    Detectores de fotoionização (PID)

    MiniRAE 3000 +

    The most advanced wireless handheld VOC monitor with parts per million measurement

    Overview
    Whether for industrial hygiene, leak detection, or HazMat response, the MiniRAE 3000 + delivers one of the most advanced VOC monitoring capabilities on the market. With a photoionization detector (PID) that has an extended detection range from 0-15,000 ppm, a rapid three-second response time, built-in correction factors for more than 200 compounds, patented auto-cleaning sensor technology and Reflex PID Technology™, the MiniRAE 3000 + can measure one of the highest levels of ionizable chemicals available on the market.The powerful sample pump draws through up to 100 feet of tubing horizontally or vertically. A built-in flashlight to help navigate in darker environments and an IP 65/67 dust-tight and water-proof housing all add up to a device that performs reliably even in harsh conditions.MiniRAE 3000 + is solution oriented through multiple connected options. A dedicated mobile APP has been developed for Remediation engineers and Industrial Hygienists. Instrument is also available with real time connectivity which can relay readings and alarm status up to 2 miles to a RAELink 3 wireless transmitter.Features and Benefits:
    • Most advanced handheld VOC monitor on the market
    • PID measures from 0-15,000 ppm
    • 3-second response
    • Humidity compensation
    • Patented PID lamp auto-cleaning technology
    • Patented Reflex PID Technology™
    • Optional Mesh Radio for ConneXT compatibility
    • Optional built-in Bluetooth transmitter that transmits real-time data up to 2 miles with RAELink3 wireless router
    • Optional BLE Module
    • Sample pump draws from up to 100 feet
    • Correction factors for more than 200 compounds
    • Built-in flashlight
    • IP 65/67 water-proof and dust-tight
    • Logs up to 6 months of data at 1-minute intervals
    • Multi-language capability – up to 10 languages
    • 9.8eV for benzene and TVOC and 10.6 and 11.7 UV lamps for TVOC
    Application:
    • Emergency Response
    • Environmental Cleanups/ Remediation
    • Hazmat Response
    • Leak Detection
    • Urban Search & Rescue
    • Venue Protection
    • Worker Exposure
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    MiniRAE 3000 + Data Sheet - RU
    application/pdf 604.02 KB
    9/1/2021
    604.02 KB
    MiniRAE 3000 + Data Sheet - FR
    application/pdf 574.31 KB
    9/1/2021
    574.31 KB
    MiniRAE 3000 + Data Sheet - EN
    application/pdf 570.25 KB
    9/1/2021
    570.25 KB
    MiniRAE 3000 + Data Sheet - PT
    application/pdf 574.41 KB
    9/1/2021
    574.41 KB
    MiniRAE 3000 + Data Sheet - NL
    application/pdf 572.3 KB
    9/1/2021
    572.3 KB
    MiniRAE 3000 + Data Sheet - ES
    application/pdf 572.94 KB
    9/1/2021
    572.94 KB
    MiniRAE 3000+ Data Sheet - DE
    application/pdf 575.45 KB
    9/1/2021
    575.45 KB
    MiniRAE 3000 + Data Sheet - IT
    application/pdf 577.93 KB
    9/1/2021
    577.93 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    3000+ Series PID Quick Start Guide - EN
    application/pdf 737.56 KB
    4/23/2024
    737.56 KB
    3G PID User Guide - FR
    application/pdf 7.57 MB
    9/1/2021
    7.57 MB
    3000+ Series PID Quick Start Guide - PT
    application/pdf 736.66 KB
    9/1/2021
    736.66 KB
    3G PID User Guide - ES
    application/pdf 7.53 MB
    9/1/2021
    7.53 MB
    3000+ Series PID Quick Start Guide - FR
    application/pdf 736.61 KB
    9/1/2021
    736.61 KB
    3000+ Series PID Quick Start Guide - RU
    application/pdf 784.44 KB
    9/1/2021
    784.44 KB
    3000+ Series PID Quick Start Guide - IT
    application/pdf 734.57 KB
    9/1/2021
    734.57 KB
    3000+ Series PID Quick Start Guide - NL
    application/pdf 736.75 KB
    9/1/2021
    736.75 KB
    3G PID User Guide - EN
    application/pdf 7.52 MB
    9/1/2021
    7.52 MB
    3000+ Series PID Quick Start Guide - DE
    application/pdf 739.46 KB
    9/1/2021
    739.46 KB
    3G PID User Guide - RU
    application/pdf 7.71 MB
    9/1/2021
    7.71 MB
    3000+ Series PID Quick Start Guide - ES
    application/pdf 735.47 KB
    9/1/2021
    735.47 KB
    3G PID User Guide - PT
    application/pdf 7.58 MB
    9/1/2021
    7.58 MB
    3G PID User Guide - NL
    application/pdf 7.5 MB
    9/1/2021
    7.5 MB
    3G PID User Guide - IT
    application/pdf 7.57 MB
    9/1/2021
    7.57 MB
    Software
    Name
    Description
    File Size
    Date
    Size
    MiniRAE3000+ PGM-7320 V2.22A.35
    application/zip 963.57 KB
    10/13/2021
    963.57 KB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    9/1/2021
    1.09 MB
    PID Lamp Characteristics Technical Note 124
    application/pdf 768.24 KB
    9/1/2021
    768.24 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    9/1/2021
    911.54 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    9/1/2021
    790.79 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    9/1/2021
    926.7 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    9/1/2021
    950.72 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    9/1/2021
    788.83 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    9/1/2021
    814.89 KB
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    application/pdf 813.81 KB
    9/1/2021
    813.81 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    9/1/2021
    930.69 KB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    9/1/2021
    1.26 MB
    Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
    application/pdf 624.75 KB
    9/1/2021
    624.75 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    9/1/2021
    655.59 KB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    9/1/2021
    1.07 MB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    9/1/2021
    1.26 MB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    9/1/2021
    1.1 MB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    9/1/2021
    964.88 KB
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    9/1/2021
    836.36 KB
    Others
    Name
    Description
    File Size
    Date
    Size
    3G PID User Guide - EN
    application/pdf 4.11 MB
    9/1/2021
    4.11 MB
    Name
    Description
    File Size
    Date
    Size
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    9/1/2021
    1.09 MB
    3000+ Series PID Quick Start Guide - EN
    application/pdf 737.56 KB
    4/23/2024
    737.56 KB
    PID Lamp Characteristics Technical Note 124
    application/pdf 768.24 KB
    9/1/2021
    768.24 KB
    3G PID User Guide - FR
    application/pdf 7.57 MB
    9/1/2021
    7.57 MB
    3000+ Series PID Quick Start Guide - PT
    application/pdf 736.66 KB
    9/1/2021
    736.66 KB
    3G PID User Guide - ES
    application/pdf 7.53 MB
    9/1/2021
    7.53 MB
    MiniRAE 3000 + Data Sheet - RU
    application/pdf 604.02 KB
    9/1/2021
    604.02 KB
    3G PID User Guide - EN
    application/pdf 4.11 MB
    9/1/2021
    4.11 MB
    MiniRAE 3000 + Data Sheet - FR
    application/pdf 574.31 KB
    9/1/2021
    574.31 KB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    9/1/2021
    655.59 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    9/1/2021
    911.54 KB
    3000+ Series PID Quick Start Guide - FR
    application/pdf 736.61 KB
    9/1/2021
    736.61 KB
    3000+ Series PID Quick Start Guide - RU
    application/pdf 784.44 KB
    9/1/2021
    784.44 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    9/1/2021
    790.79 KB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    9/1/2021
    1.07 MB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    9/1/2021
    1.26 MB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    MiniRAE 3000 + Data Sheet - EN
    application/pdf 570.25 KB
    9/1/2021
    570.25 KB
    3000+ Series PID Quick Start Guide - IT
    application/pdf 734.57 KB
    9/1/2021
    734.57 KB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    9/1/2021
    926.7 KB
    3000+ Series PID Quick Start Guide - NL
    application/pdf 736.75 KB
    9/1/2021
    736.75 KB
    3G PID User Guide - EN
    application/pdf 7.52 MB
    9/1/2021
    7.52 MB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    9/1/2021
    950.72 KB
    MiniRAE3000+ PGM-7320 V2.22A.35
    application/zip 963.57 KB
    10/13/2021
    963.57 KB
    MiniRAE 3000 + Data Sheet - PT
    application/pdf 574.41 KB
    9/1/2021
    574.41 KB
    3000+ Series PID Quick Start Guide - DE
    application/pdf 739.46 KB
    9/1/2021
    739.46 KB
    MiniRAE 3000 + Data Sheet - NL
    application/pdf 572.3 KB
    9/1/2021
    572.3 KB
    3G PID User Guide - RU
    application/pdf 7.71 MB
    9/1/2021
    7.71 MB
    MiniRAE 3000 + Data Sheet - ES
    application/pdf 572.94 KB
    9/1/2021
    572.94 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    3000+ Series PID Quick Start Guide - ES
    application/pdf 735.47 KB
    9/1/2021
    735.47 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    9/1/2021
    1.1 MB
    3G PID User Guide - PT
    application/pdf 7.58 MB
    9/1/2021
    7.58 MB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    9/1/2021
    788.83 KB
    MiniRAE 3000+ Data Sheet - DE
    application/pdf 575.45 KB
    9/1/2021
    575.45 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    9/1/2021
    814.89 KB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    9/1/2021
    964.88 KB
    MiniRAE 3000 + Data Sheet - IT
    application/pdf 577.93 KB
    9/1/2021
    577.93 KB
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    application/pdf 813.81 KB
    9/1/2021
    813.81 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    9/1/2021
    930.69 KB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    9/1/2021
    1.26 MB
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    9/1/2021
    836.36 KB
    Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
    application/pdf 624.75 KB
    9/1/2021
    624.75 KB
    3G PID User Guide - NL
    application/pdf 7.5 MB
    9/1/2021
    7.5 MB
    3G PID User Guide - IT
    application/pdf 7.57 MB
    9/1/2021
    7.57 MB
    Name
    Description
    File Size
    Date
    Size
    MiniRAE 3000 + Data Sheet - RU
    604.02 KB
    9/1/2021
    MiniRAE 3000 + Data Sheet - FR
    574.31 KB
    9/1/2021
    MiniRAE 3000 + Data Sheet - EN
    570.25 KB
    9/1/2021
    MiniRAE 3000 + Data Sheet - PT
    574.41 KB
    9/1/2021
    MiniRAE 3000 + Data Sheet - NL
    572.3 KB
    9/1/2021
    MiniRAE 3000 + Data Sheet - ES
    572.94 KB
    9/1/2021
    MiniRAE 3000+ Data Sheet - DE
    575.45 KB
    9/1/2021
    MiniRAE 3000 + Data Sheet - IT
    577.93 KB
    9/1/2021
    3000+ Series PID Quick Start Guide - EN
    737.56 KB
    4/23/2024
    3G PID User Guide - FR
    7.57 MB
    9/1/2021
    3000+ Series PID Quick Start Guide - PT
    736.66 KB
    9/1/2021
    3G PID User Guide - ES
    7.53 MB
    9/1/2021
    3000+ Series PID Quick Start Guide - FR
    736.61 KB
    9/1/2021
    3000+ Series PID Quick Start Guide - RU
    784.44 KB
    9/1/2021
    3000+ Series PID Quick Start Guide - IT
    734.57 KB
    9/1/2021
    3000+ Series PID Quick Start Guide - NL
    736.75 KB
    9/1/2021
    3G PID User Guide - EN
    7.52 MB
    9/1/2021
    3000+ Series PID Quick Start Guide - DE
    739.46 KB
    9/1/2021
    3G PID User Guide - RU
    7.71 MB
    9/1/2021
    3000+ Series PID Quick Start Guide - ES
    735.47 KB
    9/1/2021
    3G PID User Guide - PT
    7.58 MB
    9/1/2021
    3G PID User Guide - NL
    7.5 MB
    9/1/2021
    3G PID User Guide - IT
    7.57 MB
    9/1/2021
    MiniRAE3000+ PGM-7320 V2.22A.35
    963.57 KB
    10/13/2021
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    1.09 MB
    9/1/2021
    PID Lamp Characteristics Technical Note 124
    768.24 KB
    9/1/2021
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    911.54 KB
    9/1/2021
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    790.79 KB
    9/1/2021
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Lithium-Ion Batteries Technical Note 166
    926.7 KB
    9/1/2021
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    950.72 KB
    9/1/2021
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    11/1/2022
    Technical Note 130 Setting Alarm Limits For Mixtures
    788.83 KB
    9/1/2021
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    814.89 KB
    9/1/2021
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    813.81 KB
    9/1/2021
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    930.69 KB
    9/1/2021
    Technical Note 170 USB To Serial Port Adapter
    1.26 MB
    9/1/2021
    Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
    624.75 KB
    9/1/2021
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    655.59 KB
    9/1/2021
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    1.07 MB
    9/1/2021
    Application Note 203: PIDs As HazMat Response Tools
    1.26 MB
    9/1/2021
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    9/1/2021
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    964.88 KB
    9/1/2021
    Application Note 214: Environmental Applications For PIDs
    836.36 KB
    9/1/2021
    3G PID User Guide - EN
    4.11 MB
    9/1/2021
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    059-9120-100
    https://s7d1.scene7.com/is/image/Honeywell65/MiniRAE3000-1
    059-9120-100
    https://s7d1.scene7.com/is/image/Honeywell65/MiniRAE3000-1