity of EC Certificate (MDD)
    405.61 KB
    6/26/2024
    Manufacturers Declaration according to EU MDR
    215.73 KB
    6/26/2024
    Certificate MDSAP ISO 13485
    420.2 KB
    6/26/2024
    Confirmation statement about company renaming
    227.43 KB
    6/26/2024
    Certificate According To ISO 13485 (English)
    340.29 KB
    6/26/2024
    Form certificate on hygiene status and desinfection of returned product/s
    470.7 KB
    9/22/2021
    Form certificate on hygiene status and desinfection of returned product/s
    469.94 KB
    9/22/2021
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
    205.2 KB
    11/24/2021
    Form details on potential safety relevant failures or events
    492.27 KB
    9/22/2021
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
    34.46 KB
    3/10/2022
    Form details on potential safety relevant failures or events
    495.94 KB
    9/22/2021
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIb)
    211.68 KB
    11/24/2021
    EC-Conformity Statement for Medical Respiratory Gas Sensors - Oxygen Sensors OOM (Class IIa)
    35.04 KB
    3/10/2022
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    DE800.A.2
    OXYGEN SENSOR
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    DE800.A.2
    OXYGEN SENSOR
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    DE800.V.1.NF
    OXYGEN SENSOR
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    DE800.V.1.NF
    OXYGEN SENSOR
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    DE800.V.2
    OXYGEN SENSOR
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    DE800.V.2
    OXYGEN SENSOR
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0013
    OOM101 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20 mV, load 300 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0013
    OOM101 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20 mV, load 300 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0014
    OOM201 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0014
    OOM201 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 14 mV ... 20.7 mV (Dual Cathode), load 600 Ohms; electrical interface: gold-plated slip rings; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0015
    OOM103 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3-pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0015
    OOM103 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3-pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0016
    OOM103-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0016
    OOM103-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 500 000 % volume oxygen hours; output: 9 mV ... 13 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0019
    OOM102 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3 pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0019
    OOM102 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3 pin (Molex® 22-11-1031); meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0020
    OOM102-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0020
    OOM102-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 9 mV ... 14 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0021
    OOM202-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 13 mV ... 16 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors
    E01-00-0021
    OOM202-1 Medical Oxygen Sensor: 0 % ... 100 % oxygen (at atmospheric pressure); ≥ 1 000 000 % volume oxygen hours; output: 13 mV ... 16 mV; electrical interface: 3,5 mm mono phone jack; meets ISO 80601-2-55 requirements
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-envitec-oom-sensors