Products
Products
News and Events
Part Numbers
General Content
/content/sps/us/en/search-results.html

Multi-Gas Detection

MultiRAE Pro

Wireless, portable multi-threat monitor for radiation and chemical detection

Overview
his-rae-multirae-pro-front-hires

This industry-leading wireless device monitors both chemical threats and gamma radiation and is the only multi-threat monitor with parts per billion precision. With the ability to wirelessly transmit threat and alarm data in real time to a central command station, the MultiRAE Pro offers improved visibility and awareness. It also gives you the flexibility to swap out 25 different sensors for a range of threats, including VOCs, toxic gases, combustibles, oxygen levels, as well as gamma radiation detection. The large display and replaceable sensors, pump, and battery make it easy to use and maintain, while five different alarms, including man down, provide the versatility you need to respond appropriately and quickly to incidents.

Features and Benefits:

  • Parts per billion VOC measurement
  • Industry-leading wireless multi-threat device
  • Simultaneous monitoring of chemical threats and gamma radiation
  • Real-time data access from central command
  • More than 25 different chemical sensors
  • Swappable sensors
  • Man down alarm
  • Simple maintenance with replaceable sensors, pump, and battery
  • Fully automatic bump testing and calibration with AutoRAE 2
  • 5-way local and remote wireless alarm
  • Mil-STD-810G certified
  • Device Management with Honeywell Sotera™ Express
  • Readily enables to communicate with Motorola MOTOTRBO

Application:

  • CBRNE
  • Hazmat Response
  • Indoor Air Quality
  • Urban Search & Rescue
  • Venue Protection
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 31 ounce av
    • 880 gram
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Weight range
    • 880 g gram

Category

  • Sub-Category
    • Multi-Threat Monitor
    • Premium-Gas

Range

  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent
  • Sensor Range
    • GAMMA 0 to 20,000 μRem/h, Carbon Dioxide (CO2) 0 to 50,000 ppm, Ammonia (NH3) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Carbon Monoxide (CO), EXT. RANGE 0 to 2,000 ppm, Carbon Monoxide (CO), H2-COMP. 0 to 2,000 ppm, Carbon Monoxide (CO) + 0 to 500 ppm, Hydrogen Sulfide (H2S) COMBO 0 to 200 ppm, Chlorine (CL2) 0 to 50 ppm, Chlorine Dioxide (CLO2) 0 to 1 ppm, Ethylene Oxide (ETO-A) 0 to 100 ppm, Ethylene Oxide (ETO-B) 0 to 10 ppm, Formaldehyde (HCHO) 0 to 10 ppm, Hydrogen Cynaide (HCN) 0 to 50 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Methyl Mercaptan (CH3-SH) 0 to 10 ppm, Nitric Oxide (NO) 0 to 250 ppm, Nitrogen Dioxide (NO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol., Oxygen (LIQ O2) 0 to 30% Vol., Phosphine (PH3) 0 to 20 ppm, Phosphine (PH3 H) 0 to 20 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Features

  • Alarm Included
    • Yes
  • Series Name
    • MultiRAE Pro
  • Languages
    • Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish

Alarm

  • Alarm Type
    • Audible (95 dB @30 cm)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)

Battery & Charging

  • Batteries Required
    • Yes
  • Batteries Included
    • Yes
  • Battery Run Time
    • 12-18 hours
    • AA Batteries (6 Hours) hours
    • Extended Duration Li-Ion (18 Hours) hours
    • Rechargeable Li-Ion (12 Hours) hours
  • Charging Time
    • 6 hours
    • 9 hours

Calibration

  • Calibration Procedures
    • AutoRAE 2 Test
    • Bump Test
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual

Certifications

  • Certifications - Performance
    • ISA-12.13.01
    • LEL CSA C22.2 No. 152
    • Performance Tests: MIL-STD-810G and 461F
  • Standards
    • ATEX: 0575 II 1G Ex ia IIC T4 Ga
    • ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed
    • ATEX: I M1 Ex ia I Ma
    • CSA: Class I, Div 1, Group A, B, C, D, T4
    • CSA: Class II, Div 1, Group E, F, G T85°C
    • IECEx/ANZEx: Ex ia I Ma
    • IECEx/ANZEx: Ex ia IIC T4 Ga
    • IECEx/ANZEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: Ex ia IIC T4 Ga
    • IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: I M1 Ex ia I Ma

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Display

  • Display Included
    • Yes
  • Display Readout
    • Battery Status, Datalogging On/Off
    • Man Down Alarm On/Off
    • PID Measurement Gas and Correction Factor
    • Real-Time Reading of Gas Concentrations
    • Visual Compliance Indicator
    • Wireless On/Off and Reception Quality, STEL, TWA, Peak, and Minimum Values
  • Display Matrix
    • 128 x 160
  • Display Type
    • Monochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature

Features & Benefits

  • Features & Benefits
    • All-in-One Monitoring Capabilities for Radiation, VOCs, Oxygen, Toxic and Combustible Gases, up to 6 Threat Types at a Time
    • Device Management with Honeywell SafetySuite
    • Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field
    • Large Graphical Display with Easy-to-Use, Icon-Driven User Interface
    • Over 25 Interchangeable Sensor Options, Including Parts-per-Billion PID and Gamma Radiation
    • Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • User-Configurable Datalogging Intervals

Sampling

  • Sampling Pump Included
    • Yes
  • Sampling Pump Range
    • 100ft (30m) meter
  • Sampling Pump Rate
    • 250

Sensor

  • Number of Sensors Included
    • 25
  • Sensor Type
    • Radiation, PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR

Warranty

  • Warranty
    • 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components and Catalytic LEL Sensors
    • 3 Years on CO and H2S Sensors
    • 4 Years on Liq O2 Sensors

Wireless

  • Wireless Technology
    • MESH, Wifi, BLE
  • Wireless Enabled
    • Yes

Additional Specifications

  • External Calibration
    • AutoRAE 2 Test and Calibration System
  • Replacement Parts
    • 25 Intelligent Interchangeable Field-Replaceable Sensors
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Decibels
    • 95 decibel

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Dimensions & Weight

  • Size
    • H: 7.6 in W: 3.8 in D: 2.6 in

Technical Specifications

  • Communication and Data Download
    • Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System
    • Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)
  • Operating Frequency Range
    • ISM License Free Band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
  • Dust and Water Resistance
    • IP65
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Wireless Network
    • EchoView Host-Based Closed-Loop System
    • ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Range
    • MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)
    • MultiRAE to RAELink3 [Z1] Mesh modem 330 ft (100m)
    • MultiRAE to Wi-Fi Access Point 330 ft (100m)
  • Radio Module
    • Supports RM900A
  • Model Number
    • MultiRAE
    • PGM-6228
  • Keypad Type
    • 3 Operation and Programming Keys (Mode, Y/+, and N/-)
  • Sampling
    • Built-In Pump. Auto Shutoff in Low-Flow Conditions
  • EMC/RFI
    • EMC Directive: 2004/108/EC
  • Tests
    • Automatic Bump Test

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Civil Defense (Search and Rescue)
    • Environmental
    • HazMat Response
    • Homeland Security
    • Military
    • Semiconductor Manufacturing

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 31 ounce av
    • 880 gram
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Weight range
    • 880 g gram

Category

  • Sub-Category
    • Multi-Threat Monitor
    • Premium-Gas

Range

  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent
  • Sensor Range
    • GAMMA 0 to 20,000 μRem/h, Carbon Dioxide (CO2) 0 to 50,000 ppm, Ammonia (NH3) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Carbon Monoxide (CO), EXT. RANGE 0 to 2,000 ppm, Carbon Monoxide (CO), H2-COMP. 0 to 2,000 ppm, Carbon Monoxide (CO) + 0 to 500 ppm, Hydrogen Sulfide (H2S) COMBO 0 to 200 ppm, Chlorine (CL2) 0 to 50 ppm, Chlorine Dioxide (CLO2) 0 to 1 ppm, Ethylene Oxide (ETO-A) 0 to 100 ppm, Ethylene Oxide (ETO-B) 0 to 10 ppm, Formaldehyde (HCHO) 0 to 10 ppm, Hydrogen Cynaide (HCN) 0 to 50 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Methyl Mercaptan (CH3-SH) 0 to 10 ppm, Nitric Oxide (NO) 0 to 250 ppm, Nitrogen Dioxide (NO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol., Oxygen (LIQ O2) 0 to 30% Vol., Phosphine (PH3) 0 to 20 ppm, Phosphine (PH3 H) 0 to 20 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Features

  • Alarm Included
    • Yes
  • Series Name
    • MultiRAE Pro
  • Languages
    • Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish

Alarm

  • Alarm Type
    • Audible (95 dB @30 cm)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)

Battery & Charging

  • Batteries Required
    • Yes
  • Batteries Included
    • Yes
  • Battery Run Time
    • 12-18 hours
    • AA Batteries (6 Hours) hours
    • Extended Duration Li-Ion (18 Hours) hours
    • Rechargeable Li-Ion (12 Hours) hours
  • Charging Time
    • 6 hours
    • 9 hours

Calibration

  • Calibration Procedures
    • AutoRAE 2 Test
    • Bump Test
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual

Certifications

  • Certifications - Performance
    • ISA-12.13.01
    • LEL CSA C22.2 No. 152
    • Performance Tests: MIL-STD-810G and 461F
  • Standards
    • ATEX: 0575 II 1G Ex ia IIC T4 Ga
    • ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed
    • ATEX: I M1 Ex ia I Ma
    • CSA: Class I, Div 1, Group A, B, C, D, T4
    • CSA: Class II, Div 1, Group E, F, G T85°C
    • IECEx/ANZEx: Ex ia I Ma
    • IECEx/ANZEx: Ex ia IIC T4 Ga
    • IECEx/ANZEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: Ex ia IIC T4 Ga
    • IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: I M1 Ex ia I Ma

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Display

  • Display Included
    • Yes
  • Display Readout
    • Battery Status, Datalogging On/Off
    • Man Down Alarm On/Off
    • PID Measurement Gas and Correction Factor
    • Real-Time Reading of Gas Concentrations
    • Visual Compliance Indicator
    • Wireless On/Off and Reception Quality, STEL, TWA, Peak, and Minimum Values
  • Display Matrix
    • 128 x 160
  • Display Type
    • Monochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature

Features & Benefits

  • Features & Benefits
    • All-in-One Monitoring Capabilities for Radiation, VOCs, Oxygen, Toxic and Combustible Gases, up to 6 Threat Types at a Time
    • Device Management with Honeywell SafetySuite
    • Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field
    • Large Graphical Display with Easy-to-Use, Icon-Driven User Interface
    • Over 25 Interchangeable Sensor Options, Including Parts-per-Billion PID and Gamma Radiation
    • Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • User-Configurable Datalogging Intervals

Sampling

  • Sampling Pump Included
    • Yes
  • Sampling Pump Range
    • 100ft (30m) meter
  • Sampling Pump Rate
    • 250

Sensor

  • Number of Sensors Included
    • 25
  • Sensor Type
    • Radiation, PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR

Warranty

  • Warranty
    • 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components and Catalytic LEL Sensors
    • 3 Years on CO and H2S Sensors
    • 4 Years on Liq O2 Sensors

Wireless

  • Wireless Technology
    • MESH, Wifi, BLE
  • Wireless Enabled
    • Yes

Additional Specifications

  • External Calibration
    • AutoRAE 2 Test and Calibration System
  • Replacement Parts
    • 25 Intelligent Interchangeable Field-Replaceable Sensors
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Decibels
    • 95 decibel

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Dimensions & Weight

  • Size
    • H: 7.6 in W: 3.8 in D: 2.6 in

Technical Specifications

  • Communication and Data Download
    • Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System
    • Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)
  • Operating Frequency Range
    • ISM License Free Band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
  • Dust and Water Resistance
    • IP65
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Wireless Network
    • EchoView Host-Based Closed-Loop System
    • ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Range
    • MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)
    • MultiRAE to RAELink3 [Z1] Mesh modem 330 ft (100m)
    • MultiRAE to Wi-Fi Access Point 330 ft (100m)
  • Radio Module
    • Supports RM900A
  • Model Number
    • MultiRAE
    • PGM-6228
  • Keypad Type
    • 3 Operation and Programming Keys (Mode, Y/+, and N/-)
  • Sampling
    • Built-In Pump. Auto Shutoff in Low-Flow Conditions
  • EMC/RFI
    • EMC Directive: 2004/108/EC
  • Tests
    • Automatic Bump Test

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Civil Defense (Search and Rescue)
    • Environmental
    • HazMat Response
    • Homeland Security
    • Military
    • Semiconductor Manufacturing
  • Brand : Honeywell RAE Systems|RAE
  • Weight : 31 ounce av|880 gram
  • Sub-Category : Multi-Threat Monitor|Premium-Gas
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Weight range : 880 g gram
  • Humidity Range : 0 to 95% RH (Non-Condensing) percent|0%-95% percent
  • Sensor Range : GAMMA 0 to 20,000 μRem/h, Carbon Dioxide (CO2) 0 to 50,000 ppm, Ammonia (NH3) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Carbon Monoxide (CO), EXT. RANGE 0 to 2,000 ppm, Carbon Monoxide (CO), H2-COMP. 0 to 2,000 ppm, Carbon Monoxide (CO) + 0 to 500 ppm, Hydrogen Sulfide (H2S) COMBO 0 to 200 ppm, Chlorine (CL2) 0 to 50 ppm, Chlorine Dioxide (CLO2) 0 to 1 ppm, Ethylene Oxide (ETO-A) 0 to 100 ppm, Ethylene Oxide (ETO-B) 0 to 10 ppm, Formaldehyde (HCHO) 0 to 10 ppm, Hydrogen Cynaide (HCN) 0 to 50 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Methyl Mercaptan (CH3-SH) 0 to 10 ppm, Nitric Oxide (NO) 0 to 250 ppm, Nitrogen Dioxide (NO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol., Oxygen (LIQ O2) 0 to 30% Vol., Phosphine (PH3) 0 to 20 ppm, Phosphine (PH3 H) 0 to 20 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm|NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature : -20|-20 degree Celsius|-4 degree Fahrenheit
  • Maximum Temperature : 122 degree Fahrenheit|50|50 degree Celsius
  • Alarm Included : Yes
  • Alarm Type : Audible (95 dB @30 cm)|Vibrating|Visual (Flashing Bright Red LEDs)
  • Batteries Required : Yes
  • Batteries Included : Yes
  • Battery Run Time : 12-18 hours|AA Batteries (6 Hours) hours|Extended Duration Li-Ion (18 Hours) hours|Rechargeable Li-Ion (12 Hours) hours
  • Charging Time : 6 hours|9 hours
  • Calibration Procedures : AutoRAE 2 Test|Bump Test
  • Calibration : Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Certifications - Performance : ISA-12.13.01|LEL CSA C22.2 No. 152|Performance Tests: MIL-STD-810G and 461F
  • Standards : ATEX: 0575 II 1G Ex ia IIC T4 Ga|ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed|ATEX: I M1 Ex ia I Ma|CSA: Class I, Div 1, Group A, B, C, D, T4|CSA: Class II, Div 1, Group E, F, G T85°C|IECEx/ANZEx: Ex ia I Ma|IECEx/ANZEx: Ex ia IIC T4 Ga|IECEx/ANZEx: Ex ia d IIC T4 Gb with IR Sensor Installed|IECEx: Ex ia IIC T4 Ga|IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed|IECEx: I M1 Ex ia I Ma
  • Datalogging Interval : 1 min
  • Datalogging Capable : Yes
  • Datalogging : Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)|User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
  • Display Included : Yes
  • Display Readout : Battery Status, Datalogging On/Off|Man Down Alarm On/Off|PID Measurement Gas and Correction Factor|Real-Time Reading of Gas Concentrations|Visual Compliance Indicator|Wireless On/Off and Reception Quality, STEL, TWA, Peak, and Minimum Values
  • Display Matrix : 128 x 160
  • Display Type : Monochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature
  • Features & Benefits : All-in-One Monitoring Capabilities for Radiation, VOCs, Oxygen, Toxic and Combustible Gases, up to 6 Threat Types at a Time|Device Management with Honeywell SafetySuite|Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field|Large Graphical Display with Easy-to-Use, Icon-Driven User Interface|Over 25 Interchangeable Sensor Options, Including Parts-per-Billion PID and Gamma Radiation|Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions|Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected|User-Configurable Datalogging Intervals
  • Sampling Pump Included : Yes
  • Sampling Pump Range : 100ft (30m) meter
  • Sampling Pump Rate : 250
  • Number of Sensors Included : 25
  • Sensor Type : Radiation, PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR
  • Warranty : 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts|2 Years on Non-Consumable Components and Catalytic LEL Sensors|3 Years on CO and H2S Sensors|4 Years on Liq O2 Sensors
  • Wireless Technology : MESH, Wifi, BLE
  • Wireless Enabled : Yes
  • External Calibration : AutoRAE 2 Test and Calibration System
  • Ingress Protection : IP65|IP65
  • Replacement Parts : 25 Intelligent Interchangeable Field-Replaceable Sensors
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Decibels : 95 decibel
  • Size : H: 7.6 in W: 3.8 in D: 2.6 in
  • Communication and Data Download : Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System|Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)
  • Operating Frequency Range : ISM License Free Band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
  • Dust and Water Resistance : IP65
  • Wireless Approvals : CE RandTTE|FCC Part 15
  • Wireless Network : EchoView Host-Based Closed-Loop System|ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Range : MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)|MultiRAE to RAELink3 [Z1] Mesh modem 330 ft (100m)|MultiRAE to Wi-Fi Access Point 330 ft (100m)
  • Radio Module : Supports RM900A
  • Power Source : Battery
  • Model Number : MultiRAE|PGM-6228
  • Series Name : MultiRAE Pro
  • Keypad Type : 3 Operation and Programming Keys (Mode, Y/+, and N/-)
  • Application : Civil Defense (Search and Rescue)|Environmental|HazMat Response|Homeland Security|Military|Semiconductor Manufacturing
  • Languages : Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
  • Sampling : Built-In Pump. Auto Shutoff in Low-Flow Conditions
  • EMC/RFI : EMC Directive: 2004/108/EC
  • Tests : Automatic Bump Test
Data Sheet
Name
Description
File Size
Date
Size
MultiRAE Pro Data Sheet
application/pdf 127.65 KB
7/15/2021
127.65 KB
VOC Zeroing Tube Data Sheet
application/pdf 77.52 KB
5/7/2025
77.52 KB
Manuals and Guides
Name
Description
File Size
Date
Size
MultiRAE User Manual - UK
application/pdf 13.84 MB
5/10/2024
13.84 MB
MultiRAE User Manual - FR
application/pdf 13.77 MB
5/7/2024
13.77 MB
MultiRAE User Manual - ES
application/pdf 13.74 MB
5/7/2024
13.74 MB
MultiRAE User Manual - DE
application/pdf 13.71 MB
5/7/2024
13.71 MB
MultiRAE User Manual - IT
application/pdf 13.73 MB
5/8/2024
13.73 MB
MultiRAE User Manual - KO
application/pdf 14.01 MB
5/8/2024
14.01 MB
MultiRAE (Pumped Models) User's Guide - EN
application/pdf 898.78 KB
11/15/2023
898.78 KB
MultiRAE (Diffusion) Quick Reference Guide
application/pdf 595.58 KB
12/13/2023
595.58 KB
MultiRAE User Manual - JP
application/pdf 14.13 MB
5/8/2024
14.13 MB
MultiRAE User Guide
application/pdf 8.12 MB
7/15/2021
8.12 MB
Software
Name
Description
File Size
Date
Size
MultiRAE Sensor Firmware V 1.56.006 with signature
application/zip 264.62 KB
1/4/2024
264.62 KB
MultiRAE Application Firmware V 1.56.006 with signature
application/zip 1.4 MB
1/4/2024
1.4 MB
Brochure
Name
Description
File Size
Date
Size
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
10/28/2024
441.3 KB
Technical Note
Name
Description
File Size
Date
Size
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Lithium-Ion Batteries Technical Note 166
application/pdf 926.7 KB
7/15/2021
926.7 KB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
7/15/2021
620.4 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
application/pdf 1.1 MB
7/15/2021
1.1 MB
Technical Note 176 Basics Of Nuclear Radiation
application/pdf 1.31 MB
7/15/2021
1.31 MB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
application/pdf 790.79 KB
7/15/2021
790.79 KB
Technical Note 170 USB To Serial Port Adapter
application/pdf 1.26 MB
7/15/2021
1.26 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
Technical Note 141 Monitor Remote Control Functions
application/pdf 984.3 KB
8/3/2022
984.3 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Certificate
Name
Description
File Size
Date
Size
MultiRAE - EU Declaration of Conformity
application/pdf 212.27 KB
1/7/2022
212.27 KB
Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
application/pdf 817.01 KB
7/15/2021
817.01 KB
MultiRAE - CSA Certificate of Compliance
application/pdf 136.44 KB
1/7/2022
136.44 KB
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
MultiRAE - Atex SIra EU Type Exam Certification
application/pdf 310.08 KB
1/7/2022
310.08 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
application/pdf 226.06 KB
7/15/2021
226.06 KB
Application Note 214: Environmental Applications For PIDs
application/pdf 836.36 KB
7/15/2021
836.36 KB
Others
Name
Description
File Size
Date
Size
MultiRAE Family IECEx Certificate of Conformity
application/pdf 322.45 KB
7/15/2021
322.45 KB
Name
Description
File Size
Date
Size
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
MultiRAE - EU Declaration of Conformity
application/pdf 212.27 KB
1/7/2022
212.27 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
application/pdf 817.01 KB
7/15/2021
817.01 KB
MultiRAE User Manual - UK
application/pdf 13.84 MB
5/10/2024
13.84 MB
MultiRAE Pro Data Sheet
application/pdf 127.65 KB
7/15/2021
127.65 KB
MultiRAE User Manual - FR
application/pdf 13.77 MB
5/7/2024
13.77 MB
MultiRAE User Manual - ES
application/pdf 13.74 MB
5/7/2024
13.74 MB
MultiRAE - CSA Certificate of Compliance
application/pdf 136.44 KB
1/7/2022
136.44 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
MultiRAE User Manual - DE
application/pdf 13.71 MB
5/7/2024
13.71 MB
Lithium-Ion Batteries Technical Note 166
application/pdf 926.7 KB
7/15/2021
926.7 KB
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
7/15/2021
620.4 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
VOC Zeroing Tube Data Sheet
application/pdf 77.52 KB
5/7/2025
77.52 KB
Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
MultiRAE User Manual - IT
application/pdf 13.73 MB
5/8/2024
13.73 MB
MultiRAE User Manual - KO
application/pdf 14.01 MB
5/8/2024
14.01 MB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
MultiRAE Sensor Firmware V 1.56.006 with signature
application/zip 264.62 KB
1/4/2024
264.62 KB
MultiRAE Application Firmware V 1.56.006 with signature
application/zip 1.4 MB
1/4/2024
1.4 MB
MultiRAE (Pumped Models) User's Guide - EN
application/pdf 898.78 KB
11/15/2023
898.78 KB
MultiRAE (Diffusion) Quick Reference Guide
application/pdf 595.58 KB
12/13/2023
595.58 KB
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
10/28/2024
441.3 KB
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
application/pdf 1.1 MB
7/15/2021
1.1 MB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
application/pdf 226.06 KB
7/15/2021
226.06 KB
MultiRAE Family IECEx Certificate of Conformity
application/pdf 322.45 KB
7/15/2021
322.45 KB
Technical Note 176 Basics Of Nuclear Radiation
application/pdf 1.31 MB
7/15/2021
1.31 MB
MultiRAE - Atex SIra EU Type Exam Certification
application/pdf 310.08 KB
1/7/2022
310.08 KB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
application/pdf 790.79 KB
7/15/2021
790.79 KB
Technical Note 170 USB To Serial Port Adapter
application/pdf 1.26 MB
7/15/2021
1.26 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
Technical Note 141 Monitor Remote Control Functions
application/pdf 984.3 KB
8/3/2022
984.3 KB
MultiRAE User Manual - JP
application/pdf 14.13 MB
5/8/2024
14.13 MB
Application Note 214: Environmental Applications For PIDs
application/pdf 836.36 KB
7/15/2021
836.36 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
MultiRAE User Guide
application/pdf 8.12 MB
7/15/2021
8.12 MB
Name
Date
Size
Showing 1 to 1 of 1 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
GVMCB3-A3C136E-DS2
MR PR,CSA,DRSKO,PID,LEL,SO2,CL2,O2,P2P
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-pro-front-hires
GVMCB3-A3C136E-DS2
MR PR,CSA,DRSKO,PID,LEL,SO2,CL2,O2,P2P
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-pro-front-hires
Feedback