/content/sps/us/en/search-results.html

    transportable area monitoring

    AreaRAE Plus/Pro Multi-Gas Detector

    Transportable area monitor for multiple threat detection

    Overview
    The AreaRAE Plus provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to configure device. Plus, you’ll have vital details about threats happening in real-time—arming you with the information you need to act quickly.
    Features and Benefits:
    • Monitors up to seven threats, including VOCs, combustibles, Toxics and Oxygen
    • Optional meteorological sensor for tracking toxic plumes
    • 7R+ photoionization detector (PID) for monitoring VOCs at parts per million
    • Secondary radio module (Mesh) act as an communication Hub for other wireless devices
    • Ruggedized, portable, and weather-resistant design for harsh environments
    • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations
    Application:
    • Confined Space Entry
    • Environmental Cleanups/ Remediation
    • Fence Line Monitoring
    • Leak Detection
    • Plant Shutdown & Turn-Around
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Overview

    • Brand
      • RAE
    • Warranty
      • Four years for O2 Liquid Oxygen sensors

    Features

    • Sub-Category
      • Transportable
    • Alarm Type
      • Audible, Visual, Vibrating
    • Datalogging
      • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
    • Features & Benefits
      • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
    • User Options
      • 3 operation and programming keys
    • Wireless Technology
      • BLE, MESH, WiFi, LORA

    Dimensions & Weight

    • Instrument Size
      • 12.36” x 12.04” x 6.53”

    Technical Specifications

    • Sensor Range
      • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
    • Humidity Range
      • 0%-95%
    • Gas Type
      • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3

    Battery & Charging

    • Battery Run Time
      • 20

    Standards & Certifications

    • Standards
      • US and Canada: Class 1, Division 2, Groups A, B, C, D
    • Ingress Protection
      • IP65

    Others

    • Sampling Pump Range
      • 100ft (30m)
    • Weight
      • 14.33 US Pound
      • 6.5 kilogram
    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Maximum Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius
    • Industry
      • Energy
      • Government & Public Sector

    Overview

    • Brand
      • RAE
    • Warranty
      • Four years for O2 Liquid Oxygen sensors

    Features

    • Sub-Category
      • Transportable
    • Alarm Type
      • Audible, Visual, Vibrating
    • Datalogging
      • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
    • Features & Benefits
      • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
    • User Options
      • 3 operation and programming keys
    • Wireless Technology
      • BLE, MESH, WiFi, LORA

    Dimensions & Weight

    • Instrument Size
      • 12.36” x 12.04” x 6.53”

    Technical Specifications

    • Sensor Range
      • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
    • Humidity Range
      • 0%-95%
    • Gas Type
      • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3

    Battery & Charging

    • Battery Run Time
      • 20

    Standards & Certifications

    • Standards
      • US and Canada: Class 1, Division 2, Groups A, B, C, D
    • Ingress Protection
      • IP65

    Others

    • Sampling Pump Range
      • 100ft (30m)
    • Weight
      • 14.33 US Pound
      • 6.5 kilogram
    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Maximum Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius
    • Industry
      • Energy
      • Government & Public Sector
    • Brand : RAE
    • Sampling Pump Range : 100ft (30m)
    • Weight : 14.33 US Pound|6.5 kilogram
    • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
    • Maximum Temperature : 140 degree Fahrenheit|60 degree Celsius
    • Sub-Category : Transportable
    • Instrument Size : 12.36” x 12.04” x 6.53”
    • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
    • Humidity Range : 0%-95%
    • Alarm Type : Audible, Visual, Vibrating
    • Battery Run Time : 20
    • Standards : US and Canada: Class 1, Division 2, Groups A, B, C, D
    • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
    • Features & Benefits : Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
    • User Options : 3 operation and programming keys
    • Warranty : Four years for O2 Liquid Oxygen sensors
    • Wireless Technology : BLE, MESH, WiFi, LORA
    • Ingress Protection : IP65
    • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
    • Industry : Energy|Government & Public Sector
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    Honeywell AreaRAE Plus Datasheet - EN
    application/pdf 425.16 KB
    11/26/2025
    425.16 KB
    Honeywell AreaRAE Plus Datasheet - EN
    application/pdf 425.16 KB
    11/26/2025
    425.16 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Plus/AreaRAE Pro User Manual - EN
    application/pdf 18.88 MB
    5/7/2025
    18.88 MB
    AreaRAE Plus/AreaRAE Pro QSG - EN
    application/pdf 1.81 MB
    5/7/2025
    1.81 MB
    Firmware
    Name
    Description
    File Size
    Date
    Size
    Area RAE 1.12 Firmware and Release Notes
    application/zip 2.01 MB
    8/18/2023
    2.01 MB
    application/zip 1.57 MB
    5/20/2025
    1.57 MB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Plus Brochure
    application/pdf 3.23 MB
    7/15/2021
    3.23 MB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
    application/pdf 146.2 KB
    8/10/2022
    146.2 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    8/3/2022
    1.45 MB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    AreaRAE PlusPro Technical Note 106A
    application/pdf 428.08 KB
    7/15/2021
    428.08 KB
    Technical Note 161 Intrinsic Safety And Hazardous Locations
    application/pdf 884.37 KB
    7/15/2021
    884.37 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Technical Note 163 Addressing PID Instruments Moisture Sensitivity
    application/pdf 944.51 KB
    7/15/2021
    944.51 KB
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    application/pdf 787.55 KB
    7/15/2021
    787.55 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    application/pdf 884.91 KB
    7/15/2021
    884.91 KB
    Technical Note 182 Basics of Wireless Security
    application/pdf 1.01 MB
    7/15/2021
    1.01 MB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    application/pdf 1.08 MB
    7/15/2021
    1.08 MB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    Technical Note 167 Proper Use Of Dilution Fittings On Pumped Monitors
    application/pdf 1.02 MB
    7/15/2021
    1.02 MB
    White Paper
    Name
    Description
    File Size
    Date
    Size
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    application/pdf 949.42 KB
    7/15/2021
    949.42 KB
    Certificate
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Plus and Pro - Certificate of compliance
    application/pdf 45.13 KB
    9/27/2021
    45.13 KB
    AreaRAE Plus and Pro - EU Declaration of Conformity
    application/pdf 154.78 KB
    1/11/2022
    154.78 KB
    RM2400A EU Component of Conformity to Certificates
    application/pdf 110.56 KB
    1/3/2022
    110.56 KB
    AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
    application/pdf 194.1 KB
    1/11/2022
    194.1 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    application/pdf 831.7 KB
    7/15/2021
    831.7 KB
    Application Note 228 - Facility and Venue Protection
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Application Note 215: Gas Detection In The Marine Industries
    application/pdf 889.61 KB
    7/15/2021
    889.61 KB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    application/pdf 826.34 KB
    7/15/2021
    826.34 KB
    Measurement Of PGMEA Using Photoionization Detectors
    application/pdf 750.69 KB
    7/15/2021
    750.69 KB
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Plus/AreaRAE Pro User Manual - EN
    application/pdf 18.88 MB
    5/7/2025
    18.88 MB
    Area RAE 1.12 Firmware and Release Notes
    application/zip 2.01 MB
    8/18/2023
    2.01 MB
    Honeywell AreaRAE Plus Datasheet - EN
    application/pdf 425.16 KB
    11/26/2025
    425.16 KB
    Honeywell AreaRAE Plus Datasheet - EN
    application/pdf 425.16 KB
    11/26/2025
    425.16 KB
    AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
    application/pdf 146.2 KB
    8/10/2022
    146.2 KB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    AreaRAE Plus/AreaRAE Pro QSG - EN
    application/pdf 1.81 MB
    5/7/2025
    1.81 MB
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    application/pdf 831.7 KB
    7/15/2021
    831.7 KB
    AreaRAE Plus Brochure
    application/pdf 3.23 MB
    7/15/2021
    3.23 MB
    Application Note 228 - Facility and Venue Protection
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    application/zip 1.57 MB
    5/20/2025
    1.57 MB
    AreaRAE Plus and Pro - Certificate of compliance
    application/pdf 45.13 KB
    9/27/2021
    45.13 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    Application Note 215: Gas Detection In The Marine Industries
    application/pdf 889.61 KB
    7/15/2021
    889.61 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    8/3/2022
    1.45 MB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    AreaRAE PlusPro Technical Note 106A
    application/pdf 428.08 KB
    7/15/2021
    428.08 KB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Technical Note 161 Intrinsic Safety And Hazardous Locations
    application/pdf 884.37 KB
    7/15/2021
    884.37 KB
    AreaRAE Plus and Pro - EU Declaration of Conformity
    application/pdf 154.78 KB
    1/11/2022
    154.78 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Technical Note 163 Addressing PID Instruments Moisture Sensitivity
    application/pdf 944.51 KB
    7/15/2021
    944.51 KB
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    application/pdf 787.55 KB
    7/15/2021
    787.55 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    RM2400A EU Component of Conformity to Certificates
    application/pdf 110.56 KB
    1/3/2022
    110.56 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    application/pdf 884.91 KB
    7/15/2021
    884.91 KB
    Technical Note 182 Basics of Wireless Security
    application/pdf 1.01 MB
    7/15/2021
    1.01 MB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    application/pdf 826.34 KB
    7/15/2021
    826.34 KB
    Measurement Of PGMEA Using Photoionization Detectors
    application/pdf 750.69 KB
    7/15/2021
    750.69 KB
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    application/pdf 949.42 KB
    7/15/2021
    949.42 KB
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    application/pdf 1.08 MB
    7/15/2021
    1.08 MB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
    application/pdf 194.1 KB
    1/11/2022
    194.1 KB
    Technical Note 167 Proper Use Of Dilution Fittings On Pumped Monitors
    application/pdf 1.02 MB
    7/15/2021
    1.02 MB
    Name
    Description
    File Size
    Date
    Size
    Honeywell AreaRAE Plus Datasheet - EN
    425.16 KB
    11/26/2025
    Honeywell AreaRAE Plus Datasheet - EN
    425.16 KB
    11/26/2025
    AreaRAE Plus/AreaRAE Pro User Manual - EN
    18.88 MB
    5/7/2025
    AreaRAE Plus/AreaRAE Pro QSG - EN
    1.81 MB
    5/7/2025
    Area RAE 1.12 Firmware and Release Notes
    2.01 MB
    8/18/2023
    1.57 MB
    5/20/2025
    AreaRAE Plus Brochure
    3.23 MB
    7/15/2021
    AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
    146.2 KB
    8/10/2022
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    814.89 KB
    7/15/2021
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    609.21 KB
    7/15/2021
    Technical Note 148 Defining The Interval Between Calibration Checks
    839.32 KB
    12/14/2022
    Technical Note 144 Handling LEL Sensor Poisons
    802.28 KB
    8/3/2022
    A Guideline for Pid Instrument Response
    1.45 MB
    8/3/2022
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    125.12 KB
    1/23/2024
    AreaRAE PlusPro Technical Note 106A
    428.08 KB
    7/15/2021
    Technical Note 161 Intrinsic Safety And Hazardous Locations
    884.37 KB
    7/15/2021
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    930.69 KB
    7/15/2021
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    1.09 MB
    2/8/2022
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    839.29 KB
    8/3/2022
    Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    950.72 KB
    7/15/2021
    Technical Note 163 Addressing PID Instruments Moisture Sensitivity
    944.51 KB
    7/15/2021
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    787.55 KB
    7/15/2021
    Technical Note 130 Setting Alarm Limits For Mixtures
    788.83 KB
    7/15/2021
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    795.02 KB
    7/15/2021
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    884.91 KB
    7/15/2021
    Technical Note 182 Basics of Wireless Security
    1.01 MB
    7/15/2021
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    1.08 MB
    7/15/2021
    Technical Note 169 Theory And Operation Of NDIR Sensors
    994.45 KB
    8/3/2022
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    911.54 KB
    7/15/2021
    Technical Note 167 Proper Use Of Dilution Fittings On Pumped Monitors
    1.02 MB
    7/15/2021
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    949.42 KB
    7/15/2021
    AreaRAE Plus and Pro - Certificate of compliance
    45.13 KB
    9/27/2021
    AreaRAE Plus and Pro - EU Declaration of Conformity
    154.78 KB
    1/11/2022
    RM2400A EU Component of Conformity to Certificates
    110.56 KB
    1/3/2022
    AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
    194.1 KB
    1/11/2022
    Application Note 203: PIDs As HazMat Response Tools
    1.26 MB
    7/15/2021
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    831.7 KB
    7/15/2021
    Application Note 228 - Facility and Venue Protection
    1.1 MB
    7/15/2021
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    1.07 MB
    7/15/2021
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    7/15/2021
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    655.59 KB
    7/15/2021
    Application Note 215: Gas Detection In The Marine Industries
    889.61 KB
    7/15/2021
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    964.88 KB
    7/15/2021
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    826.34 KB
    7/15/2021
    Measurement Of PGMEA Using Photoionization Detectors
    750.69 KB
    7/15/2021

    Filters

    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    701-0008-002
    CASE,PELICAN 1560 W FOAM,BLACK,AREARAE2
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
    701-0008-002
    CASE,PELICAN 1560 W FOAM,BLACK,AREARAE2
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
    W01-2013-000
    HANDLE COVER,AREARAE2
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
    W01-2013-000
    HANDLE COVER,AREARAE2
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
    W01-3025-000
    WATER TRAP CONNECTOR,AR2,PK OF 10,FOR SV
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
    W01-3025-000
    WATER TRAP CONNECTOR,AR2,PK OF 10,FOR SV
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
    W01B101002S9CDGQ00
    AR+CSAWI-FIPIDCO2COSO2NOHCNHCL
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
    W01B101002S9CDGQ00
    AR+CSAWI-FIPIDCO2COSO2NOHCNHCL
    https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square