    Gas Sensors

    CRIR Series

    Standard range of 400 ppm to 2000 ppm, up to 10000 ppm extended range. Accuracy of ±40 ppm ±3% of reading and ±50 ppm ±5% of reading.

    Overview

    The CRIR Series are single channel, non-dispersive infrared (NDIR) sensors. Within the CRIR M1 and CRIR E1 is a sensing chamber with an infrared source at one end and a detector fitted with an optical filter at the other end. The source emits radiation at wavelengths which include the absorption band of CO2.

    The filter blocks wavelengths which are not sensitive to the presence of CO2, thereby increasing selectivity and sensitivity. As the light passes through the sensing chamber, a fraction is absorbed if CO2 is present. The difference between the light emitted by the source and received by the detector can then be converted to a CO2 concentration reading.

    The Automatic Baseline Correction (ABC) function can automatically calibrate the sensor’s lowest reading over a pre-configured interval to 400 ppm CO2. This enhances long term stability and may eliminate the need for calibration.

    Value to Customers
    • Small size
    • Maintenance free for normal indoor applications
    • Enhanced long term stability
    • Higher accuracy:
      • CRIR M1: ±40 ppm ±3% of reading
      • CRIR E1: ±50 ppm ±5% of reading
    • Consistency and repeatability
    • Easy integration
    Features
    • Single channel, non-dispersive infrared technology
    • Automatic Baseline Correction
    • Temperature compensation
    • UART digital interface
    Potential Applications
    • HVAC, demand controlled ventilation
    • Indoor air quality (IAQ) measurement
    • Air purification systems
    • Smart /IoT (Internet of Things) systems
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    CRIR E1 Commercial Carbon Dioxide Sensor Datasheet
    application/pdf 199.25 KB
    7/15/2021
    199.25 KB
    CRIR M1 Commercial Carbon Dioxide Sensor Datasheet
    application/pdf 230.03 KB
    7/15/2021
    230.03 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    CRIR E1 Commercial Carbon Dioxide Sensor User Guide
    application/pdf 373.52 KB
    7/15/2021
    373.52 KB
    CRIR M1 Commercial Carbon Dioxide Sensor User Guide
    application/pdf 368.05 KB
    7/15/2021
    368.05 KB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    Industrial Applications: Going Beyond Limits
    application/pdf 16.69 MB
    11/17/2022
    16.69 MB
    Controlling the Future with Technology
    application/pdf 11.8 MB
    3/7/2023
    11.8 MB
    Detecting the Third Element, Honeywell Gas Sensing
    application/pdf 4.87 MB
    6/7/2022
    4.87 MB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Solutions For Healthier Air & HVAC Systems
    application/pdf 3.88 MB
    5/31/2022
    3.88 MB
    Product Photo
    Name
    Description
    File Size
    Date
    Size
    CRIR Series Product Photo
    application/zip 278.92 KB
    7/15/2021
    278.92 KB
    Name
    Description
    File Size
    Date
    Size
    CRIR E1 Commercial Carbon Dioxide Sensor User Guide
    application/pdf 373.52 KB
    7/15/2021
    373.52 KB
    Industrial Applications: Going Beyond Limits
    application/pdf 16.69 MB
    11/17/2022
    16.69 MB
    Controlling the Future with Technology
    application/pdf 11.8 MB
    3/7/2023
    11.8 MB
    Detecting the Third Element, Honeywell Gas Sensing
    application/pdf 4.87 MB
    6/7/2022
    4.87 MB
    CRIR E1 Commercial Carbon Dioxide Sensor Datasheet
    application/pdf 199.25 KB
    7/15/2021
    199.25 KB
    Solutions For Healthier Air & HVAC Systems
    application/pdf 3.88 MB
    5/31/2022
    3.88 MB
    CRIR M1 Commercial Carbon Dioxide Sensor User Guide
    application/pdf 368.05 KB
    7/15/2021
    368.05 KB
    CRIR Series Product Photo
    application/zip 278.92 KB
    7/15/2021
    278.92 KB
    CRIR M1 Commercial Carbon Dioxide Sensor Datasheet
    application/pdf 230.03 KB
    7/15/2021
    230.03 KB
    Name
    Description
    File Size
    Date
    Size
    CRIR E1 Commercial Carbon Dioxide Sensor Datasheet
    199.25 KB
    7/15/2021
    CRIR M1 Commercial Carbon Dioxide Sensor Datasheet
    230.03 KB
    7/15/2021
    CRIR E1 Commercial Carbon Dioxide Sensor User Guide
    373.52 KB
    7/15/2021
    CRIR M1 Commercial Carbon Dioxide Sensor User Guide
    368.05 KB
    7/15/2021
    Industrial Applications: Going Beyond Limits
    16.69 MB
    11/17/2022
    Controlling the Future with Technology
    11.8 MB
    3/7/2023
    Detecting the Third Element, Honeywell Gas Sensing
    4.87 MB
    6/7/2022
    Solutions For Healthier Air & HVAC Systems
    3.88 MB
    5/31/2022
    CRIR Series Product Photo
    278.92 KB
    7/15/2021
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    C06-0800-000
    CRIR E1 Commercial Carbon Dioxide Sensor, 400 ppm to 2000 ppm, up to 5000 ppm extended range
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-crir-e1-ciid-179514
    C06-0800-000
    CRIR E1 Commercial Carbon Dioxide Sensor, 400 ppm to 2000 ppm, up to 5000 ppm extended range
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-crir-e1-ciid-179514
    C06-0801-000
    Carbon Dioxide CO2 NDIR Sensor CRIR M1 (400-200010000ppm) Honeywell (For commercial applications)
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-crir-e1-ciid-179514
    C06-0801-000
    Carbon Dioxide CO2 NDIR Sensor CRIR M1 (400-200010000ppm) Honeywell (For commercial applications)
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-crir-e1-ciid-179514
    C06-0802-000
    COMMERCIAL NDIR CO2 SENSOR,CRIR-M1U
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-crir-e1-ciid-179514
    C06-0802-000
    COMMERCIAL NDIR CO2 SENSOR,CRIR-M1U
    https://s7d1.scene7.com/is/image/Honeywell65/sps-siot-crir-e1-ciid-179514