Based on the foundation of the highly successful and reliable SS4 Flame Detector, the FS20X Flame Detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X is a Multi-Spectrum and UV/Dual IR/VIS Flame Detector with a proven UV solar-blind sensor. The FS20X exhibits faster false-alarm free response to fires over a wider temperature range and with a much longer detection range compared to conventional UV/IR detectors.
Conventional and older technology UV/IR detectors, using narrow band 4.3 micron IR sensors, will not respond to smoky fires or if the detector lens is contaminated with oil and other substances since both UV and 4.3 micron signals are attenuated, obscured or absorbed by thick smoke or detector lens contaminants. Also, these old technology UV/IR detectors will not alarm to any fire if they are installed behind ordinary window glass.
Dual microprocessors provide a high level of fail-safe operation combined with fast and reliable performance. The Master Microprocessor performs high-speed digital sampling and signal processing calculations: while the slave microprocessor handles various sensor data, performs communications, self-diagnostics and provides interface versatility: and additional memory for storing Event Log and FirePic™ data.
The FS20X Flame Detector has a detection range in excess of 200 feet (very high sensitivity setting) for the detection of a one square-foot Heptane reference fire and has a cone of vision greater in volumetric coverage than most UV/IR detectors. This means fewer detectors can be used as compared to other manufacturers’ detectors.
Additional Features and Benefits:
- Patented* WideBand IR™ Infrared combined with Ultraviolet
- Detection range greater than 200 feet to 1 sq. ft. heptane fire
- Patented* Electronic Frequency Analysis
- Visible Sensor for optimum false alarm rejection
- Selectable detection sensitivities
- Solar blind 90° full 100% cone-of-vision
- Dual Microprocessors for reliable performance
- Real-time clock for accurate time dating of events
- FirePic™ — Up to 6 pre-fire event data storage
- Event log — Up to 200 events with date and time stamp
- Built-in RS-485 ModBus Communication
- Built-in non-isolated 4-20 mA analog output (sink or source)
- Alarm, Fault and Fire Verification relays.
- Automatic Optical Path and Electronic Self-Test
- Widest operating temperature range
- Patented* Electronics Module for components protection with plug-in terminations for easy field installation
- Two ¾” NPT OR 25mm conduit entries
- Low power consumption
- High RFI and EMI immunity
- FM approved
- Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
- Arc welding immunity
- False alarm rejection for all environmental conditions
- Minimal maintenance for trouble-free operation
- PC software and Interface Module (FSIM) for fault diagnostics real-time graphs (RTGs), and downloading of FirePics™ and event log
- Suitable for a wide variety of applications.
- Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
- Range greater than 200 feet to 1 sq. ft. heptane fire
- Arc welding immunity
- Field of view: 90° full 100% core of vision, ± 45° from on axis
- Operating voltage: 24 VDC nominal (18-32 VDC) - regulated
- Sensitivity: Very high, high, medium and low - switch selectable
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Overview
- Brand
- Honeywell
- Honeywell
- Notifier
- Warranty
- 3 Years from Date of Shipment
Features
- Sub-Category
- Flame Detectors
- Flame Detectors
- Alarm Included
- Yes
- Features
- Arc Welding Immunity
- Relay Included
- Yes
- Warnings & Restrictions
- Do Not Use Silicone-Based or Commercial Window Cleaning Products
- These will Degrade the Model FS20X Detector Performance
- Warning: Potential Electrostitic Charge and Wipe Enclosure Only with a Damp Cloth
- Wireless Technology
- WideBand IR™
- Visual Indicators
- Green LED: Power
- Red LED: Alarm
- Yellow: Fault
- Vibration
- Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
Dimensions & Weight
- Mounting Hole Diameter
- 0.25
Technical Specifications
- Output Signal Range
- 4 to 20 mA
- Humidity Range
- 5 to 98% RH (Non-Condensing)
- Altitude Range
- 200ft (60m)
- Analog Output Signal Type
- mA
- Number of Digital Communication Ports
- 2
- Relay Rated Load
- 1A @24V DC
- Relay Output Configuration
- Auxiliary: SPDT (NO/NC)
- Fault: SPST (NO)
- Fire Alarm: SPDT (NO/NC)
- Relay Activation Settings
- Relay 1: Fire Alarm
- Relay 2: Fault
- Relay 3: Auxilary
- Sensing Method
- IR, UV
- Maximum Analog Input Resistance
- 400
- Plug Type
- 10 pin for J2 Connector
- 6 pin for J1 Connector
- Output Signal Type
- mA
- Number of Relay Outputs
- 3
- Mounting
- Swivel Bracket Assembly
- Default Relay Activation
- Alarm Relay (Relay 1), Auxiliary Relay V (Relay 2), Fault Relay (Relay 3)
- Wiring
- Shielded: 2.5 sq.mm (14 AWG) to 0.326 sq.mm (22 AWG)
- Spectral Sensitivity
- Near Band IR: 0.7 to 1.1 microns
- Ultraviolet: 185 to 260 Nanometers
- Visible: 400 to 700 Nanometers
- Wide Band IR: 1.1 to 3.5 Microns
- Sensitivity
- Very High, High, Medium, Low
- Loop Resistance
- 50 to 400 Ohms
- 50 to 400 Ohms
- Field of View
- 90° Full 100% Core of Vision
- ± 45° From On Axis
- Conduit Entries
- (2) 3/4 in NPT
- Communication
- FireBus II
- ModBus Protocol
- RS485
Operating Characteristics
- Minimum Temperature
- -40˚C
- Storage Temperature
- -55 to +110°C
- -55 to 100°C
Standards & Certifications
- Certifications - Regional
- Global
- NEMA Rating
- NEMA 4, 4X
- Ingress Protection
- IP66
Electrical Specifications
- Operating Current
- 85
- Maximum Operating Current
- 83 mA
- Operating Voltage
- 24 VDC
Material Specifications
- Enclosure Material
- 316 Stainless Steel
- Copper-Free Powder Coated Aluminum
- Copper-Free Powder Coated Aluminum or 316 Stainless Steel
Applications & Compatibility
- Application
- Acetylene Processing and Storage
- Aircraft Hangars
- Chemical Production, Storage and Loading Facilities
- Crude Oil and Gasoline Storage and Tank Farms
- Ethanol, Methanol and IPA Production and Storage
- Hydrogen Plants and Storage
- LNG/LPG Loading and Unloading Facilities
- Natural Gas and CNG Plants
- Off-Shore Platforms
- Oil and Gas Pipelines and Pumping Stations
- Paint and Solvent Storage
- Refineries and Oil Production Facilities
- Turbine/Compressor Enclosures
Overview
- Brand
- Honeywell
- Honeywell
- Notifier
- Warranty
- 3 Years from Date of Shipment
Features
- Sub-Category
- Flame Detectors
- Flame Detectors
- Alarm Included
- Yes
- Features
- Arc Welding Immunity
- Relay Included
- Yes
- Warnings & Restrictions
- Do Not Use Silicone-Based or Commercial Window Cleaning Products
- These will Degrade the Model FS20X Detector Performance
- Warning: Potential Electrostitic Charge and Wipe Enclosure Only with a Damp Cloth
- Wireless Technology
- WideBand IR™
- Visual Indicators
- Green LED: Power
- Red LED: Alarm
- Yellow: Fault
- Vibration
- Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
Dimensions & Weight
- Mounting Hole Diameter
- 0.25
Technical Specifications
- Output Signal Range
- 4 to 20 mA
- Humidity Range
- 5 to 98% RH (Non-Condensing)
- Altitude Range
- 200ft (60m)
- Analog Output Signal Type
- mA
- Number of Digital Communication Ports
- 2
- Relay Rated Load
- 1A @24V DC
- Relay Output Configuration
- Auxiliary: SPDT (NO/NC)
- Fault: SPST (NO)
- Fire Alarm: SPDT (NO/NC)
- Relay Activation Settings
- Relay 1: Fire Alarm
- Relay 2: Fault
- Relay 3: Auxilary
- Sensing Method
- IR, UV
- Maximum Analog Input Resistance
- 400
- Plug Type
- 10 pin for J2 Connector
- 6 pin for J1 Connector
- Output Signal Type
- mA
- Number of Relay Outputs
- 3
- Mounting
- Swivel Bracket Assembly
- Default Relay Activation
- Alarm Relay (Relay 1), Auxiliary Relay V (Relay 2), Fault Relay (Relay 3)
- Wiring
- Shielded: 2.5 sq.mm (14 AWG) to 0.326 sq.mm (22 AWG)
- Spectral Sensitivity
- Near Band IR: 0.7 to 1.1 microns
- Ultraviolet: 185 to 260 Nanometers
- Visible: 400 to 700 Nanometers
- Wide Band IR: 1.1 to 3.5 Microns
- Sensitivity
- Very High, High, Medium, Low
- Loop Resistance
- 50 to 400 Ohms
- 50 to 400 Ohms
- Field of View
- 90° Full 100% Core of Vision
- ± 45° From On Axis
- Conduit Entries
- (2) 3/4 in NPT
- Communication
- FireBus II
- ModBus Protocol
- RS485
Operating Characteristics
- Minimum Temperature
- -40˚C
- Storage Temperature
- -55 to +110°C
- -55 to 100°C
Standards & Certifications
- Certifications - Regional
- Global
- NEMA Rating
- NEMA 4, 4X
- Ingress Protection
- IP66
Electrical Specifications
- Operating Current
- 85
- Maximum Operating Current
- 83 mA
- Operating Voltage
- 24 VDC
Material Specifications
- Enclosure Material
- 316 Stainless Steel
- Copper-Free Powder Coated Aluminum
- Copper-Free Powder Coated Aluminum or 316 Stainless Steel
Applications & Compatibility
- Application
- Acetylene Processing and Storage
- Aircraft Hangars
- Chemical Production, Storage and Loading Facilities
- Crude Oil and Gasoline Storage and Tank Farms
- Ethanol, Methanol and IPA Production and Storage
- Hydrogen Plants and Storage
- LNG/LPG Loading and Unloading Facilities
- Natural Gas and CNG Plants
- Off-Shore Platforms
- Oil and Gas Pipelines and Pumping Stations
- Paint and Solvent Storage
- Refineries and Oil Production Facilities
- Turbine/Compressor Enclosures
- Brand : Honeywell|Honeywell|Notifier
- Sub-Category : Flame Detectors|Flame Detectors
- Mounting Hole Diameter : 0.25
- Output Signal Range : 4 to 20 mA
- Humidity Range : 5 to 98% RH (Non-Condensing)
- Altitude Range : 200ft (60m)
- Minimum Temperature : -40˚C
- Alarm Included : Yes
- Analog Output Signal Type : mA
- Certifications - Regional : Global
- Features : Arc Welding Immunity
- Number of Digital Communication Ports : 2
- Relay Rated Load : 1A @24V DC
- Relay Output Configuration : Auxiliary: SPDT (NO/NC)|Fault: SPST (NO)|Fire Alarm: SPDT (NO/NC)
- Relay Included : Yes
- Relay Activation Settings : Relay 1: Fire Alarm|Relay 2: Fault|Relay 3: Auxilary
- Sensing Method : IR, UV
- Operating Current : 85
- Maximum Operating Current : 83 mA
- Maximum Analog Input Resistance : 400
- Warnings & Restrictions : Do Not Use Silicone-Based or Commercial Window Cleaning Products|These will Degrade the Model FS20X Detector Performance|Warning: Potential Electrostitic Charge and Wipe Enclosure Only with a Damp Cloth
- Wireless Technology : WideBand IR™
- Visual Indicators : Green LED: Power|Red LED: Alarm|Yellow: Fault
- Plug Type : 10 pin for J2 Connector|6 pin for J1 Connector
- Output Signal Type : mA
- Number of Relay Outputs : 3
- NEMA Rating : NEMA 4, 4X
- Mounting : Swivel Bracket Assembly
- Ingress Protection : IP66
- Default Relay Activation : Alarm Relay (Relay 1), Auxiliary Relay V (Relay 2), Fault Relay (Relay 3)
- Wiring : Shielded: 2.5 sq.mm (14 AWG) to 0.326 sq.mm (22 AWG)
- Warranty : 3 Years from Date of Shipment
- Vibration : Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
- Storage Temperature : -55 to +110°C|-55 to 100°C
- Spectral Sensitivity : Near Band IR: 0.7 to 1.1 microns|Ultraviolet: 185 to 260 Nanometers|Visible: 400 to 700 Nanometers|Wide Band IR: 1.1 to 3.5 Microns
- Sensitivity : Very High, High, Medium, Low
- Operating Voltage : 24 VDC
- Loop Resistance : 50 to 400 Ohms|50 to 400 Ohms
- Field of View : 90° Full 100% Core of Vision|± 45° From On Axis
- Enclosure Material : 316 Stainless Steel|Copper-Free Powder Coated Aluminum|Copper-Free Powder Coated Aluminum or 316 Stainless Steel
- Conduit Entries : (2) 3/4 in NPT
- Communication : FireBus II|ModBus Protocol|RS485
- Application : Acetylene Processing and Storage|Aircraft Hangars|Chemical Production, Storage and Loading Facilities|Crude Oil and Gasoline Storage and Tank Farms|Ethanol, Methanol and IPA Production and Storage|Hydrogen Plants and Storage|LNG/LPG Loading and Unloading Facilities|Natural Gas and CNG Plants|Off-Shore Platforms|Oil and Gas Pipelines and Pumping Stations|Paint and Solvent Storage|Refineries and Oil Production Facilities|Turbine/Compressor Enclosures
Data Sheet
Manuals and Guides
Firmware
Technical Note
Certificate
Others
Please sign in to view part numbers available for purchase based on your account Sign In
Please sign in to view part numbers available for purchase based on your account Sign In