/content/sps/us/en/search-results.html

    Multi-Gas

    MultiRAE Pro

    Overview
    Specifications

    Brand

    • Brand
      • RAE

    Category

    • Sub-Category
      • Premium-Gas

    Dimension & Weight

    • Instrument Size
      • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

    Range

    • Sensor Range
      • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-18 hours

    Certifications

    • Standards & Certifications
      • Class I, Division 1, Groups A, B, C, D, T4

    Datalogging

    • Datalogging
      • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)

    Features & Benefits

    • Features & Benefits
      • Highly versatile and customizable

    Options

    • User Options
      • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • Four years on Liq O2 sensors

    Wireless

    • Wireless Technology
      • MESH, Wifi, BLE

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2

    Others

    • Maximum Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius
    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 31 ounce av
      • 880 gram

    Brand

    • Brand
      • RAE

    Category

    • Sub-Category
      • Premium-Gas

    Dimension & Weight

    • Instrument Size
      • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

    Range

    • Sensor Range
      • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-18 hours

    Certifications

    • Standards & Certifications
      • Class I, Division 1, Groups A, B, C, D, T4

    Datalogging

    • Datalogging
      • Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)

    Features & Benefits

    • Features & Benefits
      • Highly versatile and customizable

    Options

    • User Options
      • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • Four years on Liq O2 sensors

    Wireless

    • Wireless Technology
      • MESH, Wifi, BLE

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2

    Others

    • Maximum Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius
    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 31 ounce av
      • 880 gram
    • Brand : RAE
    • Maximum Temperature : 122 degree Fahrenheit|50 degree Celsius
    • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
    • Weight : 31 ounce av|880 gram
    • Sub-Category : Premium-Gas
    • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
    • Sensor Range : NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
    • Humidity Range : 0%-95% percent
    • Alarm Type : Audible, Visual, Vibrating
    • Battery Run Time : 12-18 hours
    • Standards & Certifications : Class I, Division 1, Groups A, B, C, D, T4
    • Datalogging : Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
    • Features & Benefits : Highly versatile and customizable
    • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • Sampling Pump Range : 100ft (30m) meter
    • Warranty : Four years on Liq O2 sensors
    • Wireless Technology : MESH, Wifi, BLE
    • Ingress Protection : IP65
    • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    MultiRAE Pro Data Sheet
    application/pdf 127.65 KB
    7/15/2021
    127.65 KB
    VOC ZeroingTube Data Sheet
    application/pdf 77.52 KB
    7/15/2021
    77.52 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    MultiRAE User Manual - UK
    application/pdf 13.84 MB
    5/10/2024
    13.84 MB
    MultiRAE User Manual - KO
    application/pdf 14.01 MB
    5/8/2024
    14.01 MB
    MultiRAE User Manual - JP
    application/pdf 14.13 MB
    5/8/2024
    14.13 MB
    MultiRAE User Manual - IT
    application/pdf 13.73 MB
    5/8/2024
    13.73 MB
    MultiRAE User Manual - FR
    application/pdf 13.77 MB
    5/7/2024
    13.77 MB
    MultiRAE User Manual - ES
    application/pdf 13.74 MB
    5/7/2024
    13.74 MB
    MultiRAE User Manual - DE
    application/pdf 13.71 MB
    5/7/2024
    13.71 MB
    MultiRAE (Diffusion) Quick Reference Guide
    application/pdf 595.58 KB
    12/13/2023
    595.58 KB
    MultiRAE (Pumped Models) User's Guide - EN
    application/pdf 898.78 KB
    11/15/2023
    898.78 KB
    MultiRAE (Pumped) QuickStart Guide
    application/pdf 302.5 KB
    7/15/2021
    302.5 KB
    Software
    Name
    Description
    File Size
    Date
    Size
    MultiRAE Application Firmware V 1.56.006 with signature
    application/zip 1.4 MB
    1/4/2024
    1.4 MB
    MultiRAE Sensor Firmware V 1.56.006 with signature
    application/zip 264.62 KB
    1/4/2024
    264.62 KB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    MSI-Honeywell Connected Safety Solution
    application/pdf 441.3 KB
    7/15/2021
    441.3 KB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 176 Basics Of Nuclear Radiation
    application/pdf 1.31 MB
    7/15/2021
    1.31 MB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/15/2021
    926.7 KB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    9/14/2022
    820.7 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    7/15/2021
    790.79 KB
    MultiRAE Series Technical Note 106B
    application/pdf 620.4 KB
    7/15/2021
    620.4 KB
    Certificate
    Name
    Description
    File Size
    Date
    Size
    MultiRAE - INMETRO Certificate of Conformity
    application/pdf 472.03 KB
    4/24/2023
    472.03 KB
    RM2400A EU Component of Conformity to Certificates
    application/pdf 110.56 KB
    1/3/2022
    110.56 KB
    Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
    application/pdf 817.01 KB
    7/15/2021
    817.01 KB
    MultiRAE - Atex SIra EU Type Exam Certification
    application/pdf 310.08 KB
    1/7/2022
    310.08 KB
    ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
    application/pdf 116.75 KB
    1/3/2022
    116.75 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    TN-204 Modes & Applications For The MultiRAE Benzene Application Note
    application/pdf 226.06 KB
    7/15/2021
    226.06 KB
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
    application/pdf 941.33 KB
    8/4/2022
    941.33 KB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    7/15/2021
    836.36 KB
    Name
    Description
    File Size
    Date
    Size
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    MultiRAE User Manual - UK
    application/pdf 13.84 MB
    5/10/2024
    13.84 MB
    MultiRAE User Manual - KO
    application/pdf 14.01 MB
    5/8/2024
    14.01 MB
    MultiRAE User Manual - JP
    application/pdf 14.13 MB
    5/8/2024
    14.13 MB
    MultiRAE User Manual - IT
    application/pdf 13.73 MB
    5/8/2024
    13.73 MB
    MultiRAE User Manual - FR
    application/pdf 13.77 MB
    5/7/2024
    13.77 MB
    MultiRAE User Manual - ES
    application/pdf 13.74 MB
    5/7/2024
    13.74 MB
    MultiRAE User Manual - DE
    application/pdf 13.71 MB
    5/7/2024
    13.71 MB
    MultiRAE Application Firmware V 1.56.006 with signature
    application/zip 1.4 MB
    1/4/2024
    1.4 MB
    MultiRAE Sensor Firmware V 1.56.006 with signature
    application/zip 264.62 KB
    1/4/2024
    264.62 KB
    MultiRAE (Diffusion) Quick Reference Guide
    application/pdf 595.58 KB
    12/13/2023
    595.58 KB
    MultiRAE (Pumped Models) User's Guide - EN
    application/pdf 898.78 KB
    11/15/2023
    898.78 KB
    MultiRAE - INMETRO Certificate of Conformity
    application/pdf 472.03 KB
    4/24/2023
    472.03 KB
    Technical Note 176 Basics Of Nuclear Radiation
    application/pdf 1.31 MB
    7/15/2021
    1.31 MB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    TN-204 Modes & Applications For The MultiRAE Benzene Application Note
    application/pdf 226.06 KB
    7/15/2021
    226.06 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
    application/pdf 941.33 KB
    8/4/2022
    941.33 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    RM2400A EU Component of Conformity to Certificates
    application/pdf 110.56 KB
    1/3/2022
    110.56 KB
    MultiRAE Pro Data Sheet
    application/pdf 127.65 KB
    7/15/2021
    127.65 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
    application/pdf 817.01 KB
    7/15/2021
    817.01 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    MSI-Honeywell Connected Safety Solution
    application/pdf 441.3 KB
    7/15/2021
    441.3 KB
    MultiRAE (Pumped) QuickStart Guide
    application/pdf 302.5 KB
    7/15/2021
    302.5 KB
    MultiRAE - Atex SIra EU Type Exam Certification
    application/pdf 310.08 KB
    1/7/2022
    310.08 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/15/2021
    926.7 KB
    VOC ZeroingTube Data Sheet
    application/pdf 77.52 KB
    7/15/2021
    77.52 KB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    9/14/2022
    820.7 KB
    ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
    application/pdf 116.75 KB
    1/3/2022
    116.75 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    7/15/2021
    836.36 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    7/15/2021
    790.79 KB
    MultiRAE Series Technical Note 106B
    application/pdf 620.4 KB
    7/15/2021
    620.4 KB
    Name
    Description
    File Size
    Date
    Size
    MultiRAE Pro Data Sheet
    127.65 KB
    7/15/2021
    VOC ZeroingTube Data Sheet
    77.52 KB
    7/15/2021
    MultiRAE User Manual - UK
    13.84 MB
    5/10/2024
    MultiRAE User Manual - KO
    14.01 MB
    5/8/2024
    MultiRAE User Manual - JP
    14.13 MB
    5/8/2024
    MultiRAE User Manual - IT
    13.73 MB
    5/8/2024
    MultiRAE User Manual - FR
    13.77 MB
    5/7/2024
    MultiRAE User Manual - ES
    13.74 MB
    5/7/2024
    MultiRAE User Manual - DE
    13.71 MB
    5/7/2024
    MultiRAE (Diffusion) Quick Reference Guide
    595.58 KB
    12/13/2023
    MultiRAE (Pumped Models) User's Guide - EN
    898.78 KB
    11/15/2023
    MultiRAE (Pumped) QuickStart Guide
    302.5 KB
    7/15/2021
    MultiRAE Application Firmware V 1.56.006 with signature
    1.4 MB
    1/4/2024
    MultiRAE Sensor Firmware V 1.56.006 with signature
    264.62 KB
    1/4/2024
    MSI-Honeywell Connected Safety Solution
    441.3 KB
    7/15/2021
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Technical Note 176 Basics Of Nuclear Radiation
    1.31 MB
    7/15/2021
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    950.72 KB
    7/15/2021
    Technical Note 148 Defining The Interval Between Calibration Checks
    839.32 KB
    12/14/2022
    Technical Note 130 Setting Alarm Limits For Mixtures
    788.83 KB
    7/15/2021
    Technical Note 169 Theory And Operation Of NDIR Sensors
    994.45 KB
    8/3/2022
    Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
    1.1 MB
    7/15/2021
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    930.69 KB
    7/15/2021
    Lithium-Ion Batteries Technical Note 166
    926.7 KB
    7/15/2021
    Technical Note 170 USB To Serial Port Adapter
    1.26 MB
    7/15/2021
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    911.54 KB
    7/15/2021
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    125.12 KB
    1/23/2024
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    9/14/2022
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    814.89 KB
    7/15/2021
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    790.79 KB
    7/15/2021
    MultiRAE Series Technical Note 106B
    620.4 KB
    7/15/2021
    MultiRAE - INMETRO Certificate of Conformity
    472.03 KB
    4/24/2023
    RM2400A EU Component of Conformity to Certificates
    110.56 KB
    1/3/2022
    Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
    817.01 KB
    7/15/2021
    MultiRAE - Atex SIra EU Type Exam Certification
    310.08 KB
    1/7/2022
    ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
    116.75 KB
    1/3/2022
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    655.59 KB
    7/15/2021
    TN-204 Modes & Applications For The MultiRAE Benzene Application Note
    226.06 KB
    7/15/2021
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
    941.33 KB
    8/4/2022
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    964.88 KB
    7/15/2021
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    7/15/2021
    Application Note 214: Environmental Applications For PIDs
    836.36 KB
    7/15/2021
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list

    Alternative Products