/content/sps/us/en/search-results.html

    fixed gas detectors

    XNX™ Universal Transmitter

    An extremely flexible transmitter that can be configured to accept a variety of Honeywell's range of gas sensor technologies

    Overview

    Supports the widest range of sensors on a common platform and offers a modular choice of inputs and outputs (saving customers time and money).

    Product Overview:

    XNX's advantage comes from a simple-to-use, low-maintenance universal platform that works with other safety equipment on a digital bus system, including Honeywell Analytics’ own Searchline Excel, Optima or other gas detectors, industry standard PLCs and third-party gas monitoring controllers.

    XNX supports Electrochemical, Infrared and Catalytic Bead gas monitors and uses standard 4-20mA wiring and HART: options include Modbus, Fieldbus (pending) up to three relays and a local Hart Adapter for configuration and diagnostics using existing HART handheld devices.

    With 200+ unique configurations, XNX satisfies Class 1/Class 2 intrinsically safe, explosion-proof requirements in upstream/downstream oil, chemical, wastewater and other industries.

    The enclosure is available in stainless steel or aluminum, with a marine-grade coating. Five threaded ports, available in metric or NPT versions, and ruggedized mounting options provide ultimate installation flexibility. Instrumentation built on various sensing technologies can be attached locally to the transmitter or remotely with the appropriate accessories.

    Features & Benefits:

    • Flammable gas detection 0 to 100% LFL/LEL
    • Flexible operation options
    • Minimal training required

    Quick Specs:

    • Material: LM25 aluminum, painted (SS316 painted optional)
    • Temperature: -40° to +65°C / -40° to +150°F (sensor dependent)
    • Humidity: 20 to 90% RH (non-condensing)

    Fire and Gas Consultancy Services

    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Dimension & Weight

    • Overall Width
      • 197 millimetre
    • Overall Height
      • 4.48 inch

    Certifications

    • Standards
      • ATEX
      • CSA
      • IECEx
      • UL Approved
      • cUL
    • Certifications - Regional
      • Canadian: CSA: Class I, Div 1, Groups B, C, and D; Class II, Div. 1 Groups F & G / Class I, Zone 1 Groups IIB + H2
      • European: ATEX: II 2 (1) G Ex d [ia IIC Ga] IIC T4/T6 Gb II 2 (1) D Ex tb [ia IIIC Da] IIIC T85 Db
      • International: IECEx: Ex d [ia IIC Ga] IIC T4/T6 Gb Ex tb [ia IIIC Da] IIIC T85 Db
      • North American: FM: AEx D [ia IIC] IIB + H2 T6 -40°C ≤Tamb ≤65°C
      • North American: UL: Class I, Div 1, Groups A, B, C, and D; Class II, Div. 1 Groups F & G / Class 1, Zone 1 Groups IIB + H2; Class II, Zone 20 & 21
    • Certifications - Performance
      • Europe: ATEX, EN45544, EN50104, EN50271:2010, EN13980, EN60079-29-1
      • North America: UL 913, UL 1203, CSA 22.2 No. 152 IEC61508 (SIL Assessment, SIL 2), IECEx OD 005
    • Certifications - Other
      • EMC: EN50270:2006 EN61000-6-4:2007
    • Certifications - Hazloc
      • ATEX/IECEx/INMETRO

    Display

    • Display Type
      • LCD

    Features & Benefits

    • Features & Benefits
      • Cost Effective
      • Easy to Use and Easy to Install
      • Flexible Operation
      • High Performance

    Options

    • For Use With
      • EC Sensor
      • Honeywell Analytics Range Gas Sensors

    Port

    • Digital Communication Ports
      • HART® Communications
      • MODBUS® and FOUNDATION® H1 Fieldbus

    Additional Specifications

    • Mounting Style
      • Surface

    Brand

    • Brand
      • Honeywell

    Others

    • Industry
      • Energy

    Dimension & Weight

    • Overall Width
      • 197 millimetre
    • Overall Height
      • 4.48 inch

    Certifications

    • Standards
      • ATEX
      • CSA
      • IECEx
      • UL Approved
      • cUL
    • Certifications - Regional
      • Canadian: CSA: Class I, Div 1, Groups B, C, and D; Class II, Div. 1 Groups F & G / Class I, Zone 1 Groups IIB + H2
      • European: ATEX: II 2 (1) G Ex d [ia IIC Ga] IIC T4/T6 Gb II 2 (1) D Ex tb [ia IIIC Da] IIIC T85 Db
      • International: IECEx: Ex d [ia IIC Ga] IIC T4/T6 Gb Ex tb [ia IIIC Da] IIIC T85 Db
      • North American: FM: AEx D [ia IIC] IIB + H2 T6 -40°C ≤Tamb ≤65°C
      • North American: UL: Class I, Div 1, Groups A, B, C, and D; Class II, Div. 1 Groups F & G / Class 1, Zone 1 Groups IIB + H2; Class II, Zone 20 & 21
    • Certifications - Performance
      • Europe: ATEX, EN45544, EN50104, EN50271:2010, EN13980, EN60079-29-1
      • North America: UL 913, UL 1203, CSA 22.2 No. 152 IEC61508 (SIL Assessment, SIL 2), IECEx OD 005
    • Certifications - Other
      • EMC: EN50270:2006 EN61000-6-4:2007
    • Certifications - Hazloc
      • ATEX/IECEx/INMETRO

    Display

    • Display Type
      • LCD

    Features & Benefits

    • Features & Benefits
      • Cost Effective
      • Easy to Use and Easy to Install
      • Flexible Operation
      • High Performance

    Options

    • For Use With
      • EC Sensor
      • Honeywell Analytics Range Gas Sensors

    Port

    • Digital Communication Ports
      • HART® Communications
      • MODBUS® and FOUNDATION® H1 Fieldbus

    Additional Specifications

    • Mounting Style
      • Surface

    Brand

    • Brand
      • Honeywell

    Others

    • Industry
      • Energy
    • Overall Width : 197 millimetre
    • Overall Height : 4.48 inch
    • Standards : ATEX|CSA|IECEx|UL Approved|cUL
    • Certifications - Regional : Canadian: CSA: Class I, Div 1, Groups B, C, and D; Class II, Div. 1 Groups F & G / Class I, Zone 1 Groups IIB + H2|European: ATEX: II 2 (1) G Ex d [ia IIC Ga] IIC T4/T6 Gb II 2 (1) D Ex tb [ia IIIC Da] IIIC T85 Db|International: IECEx: Ex d [ia IIC Ga] IIC T4/T6 Gb Ex tb [ia IIIC Da] IIIC T85 Db|North American: FM: AEx D [ia IIC] IIB + H2 T6 -40°C ≤Tamb ≤65°C|North American: UL: Class I, Div 1, Groups A, B, C, and D; Class II, Div. 1 Groups F & G / Class 1, Zone 1 Groups IIB + H2; Class II, Zone 20 & 21
    • Certifications - Performance : Europe: ATEX, EN45544, EN50104, EN50271:2010, EN13980, EN60079-29-1|North America: UL 913, UL 1203, CSA 22.2 No. 152 IEC61508 (SIL Assessment, SIL 2), IECEx OD 005
    • Certifications - Other : EMC: EN50270:2006 EN61000-6-4:2007
    • Certifications - Hazloc : ATEX/IECEx/INMETRO
    • Display Type : LCD
    • Features & Benefits : Cost Effective|Easy to Use and Easy to Install|Flexible Operation|High Performance
    • For Use With : EC Sensor|Honeywell Analytics Range Gas Sensors
    • Digital Communication Ports : HART® Communications|MODBUS® and FOUNDATION® H1 Fieldbus
    • Mounting Style : Surface
    • Brand : Honeywell
    • Industry : Energy
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    XNX™ Universal Transmitter Spec Data Sheet
    application/pdf 2.31 MB
    10/7/2021
    2.31 MB
    MPD Adapter Atex EC-Type Examination Certificate
    application/pdf 519.16 KB
    10/5/2023
    519.16 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    XNX™ Universal Transmitter - Safety Manual
    application/pdf 1.87 MB
    8/5/2022
    1.87 MB
    XNX™ Universal Transmitter User Manual
    application/pdf 2.62 MB
    10/5/2023
    2.62 MB
    XNX™ Universal Transmitter Relay Install Guide
    application/pdf 781 KB
    10/5/2023
    781 KB
    XNX™ Universal Transmitter Modbus Install Guide
    application/pdf 755.66 KB
    10/5/2023
    755.66 KB
    XNX™ Universal Transmitter Technical Manual
    application/pdf 2.88 MB
    10/5/2023
    2.88 MB
    XNX™ Universal Transmitter Manual
    application/pdf 2.64 MB
    10/5/2023
    2.64 MB
    Industrial Fixed Gas and Flame Detection Product Guide
    application/pdf 2.92 MB
    9/3/2025
    2.92 MB
    XNX Universal Transmitter - Technical Manual Rev. 19
    application/pdf 22.72 MB
    7/18/2025
    22.72 MB
    XNX Universal Transmitter - Technical Manual Rev. 16
    application/pdf 22.93 MB
    12/30/2022
    22.93 MB
    MPD User Manual
    application/pdf 1.18 MB
    1/5/2023
    1.18 MB
    Software
    Name
    Description
    File Size
    Date
    Size
    XNX™ Universal Transmitter - HART DD
    application/zip 289.08 KB
    8/5/2022
    289.08 KB
    XNX™ Universal Transmitter - HART DTM Toolkit
    application/zip 36.85 MB
    8/1/2024
    36.85 MB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    XNX Universal Transmitter Brochure EN
    application/pdf 2.78 MB
    10/5/2023
    2.78 MB
    XNX™ Universal Transmitter Engineering Specifications
    application/pdf 212.97 KB
    10/5/2023
    212.97 KB
    Certificate
    Name
    Description
    File Size
    Date
    Size
    XNX™ Universal Transmitter ATEX EC-Type Examination Certificate
    application/pdf 556.73 KB
    10/5/2023
    556.73 KB
    MPD Sensor IECEx Certificate of Conformity
    application/pdf 976.7 KB
    10/5/2023
    976.7 KB
    XNX™ Universal Transmitter IECEx Certificate of Conformity
    application/pdf 651.23 KB
    10/5/2023
    651.23 KB
    XNX™ Universal Transmitter Certificate of Conformity - PT
    application/pdf 729 KB
    10/5/2023
    729 KB
    XNX™ Universal Transmitter Type Examination Certificate
    application/pdf 821.49 KB
    10/5/2023
    821.49 KB
    XNX™ Universal Transmitter US Flame Certificate of Conformity
    application/pdf 236.02 KB
    10/5/2023
    236.02 KB
    XNX™ Universal Transmitter ATEX CE EU Declaration of Conformity
    application/pdf 371.4 KB
    10/5/2023
    371.4 KB
    XNX™ Universal Transmitter - EU Declaration of Conformity
    application/pdf 224.58 KB
    2/28/2023
    224.58 KB
    Name
    Description
    File Size
    Date
    Size
    XNX™ Universal Transmitter - Safety Manual
    application/pdf 1.87 MB
    8/5/2022
    1.87 MB
    XNX Universal Transmitter Brochure EN
    application/pdf 2.78 MB
    10/5/2023
    2.78 MB
    XNX™ Universal Transmitter ATEX EC-Type Examination Certificate
    application/pdf 556.73 KB
    10/5/2023
    556.73 KB
    XNX™ Universal Transmitter User Manual
    application/pdf 2.62 MB
    10/5/2023
    2.62 MB
    MPD Sensor IECEx Certificate of Conformity
    application/pdf 976.7 KB
    10/5/2023
    976.7 KB
    XNX™ Universal Transmitter Relay Install Guide
    application/pdf 781 KB
    10/5/2023
    781 KB
    XNX™ Universal Transmitter IECEx Certificate of Conformity
    application/pdf 651.23 KB
    10/5/2023
    651.23 KB
    XNX™ Universal Transmitter Spec Data Sheet
    application/pdf 2.31 MB
    10/7/2021
    2.31 MB
    XNX™ Universal Transmitter Certificate of Conformity - PT
    application/pdf 729 KB
    10/5/2023
    729 KB
    XNX™ Universal Transmitter Modbus Install Guide
    application/pdf 755.66 KB
    10/5/2023
    755.66 KB
    XNX™ Universal Transmitter Type Examination Certificate
    application/pdf 821.49 KB
    10/5/2023
    821.49 KB
    XNX™ Universal Transmitter US Flame Certificate of Conformity
    application/pdf 236.02 KB
    10/5/2023
    236.02 KB
    XNX™ Universal Transmitter ATEX CE EU Declaration of Conformity
    application/pdf 371.4 KB
    10/5/2023
    371.4 KB
    MPD Adapter Atex EC-Type Examination Certificate
    application/pdf 519.16 KB
    10/5/2023
    519.16 KB
    XNX™ Universal Transmitter Technical Manual
    application/pdf 2.88 MB
    10/5/2023
    2.88 MB
    XNX™ Universal Transmitter Manual
    application/pdf 2.64 MB
    10/5/2023
    2.64 MB
    XNX™ Universal Transmitter Engineering Specifications
    application/pdf 212.97 KB
    10/5/2023
    212.97 KB
    Industrial Fixed Gas and Flame Detection Product Guide
    application/pdf 2.92 MB
    9/3/2025
    2.92 MB
    XNX Universal Transmitter - Technical Manual Rev. 19
    application/pdf 22.72 MB
    7/18/2025
    22.72 MB
    XNX™ Universal Transmitter - EU Declaration of Conformity
    application/pdf 224.58 KB
    2/28/2023
    224.58 KB
    XNX Universal Transmitter - Technical Manual Rev. 16
    application/pdf 22.93 MB
    12/30/2022
    22.93 MB
    MPD User Manual
    application/pdf 1.18 MB
    1/5/2023
    1.18 MB
    XNX™ Universal Transmitter - HART DD
    application/zip 289.08 KB
    8/5/2022
    289.08 KB
    XNX™ Universal Transmitter - HART DTM Toolkit
    application/zip 36.85 MB
    8/1/2024
    36.85 MB
    Name
    Description
    File Size
    Date
    Size
    XNX™ Universal Transmitter Spec Data Sheet
    2.31 MB
    10/7/2021
    MPD Adapter Atex EC-Type Examination Certificate
    519.16 KB
    10/5/2023
    XNX™ Universal Transmitter - Safety Manual
    1.87 MB
    8/5/2022
    XNX™ Universal Transmitter User Manual
    2.62 MB
    10/5/2023
    XNX™ Universal Transmitter Relay Install Guide
    781 KB
    10/5/2023
    XNX™ Universal Transmitter Modbus Install Guide
    755.66 KB
    10/5/2023
    XNX™ Universal Transmitter Technical Manual
    2.88 MB
    10/5/2023
    XNX™ Universal Transmitter Manual
    2.64 MB
    10/5/2023
    Industrial Fixed Gas and Flame Detection Product Guide
    2.92 MB
    9/3/2025
    XNX Universal Transmitter - Technical Manual Rev. 19
    22.72 MB
    7/18/2025
    XNX Universal Transmitter - Technical Manual Rev. 16
    22.93 MB
    12/30/2022
    MPD User Manual
    1.18 MB
    1/5/2023
    XNX™ Universal Transmitter - HART DD
    289.08 KB
    8/5/2022
    XNX™ Universal Transmitter - HART DTM Toolkit
    36.85 MB
    8/1/2024
    XNX Universal Transmitter Brochure EN
    2.78 MB
    10/5/2023
    XNX™ Universal Transmitter Engineering Specifications
    212.97 KB
    10/5/2023
    XNX™ Universal Transmitter ATEX EC-Type Examination Certificate
    556.73 KB
    10/5/2023
    MPD Sensor IECEx Certificate of Conformity
    976.7 KB
    10/5/2023
    XNX™ Universal Transmitter IECEx Certificate of Conformity
    651.23 KB
    10/5/2023
    XNX™ Universal Transmitter Certificate of Conformity - PT
    729 KB
    10/5/2023
    XNX™ Universal Transmitter Type Examination Certificate
    821.49 KB
    10/5/2023
    XNX™ Universal Transmitter US Flame Certificate of Conformity
    236.02 KB
    10/5/2023
    XNX™ Universal Transmitter ATEX CE EU Declaration of Conformity
    371.4 KB
    10/5/2023
    XNX™ Universal Transmitter - EU Declaration of Conformity
    224.58 KB
    2/28/2023

    Filters

    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    0060-1051
    BEAD FERRITE MV XNX
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    0060-1051
    BEAD FERRITE MV XNX
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    02104-N-XMSA
    XNX Excel line-of-sight gas detection system, medium range (40 to 120m), 4 to 20mA and HART® outputs, ATEXIECEx, fully wired with flexible conduit, electro polished 316SS.
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    02104-N-XMSA
    XNX Excel line-of-sight gas detection system, medium range (40 to 120m), 4 to 20mA and HART® outputs, ATEXIECEx, fully wired with flexible conduit, electro polished 316SS.
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    0235-0238
    XNX O-Ring W 0.139 OD 4.887
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    0235-0238
    XNX O-Ring W 0.139 OD 4.887
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0254
    Magnetic WandScrewdriver
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0254
    Magnetic WandScrewdriver
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0257
    M25 Stopping Plug w protective cap (stainless steel)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-socket-accessories-3-primaryimage
    1226-0257
    M25 Stopping Plug w protective cap (stainless steel)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-socket-accessories-3-primaryimage
    1226-0258
    34 NPT Stopping Plug w protective cap (stainless steel)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-socket-accessories-3-primaryimage
    1226-0258
    34 NPT Stopping Plug w protective cap (stainless steel)
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-socket-accessories-3-primaryimage
    1226-0299
    IR SENSOR ELEMENT 5% VOL METHANE
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0299
    IR SENSOR ELEMENT 5% VOL METHANE
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0300
    IR SENSOR ELEMENT LEL FLAMABLE
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0300
    IR SENSOR ELEMENT LEL FLAMABLE
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0301
    IR SENSOR ELEMENT 5% VOL CARBON DIOXIDE
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0301
    IR SENSOR ELEMENT 5% VOL CARBON DIOXIDE
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0350
    Sensor retainer, includes set screw (SS cover for EC sensor)
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter
    1226-0350
    Sensor retainer, includes set screw (SS cover for EC sensor)
    https://s7d1.scene7.com/is/image/Honeywell65/XNX_Universal_Transmitter