Overview
product24

Protect workers from the threat of volatile organic compounds (VOCs) in the workplace and observe conditions remotely from a central command station with this compact, wireless monitor. The ToxiRAE Pro PID’s next-generation sensor can detect over 300 VOCs and uses a built-in on-board library of 190 correction factors to automatically read gases in equivalent units. Reliable, rugged, and intrinsically safe, the ToxiRAE Pro PID can be easily attached to workers’ uniforms, and also provides a man-down alarm. It all adds up to better visibility and faster incident response in a variety of conditions.

Features and Benefits:

  • Compact, personal wireless monitor
  • PID sensor accurately monitors over 300 VOCs
  • Built-in library of 190 correction factors for automatic reading in equivalent units
  • 5-way local and remote wireless alarm
  • Water-, dust-, and shock-resistant
  • Built-in man down alarm
  • Fully automatic bump testing and calibration with AutoRAE2
  • Readily enables to communicate with Motorola MOTOTRBO

Application:

  • Environmental Cleanups/ Remediation
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Worker Exposure
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Overview

  • Brand
    • RAE
    • RAE Systems by Honeywell
  • Warranty
    • 1 Year on All Other Sensors, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components

Temperature

  • Maximum Temperature
    • 131 degree Fahrenheit
    • 55 degree Celsius

Dimension & Weight

  • Weight
    • 235 gram
    • 8.29 ounce av

Features

  • Sub-Category
    • Single-Gas
    • Single-Gas
  • Alarm Included
    • Yes
  • Alarm Type
    • Audible (95 dB)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)
  • Datalogging Interval
    • 1 Min
    • 1 to 3,600 sec
  • Datalogging
    • Continuous (3 Months)
    • Three-month capacity
  • Display Included
    • Yes
  • Display Readout
    • Real-Time Reading of VOC Concentrations in ppm or mg/m3; Battery Status; Data Logging ON/OFF; Wireless ON/OFF and Reception Quality - STEL, TWA, and Peak Values
  • Display Type
    • Graphical LCD Display with White LED Backlighting
  • Features & Benefits
    • 55 Built-in LEL Correction Factors
    • Continuous Datalogging
    • Device Management with Honeywell SafetySuite
    • Largest Display in Its Class
    • Reliable, Rugged, and Intrinsically Safe
    • Unmistakable 5-Way Local and Remote Wireless Notification of Alarm Conditions
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
  • User Options
    • Wireless remote alarm notification; audible (95 dB @ 30 cm)
  • Wireless Technology
    • MESH
  • Includes
    • AC Adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)
    • CD with Documentation
    • Calibration Adapters
    • Calibration Card, Quality Certificate, and Warranty/Registration Card
    • Charging and PC Communication Cradle
    • Combined Instrument/Sensor Cap Removal Tool
    • PC Communication Cable
    • Quick Start Guide
    • ToxiRAE Pro PID Monitor with Sensor as Specified, Alligator Clip, Protective Rubber Boot, and Rechargeable Battery Installed
    • Warranty/Registration Card

Dimensions & Weight

  • Instrument Size
    • 4.6 inch H x 2.4 inch W x 1.2 inch D (118 x 60 x 30 mm)
  • Weight range
    • 235 g
  • Dimension
    • H: 118 mm W: 60 mm D: 30 mm

Technical Specifications

  • Humidity Range
    • 0 to 95% RH (Non-Condensing)
    • 0%-95%
  • Sensor Range
    • VOC (0-2000ppm)
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Sensor Type
    • Photoionization Sensor
  • Gas Type
    • VOC
  • Communication and Data Download
    • Data Download and Instrument Setup on PC via Charging and PC Communication Cradle
    • Data Download via AutoRAE 2 Automatic Test and Calibration System
    • Wireless Data and Status Transmission via Built-in RF Modem (Optional)
  • Wireless Frequency
    • ISM License-Free Bands
  • Wireless Network
    • Closed-Loop Network with the EchoView Host
    • ProRAE Guardian Real-Time Wireless Safety System
  • Detectable Gases
    • A Wide Variety of Ionizable Chemicals Using 190 Built-in and Over 300 Published Correction Factors
  • Wireless Range
    • ToxiRAE Pro PID to Mesh Router, EchoView Host, or Mesh Reader2 - 330 ft (100m)
    • ToxiRAE Pro PID to RAELink3 Mesh or RAELink3 Z1 Mesh Modems - 33 ft (10m)
  • Battery Life
    • 12 Hours
  • Keypad Type
    • 2 Buttons for Operation and Programming
  • Sampling
    • Internal Fan

Battery & Charging

  • Batteries Required
    • Rechargeable Li-Ion Battery
  • Batteries Included
    • Yes
  • Battery Run Time
    • 12 Hours

Standards & Certifications

  • Standards
    • Class I, Division 1, Groups A, B, C, D, T4
  • Ingress Protection
    • IP65
  • Hazardous Location Approvals
    • ATEX: II 1G, Ex ia IIC Ga T4
    • CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I, Zone 0 A/Exia IIC T4
    • China Ex: Ex ia IIC T4
    • IECEx: Ex ia IIC Ga T4

Applications & Compatibility

  • Application
    • Chemical Plants
    • Environmental
    • First Responders
    • Government Health, Safety, Security, and Environmental Agencies
    • Hazardous Materials Teams
    • Industrial Hygiene and Safety Soil Remediation
    • Oil and Gas
    • Pharmaceutical

Overview

  • Brand
    • RAE
    • RAE Systems by Honeywell
  • Warranty
    • 1 Year on All Other Sensors, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components

Temperature

  • Maximum Temperature
    • 131 degree Fahrenheit
    • 55 degree Celsius

Dimension & Weight

  • Weight
    • 235 gram
    • 8.29 ounce av

Features

  • Sub-Category
    • Single-Gas
    • Single-Gas
  • Alarm Included
    • Yes
  • Alarm Type
    • Audible (95 dB)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)
  • Datalogging Interval
    • 1 Min
    • 1 to 3,600 sec
  • Datalogging
    • Continuous (3 Months)
    • Three-month capacity
  • Display Included
    • Yes
  • Display Readout
    • Real-Time Reading of VOC Concentrations in ppm or mg/m3; Battery Status; Data Logging ON/OFF; Wireless ON/OFF and Reception Quality - STEL, TWA, and Peak Values
  • Display Type
    • Graphical LCD Display with White LED Backlighting
  • Features & Benefits
    • 55 Built-in LEL Correction Factors
    • Continuous Datalogging
    • Device Management with Honeywell SafetySuite
    • Largest Display in Its Class
    • Reliable, Rugged, and Intrinsically Safe
    • Unmistakable 5-Way Local and Remote Wireless Notification of Alarm Conditions
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
  • User Options
    • Wireless remote alarm notification; audible (95 dB @ 30 cm)
  • Wireless Technology
    • MESH
  • Includes
    • AC Adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)
    • CD with Documentation
    • Calibration Adapters
    • Calibration Card, Quality Certificate, and Warranty/Registration Card
    • Charging and PC Communication Cradle
    • Combined Instrument/Sensor Cap Removal Tool
    • PC Communication Cable
    • Quick Start Guide
    • ToxiRAE Pro PID Monitor with Sensor as Specified, Alligator Clip, Protective Rubber Boot, and Rechargeable Battery Installed
    • Warranty/Registration Card

Dimensions & Weight

  • Instrument Size
    • 4.6 inch H x 2.4 inch W x 1.2 inch D (118 x 60 x 30 mm)
  • Weight range
    • 235 g
  • Dimension
    • H: 118 mm W: 60 mm D: 30 mm

Technical Specifications

  • Humidity Range
    • 0 to 95% RH (Non-Condensing)
    • 0%-95%
  • Sensor Range
    • VOC (0-2000ppm)
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Sensor Type
    • Photoionization Sensor
  • Gas Type
    • VOC
  • Communication and Data Download
    • Data Download and Instrument Setup on PC via Charging and PC Communication Cradle
    • Data Download via AutoRAE 2 Automatic Test and Calibration System
    • Wireless Data and Status Transmission via Built-in RF Modem (Optional)
  • Wireless Frequency
    • ISM License-Free Bands
  • Wireless Network
    • Closed-Loop Network with the EchoView Host
    • ProRAE Guardian Real-Time Wireless Safety System
  • Detectable Gases
    • A Wide Variety of Ionizable Chemicals Using 190 Built-in and Over 300 Published Correction Factors
  • Wireless Range
    • ToxiRAE Pro PID to Mesh Router, EchoView Host, or Mesh Reader2 - 330 ft (100m)
    • ToxiRAE Pro PID to RAELink3 Mesh or RAELink3 Z1 Mesh Modems - 33 ft (10m)
  • Battery Life
    • 12 Hours
  • Keypad Type
    • 2 Buttons for Operation and Programming
  • Sampling
    • Internal Fan

Battery & Charging

  • Batteries Required
    • Rechargeable Li-Ion Battery
  • Batteries Included
    • Yes
  • Battery Run Time
    • 12 Hours

Standards & Certifications

  • Standards
    • Class I, Division 1, Groups A, B, C, D, T4
  • Ingress Protection
    • IP65
  • Hazardous Location Approvals
    • ATEX: II 1G, Ex ia IIC Ga T4
    • CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I, Zone 0 A/Exia IIC T4
    • China Ex: Ex ia IIC T4
    • IECEx: Ex ia IIC Ga T4

Applications & Compatibility

  • Application
    • Chemical Plants
    • Environmental
    • First Responders
    • Government Health, Safety, Security, and Environmental Agencies
    • Hazardous Materials Teams
    • Industrial Hygiene and Safety Soil Remediation
    • Oil and Gas
    • Pharmaceutical
  • Brand : RAE|RAE Systems by Honeywell
  • Maximum Temperature : 131 degree Fahrenheit|55 degree Celsius
  • Weight : 235 gram|8.29 ounce av
  • Sub-Category : Single-Gas|Single-Gas
  • Instrument Size : 4.6 inch H x 2.4 inch W x 1.2 inch D (118 x 60 x 30 mm)
  • Weight range : 235 g
  • Humidity Range : 0 to 95% RH (Non-Condensing)|0%-95%
  • Sensor Range : VOC (0-2000ppm)
  • Alarm Included : Yes
  • Alarm Type : Audible (95 dB)|Vibrating|Visual (Flashing Bright Red LEDs)
  • Batteries Required : Rechargeable Li-Ion Battery
  • Batteries Included : Yes
  • Battery Run Time : 12 Hours
  • Calibration : Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Standards : Class I, Division 1, Groups A, B, C, D, T4
  • Datalogging Interval : 1 Min|1 to 3,600 sec
  • Datalogging : Continuous (3 Months)|Three-month capacity
  • Display Included : Yes
  • Display Readout : Real-Time Reading of VOC Concentrations in ppm or mg/m3; Battery Status; Data Logging ON/OFF; Wireless ON/OFF and Reception Quality - STEL, TWA, and Peak Values
  • Display Type : Graphical LCD Display with White LED Backlighting
  • Features & Benefits : 55 Built-in LEL Correction Factors|Continuous Datalogging|Device Management with Honeywell SafetySuite|Largest Display in Its Class|Reliable, Rugged, and Intrinsically Safe|Unmistakable 5-Way Local and Remote Wireless Notification of Alarm Conditions|Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
  • User Options : Wireless remote alarm notification; audible (95 dB @ 30 cm)
  • Sensor Type : Photoionization Sensor
  • Warranty : 1 Year on All Other Sensors, Battery, and Other Consumable Parts|2 Years on Non-Consumable Components
  • Wireless Technology : MESH
  • Ingress Protection : IP65
  • Gas Type : VOC
  • Communication and Data Download : Data Download and Instrument Setup on PC via Charging and PC Communication Cradle|Data Download via AutoRAE 2 Automatic Test and Calibration System|Wireless Data and Status Transmission via Built-in RF Modem (Optional)
  • Hazardous Location Approvals : ATEX: II 1G, Ex ia IIC Ga T4|CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I, Zone 0 A/Exia IIC T4|China Ex: Ex ia IIC T4|IECEx: Ex ia IIC Ga T4
  • Wireless Frequency : ISM License-Free Bands
  • Wireless Network : Closed-Loop Network with the EchoView Host|ProRAE Guardian Real-Time Wireless Safety System
  • Detectable Gases : A Wide Variety of Ionizable Chemicals Using 190 Built-in and Over 300 Published Correction Factors
  • Wireless Range : ToxiRAE Pro PID to Mesh Router, EchoView Host, or Mesh Reader2 - 330 ft (100m)|ToxiRAE Pro PID to RAELink3 Mesh or RAELink3 Z1 Mesh Modems - 33 ft (10m)
  • Battery Life : 12 Hours
  • Keypad Type : 2 Buttons for Operation and Programming
  • Application : Chemical Plants|Environmental|First Responders|Government Health, Safety, Security, and Environmental Agencies|Hazardous Materials Teams|Industrial Hygiene and Safety Soil Remediation|Oil and Gas|Pharmaceutical
  • Dimension : H: 118 mm W: 60 mm D: 30 mm
  • Sampling : Internal Fan
  • Includes : AC Adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)|CD with Documentation|Calibration Adapters|Calibration Card, Quality Certificate, and Warranty/Registration Card|Charging and PC Communication Cradle|Combined Instrument/Sensor Cap Removal Tool|PC Communication Cable|Quick Start Guide|ToxiRAE Pro PID Monitor with Sensor as Specified, Alligator Clip, Protective Rubber Boot, and Rechargeable Battery Installed|Warranty/Registration Card
Data Sheet
Name
Description
File Size
Date
Size
ToxiRAE 3 Data Sheet - EN
application/pdf 104.8 KB
7/15/2021
104.8 KB
Manuals and Guides
Name
Description
File Size
Date
Size
ToxiRAE Pro PID Manual Rev D
application/pdf 3.31 MB
7/15/2021
3.31 MB
ToxiRAE Pro PID QuickStart Guide Rev D
application/pdf 335.53 KB
7/15/2021
335.53 KB
ToxiRAE Pro PID User Manual
application/pdf 2.56 MB
11/28/2023
2.56 MB
Firmware
Name
Description
File Size
Date
Size
ToxiRAE Pro CO2/LEL/EC/PID V1.86
application/zip 413.87 KB
1/10/2023
413.87 KB
Brochure
Name
Description
File Size
Date
Size
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
10/28/2024
441.3 KB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
ToxiRAE Pro PID Technical Note 106E
application/pdf 429.98 KB
7/15/2021
429.98 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
7/15/2021
1.08 MB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 750.26 KB
11/1/2022
750.26 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
7/15/2021
884.91 KB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
7/15/2021
1.01 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
White Paper
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
7/15/2021
949.42 KB
Certificate
Name
Description
File Size
Date
Size
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
ToxiRAE Pro EU Declaration of Conformity
application/pdf 218.92 KB
10/16/2024
218.92 KB
Application Note
Name
Description
File Size
Date
Size
Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 729.36 KB
7/15/2021
729.36 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
7/15/2021
831.7 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
7/15/2021
901.23 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
Measurement Of PGMEA Using Photoionization Detectors
application/pdf 750.69 KB
7/15/2021
750.69 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 212 Using PIDs For Indoor Air Quality (IAQ) Surveys
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Name
Description
File Size
Date
Size
ToxiRAE Pro PID Manual Rev D
application/pdf 3.31 MB
7/15/2021
3.31 MB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 729.36 KB
7/15/2021
729.36 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
7/15/2021
831.7 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
ToxiRAE Pro PID Technical Note 106E
application/pdf 429.98 KB
7/15/2021
429.98 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
ToxiRAE Pro CO2/LEL/EC/PID V1.86
application/zip 413.87 KB
1/10/2023
413.87 KB
ToxiRAE Pro PID QuickStart Guide Rev D
application/pdf 335.53 KB
7/15/2021
335.53 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
7/15/2021
1.08 MB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 750.26 KB
11/1/2022
750.26 KB
ToxiRAE Pro PID User Manual
application/pdf 2.56 MB
11/28/2023
2.56 MB
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
ToxiRAE Pro EU Declaration of Conformity
application/pdf 218.92 KB
10/16/2024
218.92 KB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
7/15/2021
949.42 KB
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
10/28/2024
441.3 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
7/15/2021
901.23 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
7/15/2021
884.91 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
ToxiRAE 3 Data Sheet - EN
application/pdf 104.8 KB
7/15/2021
104.8 KB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
7/15/2021
1.01 MB
Measurement Of PGMEA Using Photoionization Detectors
application/pdf 750.69 KB
7/15/2021
750.69 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
Application Note 212 Using PIDs For Indoor Air Quality (IAQ) Surveys
application/pdf 1.1 MB
7/15/2021
1.1 MB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Name
Date
Size
Showing 1 to 6 of 6 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
G02-B000-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Non-Wireless
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B000-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Non-Wireless
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B004-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Wireless (900 MHz)
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B004-000
ToxiRAE Pro 10.6 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Wireless (900 MHz)
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B010-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) No Datalogging Non-Wireless
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B010-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) No Datalogging Non-Wireless
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B014-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) No Datalogging Wireless (900 MHz)
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B014-000
ToxiRAE Pro 10.6 eV PID (1 - 1,000 ppm range, 1 ppm res.) No Datalogging Wireless (900 MHz)
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B020-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Non-Wireless
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B020-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Non-Wireless
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B024-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Wireless (900 MHz)
https://s7d1.scene7.com/is/image/Honeywell65/product24
G02-B024-000
ToxiRAE Pro 9.8 eV PID (0.1 - 2,000 ppm range, 0.1 ppm res.) Datalogging Wireless (900 MHz)
https://s7d1.scene7.com/is/image/Honeywell65/product24
Feedback