/content/sps/us/en/search-results.html

    Multi-Gas

    MultiRAE Lite Diffused

    Wireless, portable multi-gas monitor

    Overview
    This multi-gas monitor provides versatile, customizable detection and monitoring of up to six gases, available in both pumped and diffused air models. With more than 25 sensors to choose from — the broadest selection in its class — it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a range of industries and applications. The wireless connection sends threat and alarm data in real time to a central command, providing superior awareness for fast incident response. And its replaceable sensors, alarm, and battery, large screen, and automated bump testing and calibration make it easy to use and maintain.Features and Benefits:• Multi-gas monitor for 1-6 gases• Pumped and diffusion models available• Man down alarm• More than 25 different chemical sensors• Fully automatic bump testing and calibration• Real-time access to readings at central command• Swap out sensors as needed• Simple maintenance with replaceable sensors, pump, and battery• 5-way local and remote wireless alarm• Multi-language capability – up to 18 languagesApplication:• Clandestine Labs• Confined Space Entry• Emergency Response• Environmental Cleanups/ Remediation• Exploration• Fire Overhaul• Fracking• Hazmat Response• Plant Shutdown & Turn-Around• Urban Search & Rescue
    Specifications

    Brand

    • Brand
      • RAE

    Dimension & Weight

    • Weight
      • 880 ounce av
      • 880 gram
    • Instrument Size
      • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

    Temperature

    • Minimum Temperature
      • -20 degree Fahrenheit
      • -20 degree Celsius
    • Maximum Temperature
      • 50 degree Celsius
      • 50 degree Fahrenheit

    Category

    • Sub-Category
      • Multi-Gas

    Range

    • Sensor Range
      • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
      • NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating
      • Audible- Visual- Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-18 hours

    Certifications

    • Standards & Certifications
      • CSA: Class I, Division 1, Groups A, B, C, and D, T4
      • CSA: Class I- Division 1- Groups A- B- C- and D- T4

    Datalogging

    • Datalogging
      • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
      • Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)

    Features & Benefits

    • Features & Benefits
      • Highly versatile and customizable

    Options

    • User Options
      • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
      • 3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • Four years on Liq O2 sensors

    Wireless

    • Wireless Technology
      • BLE

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
      • NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2

    Brand

    • Brand
      • RAE

    Dimension & Weight

    • Weight
      • 880 ounce av
      • 880 gram
    • Instrument Size
      • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

    Temperature

    • Minimum Temperature
      • -20 degree Fahrenheit
      • -20 degree Celsius
    • Maximum Temperature
      • 50 degree Celsius
      • 50 degree Fahrenheit

    Category

    • Sub-Category
      • Multi-Gas

    Range

    • Sensor Range
      • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
      • NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating
      • Audible- Visual- Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-18 hours

    Certifications

    • Standards & Certifications
      • CSA: Class I, Division 1, Groups A, B, C, and D, T4
      • CSA: Class I- Division 1- Groups A- B- C- and D- T4

    Datalogging

    • Datalogging
      • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
      • Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)

    Features & Benefits

    • Features & Benefits
      • Highly versatile and customizable

    Options

    • User Options
      • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
      • 3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • Four years on Liq O2 sensors

    Wireless

    • Wireless Technology
      • BLE

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
      • NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2
    • Brand : RAE|
    • Weight : 880 ounce av|880 gram|
    • Minimum Temperature : -20 degree Fahrenheit|-20 degree Celsius|
    • Maximum Temperature : 50 degree Celsius|50 degree Fahrenheit|
    • Sub-Category : Multi-Gas|
    • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]|
    • Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)|NH3 (0-100ppm)- CO (0-2000ppm)- H2S (0-200ppm)- CL2 (0-50ppm)- CLO2 (0-1ppm)- ETO (0-100ppm)- HCHO (0-10ppm)- HCN (0-50ppm)- CH3-SH (0-10ppm)- NO (0-250ppm)- NO2 (0-20ppm)- O2 (0-30%vol)- PH3 (0-20ppm)- SO2 (0-20ppm)- VOC (0-5000ppm)- LEL (0-100%LEL)- CO2 (0-50000ppm)|
    • Humidity Range : 0%-95% percent|
    • Alarm Type : Audible, Visual, Vibrating|Audible- Visual- Vibrating|
    • Battery Run Time : 12-18 hours|
    • Standards & Certifications : CSA: Class I, Division 1, Groups A, B, C, and D, T4|CSA: Class I- Division 1- Groups A- B- C- and D- T4|
    • Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)|Continuous datalogging (6 months for 5 sensors at 1-minute intervals- 24/7)|
    • Features & Benefits : Highly versatile and customizable|
    • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected|3 operation and programming keys (Mode- Y/+- and N/-). Multiple User Options can be selected|
    • Sampling Pump Range : 100ft (30m) meter|
    • Warranty : Four years on Liq O2 sensors|
    • Wireless Technology : BLE|
    • Ingress Protection : IP65|
    • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2|NH3- CO- H2S- CL2- CLO2- ETO- HCHO- HCN-CH3-SH- NO- NO2- O2- PH3- SO2- VOC- LEL- CO2|
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    MultiRAE Lite Diffused & Pumped Data Sheet
    application/pdf 138.55 KB
    10/5/2023
    138.55 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    MultiRAE Lite Diffusion QuickStart Guide
    application/pdf 339.26 KB
    10/5/2023
    339.26 KB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 610.55 KB
    10/5/2023
    610.55 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 912.47 KB
    10/5/2023
    912.47 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 796.74 KB
    10/5/2023
    796.74 KB
    MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
    application/pdf 126.69 KB
    10/5/2023
    126.69 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 790.02 KB
    10/5/2023
    790.02 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.95 KB
    10/5/2023
    750.95 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.89 KB
    10/5/2023
    785.89 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 840.24 KB
    10/5/2023
    840.24 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    10/5/2023
    1.45 MB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 821.9 KB
    10/5/2023
    821.9 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 995.19 KB
    10/5/2023
    995.19 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 218: Measurement Of Fumigants In The Food Storage Industry
    application/pdf 902.09 KB
    10/5/2023
    902.09 KB
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces
    application/pdf 1 MB
    10/5/2023
    1 MB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 656.89 KB
    10/5/2023
    656.89 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    10/5/2023
    1.1 MB
    Application 202: The ABC®s Of Gases In The Industry
    application/pdf 844.27 KB
    10/5/2023
    844.27 KB
    Name
    Description
    File Size
    Date
    Size
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 610.55 KB
    10/5/2023
    610.55 KB
    Application Note 218: Measurement Of Fumigants In The Food Storage Industry
    application/pdf 902.09 KB
    10/5/2023
    902.09 KB
    MultiRAE Lite Diffusion QuickStart Guide
    application/pdf 339.26 KB
    10/5/2023
    339.26 KB
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces
    application/pdf 1 MB
    10/5/2023
    1 MB
    MultiRAE Lite Diffused & Pumped Data Sheet
    application/pdf 138.55 KB
    10/5/2023
    138.55 KB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 656.89 KB
    10/5/2023
    656.89 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 912.47 KB
    10/5/2023
    912.47 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 796.74 KB
    10/5/2023
    796.74 KB
    MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
    application/pdf 126.69 KB
    10/5/2023
    126.69 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 790.02 KB
    10/5/2023
    790.02 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    10/5/2023
    1.1 MB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.95 KB
    10/5/2023
    750.95 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Application 202: The ABC®s Of Gases In The Industry
    application/pdf 844.27 KB
    10/5/2023
    844.27 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.89 KB
    10/5/2023
    785.89 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 840.24 KB
    10/5/2023
    840.24 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    10/5/2023
    1.45 MB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 821.9 KB
    10/5/2023
    821.9 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    application/pdf 750.26 KB
    11/1/2022
    750.26 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 995.19 KB
    10/5/2023
    995.19 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Name
    Description
    File Size
    Date
    Size
    MultiRAE Lite Diffused & Pumped Data Sheet
    138.55 KB
    10/5/2023
    MultiRAE Lite Diffusion QuickStart Guide
    339.26 KB
    10/5/2023
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    610.55 KB
    10/5/2023
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    912.47 KB
    10/5/2023
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    796.74 KB
    10/5/2023
    MultiRAE Benzene,MeshGuard EC,AreaRAE Pro,MultiRAE Lite Pumped,QRAE 3,ToxiRAE Pro,MultiRAE,MultiRAE Pro,AreaRAE Plus,MultiRAE Lite Diffused Product Notice
    126.69 KB
    10/5/2023
    Technical Note 130 Setting Alarm Limits For Mixtures
    790.02 KB
    10/5/2023
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    750.26 KB
    11/1/2022
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    750.95 KB
    10/5/2023
    Technical Note 169 Theory And Operation Of NDIR Sensors
    994.45 KB
    8/3/2022
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    750.26 KB
    11/1/2022
    Technical Note 169 Theory And Operation Of NDIR Sensors
    994.45 KB
    8/3/2022
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Technical Note 169 Theory And Operation Of NDIR Sensors
    994.45 KB
    8/3/2022
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    750.26 KB
    11/1/2022
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.89 KB
    10/5/2023
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    839.29 KB
    8/3/2022
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    839.29 KB
    8/3/2022
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    11/1/2022
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    839.29 KB
    8/3/2022
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    839.29 KB
    8/3/2022
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    840.24 KB
    10/5/2023
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    11/1/2022
    A Guideline for Pid Instrument Response
    1.45 MB
    10/5/2023
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    11/1/2022
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    11/1/2022
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    821.9 KB
    10/5/2023
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
    750.26 KB
    11/1/2022
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Technical Note 169 Theory And Operation Of NDIR Sensors
    995.19 KB
    10/5/2023
    Technical Note 169 Theory And Operation Of NDIR Sensors
    994.45 KB
    8/3/2022
    Application Note 218: Measurement Of Fumigants In The Food Storage Industry
    902.09 KB
    10/5/2023
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces
    1 MB
    10/5/2023
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    656.89 KB
    10/5/2023
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    10/5/2023
    Application 202: The ABC®s Of Gases In The Industry
    844.27 KB
    10/5/2023
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list