Products
Products
News and Events
Part Numbers
General Content
/content/sps/us/en/search-results.html

Fixed Gas Detectors

Sensepoint Flammable

Sensepoint Flammable (0-100%LEL +80°C, 0-10%LEL +65°C)

Overview
Sensepoint family product image displayed from up side view
The Sensepoint range of flammable, toxic and oxygen gas detectors offerusers a high quality, low cost solution to their industrial gas monitoringneeds. Installation in potentially explosive atmospheres is made by theuse of a suitable Ex d or EX e approved junction box. The industry standardoutputs from Sensepoint are connected to either a choice of HoneywellAnalytics’ controllers or 3rd party DCS/PLC systems. both flammable andtoxic versions are certified to ATEX and IECEx. The flammable detector is available in either %LEL or PPM detection rangeversions and provides an industry standard mV bridge output. Typical lifeexpectancy is greater than 5 years, after which the detector is simplyreplaced with a new one. The toxic detectors are supplied pre calibratedfor easy installation and provide an industry standard 2 wire 4-20mA loopoutput. User connections are Ex d, while front end Intrinsic Safety (IS)design allows for easy exchange of the replaceable sensor while poweredIS design also removes the need for a sinter enabling very fast speed ofresponse and detection of ‘sticky’ gases such as Chlorine and Ammonia.The Sensepoint high temperature sensor has been specifically designedfor the detection of combustible gases in high temperature hazardous arealocations. Typical applications include turbine enclosures and drying ovensused in solvent based printing and coating machines. These applicationsrequire a sensor that provides reliable and stable detection allowing lowlevel alarm settings across a wide temperature range. Utilizing a speciallymatched pair of Sieger poison resistant combustible gas detectionelements, the Sensepoint High Temperature Sensor has a very stablebaseline allowing alarm trip points to be set as low as 5% LEL across atemperature range of -55°C to +150°C (-67°F to +302°F). The gas measuringrange can be configured from 0-20% LEL up to 0-100% LEL depending on thetype of controller used.
Specifications

Overview

  • Brand
    • Honeywell

Dimensions & Weight

  • Weight range
    • 190 g

Technical Specifications

  • Humidity Range
    • Continuous: 20 to 90% RH (Non-Condensing)
    • Intermittent: 10 to 99% RH (Non-Condensing)
  • Analog Output Connection
    • 3-Wire
  • Maximum Pressure
    • 110 kPa
  • Warm Up Time
    • < 10 min
  • Stability (zero)
    • With Humidity: < ±1% fsd
    • With Temperature: < ±1% fsd
    • With Time: < ±3% fsd/yr
  • Stability (span)
    • With Humidity: < ±2% fsd
    • With Temperature: < ±3% fsd
    • With Time: < ±3% fsd/yr
  • Signal Output
    • mV Bridge
  • Conduit Entries
    • 3/4 in NPT
    • M20
    • M25
    • M26

Operating Characteristics

  • Minimum Temperature
    • -40˚C
  • Storage Temperature
    • 0 to 25˚C

Features

  • Alarm Included
    • No
  • Features & Benefits
    • 2 to 5 Years Operational Life
    • Collecting Cone
    • Complies with the Latest Standards
    • Duct Mounting Kit
    • Factory Set Operation
    • Fast and Reliable
    • Flammable, Toxic and Oxygen Versions Available
    • Flow Adaptor
    • Hazardous Area Approval and Performance
    • High Performance, Low Cost
    • IP65/67
    • Minimal Training Required
    • Poison Resistant Catalytic Bead
    • Simple to Replace
    • Suitable for New and Retro Fit Applications
    • SureCell Electrochemical Sensors
    • Weatherproof Cap
  • Filter Included
    • Yes
  • Storage Life
    • 5 Years

Material Specifications

  • Material
    • Polyphenylene Sulphide (PPS)

Standards & Certifications

  • Ingress Protection
    • IP65/67

Electrical Specifications

  • Power Requirement
    • 0.7 W @200 mA

Overview

  • Brand
    • Honeywell

Dimensions & Weight

  • Weight range
    • 190 g

Technical Specifications

  • Humidity Range
    • Continuous: 20 to 90% RH (Non-Condensing)
    • Intermittent: 10 to 99% RH (Non-Condensing)
  • Analog Output Connection
    • 3-Wire
  • Maximum Pressure
    • 110 kPa
  • Warm Up Time
    • < 10 min
  • Stability (zero)
    • With Humidity: < ±1% fsd
    • With Temperature: < ±1% fsd
    • With Time: < ±3% fsd/yr
  • Stability (span)
    • With Humidity: < ±2% fsd
    • With Temperature: < ±3% fsd
    • With Time: < ±3% fsd/yr
  • Signal Output
    • mV Bridge
  • Conduit Entries
    • 3/4 in NPT
    • M20
    • M25
    • M26

Operating Characteristics

  • Minimum Temperature
    • -40˚C
  • Storage Temperature
    • 0 to 25˚C

Features

  • Alarm Included
    • No
  • Features & Benefits
    • 2 to 5 Years Operational Life
    • Collecting Cone
    • Complies with the Latest Standards
    • Duct Mounting Kit
    • Factory Set Operation
    • Fast and Reliable
    • Flammable, Toxic and Oxygen Versions Available
    • Flow Adaptor
    • Hazardous Area Approval and Performance
    • High Performance, Low Cost
    • IP65/67
    • Minimal Training Required
    • Poison Resistant Catalytic Bead
    • Simple to Replace
    • Suitable for New and Retro Fit Applications
    • SureCell Electrochemical Sensors
    • Weatherproof Cap
  • Filter Included
    • Yes
  • Storage Life
    • 5 Years

Material Specifications

  • Material
    • Polyphenylene Sulphide (PPS)

Standards & Certifications

  • Ingress Protection
    • IP65/67

Electrical Specifications

  • Power Requirement
    • 0.7 W @200 mA
  • Brand : Honeywell
  • Weight range : 190 g
  • Humidity Range : Continuous: 20 to 90% RH (Non-Condensing)|Intermittent: 10 to 99% RH (Non-Condensing)
  • Minimum Temperature : -40˚C
  • Alarm Included : No
  • Analog Output Connection : 3-Wire
  • Features & Benefits : 2 to 5 Years Operational Life|Collecting Cone|Complies with the Latest Standards|Duct Mounting Kit|Factory Set Operation|Fast and Reliable|Flammable, Toxic and Oxygen Versions Available|Flow Adaptor|Hazardous Area Approval and Performance|High Performance, Low Cost|IP65/67|Minimal Training Required|Poison Resistant Catalytic Bead|Simple to Replace|Suitable for New and Retro Fit Applications|SureCell Electrochemical Sensors|Weatherproof Cap
  • Filter Included : Yes
  • Material : Polyphenylene Sulphide (PPS)
  • Maximum Pressure : 110 kPa
  • Ingress Protection : IP65/67
  • Warm Up Time : < 10 min
  • Storage Temperature : 0 to 25˚C
  • Storage Life : 5 Years
  • Stability (zero) : With Humidity: < ±1% fsd|With Temperature: < ±1% fsd|With Time: < ±3% fsd/yr
  • Stability (span) : With Humidity: < ±2% fsd|With Temperature: < ±3% fsd|With Time: < ±3% fsd/yr
  • Signal Output : mV Bridge
  • Power Requirement : 0.7 W @200 mA
  • Conduit Entries : 3/4 in NPT|M20|M25|M26
Showing 1 to 7 of 7 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
2106B1200
SENSEPOINT 0-100LEL COMB M20 (ATEX)
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1200
SENSEPOINT 0-100LEL COMB M20 (ATEX)
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1201
SENSEPOINT 0-100%LEL COMBUSTIBLE M25
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1201
SENSEPOINT 0-100%LEL COMBUSTIBLE M25
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1202
Sensepoint 0-100% LEL Flam. Sensor M26
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1202
Sensepoint 0-100% LEL Flam. Sensor M26
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1204
SENSEPOINT 0-100LEL COMB 34NPT ATEX
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1204
SENSEPOINT 0-100LEL COMB 34NPT ATEX
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1205
SENSEPOINT PPM (0-10% LEL) COMB SEN
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1205
SENSEPOINT PPM (0-10% LEL) COMB SEN
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1209
Sensepoint ppm Flam. Sensor 34NPT*
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B1209
Sensepoint ppm Flam. Sensor 34NPT*
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B2310
SENSEPOINT HGH TMP CMB SNSR M20 ATEX
https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-2106b2310-sensepoint-high-temperature-flammable-sensor-primaryimage
2106B2310
SENSEPOINT HGH TMP CMB SNSR M20 ATEX
https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-2106b2310-sensepoint-high-temperature-flammable-sensor-primaryimage
2106B2311
SENSEPOINT HGH TMP CMB SNSR M25 ATEX
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B2311
SENSEPOINT HGH TMP CMB SNSR M25 ATEX
https://honeywell.scene7.com/is/image/Honeywell65/hon-ia-pmc-sensepoint-image-hero
2106B2312
SENSEPOINT HGH TMP CMB SNSR 34 ATEX
https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-2106b2310-sensepoint-high-temperature-flammable-sensor-primaryimage
2106B2312
SENSEPOINT HGH TMP CMB SNSR 34 ATEX
https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-2106b2310-sensepoint-high-temperature-flammable-sensor-primaryimage
Feedback