Overview
RAEGuard-2-PID_Full-front-view_clr-bkg

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs)

Product Overview:

RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.

The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.

Features & Benefits:

  • Faster response time - Thanks to the sample flow-through design
  • Reduce maintenance cost - Easy to remove sensor module in hazardous locations without using of tools
  • No false alarms - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution

Quick Specs:

  • Digital Smart Sensor Technology
  • Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm
  • Operates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output
  • Graphic display and LED light status indicator for fault and alarm conditions

Fire and Gas Consultancy Services

Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Overview

  • Brand
    • RAE

Features

  • Sub-Category
    • Gas Detection Sensors & Transmitters

Overview

  • Brand
    • RAE

Features

  • Sub-Category
    • Gas Detection Sensors & Transmitters
  • Brand : RAE
  • Sub-Category : Gas Detection Sensors & Transmitters
Data Sheet
Name
Description
File Size
Date
Size
RAEGuard 2 PID Data Sheet
application/pdf 406.17 KB
7/15/2021
406.17 KB
Manuals and Guides
Name
Description
File Size
Date
Size
RAEGuard 2 PID User Guide Rev-R ENG
application/pdf 3.76 MB
7/7/2022
3.76 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
7/15/2021
820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Certificate
Name
Description
File Size
Date
Size
RAEGuard 2 (FGM 2xxx) EU Declaration of Conformity
application/pdf 201.56 KB
1/6/2022
201.56 KB
EU & UK Declaration of Conformity RAEGuard 2
application/pdf 557.92 KB
7/25/2023
557.92 KB
RAEGuard 2 PID EU Declaration of Conformity
application/pdf 201.56 KB
2/4/2022
201.56 KB
RAEGuard 2 PID DigiPID ATEX CE EU Declaration of Conformity
application/pdf 399.16 KB
11/8/2023
399.16 KB
RAEGuard 2 PID Atex Certificate of Conformity
application/pdf 240.87 KB
11/8/2023
240.87 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
RAEGuard 2 PID Intrinsic Safety Report
application/pdf 50.9 KB
7/15/2021
50.9 KB
DigiPID EU Declaration of Conformity
application/pdf 213.06 KB
2/4/2022
213.06 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
RAEGuard 2 PID ATEX EC-Type Examiniation Certificate
application/pdf 964.3 KB
7/15/2021
964.3 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Name
Description
File Size
Date
Size
RAEGuard 2 PID User Guide Rev-R ENG
application/pdf 3.76 MB
7/7/2022
3.76 MB
RAEGuard 2 (FGM 2xxx) EU Declaration of Conformity
application/pdf 201.56 KB
1/6/2022
201.56 KB
EU & UK Declaration of Conformity RAEGuard 2
application/pdf 557.92 KB
7/25/2023
557.92 KB
RAEGuard 2 PID EU Declaration of Conformity
application/pdf 201.56 KB
2/4/2022
201.56 KB
RAEGuard 2 PID DigiPID ATEX CE EU Declaration of Conformity
application/pdf 399.16 KB
11/8/2023
399.16 KB
Technical Note 146 Turning On UV Lamps In A PID Monitor
application/pdf 787.55 KB
7/15/2021
787.55 KB
RAEGuard 2 PID Atex Certificate of Conformity
application/pdf 240.87 KB
11/8/2023
240.87 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Technical Note 161 Intrinsic Safety And Hazardous Locations
application/pdf 884.37 KB
7/15/2021
884.37 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 826.34 KB
7/15/2021
826.34 KB
Technical Note 163 Addressing PID Instruments Moisture Sensitivity
application/pdf 944.51 KB
7/15/2021
944.51 KB
RAEGuard 2 PID Data Sheet
application/pdf 406.17 KB
7/15/2021
406.17 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
RAEGuard 2 PID Intrinsic Safety Report
application/pdf 50.9 KB
7/15/2021
50.9 KB
DigiPID EU Declaration of Conformity
application/pdf 213.06 KB
2/4/2022
213.06 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
DigiPID ATEX EC-Type Examination Certificate
application/pdf 1.3 MB
7/15/2021
1.3 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
7/15/2021
820.7 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
RAEGuard 2 PID ATEX EC-Type Examiniation Certificate
application/pdf 964.3 KB
7/15/2021
964.3 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Showing 1 to 10 of 85 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
033-3003-100
PUMP ASSY, ASF3003, RAEGuard PID
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3003-100
PUMP ASSY, ASF3003, RAEGuard PID
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3032-000
Magnet Key, RAEGuard and RAEGuard 2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3034-000
ASSY,FILTER (D50MMX0.22UM)
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3034-000
ASSY,FILTER (D50MMX0.22UM)
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3035-000
DigiPID external dust pre-filter
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
033-3035-000
DigiPID external dust pre-filter
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
050-0000-005
DigiPID lamp, 10.6 ev, 12
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
050-0000-005
DigiPID lamp, 10.6 ev, 12
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
050-0061-001
LAMP,10.6EV,12,13X40,MARK2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
050-0061-001
LAMP,10.6EV,12,13X40,MARK2
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
081-0017-000
Kit, Lamp Cleaning (cleaning solution: Isopropanol)Note: The recommended cleaning fluid Isopropanol is not included.
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
081-0018-C00
KIT,AIR DRYING PRE-FILTER,CHINA
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
081-0018-C00
KIT,AIR DRYING PRE-FILTER,CHINA
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
411-0024-026
TUBING,TYGON,332X732X116
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
411-0024-026
TUBING,TYGON,332X732X116
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
430-0009-025
SCREW PKG 25,MACHINE,256X316,(PCB MOUNT
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
430-0009-025
SCREW PKG 25,MACHINE,256X316,(PCB MOUNT
https://s7d1.scene7.com/is/image/Honeywell65/RAEGuard-2-PID_Full-front-view_clr-bkg
Feedback