Products
Products
News and Events
Part Numbers
General Content
/content/sps/us/en/search-results.html

Transportable Area Monitoring

AreaRAE Plus

Transportable area monitor for multiple threat detection

Overview
AreaRAE_Plus_Square
The AreaRAE Plus provides superior detection of toxic and combustible gases, VOCs and wind speed, direction and humidity—all in one easy-to configure device. Plus, you’ll have vital details about threats happening in real-time—arming you with the information you need to act quickly.Features and Benefits:
  • Monitors up to seven threats, including VOCs, combustibles, Toxics and Oxygen
  • Optional meteorological sensor for tracking toxic plumes
  • 7R+ photoionization detector (PID) for monitoring VOCs at parts per million
  • Secondary radio module (Mesh) act as an communication Hub for other wireless devices
  • Ruggedized, portable, and weather-resistant design for harsh environments
  • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations
Application:
  • Confined Space Entry
  • Environmental Cleanups/ Remediation
  • Fence Line Monitoring
  • Leak Detection
  • Plant Shutdown & Turn-Around
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Overview

  • Brand
    • RAE
  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Features

  • Sub-Category
    • Transportable
  • Alarm Type
    • Audible, Visual, Vibrating
  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Features & Benefits
    • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
  • User Options
    • 3 operation and programming keys
  • Wireless Technology
    • BLE, MESH, WiFi, LORA

Dimensions & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Technical Specifications

  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Humidity Range
    • 0%-95%
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3

Battery & Charging

  • Battery Run Time
    • 20

Standards & Certifications

  • Standards
    • US and Canada: Class 1, Division 2, Groups A, B, C, D
  • Ingress Protection
    • IP65

Others

  • Sampling Pump Range
    • 100ft (30m)
  • Weight
    • 14.33 US Pound
    • 6.5 kilogram
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 140 degree Fahrenheit
    • 60 degree Celsius

Overview

  • Brand
    • RAE
  • Warranty
    • Four years for O2 Liquid Oxygen sensors

Features

  • Sub-Category
    • Transportable
  • Alarm Type
    • Audible, Visual, Vibrating
  • Datalogging
    • Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Features & Benefits
    • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
  • User Options
    • 3 operation and programming keys
  • Wireless Technology
    • BLE, MESH, WiFi, LORA

Dimensions & Weight

  • Instrument Size
    • 12.36” x 12.04” x 6.53”

Technical Specifications

  • Sensor Range
    • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Humidity Range
    • 0%-95%
  • Gas Type
    • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3

Battery & Charging

  • Battery Run Time
    • 20

Standards & Certifications

  • Standards
    • US and Canada: Class 1, Division 2, Groups A, B, C, D
  • Ingress Protection
    • IP65

Others

  • Sampling Pump Range
    • 100ft (30m)
  • Weight
    • 14.33 US Pound
    • 6.5 kilogram
  • Minimum Temperature
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 140 degree Fahrenheit
    • 60 degree Celsius
  • Brand : RAE
  • Sampling Pump Range : 100ft (30m)
  • Weight : 14.33 US Pound|6.5 kilogram
  • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
  • Maximum Temperature : 140 degree Fahrenheit|60 degree Celsius
  • Sub-Category : Transportable
  • Instrument Size : 12.36” x 12.04” x 6.53”
  • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm)
  • Humidity Range : 0%-95%
  • Alarm Type : Audible, Visual, Vibrating
  • Battery Run Time : 20
  • Standards : US and Canada: Class 1, Division 2, Groups A, B, C, D
  • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
  • Features & Benefits : Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
  • User Options : 3 operation and programming keys
  • Warranty : Four years for O2 Liquid Oxygen sensors
  • Wireless Technology : BLE, MESH, WiFi, LORA
  • Ingress Protection : IP65
  • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3
Data Sheet
Name
Description
File Size
Date
Size
AreaRAE Plus Datasheet
application/pdf 569.87 KB
7/15/2021
569.87 KB
Manuals and Guides
Name
Description
File Size
Date
Size
AreaRAE Plus/AreaRAE Pro QSG - EN
application/pdf 1.81 MB
5/7/2025
1.81 MB
AreaRAE Plus/AreaRAE Pro User Manual - EN
application/pdf 18.88 MB
5/7/2025
18.88 MB
Firmware
Name
Description
File Size
Date
Size
Area RAE 1.12 Firmware and Release Notes
application/zip 2.01 MB
8/18/2023
2.01 MB
application/zip 1.57 MB
5/20/2025
1.57 MB
Brochure
Name
Description
File Size
Date
Size
AreaRAE Plus Brochure
application/pdf 3.23 MB
7/15/2021
3.23 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
2/8/2022
1.09 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
AreaRAE PlusPro Technical Note 106A
application/pdf 428.08 KB
7/15/2021
428.08 KB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
7/15/2021
884.91 KB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
7/15/2021
1.01 MB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
application/pdf 146.2 KB
8/10/2022
146.2 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 144 Handling LEL Sensor Poisons
application/pdf 802.28 KB
8/3/2022
802.28 KB
Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
7/15/2021
1.08 MB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
application/pdf 1.02 MB
7/15/2021
1.02 MB
White Paper
Name
Description
File Size
Date
Size
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
7/15/2021
949.42 KB
Certificate
Name
Description
File Size
Date
Size
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
AreaRAE Plus and Pro - EU Declaration of Conformity
application/pdf 154.78 KB
1/11/2022
154.78 KB
AreaRAE Plus and Pro - Certificate of compliance
application/pdf 45.13 KB
9/27/2021
45.13 KB
AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
application/pdf 194.1 KB
1/11/2022
194.1 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Measurement Of PGMEA Using Photoionization Detectors
application/pdf 750.69 KB
7/15/2021
750.69 KB
Application Note 215: Gas Detection In The Marine Industries
application/pdf 889.61 KB
7/15/2021
889.61 KB
Application Note 228 - Facility and Venue Protection
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
7/15/2021
1.07 MB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
7/15/2021
831.7 KB
Name
Description
File Size
Date
Size
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
AreaRAE Plus and Pro - EU Declaration of Conformity
application/pdf 154.78 KB
1/11/2022
154.78 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Measurement Of PGMEA Using Photoionization Detectors
application/pdf 750.69 KB
7/15/2021
750.69 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
2/8/2022
1.09 MB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
AreaRAE PlusPro Technical Note 106A
application/pdf 428.08 KB
7/15/2021
428.08 KB
AreaRAE Plus/AreaRAE Pro QSG - EN
application/pdf 1.81 MB
5/7/2025
1.81 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
Area RAE 1.12 Firmware and Release Notes
application/zip 2.01 MB
8/18/2023
2.01 MB
Application Note 215: Gas Detection In The Marine Industries
application/pdf 889.61 KB
7/15/2021
889.61 KB
Application Note 228 - Facility and Venue Protection
application/pdf 1.1 MB
7/15/2021
1.1 MB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
AreaRAE Plus/AreaRAE Pro User Manual - EN
application/pdf 18.88 MB
5/7/2025
18.88 MB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
Technical Note 159 Chemical Warfare Agent Measurements By PID
application/pdf 884.91 KB
7/15/2021
884.91 KB
Technical Note 182 Basics of Wireless Security
application/pdf 1.01 MB
7/15/2021
1.01 MB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
application/pdf 146.2 KB
8/10/2022
146.2 KB
AreaRAE Plus and Pro - Certificate of compliance
application/pdf 45.13 KB
9/27/2021
45.13 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
7/15/2021
1.07 MB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
application/pdf 949.42 KB
7/15/2021
949.42 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Technical Note 144 Handling LEL Sensor Poisons
application/pdf 802.28 KB
8/3/2022
802.28 KB
application/zip 1.57 MB
5/20/2025
1.57 MB
Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Application Note 205 - Measuring Heat Transfer Fluids With A PID
application/pdf 831.7 KB
7/15/2021
831.7 KB
AreaRAE Plus Brochure
application/pdf 3.23 MB
7/15/2021
3.23 MB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
application/pdf 1.08 MB
7/15/2021
1.08 MB
AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
application/pdf 194.1 KB
1/11/2022
194.1 KB
Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
application/pdf 1.02 MB
7/15/2021
1.02 MB
AreaRAE Plus Datasheet
application/pdf 569.87 KB
7/15/2021
569.87 KB
Name
Date
Size
5/20/2025
Showing 1 to 1 of 1 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
701-0008-002
CASE,PELICAN 1560 W FOAM,BLACK,AREARAE2
https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
701-0008-002
CASE,PELICAN 1560 W FOAM,BLACK,AREARAE2
https://s7d1.scene7.com/is/image/Honeywell65/AreaRAE_Plus_Square
Feedback