Single Gas
ToxiRAE Pro PID
Compact, wireless VOC single gas monitor
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Protect workers from the threat of volatile organic compounds (VOCs) in the workplace and observe conditions remotely from a central command station with this compact, wireless monitor. The ToxiRAE Pro PID’s next-generation sensor can detect over 300 VOCs and uses a built-in on-board library of 190 correction factors to automatically read gases in equivalent units. Reliable, rugged, and intrinsically safe, the ToxiRAE Pro PID can be easily attached to workers’ uniforms, and also provides a man-down alarm. It all adds up to better visibility and faster incident response in a variety of conditions.
Features and Benefits:
- Compact, personal wireless monitor
- PID sensor accurately monitors over 300 VOCs
- Built-in library of 190 correction factors for automatic reading in equivalent units
- 5-way local and remote wireless alarm
- Water-, dust-, and shock-resistant
- Built-in man down alarm
- Fully automatic bump testing and calibration with AutoRAE2
- Readily enables to communicate with Motorola MOTOTRBO
Application:
- Environmental Cleanups/ Remediation
- Hazmat Response
- Plant Shutdown & Turn-Around
- Worker Exposure
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Overview
- Brand
- RAE
- RAE Systems by Honeywell
- Warranty
- 1 Year on All Other Sensors, Battery, and Other Consumable Parts
- 2 Years on Non-Consumable Components
Temperature
- Maximum Temperature
- 131 degree Fahrenheit
- 55 degree Celsius
Dimension & Weight
- Weight
- 235 gram
- 8.29 ounce av
Features
- Sub-Category
- Single-Gas
- Single-Gas
- Alarm Included
- Yes
- Alarm Type
- Audible (95 dB)
- Vibrating
- Visual (Flashing Bright Red LEDs)
- Datalogging Interval
- 1 Min
- 1 to 3,600 sec
- Datalogging
- Continuous (3 Months)
- Three-month capacity
- Display Included
- Yes
- Display Readout
- Real-Time Reading of VOC Concentrations in ppm or mg/m3; Battery Status; Data Logging ON/OFF; Wireless ON/OFF and Reception Quality - STEL, TWA, and Peak Values
- Display Type
- Graphical LCD Display with White LED Backlighting
- Features & Benefits
- 55 Built-in LEL Correction Factors
- Continuous Datalogging
- Device Management with Honeywell SafetySuite
- Largest Display in Its Class
- Reliable, Rugged, and Intrinsically Safe
- Unmistakable 5-Way Local and Remote Wireless Notification of Alarm Conditions
- Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
- User Options
- Wireless remote alarm notification; audible (95 dB @ 30 cm)
- Wireless Technology
- MESH
- Includes
- AC Adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)
- CD with Documentation
- Calibration Adapters
- Calibration Card, Quality Certificate, and Warranty/Registration Card
- Charging and PC Communication Cradle
- Combined Instrument/Sensor Cap Removal Tool
- PC Communication Cable
- Quick Start Guide
- ToxiRAE Pro PID Monitor with Sensor as Specified, Alligator Clip, Protective Rubber Boot, and Rechargeable Battery Installed
- Warranty/Registration Card
Dimensions & Weight
- Instrument Size
- 4.6 inch H x 2.4 inch W x 1.2 inch D (118 x 60 x 30 mm)
- Weight range
- 235 g
- Dimension
- H: 118 mm W: 60 mm D: 30 mm
Technical Specifications
- Humidity Range
- 0 to 95% RH (Non-Condensing)
- 0%-95%
- Sensor Range
- VOC (0-2000ppm)
- Calibration
- Automatic with AutoRAE 2 Test and Calibration System or Manual
- Sensor Type
- Photoionization Sensor
- Gas Type
- VOC
- Communication and Data Download
- Data Download and Instrument Setup on PC via Charging and PC Communication Cradle
- Data Download via AutoRAE 2 Automatic Test and Calibration System
- Wireless Data and Status Transmission via Built-in RF Modem (Optional)
- Wireless Frequency
- ISM License-Free Bands
- Wireless Network
- Closed-Loop Network with the EchoView Host
- ProRAE Guardian Real-Time Wireless Safety System
- Detectable Gases
- A Wide Variety of Ionizable Chemicals Using 190 Built-in and Over 300 Published Correction Factors
- Wireless Range
- ToxiRAE Pro PID to Mesh Router, EchoView Host, or Mesh Reader2 - 330 ft (100m)
- ToxiRAE Pro PID to RAELink3 Mesh or RAELink3 Z1 Mesh Modems - 33 ft (10m)
- Battery Life
- 12 Hours
- Keypad Type
- 2 Buttons for Operation and Programming
- Sampling
- Internal Fan
Battery & Charging
- Batteries Required
- Rechargeable Li-Ion Battery
- Batteries Included
- Yes
- Battery Run Time
- 12 Hours
Standards & Certifications
- Standards
- Class I, Division 1, Groups A, B, C, D, T4
- Ingress Protection
- IP65
- Hazardous Location Approvals
- ATEX: II 1G, Ex ia IIC Ga T4
- CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I, Zone 0 A/Exia IIC T4
- China Ex: Ex ia IIC T4
- IECEx: Ex ia IIC Ga T4
Applications & Compatibility
- Application
- Chemical Plants
- Environmental
- First Responders
- Government Health, Safety, Security, and Environmental Agencies
- Hazardous Materials Teams
- Industrial Hygiene and Safety Soil Remediation
- Oil and Gas
- Pharmaceutical
Overview
- Brand
- RAE
- RAE Systems by Honeywell
- Warranty
- 1 Year on All Other Sensors, Battery, and Other Consumable Parts
- 2 Years on Non-Consumable Components
Temperature
- Maximum Temperature
- 131 degree Fahrenheit
- 55 degree Celsius
Dimension & Weight
- Weight
- 235 gram
- 8.29 ounce av
Features
- Sub-Category
- Single-Gas
- Single-Gas
- Alarm Included
- Yes
- Alarm Type
- Audible (95 dB)
- Vibrating
- Visual (Flashing Bright Red LEDs)
- Datalogging Interval
- 1 Min
- 1 to 3,600 sec
- Datalogging
- Continuous (3 Months)
- Three-month capacity
- Display Included
- Yes
- Display Readout
- Real-Time Reading of VOC Concentrations in ppm or mg/m3; Battery Status; Data Logging ON/OFF; Wireless ON/OFF and Reception Quality - STEL, TWA, and Peak Values
- Display Type
- Graphical LCD Display with White LED Backlighting
- Features & Benefits
- 55 Built-in LEL Correction Factors
- Continuous Datalogging
- Device Management with Honeywell SafetySuite
- Largest Display in Its Class
- Reliable, Rugged, and Intrinsically Safe
- Unmistakable 5-Way Local and Remote Wireless Notification of Alarm Conditions
- Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
- User Options
- Wireless remote alarm notification; audible (95 dB @ 30 cm)
- Wireless Technology
- MESH
- Includes
- AC Adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)
- CD with Documentation
- Calibration Adapters
- Calibration Card, Quality Certificate, and Warranty/Registration Card
- Charging and PC Communication Cradle
- Combined Instrument/Sensor Cap Removal Tool
- PC Communication Cable
- Quick Start Guide
- ToxiRAE Pro PID Monitor with Sensor as Specified, Alligator Clip, Protective Rubber Boot, and Rechargeable Battery Installed
- Warranty/Registration Card
Dimensions & Weight
- Instrument Size
- 4.6 inch H x 2.4 inch W x 1.2 inch D (118 x 60 x 30 mm)
- Weight range
- 235 g
- Dimension
- H: 118 mm W: 60 mm D: 30 mm
Technical Specifications
- Humidity Range
- 0 to 95% RH (Non-Condensing)
- 0%-95%
- Sensor Range
- VOC (0-2000ppm)
- Calibration
- Automatic with AutoRAE 2 Test and Calibration System or Manual
- Sensor Type
- Photoionization Sensor
- Gas Type
- VOC
- Communication and Data Download
- Data Download and Instrument Setup on PC via Charging and PC Communication Cradle
- Data Download via AutoRAE 2 Automatic Test and Calibration System
- Wireless Data and Status Transmission via Built-in RF Modem (Optional)
- Wireless Frequency
- ISM License-Free Bands
- Wireless Network
- Closed-Loop Network with the EchoView Host
- ProRAE Guardian Real-Time Wireless Safety System
- Detectable Gases
- A Wide Variety of Ionizable Chemicals Using 190 Built-in and Over 300 Published Correction Factors
- Wireless Range
- ToxiRAE Pro PID to Mesh Router, EchoView Host, or Mesh Reader2 - 330 ft (100m)
- ToxiRAE Pro PID to RAELink3 Mesh or RAELink3 Z1 Mesh Modems - 33 ft (10m)
- Battery Life
- 12 Hours
- Keypad Type
- 2 Buttons for Operation and Programming
- Sampling
- Internal Fan
Battery & Charging
- Batteries Required
- Rechargeable Li-Ion Battery
- Batteries Included
- Yes
- Battery Run Time
- 12 Hours
Standards & Certifications
- Standards
- Class I, Division 1, Groups A, B, C, D, T4
- Ingress Protection
- IP65
- Hazardous Location Approvals
- ATEX: II 1G, Ex ia IIC Ga T4
- CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I, Zone 0 A/Exia IIC T4
- China Ex: Ex ia IIC T4
- IECEx: Ex ia IIC Ga T4
Applications & Compatibility
- Application
- Chemical Plants
- Environmental
- First Responders
- Government Health, Safety, Security, and Environmental Agencies
- Hazardous Materials Teams
- Industrial Hygiene and Safety Soil Remediation
- Oil and Gas
- Pharmaceutical
- Brand : RAE|RAE Systems by Honeywell
- Maximum Temperature : 131 degree Fahrenheit|55 degree Celsius
- Weight : 235 gram|8.29 ounce av
- Sub-Category : Single-Gas|Single-Gas
- Instrument Size : 4.6 inch H x 2.4 inch W x 1.2 inch D (118 x 60 x 30 mm)
- Weight range : 235 g
- Humidity Range : 0 to 95% RH (Non-Condensing)|0%-95%
- Sensor Range : VOC (0-2000ppm)
- Alarm Included : Yes
- Alarm Type : Audible (95 dB)|Vibrating|Visual (Flashing Bright Red LEDs)
- Batteries Required : Rechargeable Li-Ion Battery
- Batteries Included : Yes
- Battery Run Time : 12 Hours
- Calibration : Automatic with AutoRAE 2 Test and Calibration System or Manual
- Standards : Class I, Division 1, Groups A, B, C, D, T4
- Datalogging Interval : 1 Min|1 to 3,600 sec
- Datalogging : Continuous (3 Months)|Three-month capacity
- Display Included : Yes
- Display Readout : Real-Time Reading of VOC Concentrations in ppm or mg/m3; Battery Status; Data Logging ON/OFF; Wireless ON/OFF and Reception Quality - STEL, TWA, and Peak Values
- Display Type : Graphical LCD Display with White LED Backlighting
- Features & Benefits : 55 Built-in LEL Correction Factors|Continuous Datalogging|Device Management with Honeywell SafetySuite|Largest Display in Its Class|Reliable, Rugged, and Intrinsically Safe|Unmistakable 5-Way Local and Remote Wireless Notification of Alarm Conditions|Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
- User Options : Wireless remote alarm notification; audible (95 dB @ 30 cm)
- Sensor Type : Photoionization Sensor
- Warranty : 1 Year on All Other Sensors, Battery, and Other Consumable Parts|2 Years on Non-Consumable Components
- Wireless Technology : MESH
- Ingress Protection : IP65
- Gas Type : VOC
- Communication and Data Download : Data Download and Instrument Setup on PC via Charging and PC Communication Cradle|Data Download via AutoRAE 2 Automatic Test and Calibration System|Wireless Data and Status Transmission via Built-in RF Modem (Optional)
- Hazardous Location Approvals : ATEX: II 1G, Ex ia IIC Ga T4|CSA: Class I, Division 1, Groups A, B, C and D. T-code T4 Class I, Zone 0 A/Exia IIC T4|China Ex: Ex ia IIC T4|IECEx: Ex ia IIC Ga T4
- Wireless Frequency : ISM License-Free Bands
- Wireless Network : Closed-Loop Network with the EchoView Host|ProRAE Guardian Real-Time Wireless Safety System
- Detectable Gases : A Wide Variety of Ionizable Chemicals Using 190 Built-in and Over 300 Published Correction Factors
- Wireless Range : ToxiRAE Pro PID to Mesh Router, EchoView Host, or Mesh Reader2 - 330 ft (100m)|ToxiRAE Pro PID to RAELink3 Mesh or RAELink3 Z1 Mesh Modems - 33 ft (10m)
- Battery Life : 12 Hours
- Keypad Type : 2 Buttons for Operation and Programming
- Application : Chemical Plants|Environmental|First Responders|Government Health, Safety, Security, and Environmental Agencies|Hazardous Materials Teams|Industrial Hygiene and Safety Soil Remediation|Oil and Gas|Pharmaceutical
- Dimension : H: 118 mm W: 60 mm D: 30 mm
- Sampling : Internal Fan
- Includes : AC Adapter (100 to 240 V, 50/60 Hz AC to 12 V DC)|CD with Documentation|Calibration Adapters|Calibration Card, Quality Certificate, and Warranty/Registration Card|Charging and PC Communication Cradle|Combined Instrument/Sensor Cap Removal Tool|PC Communication Cable|Quick Start Guide|ToxiRAE Pro PID Monitor with Sensor as Specified, Alligator Clip, Protective Rubber Boot, and Rechargeable Battery Installed|Warranty/Registration Card
Data Sheet
Manuals and Guides
Firmware
Brochure
Technical Note
White Paper
Certificate
Application Note
Please sign in to view part numbers available for purchase based on your account Sign In
Please sign in to view part numbers available for purchase based on your account Sign In