Products
Products
Part Numbers
General Content
/content/sps/au/en/search-results.html

Photoionization Detectors (PID)

MultiRAE

Wireless, portable multi-gas monitor with advanced VOC detection

Overview
his-rae-multirae-front-hires
MultiRAE is the most advanced portable chemical detector on the market. With the flexibility of up to six gas sensors and the convenience of wireless portability, this multi-gas monitor is versatile and customizable, while delivering real-time access to instrument readings and alarm status from any location. Choose from 25 sensor options including LEL, PID, NDIR, and exotics that can be easily changed in the field. With five built-in alarms, including man down, and wireless connectivity to your command center, MultiRAE delivers vital information for fast incident response.Features and Benefits:
  • Optional integrated wireless
  • 25 field-interchangeable sensor options, including PID, NDIR, and exotics like ammonia, chlorine, and formaldehyde
  • Five local and remote alarms, including man down
  • Dust-tight and waterproof (IP65-rated)
  • Rugged design
  • Onboard gas libraries include 190 VOCs and 55 combustible gases
  • Longest battery run-time in its class
  • Intuitive, icon-driven interface
  • Flippable screen
  • Large buttons for easy navigation even with up to three glove layers
  • Continuous data logging — six months for five sensors 24/7
  • Fully automated bump testing and calibration with AutoRAE 2
  • Device Management with Honeywell Sotera™ Express
Application:
  • Clandestine Labs
  • Confined Space Entry
  • Emergency Response
  • Environmental Cleanups/ Remediation
  • Exploration
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Residential Calls
  • Urban Search & Rescue
  • Venue Protection
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 31 ounce av
    • 880 gram
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Weight range
    • 880 g gram

Category

  • Sub-Category
    • Gas Monitor
    • Premium-Gas

Range

  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent
  • Sensor Range
    • Carbon Dioxide (CO2) 0 to 50,000 ppm, Ammonia (NH3) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Carbon Monoxide (CO), EXT. RANGE 0 to 2,000 ppm, Carbon Monoxide (CO), H2-COMP. 0 to 2,000 ppm, Carbon Monoxide (CO) + 0 to 500 ppm, Hydrogen Sulfide (H2S) COMBO 0 to 200 ppm, Chlorine (CL2) 0 to 50 ppm, Chlorine Dioxide (CLO2) 0 to 1 ppm, Ethylene Oxide (ETO-A) 0 to 100 ppm, Ethylene Oxide (ETO-B) 0 to 10 ppm, Formaldehyde (HCHO) 0 to 10 ppm, Hydrogen Cynaide (HCN) 0 to 50 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Methyl Mercaptan (CH3-SH) 0 to 10 ppm, Nitric Oxide (NO) 0 to 250 ppm, Nitrogen Dioxide (NO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol., Oxygen (LIQ O2) 0 to 30% Vol., Phosphine (PH3) 0 to 20 ppm, Phosphine (PH3 H) 0 to 20 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Features

  • Alarm Included
    • Yes
  • Series Name
    • MultiRAE
  • Languages
    • Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish

Alarm

  • Alarm Type
    • Audible (95 dB @30 cm)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)

Battery & Charging

  • Batteries Required
    • Yes
  • Batteries Included
    • Yes
  • Battery Run Time
    • 12-18 hours
    • AA Batteries (6 Hours) hours
    • Extended Duration Li-Ion (18 Hours) hours
    • Rechargeable Li-Ion (12 Hours) hours
  • Charging Time
    • 6 hours
    • 9 hours

Calibration

  • Calibration Procedures
    • AutoRAE 2 Test
    • Bump Test
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual

Certifications

  • Certifications - Performance
    • ISA-12.13.01
    • LEL CSA C22.2 No. 152
    • Performance Tests: MIL-STD-810G and 461F
  • Standards
    • ATEX: 0575 II 1G Ex ia IIC T4 Ga
    • ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed
    • ATEX: I M1 Ex ia I Ma
    • CSA: Class I, Div 1, Group A, B, C, D, T4
    • CSA: Class II, Div 1, Group E, F, G T85°C
    • IECEx/ANZEx: Ex ia I Ma
    • IECEx/ANZEx: Ex ia IIC T4 Ga
    • IECEx/ANZEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: Ex ia IIC T4 Ga
    • IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: I M1 Ex ia I Ma

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Display

  • Display Included
    • Yes
  • Display Readout
    • Battery Status, Datalogging On/Off
    • Man Down Alarm On/Off
    • PID Measurement Gas and Correction Factor
    • Real-Time Reading of Gas Concentrations
    • Visual Compliance Indicator
    • Wireless On/Off and Reception Quality, STEL, TWA, Peak, and Minimum Values
  • Display Matrix
    • 128 x 160
  • Display Type
    • Monochrome Graphic Display with Backlighting

Features & Benefits

  • Features & Benefits
    • Device Management with Honeywell SafetySuite
    • Extensive On-Board Gas Libraries (190 VOCs and 55 Combustible Gases)
    • Highly Versatile and Customizable
    • Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field
    • Largest Display In Its Class
    • Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions Including Man Down Alarm
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • User-Configurable Datalogging Intervals

Sampling

  • Sampling Pump Included
    • Yes
  • Sampling Pump Range
    • 100ft (30m) meter
  • Sampling Pump Rate
    • 250

Sensor

  • Number of Sensors Included
    • 25
  • Sensor Type
    • PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR

Warranty

  • Warranty
    • 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components and Catalytic LEL Sensors
    • 3 Years on CO and H2S Sensors
    • 4 Years on Liq O2 Sensors

Wireless

  • Wireless Technology
    • MESH, Wifi, BLE
  • Wireless Enabled
    • Yes

Additional Specifications

  • External Calibration
    • AutoRAE 2 Test and Calibration System
  • Replacement Parts
    • 25 Intelligent Interchangeable Field-Replaceable Sensors
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Decibels
    • 95 decibel

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Dimensions & Weight

  • Size
    • H: 7.6 in W: 3.8 in D: 2.6 in

Technical Specifications

  • Communication and Data Download
    • Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System
    • Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)
  • Operating Frequency Range
    • ISM License Free Band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
  • Dust and Water Resistance
    • IP65
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Wireless Network
    • EchoView Host-Based Closed-Loop System
    • ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Range
    • MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)
    • MultiRAE to RAELink3 [Z1] Mesh modem 330 ft (100m)
    • MultiRAE to Wi-Fi Access Point 330 ft (100m)
  • Radio Module
    • Supports RM900A
  • Model Number
    • MultiRAE
    • PGM-6228
  • Keypad Type
    • 3 Operation and Programming Keys (Mode, Y/+, and N/-)
  • Sampling
    • Built-In Pump. Auto Shutoff in Low-Flow Conditions
  • EMC/RFI
    • EMC Directive: 2004/108/EC
  • Tests
    • Automatic Bump Test

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Aviation
    • Chemical
    • Clandestine Drug Labs
    • Environmental
    • HazMat Response
    • Industrial Hygiene
    • Oil and Gas
    • Personal Protection
    • Pharmaceutical
    • Shipping/Marine

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 31 ounce av
    • 880 gram
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Weight range
    • 880 g gram

Category

  • Sub-Category
    • Gas Monitor
    • Premium-Gas

Range

  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent
  • Sensor Range
    • Carbon Dioxide (CO2) 0 to 50,000 ppm, Ammonia (NH3) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Carbon Monoxide (CO), EXT. RANGE 0 to 2,000 ppm, Carbon Monoxide (CO), H2-COMP. 0 to 2,000 ppm, Carbon Monoxide (CO) + 0 to 500 ppm, Hydrogen Sulfide (H2S) COMBO 0 to 200 ppm, Chlorine (CL2) 0 to 50 ppm, Chlorine Dioxide (CLO2) 0 to 1 ppm, Ethylene Oxide (ETO-A) 0 to 100 ppm, Ethylene Oxide (ETO-B) 0 to 10 ppm, Formaldehyde (HCHO) 0 to 10 ppm, Hydrogen Cynaide (HCN) 0 to 50 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Methyl Mercaptan (CH3-SH) 0 to 10 ppm, Nitric Oxide (NO) 0 to 250 ppm, Nitrogen Dioxide (NO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol., Oxygen (LIQ O2) 0 to 30% Vol., Phosphine (PH3) 0 to 20 ppm, Phosphine (PH3 H) 0 to 20 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Features

  • Alarm Included
    • Yes
  • Series Name
    • MultiRAE
  • Languages
    • Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish

Alarm

  • Alarm Type
    • Audible (95 dB @30 cm)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)

Battery & Charging

  • Batteries Required
    • Yes
  • Batteries Included
    • Yes
  • Battery Run Time
    • 12-18 hours
    • AA Batteries (6 Hours) hours
    • Extended Duration Li-Ion (18 Hours) hours
    • Rechargeable Li-Ion (12 Hours) hours
  • Charging Time
    • 6 hours
    • 9 hours

Calibration

  • Calibration Procedures
    • AutoRAE 2 Test
    • Bump Test
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual

Certifications

  • Certifications - Performance
    • ISA-12.13.01
    • LEL CSA C22.2 No. 152
    • Performance Tests: MIL-STD-810G and 461F
  • Standards
    • ATEX: 0575 II 1G Ex ia IIC T4 Ga
    • ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed
    • ATEX: I M1 Ex ia I Ma
    • CSA: Class I, Div 1, Group A, B, C, D, T4
    • CSA: Class II, Div 1, Group E, F, G T85°C
    • IECEx/ANZEx: Ex ia I Ma
    • IECEx/ANZEx: Ex ia IIC T4 Ga
    • IECEx/ANZEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: Ex ia IIC T4 Ga
    • IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: I M1 Ex ia I Ma

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Display

  • Display Included
    • Yes
  • Display Readout
    • Battery Status, Datalogging On/Off
    • Man Down Alarm On/Off
    • PID Measurement Gas and Correction Factor
    • Real-Time Reading of Gas Concentrations
    • Visual Compliance Indicator
    • Wireless On/Off and Reception Quality, STEL, TWA, Peak, and Minimum Values
  • Display Matrix
    • 128 x 160
  • Display Type
    • Monochrome Graphic Display with Backlighting

Features & Benefits

  • Features & Benefits
    • Device Management with Honeywell SafetySuite
    • Extensive On-Board Gas Libraries (190 VOCs and 55 Combustible Gases)
    • Highly Versatile and Customizable
    • Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field
    • Largest Display In Its Class
    • Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions Including Man Down Alarm
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • User-Configurable Datalogging Intervals

Sampling

  • Sampling Pump Included
    • Yes
  • Sampling Pump Range
    • 100ft (30m) meter
  • Sampling Pump Rate
    • 250

Sensor

  • Number of Sensors Included
    • 25
  • Sensor Type
    • PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR

Warranty

  • Warranty
    • 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components and Catalytic LEL Sensors
    • 3 Years on CO and H2S Sensors
    • 4 Years on Liq O2 Sensors

Wireless

  • Wireless Technology
    • MESH, Wifi, BLE
  • Wireless Enabled
    • Yes

Additional Specifications

  • External Calibration
    • AutoRAE 2 Test and Calibration System
  • Replacement Parts
    • 25 Intelligent Interchangeable Field-Replaceable Sensors
  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Decibels
    • 95 decibel

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Dimensions & Weight

  • Size
    • H: 7.6 in W: 3.8 in D: 2.6 in

Technical Specifications

  • Communication and Data Download
    • Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System
    • Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)
  • Operating Frequency Range
    • ISM License Free Band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
  • Dust and Water Resistance
    • IP65
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Wireless Network
    • EchoView Host-Based Closed-Loop System
    • ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Range
    • MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)
    • MultiRAE to RAELink3 [Z1] Mesh modem 330 ft (100m)
    • MultiRAE to Wi-Fi Access Point 330 ft (100m)
  • Radio Module
    • Supports RM900A
  • Model Number
    • MultiRAE
    • PGM-6228
  • Keypad Type
    • 3 Operation and Programming Keys (Mode, Y/+, and N/-)
  • Sampling
    • Built-In Pump. Auto Shutoff in Low-Flow Conditions
  • EMC/RFI
    • EMC Directive: 2004/108/EC
  • Tests
    • Automatic Bump Test

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Aviation
    • Chemical
    • Clandestine Drug Labs
    • Environmental
    • HazMat Response
    • Industrial Hygiene
    • Oil and Gas
    • Personal Protection
    • Pharmaceutical
    • Shipping/Marine
  • Brand : Honeywell RAE Systems|RAE
  • Weight : 31 ounce av|880 gram
  • Sub-Category : Gas Monitor|Premium-Gas
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Weight range : 880 g gram
  • Humidity Range : 0 to 95% RH (Non-Condensing) percent|0%-95% percent
  • Sensor Range : Carbon Dioxide (CO2) 0 to 50,000 ppm, Ammonia (NH3) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Carbon Monoxide (CO), EXT. RANGE 0 to 2,000 ppm, Carbon Monoxide (CO), H2-COMP. 0 to 2,000 ppm, Carbon Monoxide (CO) + 0 to 500 ppm, Hydrogen Sulfide (H2S) COMBO 0 to 200 ppm, Chlorine (CL2) 0 to 50 ppm, Chlorine Dioxide (CLO2) 0 to 1 ppm, Ethylene Oxide (ETO-A) 0 to 100 ppm, Ethylene Oxide (ETO-B) 0 to 10 ppm, Formaldehyde (HCHO) 0 to 10 ppm, Hydrogen Cynaide (HCN) 0 to 50 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Methyl Mercaptan (CH3-SH) 0 to 10 ppm, Nitric Oxide (NO) 0 to 250 ppm, Nitrogen Dioxide (NO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol., Oxygen (LIQ O2) 0 to 30% Vol., Phosphine (PH3) 0 to 20 ppm, Phosphine (PH3 H) 0 to 20 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm|NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Minimum Temperature : -20|-20 degree Celsius|-4 degree Fahrenheit
  • Maximum Temperature : 122 degree Fahrenheit|50|50 degree Celsius
  • Alarm Included : Yes
  • Alarm Type : Audible (95 dB @30 cm)|Vibrating|Visual (Flashing Bright Red LEDs)
  • Batteries Required : Yes
  • Batteries Included : Yes
  • Battery Run Time : 12-18 hours|AA Batteries (6 Hours) hours|Extended Duration Li-Ion (18 Hours) hours|Rechargeable Li-Ion (12 Hours) hours
  • Charging Time : 6 hours|9 hours
  • Calibration Procedures : AutoRAE 2 Test|Bump Test
  • Calibration : Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Certifications - Performance : ISA-12.13.01|LEL CSA C22.2 No. 152|Performance Tests: MIL-STD-810G and 461F
  • Standards : ATEX: 0575 II 1G Ex ia IIC T4 Ga|ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed|ATEX: I M1 Ex ia I Ma|CSA: Class I, Div 1, Group A, B, C, D, T4|CSA: Class II, Div 1, Group E, F, G T85°C|IECEx/ANZEx: Ex ia I Ma|IECEx/ANZEx: Ex ia IIC T4 Ga|IECEx/ANZEx: Ex ia d IIC T4 Gb with IR Sensor Installed|IECEx: Ex ia IIC T4 Ga|IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed|IECEx: I M1 Ex ia I Ma
  • Datalogging Interval : 1 min
  • Datalogging Capable : Yes
  • Datalogging : Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)|User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
  • Display Included : Yes
  • Display Readout : Battery Status, Datalogging On/Off|Man Down Alarm On/Off|PID Measurement Gas and Correction Factor|Real-Time Reading of Gas Concentrations|Visual Compliance Indicator|Wireless On/Off and Reception Quality, STEL, TWA, Peak, and Minimum Values
  • Display Matrix : 128 x 160
  • Display Type : Monochrome Graphic Display with Backlighting
  • Features & Benefits : Device Management with Honeywell SafetySuite|Extensive On-Board Gas Libraries (190 VOCs and 55 Combustible Gases)|Highly Versatile and Customizable|Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field|Largest Display In Its Class|Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions Including Man Down Alarm|Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected|User-Configurable Datalogging Intervals
  • Sampling Pump Included : Yes
  • Sampling Pump Range : 100ft (30m) meter
  • Sampling Pump Rate : 250
  • Number of Sensors Included : 25
  • Sensor Type : PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR
  • Warranty : 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts|2 Years on Non-Consumable Components and Catalytic LEL Sensors|3 Years on CO and H2S Sensors|4 Years on Liq O2 Sensors
  • Wireless Technology : MESH, Wifi, BLE
  • Wireless Enabled : Yes
  • External Calibration : AutoRAE 2 Test and Calibration System
  • Ingress Protection : IP65|IP65
  • Replacement Parts : 25 Intelligent Interchangeable Field-Replaceable Sensors
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • Decibels : 95 decibel
  • Size : H: 7.6 in W: 3.8 in D: 2.6 in
  • Communication and Data Download : Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System|Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)
  • Operating Frequency Range : ISM License Free Band. IEEE 802.15.4 Sub 1GHz, Wi-Fi 802.11 b/g
  • Dust and Water Resistance : IP65
  • Wireless Approvals : CE RandTTE|FCC Part 15
  • Wireless Network : EchoView Host-Based Closed-Loop System|ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Range : MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)|MultiRAE to RAELink3 [Z1] Mesh modem 330 ft (100m)|MultiRAE to Wi-Fi Access Point 330 ft (100m)
  • Radio Module : Supports RM900A
  • Power Source : Battery
  • Model Number : MultiRAE|PGM-6228
  • Series Name : MultiRAE
  • Keypad Type : 3 Operation and Programming Keys (Mode, Y/+, and N/-)
  • Application : Aviation|Chemical|Clandestine Drug Labs|Environmental|HazMat Response|Industrial Hygiene|Oil and Gas|Personal Protection|Pharmaceutical|Shipping/Marine
  • Languages : Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
  • Sampling : Built-In Pump. Auto Shutoff in Low-Flow Conditions
  • EMC/RFI : EMC Directive: 2004/108/EC
  • Tests : Automatic Bump Test
Data Sheet
Name
Description
File Size
Date
Size
MultiRAE Data Sheet
application/pdf 124.22 KB
7/15/2021
124.22 KB
Manuals and Guides
Name
Description
File Size
Date
Size
MultiRAE User Manual - UK
application/pdf 13.84 MB
5/10/2024
13.84 MB
MultiRAE User Manual - FR
application/pdf 13.77 MB
5/7/2024
13.77 MB
MultiRAE User Manual - ES
application/pdf 13.74 MB
5/7/2024
13.74 MB
MultiRAE User's Guide - NL
application/pdf 4.26 MB
7/15/2021
4.26 MB
MultiRAE User Manual - DE
application/pdf 13.71 MB
5/7/2024
13.71 MB
MultiRAE User Manual - PT
application/pdf 13.72 MB
5/7/2024
13.72 MB
MultiRAE User Manual - EN
application/pdf 13.7 MB
5/2/2024
13.7 MB
MultiRAE User Manual - IT
application/pdf 13.73 MB
5/8/2024
13.73 MB
MultiRAE User Manual - KO
application/pdf 14.01 MB
5/8/2024
14.01 MB
MultiRAE User Guide
application/pdf 8.12 MB
7/15/2021
8.12 MB
MultiRAE (Pumped Models) User's Guide - EN
application/pdf 898.78 KB
11/15/2023
898.78 KB
MultiRAE (Diffusion) Quick Reference Guide
application/pdf 595.58 KB
12/13/2023
595.58 KB
MultiRAE User's Guide - RU
application/pdf 5.05 MB
7/15/2021
5.05 MB
MultiRAE User Manual - JP
application/pdf 14.13 MB
5/8/2024
14.13 MB
Firmware
Name
Description
File Size
Date
Size
MultiRAE Sensor Firmware V 1.56.006 with signature
application/zip 264.62 KB
11/9/2023
264.62 KB
MultiRAE Application Firmware V 1.56.006 with signature
application/zip 1.26 MB
11/9/2023
1.26 MB
Technical Note
Name
Description
File Size
Date
Size
Technical Note 161 - Intrinsic Safety And Hazardous Locations
application/pdf 1.68 MB
7/15/2021
1.68 MB
Technical Note 165 - Combating Drift In Portable And Fixed PIDs
application/pdf 3.09 MB
7/15/2021
3.09 MB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
Technical Note 114 - Sensor Specifications and Cross-sensitivities
application/pdf 793.38 KB
7/15/2021
793.38 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
Technical Note 203 - Gas sequences for calibration and calibration check testing of the MultiRAE instrument family
application/pdf 2.58 MB
7/15/2021
2.58 MB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
application/pdf 976.3 KB
7/15/2021
976.3 KB
Technical Note 204 - Modes & Applications For The MultiRAE Benzene
application/pdf 224.39 KB
7/15/2021
224.39 KB
Technical Note 128 - Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 2.06 MB
7/15/2021
2.06 MB
Application Note 215 - Gas Detection In The Marine Industries
application/pdf 1.74 MB
7/15/2021
1.74 MB
Technical Note 144 - Handling LEL Sensor Poisons
application/pdf 1.85 MB
7/15/2021
1.85 MB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Technical Note 206 - Extending Life Of LEL Sensors In Field Conditions
application/pdf 88.11 KB
7/15/2021
88.11 KB
Technical Note 121 - CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 2.24 MB
7/15/2021
2.24 MB
Technical Note 169 - Theory And Operation Of NDIR Sensors - RU
application/pdf 862.26 KB
7/15/2021
862.26 KB
Technical Note 169 - Theory And Operation Of NDIR Sensors
application/pdf 1.76 MB
7/15/2021
1.76 MB
Technical Note 144 - Handling LEL Sensor Poisons - RU
application/pdf 404.34 KB
7/15/2021
404.34 KB
Technical Note 178 - Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.77 MB
7/15/2021
1.77 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
2/7/2022
820.7 KB
Technical Note 182 - Basics of Wireless Security
application/pdf 1.64 MB
7/15/2021
1.64 MB
TN-190: Monitor Remote Control Functions for MultiRAE
application/pdf 1.33 MB
7/15/2021
1.33 MB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
7/15/2021
620.4 KB
Technical Note 146 - Turning on UV Lamps in a PID Monitor - RU
application/pdf 384.5 KB
7/15/2021
384.5 KB
Technical Note 159 - Chemical Warfare Agent Measurements By PID
application/pdf 1.74 MB
7/15/2021
1.74 MB
Technical Note 174 - Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 1.53 MB
7/15/2021
1.53 MB
Technical Note 148 - Defining the Interval Between Calibration Checks - RU
application/pdf 417.43 KB
7/15/2021
417.43 KB
Technical Note 122 - Compliance of RAE Systems PIDs with EPA Method
application/pdf 2.27 MB
7/15/2021
2.27 MB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Techncail Note 141 - Monitor Remote Control Functions
application/pdf 2.21 MB
7/15/2021
2.21 MB
Technical Note 156 - Correction Factors for Combustible Gas (LEL) Sensors For EMEA according to EN61779
application/pdf 140.19 KB
7/15/2021
140.19 KB
Technical Note 146 - Turning on UV Lamps in a PID Monitor
application/pdf 384.5 KB
7/15/2021
384.5 KB
Technical Note 152 - Effects Of Operating Conditions On Oxygen Sensors
application/pdf 1.81 MB
7/15/2021
1.81 MB
Technical Note 148 - Defining the Interval Between Calibration Checks
application/pdf 1.86 MB
7/15/2021
1.86 MB
Certificate
Name
Description
File Size
Date
Size
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
MultiRAE 2 ATEX CE EU Declaration of Conformity
application/pdf 445.69 KB
11/15/2023
445.69 KB
MultiRAE Family ATEX CE EU Declaration of Conformity
application/pdf 420.78 KB
11/14/2023
420.78 KB
MultiRAE 2 ANEZEx IS Certificate of Conformity
application/pdf 852.55 KB
7/15/2021
852.55 KB
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
MultiRAE - CSA Certificate of Compliance
application/pdf 136.44 KB
1/7/2022
136.44 KB
MultiRAE 2 CSA Certificate of Compliance
application/pdf 101.68 KB
7/15/2021
101.68 KB
MultiRAE - EU Declaration of Conformity
application/pdf 212.27 KB
1/7/2022
212.27 KB
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
MultiRAE 2 IECEx Certificate of Conformity
application/pdf 322.78 KB
11/15/2023
322.78 KB
MultiRAE 2 Ex ATEX EC-Type Examination Certification
application/pdf 85.95 KB
7/15/2021
85.95 KB
MultiRAE 2 CSA Certificate of Compliance
application/pdf 45.13 KB
7/15/2021
45.13 KB
MultiRAE 2 IECEx Certificate of Conformity
application/pdf 656.88 KB
11/15/2023
656.88 KB
MultiRAE - Atex SIra EU Type Exam Certification
application/pdf 310.08 KB
1/7/2022
310.08 KB
Application Note
Name
Description
File Size
Date
Size
Nota de aplicac_n 203 PID como herramientas de respuesta a materiales peligrosos
application/pdf 2.55 MB
8/5/2022
2.55 MB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
Application Note 235 - Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 748.71 KB
8/4/2022
748.71 KB
Nota de applicaci_n 221 Uso de PID para evaluar el riesgo de exposici_n en entornos desconocidos
application/pdf 2.04 MB
8/5/2022
2.04 MB
Application Note 202 - The ABCs Of Gases In The Industry RU
application/pdf 452.66 KB
8/4/2022
452.66 KB
Nota de aplicaci_n AP-200 PID y entrada a tanques en las alas de los aviones
application/pdf 997.82 KB
8/5/2022
997.82 KB
Application Note 221 - Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 1.33 MB
8/4/2022
1.33 MB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 1.75 MB
8/4/2022
1.75 MB
Nota de aplicaci_n 219 Uso de PID para tomar decisiones relativas al 10% de LEL
application/pdf 2.08 MB
8/5/2022
2.08 MB
Application Note 217 - Confined Spaces And The Construction Industry
application/pdf 2.22 MB
8/4/2022
2.22 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
application/pdf 226.06 KB
7/15/2021
226.06 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
7/15/2021
1.07 MB
Application Note 220 - Using PIDs In Clan Lab Investigations
application/pdf 1.38 MB
8/10/2022
1.38 MB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2 RU
application/pdf 737.74 KB
8/4/2022
737.74 KB
Application Note 207 PIDs As Arson Investigation Tools
application/pdf 857.71 KB
7/15/2021
857.71 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 200: Photoionizatrion Detectors (PIDS) and Aircraft Wing Entry
application/pdf 892.2 KB
8/4/2021
892.2 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 236 - Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 904.28 KB
8/4/2022
904.28 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
7/15/2021
901.23 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
application/pdf 1 MB
7/15/2021
1 MB
Application Note 219 - Using PIDs For 10% Of LEL Decisions
application/pdf 1.84 MB
8/4/2022
1.84 MB
Application 202: The ABC®s Of Gases In The Industry
application/pdf 843.47 KB
7/27/2021
843.47 KB
Nota de aplicaci_n 216 Uso de PID en ataques terroristas con agentes qu_micos
application/pdf 2.02 MB
8/5/2022
2.02 MB
Others
Name
Description
File Size
Date
Size
Product Safety Advisory
application/pdf 118.18 KB
7/15/2021
118.18 KB
Other
Name
Description
File Size
Date
Size
RAESep Tebe Warning Letter
application/pdf 19.22 KB
7/15/2021
19.22 KB
Name
Description
File Size
Date
Size
Nota de aplicac_n 203 PID como herramientas de respuesta a materiales peligrosos
application/pdf 2.55 MB
8/5/2022
2.55 MB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
Technical Note 161 - Intrinsic Safety And Hazardous Locations
application/pdf 1.68 MB
7/15/2021
1.68 MB
Technical Note 165 - Combating Drift In Portable And Fixed PIDs
application/pdf 3.09 MB
7/15/2021
3.09 MB
Application Note 203: PIDs As HazMat Response Tools
application/pdf 1.26 MB
7/15/2021
1.26 MB
MultiRAE 2 ATEX CE EU Declaration of Conformity
application/pdf 445.69 KB
11/15/2023
445.69 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
Technical Note 114 - Sensor Specifications and Cross-sensitivities
application/pdf 793.38 KB
7/15/2021
793.38 KB
Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 814.89 KB
7/15/2021
814.89 KB
MultiRAE User Manual - UK
application/pdf 13.84 MB
5/10/2024
13.84 MB
Technical Note 203 - Gas sequences for calibration and calibration check testing of the MultiRAE instrument family
application/pdf 2.58 MB
7/15/2021
2.58 MB
Application Note 235 - Measurement Of PGMEA Using Photoionization Detectors_12-11
application/pdf 748.71 KB
8/4/2022
748.71 KB
Nota de applicaci_n 221 Uso de PID para evaluar el riesgo de exposici_n en entornos desconocidos
application/pdf 2.04 MB
8/5/2022
2.04 MB
Application Note 202 - The ABCs Of Gases In The Industry RU
application/pdf 452.66 KB
8/4/2022
452.66 KB
MultiRAE User Manual - FR
application/pdf 13.77 MB
5/7/2024
13.77 MB
MultiRAE User Manual - ES
application/pdf 13.74 MB
5/7/2024
13.74 MB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
application/pdf 976.3 KB
7/15/2021
976.3 KB
RAESep Tebe Warning Letter
application/pdf 19.22 KB
7/15/2021
19.22 KB
Technical Note 204 - Modes & Applications For The MultiRAE Benzene
application/pdf 224.39 KB
7/15/2021
224.39 KB
MultiRAE Family ATEX CE EU Declaration of Conformity
application/pdf 420.78 KB
11/14/2023
420.78 KB
MultiRAE User's Guide - NL
application/pdf 4.26 MB
7/15/2021
4.26 MB
MultiRAE User Manual - DE
application/pdf 13.71 MB
5/7/2024
13.71 MB
MultiRAE User Manual - PT
application/pdf 13.72 MB
5/7/2024
13.72 MB
Nota de aplicaci_n AP-200 PID y entrada a tanques en las alas de los aviones
application/pdf 997.82 KB
8/5/2022
997.82 KB
Application Note 221 - Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 1.33 MB
8/4/2022
1.33 MB
MultiRAE 2 ANEZEx IS Certificate of Conformity
application/pdf 852.55 KB
7/15/2021
852.55 KB
Application Note 211 - PIDs For Continuous Monitoring Of VOCs
application/pdf 1.75 MB
8/4/2022
1.75 MB
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
MultiRAE Sensor Firmware V 1.56.006 with signature
application/zip 264.62 KB
11/9/2023
264.62 KB
MultiRAE Application Firmware V 1.56.006 with signature
application/zip 1.26 MB
11/9/2023
1.26 MB
Nota de aplicaci_n 219 Uso de PID para tomar decisiones relativas al 10% de LEL
application/pdf 2.08 MB
8/5/2022
2.08 MB
Application Note 217 - Confined Spaces And The Construction Industry
application/pdf 2.22 MB
8/4/2022
2.22 MB
Technical Note 128 - Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 2.06 MB
7/15/2021
2.06 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
Product Safety Advisory
application/pdf 118.18 KB
7/15/2021
118.18 KB
Application Note 215 - Gas Detection In The Marine Industries
application/pdf 1.74 MB
7/15/2021
1.74 MB
Technical Note 144 - Handling LEL Sensor Poisons
application/pdf 1.85 MB
7/15/2021
1.85 MB
TN-204 Modes & Applications For The MultiRAE Benzene Application Note
application/pdf 226.06 KB
7/15/2021
226.06 KB
Application Note 216: Using PIDs In Terrorist Chemical Attacks
application/pdf 1.07 MB
7/15/2021
1.07 MB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
MultiRAE - CSA Certificate of Compliance
application/pdf 136.44 KB
1/7/2022
136.44 KB
Application Note 220 - Using PIDs In Clan Lab Investigations
application/pdf 1.38 MB
8/10/2022
1.38 MB
Technical Note 206 - Extending Life Of LEL Sensors In Field Conditions
application/pdf 88.11 KB
7/15/2021
88.11 KB
Technical Note 121 - CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 2.24 MB
7/15/2021
2.24 MB
MultiRAE 2 CSA Certificate of Compliance
application/pdf 101.68 KB
7/15/2021
101.68 KB
Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2 RU
application/pdf 737.74 KB
8/4/2022
737.74 KB
MultiRAE - EU Declaration of Conformity
application/pdf 212.27 KB
1/7/2022
212.27 KB
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
Technical Note 169 - Theory And Operation Of NDIR Sensors - RU
application/pdf 862.26 KB
7/15/2021
862.26 KB
Technical Note 169 - Theory And Operation Of NDIR Sensors
application/pdf 1.76 MB
7/15/2021
1.76 MB
Application Note 207 PIDs As Arson Investigation Tools
application/pdf 857.71 KB
7/15/2021
857.71 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Technical Note 144 - Handling LEL Sensor Poisons - RU
application/pdf 404.34 KB
7/15/2021
404.34 KB
Application Note 200: Photoionizatrion Detectors (PIDS) and Aircraft Wing Entry
application/pdf 892.2 KB
8/4/2021
892.2 KB
Technical Note 178 - Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.77 MB
7/15/2021
1.77 MB
MultiRAE User Manual - EN
application/pdf 13.7 MB
5/2/2024
13.7 MB
MultiRAE User Manual - IT
application/pdf 13.73 MB
5/8/2024
13.73 MB
MultiRAE User Manual - KO
application/pdf 14.01 MB
5/8/2024
14.01 MB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
2/7/2022
820.7 KB
Technical Note 182 - Basics of Wireless Security
application/pdf 1.64 MB
7/15/2021
1.64 MB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
MultiRAE Data Sheet
application/pdf 124.22 KB
7/15/2021
124.22 KB
MultiRAE 2 IECEx Certificate of Conformity
application/pdf 322.78 KB
11/15/2023
322.78 KB
TN-190: Monitor Remote Control Functions for MultiRAE
application/pdf 1.33 MB
7/15/2021
1.33 MB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
7/15/2021
620.4 KB
Technical Note 146 - Turning on UV Lamps in a PID Monitor - RU
application/pdf 384.5 KB
7/15/2021
384.5 KB
MultiRAE User Guide
application/pdf 8.12 MB
7/15/2021
8.12 MB
MultiRAE (Pumped Models) User's Guide - EN
application/pdf 898.78 KB
11/15/2023
898.78 KB
MultiRAE (Diffusion) Quick Reference Guide
application/pdf 595.58 KB
12/13/2023
595.58 KB
Application Note 236 - Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 904.28 KB
8/4/2022
904.28 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
7/15/2021
901.23 KB
MultiRAE 2 Ex ATEX EC-Type Examination Certification
application/pdf 85.95 KB
7/15/2021
85.95 KB
MultiRAE 2 CSA Certificate of Compliance
application/pdf 45.13 KB
7/15/2021
45.13 KB
Technical Note 159 - Chemical Warfare Agent Measurements By PID
application/pdf 1.74 MB
7/15/2021
1.74 MB
Technical Note 174 - Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
application/pdf 1.53 MB
7/15/2021
1.53 MB
MultiRAE 2 IECEx Certificate of Conformity
application/pdf 656.88 KB
11/15/2023
656.88 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
application/pdf 1 MB
7/15/2021
1 MB
MultiRAE User's Guide - RU
application/pdf 5.05 MB
7/15/2021
5.05 MB
Technical Note 148 - Defining the Interval Between Calibration Checks - RU
application/pdf 417.43 KB
7/15/2021
417.43 KB
Application Note 219 - Using PIDs For 10% Of LEL Decisions
application/pdf 1.84 MB
8/4/2022
1.84 MB
Technical Note 122 - Compliance of RAE Systems PIDs with EPA Method
application/pdf 2.27 MB
7/15/2021
2.27 MB
MultiRAE - Atex SIra EU Type Exam Certification
application/pdf 310.08 KB
1/7/2022
310.08 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
MultiRAE User Manual - JP
application/pdf 14.13 MB
5/8/2024
14.13 MB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Application 202: The ABC®s Of Gases In The Industry
application/pdf 843.47 KB
7/27/2021
843.47 KB
Techncail Note 141 - Monitor Remote Control Functions
application/pdf 2.21 MB
7/15/2021
2.21 MB
Nota de aplicaci_n 216 Uso de PID en ataques terroristas con agentes qu_micos
application/pdf 2.02 MB
8/5/2022
2.02 MB
Technical Note 156 - Correction Factors for Combustible Gas (LEL) Sensors For EMEA according to EN61779
application/pdf 140.19 KB
7/15/2021
140.19 KB
Technical Note 146 - Turning on UV Lamps in a PID Monitor
application/pdf 384.5 KB
7/15/2021
384.5 KB
Technical Note 152 - Effects Of Operating Conditions On Oxygen Sensors
application/pdf 1.81 MB
7/15/2021
1.81 MB
Technical Note 148 - Defining the Interval Between Calibration Checks
application/pdf 1.86 MB
7/15/2021
1.86 MB
Name
Date
Size
Showing 1 to 10 of 233 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
008-3009-000
KIT,PGM-50,EARPHONE WITH ADAPTER
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
008-3009-000
KIT,PGM-50,EARPHONE WITH ADAPTER
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
008-3024-000
External PID zeroing filter
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
008-3024-000
External PID zeroing filter
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
020-3603-000
PUMP ASSMBLY,QRAE II PUMP VERSION
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
020-3603-000
PUMP ASSMBLY,QRAE II PUMP VERSION
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
023-2722-000
FILTER FIXER,3G-PID SENSOR MODULE
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
023-2722-000
FILTER FIXER,3G-PID SENSOR MODULE
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
023-3012-000
6 flexible probe(Requires M01-3224-000 to be used with MultiRAE)
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
023-3012-000
6 flexible probe(Requires M01-3224-000 to be used with MultiRAE)
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
110-11P0.5
110SERIES SLIMLINE REGULATOR-0.5LPM CFL
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
110-11P0.5
110SERIES SLIMLINE REGULATOR-0.5LPM CFL
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
300-0016-015
BUZZER,4.0KHZ +-0.25KHZ,30VP-PMAX
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
300-0016-015
BUZZER,4.0KHZ +-0.25KHZ,30VP-PMAX
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
330-0012
NANUK NANO SERIES 330 ULTRA RESISTANT PO
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
330-0012
NANUK NANO SERIES 330 ULTRA RESISTANT PO
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
410-0036-000
Power cord (US Plug)
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
410-0036-000
Power cord (US Plug)
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
430-0394-000
SCREW,M3X10,PAN,PHIL,SS,NC,GB818-85
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
430-0394-000
SCREW,M3X10,PAN,PHIL,SS,NC,GB818-85
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-front-hires
Feedback