Fixed extractive, 4-in-1 multi gas detector

Overview
sps-his-midas-m-aem
The Midas-M is a Fixed Extractive Single Point with 4-in-1 Multi Gas Detector to detect more than 30 gases - precisely, easily, quickly, that draws a sample locally or from a remote point to a sensor cartridge that is located inside the detector's chassis. A side range of toxic, flammable and oxygen gas sensor cartridges are available that enable detection of gases used or generated in the Semiconductor and other manufacturing industries.Features & Benefits:
  • Over *33 gases available with 2 year warranty : 17 gases available at launch
  • 4-in-1 multi smart sensor cartridge with on board * ‘e-calibration’ certificate
  • Modular design for easy to use and service (front, pump, sensor cartridge, main and base)
  • 3 built in relays (Form C) for Alarm 1, 2 and Fault
  • Power over Ethernet (PoE) communication
  • Keypad interface and remote web browser interface
  • Factory-calibrated sensors to reduce need for frequent gas testing
  • Isolated 0-21 mA analog output with fault and event reporting
  • Modbus/TCP Ethernet for easy connectivity to all control and alarm systems ports for control connectivity and service interaction
  • Robust extractive pump system (2 year lifetime) sampling up to 100 feet
Quick Specs:
  • Flow Rate: 500 mL/min
  • Transport Time: 2 to 30 seconds maximum
  • Sample Line Tubing: 0.125 in ID x 0.25 in OD
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • Honeywell

Dimensions & Weight

  • Size
    • H: 5.35 in W: 3.27 in D: 5.98 in
  • Sample Line Length
    • 30 m
  • Exhaust Length
    • 30 m
  • Overall Depth
    • 5.98 in

Standards & Certifications

  • Certificates and Standards
    • CE Marked Meets EN 50270:2015+AC:2016
    • EN 50270:2015
    • EN 50581:2012
    • EN 61000-6-4:2007 +A1:2011
    • EN 61010-1:2010
    • EN IEC 63000:2018
    • EN ISO/IEC 17050-1:2010
    • EN61000-6-4:2007+A1 ETL Approved UL 61010-1:2012 Ed.3 IEEE 802.3af-2003
    • UKCA Marked

Options

  • Display Operation key
    • 4-Button Interface Keypad
  • Enclosure Rating
    • NEMA 4
  • Series Name
    • Midas-M
  • Warranty
    • Sensor Cartridge: 2 Years
    • Transmitter Unit: 1 Year
  • Remote
    • Internet Browser Access via Ethernet

Configuration

  • Storage Temperature
    • 41 to 77°F
  • Exhaust Line Tubing
    • ID: 0.188 in OD: 0.25 in
  • Wiring Requirement
    • 2-Wire 14 AWG Max
    • Digital: CAT5 Cable or Equivalent: RJ45 Connector
  • Sample Line Tubing
    • ID: 0.125 in OD: 0.25 in
  • Effect of Position
    • No Effect in Typical Application
  • Bracket Material
    • Zinc Plated Steel
  • Transport Time
    • 2 to 25 sec
  • Visual Output
    • Power, Alarm Fault LEDs and Color TFT LCD
  • Tubing Length
    • 30 m
  • Relay Outputs
    • Relays (3) Rated 1.0 A @30 V DC or 0.5 A @125 V AC Max 10uA @10 mV Min Configurable as Normally Open or Closed and Latched or Unlatched
  • Communication
    • Lonworks
    • Modbus
    • PPP Protocol
    • Power Over Ethernet (PoE)
    • RS232C
    • TCP Ethernet
  • Ambient Port
    • In Line Air Filter Required
  • Instrument
    • 4-Digit Alphanumeric Display with Separate Units
    • Concentration Bar Graph for Each Channel and Other Icon Driven Indicators
  • Flow Rate
    • 600 ml/min

Features & Benefits

  • Features & Benefits
    • 3 Built In Relays (Form C) for Alarm 1, 2 and Fault
    • 4-in-1 Multi Smart Sensor Cartridge with on Board With ‘e-Calibration’ Certificate
    • Bright LEDs and Intuitive Icon Driven Large LCD Display with Individual Multicolor Backlit
    • CE Marked for Total Immunity to Radio Frequency Interference
    • Event Logging to Review Sensor History
    • Factory-Calibrated Sensors to Reduce the Need for Frequent Gas Testing
    • Keypad Interface and Remote Web Browser Interface
    • Modbus/TCP Ethernet for Easy Connectivity to All Control and Alarm Systems Ports for Control Connectivity and Service Interaction
    • Modular Design for Easy to Use and Service (Front, Pump, Sensor Cartridge, Main and Base)
    • Optional Line Integrity Test (LIT) Module to Detect a Leakage in Tubing
    • Over 33 Gases Available with 2 Year Warranty
    • Password Protected Menu Levels to Preserve System Integrity
    • Power Over Ethernet (PoE)
    • Reflex® Sensor Health Check for Improved Safety
    • Robust Extractive Pump System (2 Year Lifetime) Sampling Up to 100ft
    • TempraSure TM Temperature Compensation Technology

Performance Data

  • Power Consumption
    • ≤ 12.9W
  • Operating Voltage
    • 24 V DC (Nominal) -15 to +10% (20.4 to 26.4 V DC)
  • Analog Outputs
    • 3-Wire Sink, 3-Wire Source or 4-Wire Fully Isolated (0 to 21 mA for Each Channel)
  • Display Type
    • Multicolor Backlit LCD
  • Mounting
    • DIN Rail
    • Wall
  • Height
    • 5.35 in

Materials

  • Cover Material
    • Plastic (Polycarbonate)

Dimensions

  • Overall Width
    • 3.27 in

Applicability

  • For Use With
    • Chemical Vapor Deposition
    • Gas Cabinets
    • Wafer Dryers
    • Wafer Reactor

Alarm

  • Alarm Type
    • Dual Level Alarms Typically Set at 1/2 TLV and TLV

Brand

  • Brand
    • Honeywell

Dimensions & Weight

  • Size
    • H: 5.35 in W: 3.27 in D: 5.98 in
  • Sample Line Length
    • 30 m
  • Exhaust Length
    • 30 m
  • Overall Depth
    • 5.98 in

Standards & Certifications

  • Certificates and Standards
    • CE Marked Meets EN 50270:2015+AC:2016
    • EN 50270:2015
    • EN 50581:2012
    • EN 61000-6-4:2007 +A1:2011
    • EN 61010-1:2010
    • EN IEC 63000:2018
    • EN ISO/IEC 17050-1:2010
    • EN61000-6-4:2007+A1 ETL Approved UL 61010-1:2012 Ed.3 IEEE 802.3af-2003
    • UKCA Marked

Options

  • Display Operation key
    • 4-Button Interface Keypad
  • Enclosure Rating
    • NEMA 4
  • Series Name
    • Midas-M
  • Warranty
    • Sensor Cartridge: 2 Years
    • Transmitter Unit: 1 Year
  • Remote
    • Internet Browser Access via Ethernet

Configuration

  • Storage Temperature
    • 41 to 77°F
  • Exhaust Line Tubing
    • ID: 0.188 in OD: 0.25 in
  • Wiring Requirement
    • 2-Wire 14 AWG Max
    • Digital: CAT5 Cable or Equivalent: RJ45 Connector
  • Sample Line Tubing
    • ID: 0.125 in OD: 0.25 in
  • Effect of Position
    • No Effect in Typical Application
  • Bracket Material
    • Zinc Plated Steel
  • Transport Time
    • 2 to 25 sec
  • Visual Output
    • Power, Alarm Fault LEDs and Color TFT LCD
  • Tubing Length
    • 30 m
  • Relay Outputs
    • Relays (3) Rated 1.0 A @30 V DC or 0.5 A @125 V AC Max 10uA @10 mV Min Configurable as Normally Open or Closed and Latched or Unlatched
  • Communication
    • Lonworks
    • Modbus
    • PPP Protocol
    • Power Over Ethernet (PoE)
    • RS232C
    • TCP Ethernet
  • Ambient Port
    • In Line Air Filter Required
  • Instrument
    • 4-Digit Alphanumeric Display with Separate Units
    • Concentration Bar Graph for Each Channel and Other Icon Driven Indicators
  • Flow Rate
    • 600 ml/min

Features & Benefits

  • Features & Benefits
    • 3 Built In Relays (Form C) for Alarm 1, 2 and Fault
    • 4-in-1 Multi Smart Sensor Cartridge with on Board With ‘e-Calibration’ Certificate
    • Bright LEDs and Intuitive Icon Driven Large LCD Display with Individual Multicolor Backlit
    • CE Marked for Total Immunity to Radio Frequency Interference
    • Event Logging to Review Sensor History
    • Factory-Calibrated Sensors to Reduce the Need for Frequent Gas Testing
    • Keypad Interface and Remote Web Browser Interface
    • Modbus/TCP Ethernet for Easy Connectivity to All Control and Alarm Systems Ports for Control Connectivity and Service Interaction
    • Modular Design for Easy to Use and Service (Front, Pump, Sensor Cartridge, Main and Base)
    • Optional Line Integrity Test (LIT) Module to Detect a Leakage in Tubing
    • Over 33 Gases Available with 2 Year Warranty
    • Password Protected Menu Levels to Preserve System Integrity
    • Power Over Ethernet (PoE)
    • Reflex® Sensor Health Check for Improved Safety
    • Robust Extractive Pump System (2 Year Lifetime) Sampling Up to 100ft
    • TempraSure TM Temperature Compensation Technology

Performance Data

  • Power Consumption
    • ≤ 12.9W
  • Operating Voltage
    • 24 V DC (Nominal) -15 to +10% (20.4 to 26.4 V DC)
  • Analog Outputs
    • 3-Wire Sink, 3-Wire Source or 4-Wire Fully Isolated (0 to 21 mA for Each Channel)
  • Display Type
    • Multicolor Backlit LCD
  • Mounting
    • DIN Rail
    • Wall
  • Height
    • 5.35 in

Materials

  • Cover Material
    • Plastic (Polycarbonate)

Dimensions

  • Overall Width
    • 3.27 in

Applicability

  • For Use With
    • Chemical Vapor Deposition
    • Gas Cabinets
    • Wafer Dryers
    • Wafer Reactor

Alarm

  • Alarm Type
    • Dual Level Alarms Typically Set at 1/2 TLV and TLV
  • Brand : Honeywell
  • Size : H: 5.35 in W: 3.27 in D: 5.98 in
  • Certificates and Standards : CE Marked Meets EN 50270:2015+AC:2016|EN 50270:2015|EN 50581:2012|EN 61000-6-4:2007 +A1:2011|EN 61010-1:2010|EN IEC 63000:2018|EN ISO/IEC 17050-1:2010|EN61000-6-4:2007+A1 ETL Approved UL 61010-1:2012 Ed.3 IEEE 802.3af-2003|UKCA Marked
  • Display Operation key : 4-Button Interface Keypad
  • Storage Temperature : 41 to 77°F
  • Features & Benefits : 3 Built In Relays (Form C) for Alarm 1, 2 and Fault|4-in-1 Multi Smart Sensor Cartridge with on Board With ‘e-Calibration’ Certificate|Bright LEDs and Intuitive Icon Driven Large LCD Display with Individual Multicolor Backlit|CE Marked for Total Immunity to Radio Frequency Interference|Event Logging to Review Sensor History|Factory-Calibrated Sensors to Reduce the Need for Frequent Gas Testing|Keypad Interface and Remote Web Browser Interface|Modbus/TCP Ethernet for Easy Connectivity to All Control and Alarm Systems Ports for Control Connectivity and Service Interaction|Modular Design for Easy to Use and Service (Front, Pump, Sensor Cartridge, Main and Base)|Optional Line Integrity Test (LIT) Module to Detect a Leakage in Tubing|Over 33 Gases Available with 2 Year Warranty|Password Protected Menu Levels to Preserve System Integrity|Power Over Ethernet (PoE)|Reflex® Sensor Health Check for Improved Safety|Robust Extractive Pump System (2 Year Lifetime) Sampling Up to 100ft|TempraSure TM Temperature Compensation Technology
  • Exhaust Line Tubing : ID: 0.188 in OD: 0.25 in
  • Wiring Requirement : 2-Wire 14 AWG Max|Digital: CAT5 Cable or Equivalent: RJ45 Connector
  • Sample Line Tubing : ID: 0.125 in OD: 0.25 in
  • Sample Line Length : 30 m
  • Effect of Position : No Effect in Typical Application
  • Power Consumption : ≤ 12.9W
  • Operating Voltage : 24 V DC (Nominal) -15 to +10% (20.4 to 26.4 V DC)
  • Enclosure Rating : NEMA 4
  • Bracket Material : Zinc Plated Steel
  • Transport Time : 2 to 25 sec
  • Exhaust Length : 30 m
  • Cover Material : Plastic (Polycarbonate)
  • Analog Outputs : 3-Wire Sink, 3-Wire Source or 4-Wire Fully Isolated (0 to 21 mA for Each Channel)
  • Visual Output : Power, Alarm Fault LEDs and Color TFT LCD
  • Tubing Length : 30 m
  • Relay Outputs : Relays (3) Rated 1.0 A @30 V DC or 0.5 A @125 V AC Max 10uA @10 mV Min Configurable as Normally Open or Closed and Latched or Unlatched
  • Overall Width : 3.27 in
  • Overall Depth : 5.98 in
  • Communication : Lonworks|Modbus|PPP Protocol|Power Over Ethernet (PoE)|RS232C|TCP Ethernet
  • For Use With : Chemical Vapor Deposition|Gas Cabinets|Wafer Dryers|Wafer Reactor
  • Display Type : Multicolor Backlit LCD
  • Ambient Port : In Line Air Filter Required
  • Series Name : Midas-M
  • Instrument : 4-Digit Alphanumeric Display with Separate Units|Concentration Bar Graph for Each Channel and Other Icon Driven Indicators
  • Alarm Type : Dual Level Alarms Typically Set at 1/2 TLV and TLV
  • Flow Rate : 600 ml/min
  • Warranty : Sensor Cartridge: 2 Years|Transmitter Unit: 1 Year
  • Mounting : DIN Rail|Wall
  • Remote : Internet Browser Access via Ethernet
  • Height : 5.35 in
Data Sheet
Name
Description
File Size
Date
Size
Midas®-M CARBON MONOXIDE (CO) Data Sheet
application/pdf 207.2 KB
7/27/2021
207.2 KB
Midas®-M CHLORINE (Cl2) Data Sheet
application/pdf 211.54 KB
7/27/2021
211.54 KB
Midas®-M DATASHEET
application/pdf 372.08 KB
7/27/2021
372.08 KB
Midas®-M OZONE (O3) Data Sheet
application/pdf 223 KB
7/27/2021
223 KB
Midas®-M HYDROGEN (H2) Data Sheet
application/pdf 213.77 KB
7/27/2021
213.77 KB
Midas®-M SILANE GROUP (SIH4 SI2H6) Data Sheet
application/pdf 215.26 KB
7/27/2021
215.26 KB
Midas®-M MINERAL ACIDS (HF GROUP) Data Sheet
application/pdf 216.27 KB
7/27/2021
216.27 KB
Midas®-M PHOSPHINE (PH3) Data Sheet
application/pdf 216.31 KB
7/27/2021
216.31 KB
Midas®-M AMMONIA (NH3) Data Sheet
application/pdf 210.39 KB
7/27/2021
210.39 KB
Midas®-M OXYGEN (O2) Data Sheet
application/pdf 209.52 KB
7/27/2021
209.52 KB
Midas®-M SULPHUR DIOXIDE (SO2) Data Sheet
application/pdf 215.06 KB
7/27/2021
215.06 KB
Midas-M Gas Specifications - Data Sheet
application/pdf 1.18 MB
11/16/2022
1.18 MB
Manuals and Guides
Name
Description
File Size
Date
Size
Midas®-M MULTI GAS RELAY MODULE QSG
application/postscript 3.74 MB
7/27/2021
3.74 MB
Midas-M EU Declaration of Conformity
application/pdf 161.48 KB
1/7/2022
161.48 KB
Midas®-M - User Manual
application/pdf 4.66 MB
8/24/2022
4.66 MB
Midas®-M MULTI GAS SENSOR CARTRIDGE QSG
application/postscript 2.75 MB
7/27/2021
2.75 MB
Midas®-M MULTI GAS TRANSMITTER QSG
application/postscript 6.45 MB
7/27/2021
6.45 MB
Brochure
Name
Description
File Size
Date
Size
Midas®-M BROCHURE
application/pdf 3.81 MB
7/27/2021
3.81 MB
Technical Note
Name
Description
File Size
Date
Size
Midas®-M Technical Note - 1998-0963 Rev 1
application/pdf 190.98 KB
10/26/2022
190.98 KB
Certificate
Name
Description
File Size
Date
Size
Midas-M Intertek Authorization to Mark
application/pdf 1.06 MB
1/7/2022
1.06 MB
EU Declaration of Conformity - Midas and Pyrolyzer
application/pdf 160.95 KB
11/24/2021
160.95 KB
Application Note
Name
Description
File Size
Date
Size
Midas®-M Application Note
application/pdf 2.16 MB
3/30/2023
2.16 MB
Name
Description
File Size
Date
Size
Midas-M Intertek Authorization to Mark
application/pdf 1.06 MB
1/7/2022
1.06 MB
EU Declaration of Conformity - Midas and Pyrolyzer
application/pdf 160.95 KB
11/24/2021
160.95 KB
Midas®-M Application Note
application/pdf 2.16 MB
3/30/2023
2.16 MB
Midas®-M MULTI GAS RELAY MODULE QSG
application/postscript 3.74 MB
7/27/2021
3.74 MB
Midas-M EU Declaration of Conformity
application/pdf 161.48 KB
1/7/2022
161.48 KB
Midas®-M - User Manual
application/pdf 4.66 MB
8/24/2022
4.66 MB
Midas®-M CARBON MONOXIDE (CO) Data Sheet
application/pdf 207.2 KB
7/27/2021
207.2 KB
Midas®-M CHLORINE (Cl2) Data Sheet
application/pdf 211.54 KB
7/27/2021
211.54 KB
Midas®-M DATASHEET
application/pdf 372.08 KB
7/27/2021
372.08 KB
Midas®-M BROCHURE
application/pdf 3.81 MB
7/27/2021
3.81 MB
Midas®-M OZONE (O3) Data Sheet
application/pdf 223 KB
7/27/2021
223 KB
Midas®-M HYDROGEN (H2) Data Sheet
application/pdf 213.77 KB
7/27/2021
213.77 KB
Midas®-M MULTI GAS SENSOR CARTRIDGE QSG
application/postscript 2.75 MB
7/27/2021
2.75 MB
Midas®-M SILANE GROUP (SIH4 SI2H6) Data Sheet
application/pdf 215.26 KB
7/27/2021
215.26 KB
Midas®-M MINERAL ACIDS (HF GROUP) Data Sheet
application/pdf 216.27 KB
7/27/2021
216.27 KB
Midas®-M PHOSPHINE (PH3) Data Sheet
application/pdf 216.31 KB
7/27/2021
216.31 KB
Midas®-M AMMONIA (NH3) Data Sheet
application/pdf 210.39 KB
7/27/2021
210.39 KB
Midas®-M MULTI GAS TRANSMITTER QSG
application/postscript 6.45 MB
7/27/2021
6.45 MB
Midas®-M OXYGEN (O2) Data Sheet
application/pdf 209.52 KB
7/27/2021
209.52 KB
Midas®-M SULPHUR DIOXIDE (SO2) Data Sheet
application/pdf 215.06 KB
7/27/2021
215.06 KB
Midas-M Gas Specifications - Data Sheet
application/pdf 1.18 MB
11/16/2022
1.18 MB
Midas®-M Technical Note - 1998-0963 Rev 1
application/pdf 190.98 KB
10/26/2022
190.98 KB
Showing 1 to 10 of 47 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
MM-B01
Midas-M 4-20mA Base Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-B01
Midas-M 4-20mA Base Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-B02
Midas-M TCPIP Base Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-B02
Midas-M TCPIP Base Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-CAT
Midas-M Cartridge wo Smart Cell
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-CAT
Midas-M Cartridge wo Smart Cell
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-FIL
Midas-M Filter Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-FIL
Midas-M Filter Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-FRT
Midas-M Front Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-FRT
Midas-M Front Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-LIT
Midas-M LIT
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-LIT
Midas-M LIT
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-LPM
Midas-M Pump Module - LIT
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-LPM
Midas-M Pump Module - LIT
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-M01
Midas-M 4-20mA Main Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-M01
Midas-M 4-20mA Main Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-M02
Midas-M TCPIP Main Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-M02
Midas-M TCPIP Main Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-PM
Midas-M Pump Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
MM-PM
Midas-M Pump Module
https://s7d1.scene7.com/is/image/Honeywell65/sps-his-midas-m-aem
Feedback