Fixed Gas Detectors
Searchline Excel™ Edge
Open Path Infrared Gas Detector - Long Range
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.

- Fast response to flammable hydrocarbon gas even in low visibility
- Advanced diagnostics including window clarity and alignment accuracy to enable maximum uptime
- Honeywell’s Fixed Platform Universal Mount and new alignment scope makes for easy installation
- Bluetooth® connectivity for simplified, non-intrusive set-up and maintenance.
- High Visibility, Multi Color LED HALO ring provides clear indication of device status
- Detection from 60 to 330 meters (196 to 1082 feet)
- Multiple outputs including 4-20mA, Relays, HART®, Modbus and Bluetooth® communication
- Responses to a wide range of hydrocarbon gases such as Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, and Propylene
- Speed of response (T90) less than 3 seconds
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Overview
- Brand
- Honeywell
- Honeywell
Features
- Sub-Category
- Open Path Gas Detectors & Transmitters
- Open Path Gas Detectors and Transmitters
- Alarm Settings
- High 3 LEL.m
- Low 1 LEL.m
- Min 0.5 LEL.m
- Features & Benefits
- Advanced Alignment Scope
- Automatic Optimal Alignment Test
- Built-In Health Test and Logging
- Electro-Optical Compartment and Module
- Fast Response to Flammable Hydrocarbon Gas
- Full Logging and Auto-Reporting
- High-End Coaxial Measurement and Dual Reference with Complex Filtering and Advanced Algorithms
- Honeywell Fixed Platform Universal Mount
- Low Maintenance
- No Field Calibration Required
- Patented, High Dynamic Range, Transmission and Reception Technology
- Provides Long Distance Fence-Line (Perimeter) Monitoring
- Robust, Painted, Stainless Steel Housing
- Two Compartments (Ex de) with Separate Electro-Optical Module from Connections
- Features
- Bluetooth® enabled
- Wireless Technology
- Bluetooth (Range up to 20m)
- Bluetooth® (range up to 20 m (66 ft)
- Visual Indicators
- Blue: Bluetooth Pairing Mode
- Green: Normal
- Red: Alarm
- Yellow: Fault
- Repeatability
- ±0.4 LEL.m
Dimensions & Weight
- Weight range
- Rx: 6.1 kg (13.4 lbs)
- Tx: 6.0 kg (13.2 lb)
- Path Length
- 60 to 330 m
- Dimension
- 4.06 in dia x 12.8 in x 7.09 in
Technical Specifications
- Sensor Range
- 60 m to 330 m (196 to 1,082 ft)
- Humidity Range
- 0 to 99% RH (Non-Condensing)
- 0–99 % RH Non-condensing
- Analog Output Signal Type
- 4-20mA standard
- Relay Rated Load
- Max. 32 Vdc/ac, max. 2 A resistive load
- Relay Output Configuration
- Relay 1 is Alarm Level 1, Relay 2 is Alarm Level 2, Relay 3 Indicates Faults
- Relay Activation Settings
- Single Pole Double Throw (SPDT)
- Sensor Type
- Open Path Infrared
- Sensing Method
- Near Band Infrared
- Output Signal Type
- 4 to 20 mA with HART®
- Number of Relay Outputs
- 3
- Mounting
- Universal Mounting Bracket Included
- Universal Mounting Bracket Included
- Maximum Pressure
- 105.5 kPa
- 105.5 kPa (1055 mBar, non-compensated)
- Gas Type
- Flammable Hydrocarbon
- Flammable Hydrocarbon
- Warm Up Time
- Less than 1 Hour (Fully Stabilized)
- Less than 5 min (Operational)
- Speed of Response
- T90 < 3 sec
- Measuring Range
- 0-5 LEL.m
Operating Characteristics
- Minimum Temperature
- -55 °C (-67 °F)
- -55°C
- Storage Temperature
- -55 to +75°C
Electrical Specifications
- Analog Output Signal Current
- 4 to 20 mA
- Power Requirement
- 24 VDC
- Power Consumption
- Receiver: 3.0W (Above +30°C)
- Receiver: 4.8W (+30°C to -30°C)
- Receiver: 7.4W (Below -30°C)
- Transmitter: 11.8W (Below -30°C)
- Transmitter: 3.8W (Above +30°C)
- Transmitter: 5.6W (+30°C to -30°C)
Battery & Charging
- Battery Run Time
- 10 Years Lifetime
- Batteries Required
- TLH-2450
Standards & Certifications
- Standards
- EN 50270: (EMC)NEWLINEIEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EUNEWLINEIEC/EN/UL/CSA 61010 (Electrical Safety)NEWLINEFCC / ICNEWLINERoHS, China RoHS
- NEMA Rating
- Type 4X, in accordance with NEMA 250
- Ingress Protection
- IP66/67
- IP66/67
Material Specifications
- Material
- 316L Stainless Steel
- 316L Stainless Steel
Others
- Weight
- Receiver 6.1 kg (13.4 lbs), Transmitter 6.0 kg (13.2 lbs)
- Response Time
- T90 less than 3 seconds
- Maximum Temperature
- +75 °C (+167 °F)
Overview
- Brand
- Honeywell
- Honeywell
Features
- Sub-Category
- Open Path Gas Detectors & Transmitters
- Open Path Gas Detectors and Transmitters
- Alarm Settings
- High 3 LEL.m
- Low 1 LEL.m
- Min 0.5 LEL.m
- Features & Benefits
- Advanced Alignment Scope
- Automatic Optimal Alignment Test
- Built-In Health Test and Logging
- Electro-Optical Compartment and Module
- Fast Response to Flammable Hydrocarbon Gas
- Full Logging and Auto-Reporting
- High-End Coaxial Measurement and Dual Reference with Complex Filtering and Advanced Algorithms
- Honeywell Fixed Platform Universal Mount
- Low Maintenance
- No Field Calibration Required
- Patented, High Dynamic Range, Transmission and Reception Technology
- Provides Long Distance Fence-Line (Perimeter) Monitoring
- Robust, Painted, Stainless Steel Housing
- Two Compartments (Ex de) with Separate Electro-Optical Module from Connections
- Features
- Bluetooth® enabled
- Wireless Technology
- Bluetooth (Range up to 20m)
- Bluetooth® (range up to 20 m (66 ft)
- Visual Indicators
- Blue: Bluetooth Pairing Mode
- Green: Normal
- Red: Alarm
- Yellow: Fault
- Repeatability
- ±0.4 LEL.m
Dimensions & Weight
- Weight range
- Rx: 6.1 kg (13.4 lbs)
- Tx: 6.0 kg (13.2 lb)
- Path Length
- 60 to 330 m
- Dimension
- 4.06 in dia x 12.8 in x 7.09 in
Technical Specifications
- Sensor Range
- 60 m to 330 m (196 to 1,082 ft)
- Humidity Range
- 0 to 99% RH (Non-Condensing)
- 0–99 % RH Non-condensing
- Analog Output Signal Type
- 4-20mA standard
- Relay Rated Load
- Max. 32 Vdc/ac, max. 2 A resistive load
- Relay Output Configuration
- Relay 1 is Alarm Level 1, Relay 2 is Alarm Level 2, Relay 3 Indicates Faults
- Relay Activation Settings
- Single Pole Double Throw (SPDT)
- Sensor Type
- Open Path Infrared
- Sensing Method
- Near Band Infrared
- Output Signal Type
- 4 to 20 mA with HART®
- Number of Relay Outputs
- 3
- Mounting
- Universal Mounting Bracket Included
- Universal Mounting Bracket Included
- Maximum Pressure
- 105.5 kPa
- 105.5 kPa (1055 mBar, non-compensated)
- Gas Type
- Flammable Hydrocarbon
- Flammable Hydrocarbon
- Warm Up Time
- Less than 1 Hour (Fully Stabilized)
- Less than 5 min (Operational)
- Speed of Response
- T90 < 3 sec
- Measuring Range
- 0-5 LEL.m
Operating Characteristics
- Minimum Temperature
- -55 °C (-67 °F)
- -55°C
- Storage Temperature
- -55 to +75°C
Electrical Specifications
- Analog Output Signal Current
- 4 to 20 mA
- Power Requirement
- 24 VDC
- Power Consumption
- Receiver: 3.0W (Above +30°C)
- Receiver: 4.8W (+30°C to -30°C)
- Receiver: 7.4W (Below -30°C)
- Transmitter: 11.8W (Below -30°C)
- Transmitter: 3.8W (Above +30°C)
- Transmitter: 5.6W (+30°C to -30°C)
Battery & Charging
- Battery Run Time
- 10 Years Lifetime
- Batteries Required
- TLH-2450
Standards & Certifications
- Standards
- EN 50270: (EMC)NEWLINEIEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EUNEWLINEIEC/EN/UL/CSA 61010 (Electrical Safety)NEWLINEFCC / ICNEWLINERoHS, China RoHS
- NEMA Rating
- Type 4X, in accordance with NEMA 250
- Ingress Protection
- IP66/67
- IP66/67
Material Specifications
- Material
- 316L Stainless Steel
- 316L Stainless Steel
Others
- Weight
- Receiver 6.1 kg (13.4 lbs), Transmitter 6.0 kg (13.2 lbs)
- Response Time
- T90 less than 3 seconds
- Maximum Temperature
- +75 °C (+167 °F)
- Brand : Honeywell|Honeywell
- Weight : Receiver 6.1 kg (13.4 lbs), Transmitter 6.0 kg (13.2 lbs)
- Response Time : T90 less than 3 seconds
- Maximum Temperature : +75 °C (+167 °F)
- Sub-Category : Open Path Gas Detectors & Transmitters|Open Path Gas Detectors and Transmitters
- Weight range : Rx: 6.1 kg (13.4 lbs)|Tx: 6.0 kg (13.2 lb)
- Sensor Range : 60 m to 330 m (196 to 1,082 ft)
- Humidity Range : 0 to 99% RH (Non-Condensing)|0–99 % RH Non-condensing
- Minimum Temperature : -55 °C (-67 °F)|-55°C
- Alarm Settings : High 3 LEL.m|Low 1 LEL.m|Min 0.5 LEL.m
- Analog Output Signal Type : 4-20mA standard
- Analog Output Signal Current : 4 to 20 mA
- Battery Run Time : 10 Years Lifetime
- Batteries Required : TLH-2450
- Standards : EN 50270: (EMC)NEWLINEIEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EUNEWLINEIEC/EN/UL/CSA 61010 (Electrical Safety)NEWLINEFCC / ICNEWLINERoHS, China RoHS
- Features & Benefits : Advanced Alignment Scope|Automatic Optimal Alignment Test|Built-In Health Test and Logging|Electro-Optical Compartment and Module|Fast Response to Flammable Hydrocarbon Gas|Full Logging and Auto-Reporting|High-End Coaxial Measurement and Dual Reference with Complex Filtering and Advanced Algorithms|Honeywell Fixed Platform Universal Mount|Low Maintenance|No Field Calibration Required|Patented, High Dynamic Range, Transmission and Reception Technology|Provides Long Distance Fence-Line (Perimeter) Monitoring|Robust, Painted, Stainless Steel Housing|Two Compartments (Ex de) with Separate Electro-Optical Module from Connections
- Features : Bluetooth® enabled
- Material : 316L Stainless Steel|316L Stainless Steel
- Relay Rated Load : Max. 32 Vdc/ac, max. 2 A resistive load
- Relay Output Configuration : Relay 1 is Alarm Level 1, Relay 2 is Alarm Level 2, Relay 3 Indicates Faults
- Relay Activation Settings : Single Pole Double Throw (SPDT)
- Sensor Type : Open Path Infrared
- Sensing Method : Near Band Infrared
- Wireless Technology : Bluetooth (Range up to 20m)|Bluetooth® (range up to 20 m (66 ft)
- Visual Indicators : Blue: Bluetooth Pairing Mode|Green: Normal|Red: Alarm|Yellow: Fault
- Output Signal Type : 4 to 20 mA with HART®
- Number of Relay Outputs : 3
- NEMA Rating : Type 4X, in accordance with NEMA 250
- Mounting : Universal Mounting Bracket Included|Universal Mounting Bracket Included
- Maximum Pressure : 105.5 kPa|105.5 kPa (1055 mBar, non-compensated)
- Ingress Protection : IP66/67|IP66/67
- Gas Type : Flammable Hydrocarbon|Flammable Hydrocarbon
- Warm Up Time : Less than 1 Hour (Fully Stabilized)|Less than 5 min (Operational)
- Storage Temperature : -55 to +75°C
- Speed of Response : T90 < 3 sec
- Repeatability : ±0.4 LEL.m
- Power Requirement : 24 VDC
- Power Consumption : Receiver: 3.0W (Above +30°C)|Receiver: 4.8W (+30°C to -30°C)|Receiver: 7.4W (Below -30°C)|Transmitter: 11.8W (Below -30°C)|Transmitter: 3.8W (Above +30°C)|Transmitter: 5.6W (+30°C to -30°C)
- Path Length : 60 to 330 m
- Measuring Range : 0-5 LEL.m
- Dimension : 4.06 in dia x 12.8 in x 7.09 in
Data Sheet
Manuals and Guides
Software
Brochure
Certificate
Please sign in to view part numbers available for purchase based on your account Sign In
Please sign in to view part numbers available for purchase based on your account Sign In