Fixed Flame Detectors
FS24X Plus
Triple IR Flame Detector
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
- Reliable Detection
- Fast response to a wide range of hydrocarbon and hydrogen fires even in low visibility conditions
- Advanced diagnostics including window clarity to maintain site protection Easy to Use
- Sunshade and standard or marine mounting bracket included for quickly and easily positioning the detector in an optimal location.
- Powerful FlameManager software replaces legacy dip switches for detector configuration and provides simplified diagnostics and post event FirePics™.
- High Visibility, Multi Color LED HALO ring provides clear indication of device status from up to 50ft (15m) away, even in bright outdoor environments
- Long-range, wide-angle sensors detect fires at 200ft (60m) for 1ft2 (0.1m2) n-Heptane
- Multiple outputs including 4-20mA, Relays, HART®, and Modbus communication all standard
- Responds to a wide range of hydrocarbon fires such as n-Heptane, Methane, Butane, Propane, Ethanol, Methanol, Diesel, Kerosene, JP-4, and IPA as well as Hydrogen
- Speed of response typically 5 seconds
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Brand
- Brand
- Honeywell
Dimension & Weight
- Weight range
- Aluminum: 1.7 kg (3.7 lbs), Stainless Steel: 3.4 kg (7.4 lbs)
Range
- Humidity Range
- 0-99%
- 0–99% relative humidity
Analog
- Analog Output Signal Type
- 4-20mA standard
- Number of Analog Outputs
- 1
Certifications
- Certifications - Other
- IEC61508 SIL 2 Certified by TUV Sud
- Maritime Type approved to ABS, Lloyds, BV, DNV
- Certifications - Performance
- EN54-10: Class1 (Medium, High, Very High Sensitivities), Class 2 (Low Sensitivity)
- FM3260
- Certifications - Hazloc
- ATEX: II 2 G Ex db IIC T5 Gb; II 2 D Ex tb IIIC T135° C Db IP66/67;
- CCC - Pending
- CUTR - Pending
- IECEx: Ex db IIC T5 Gb; Ex tb IIIC T135° C Db IP66/67;
- INMETRO
- cFMus: Class I, Div 1, Grps A,B,C,D; Class II/III, Div 1, Grps E,F,G NEMA 4X
Connector
- Connector Type
- 2 x M25 or 2 x ¾” NPT Entries
Datalogging
- Datalogging
- 5000 events and ten 30-second FirePics™
Features & Benefits
- Features & Benefits
- Calibration free
- Easy installation and commissioning
- Robust false alarm avoidance
- Simple maintenance
- Superior performance in adverse weather conditions (through smoke, rain, mist and fog)
- Features
- High-visibility halo light ring
- Modbus, HART®, 4-20 mA, Relays Standard
- Mounting bracket and sunshade included
- Multiple marine certifications
- Proved triple IR sensor technology
Material
- Material
- 316 Stainless Steel
- Low Copper Aluminum with Marine Grade Paint
Relay
- Relay Included
- Yes
- Relay Rated Load
- 2A at 32 VDC
- Relay Output Configuration
- Alarm, Fault, and Auxiliary
- Relay Activation Settings
- Single Pole Double Throw (SPDT)
Sensor
- Sensing Method
- Triple IR
Voltage & Current
- Operating Current
- 1.8 Watts (Nominal)
- 12 Watts (max) = with heater ON 100% duty cycle.
- 2.4 Watts (Alarm)
Additional Specifications
- Visual Indicators
- LED halo light ring - Green, Yellow, Red
- Response time
- Typically, 5 Seconds and a maximum of 10 Seconds
- NEMA Rating
- Type 4X
- Replacement Parts
- FS24XP-PUCK
- Number of Relay Outputs
- 3
- Ingress Protection
- IP66/67
Brand
- Brand
- Honeywell
Dimension & Weight
- Weight range
- Aluminum: 1.7 kg (3.7 lbs), Stainless Steel: 3.4 kg (7.4 lbs)
Range
- Humidity Range
- 0-99%
- 0–99% relative humidity
Analog
- Analog Output Signal Type
- 4-20mA standard
- Number of Analog Outputs
- 1
Certifications
- Certifications - Other
- IEC61508 SIL 2 Certified by TUV Sud
- Maritime Type approved to ABS, Lloyds, BV, DNV
- Certifications - Performance
- EN54-10: Class1 (Medium, High, Very High Sensitivities), Class 2 (Low Sensitivity)
- FM3260
- Certifications - Hazloc
- ATEX: II 2 G Ex db IIC T5 Gb; II 2 D Ex tb IIIC T135° C Db IP66/67;
- CCC - Pending
- CUTR - Pending
- IECEx: Ex db IIC T5 Gb; Ex tb IIIC T135° C Db IP66/67;
- INMETRO
- cFMus: Class I, Div 1, Grps A,B,C,D; Class II/III, Div 1, Grps E,F,G NEMA 4X
Connector
- Connector Type
- 2 x M25 or 2 x ¾” NPT Entries
Datalogging
- Datalogging
- 5000 events and ten 30-second FirePics™
Features & Benefits
- Features & Benefits
- Calibration free
- Easy installation and commissioning
- Robust false alarm avoidance
- Simple maintenance
- Superior performance in adverse weather conditions (through smoke, rain, mist and fog)
- Features
- High-visibility halo light ring
- Modbus, HART®, 4-20 mA, Relays Standard
- Mounting bracket and sunshade included
- Multiple marine certifications
- Proved triple IR sensor technology
Material
- Material
- 316 Stainless Steel
- Low Copper Aluminum with Marine Grade Paint
Relay
- Relay Included
- Yes
- Relay Rated Load
- 2A at 32 VDC
- Relay Output Configuration
- Alarm, Fault, and Auxiliary
- Relay Activation Settings
- Single Pole Double Throw (SPDT)
Sensor
- Sensing Method
- Triple IR
Voltage & Current
- Operating Current
- 1.8 Watts (Nominal)
- 12 Watts (max) = with heater ON 100% duty cycle.
- 2.4 Watts (Alarm)
Additional Specifications
- Visual Indicators
- LED halo light ring - Green, Yellow, Red
- Response time
- Typically, 5 Seconds and a maximum of 10 Seconds
- NEMA Rating
- Type 4X
- Replacement Parts
- FS24XP-PUCK
- Number of Relay Outputs
- 3
- Ingress Protection
- IP66/67
- Brand : Honeywell
- Weight range : Aluminum: 1.7 kg (3.7 lbs), Stainless Steel: 3.4 kg (7.4 lbs)
- Humidity Range : 0-99%|0–99% relative humidity
- Analog Output Signal Type : 4-20mA standard
- Number of Analog Outputs : 1
- Certifications - Other : IEC61508 SIL 2 Certified by TUV Sud|Maritime Type approved to ABS, Lloyds, BV, DNV
- Certifications - Performance : EN54-10: Class1 (Medium, High, Very High Sensitivities), Class 2 (Low Sensitivity)|FM3260
- Certifications - Hazloc : ATEX: II 2 G Ex db IIC T5 Gb; II 2 D Ex tb IIIC T135° C Db IP66/67;|CCC - Pending|CUTR - Pending|IECEx: Ex db IIC T5 Gb; Ex tb IIIC T135° C Db IP66/67;|INMETRO|cFMus: Class I, Div 1, Grps A,B,C,D; Class II/III, Div 1, Grps E,F,G NEMA 4X
- Connector Type : 2 x M25 or 2 x ¾” NPT Entries
- Datalogging : 5000 events and ten 30-second FirePics™
- Features & Benefits : Calibration free|Easy installation and commissioning|Robust false alarm avoidance|Simple maintenance|Superior performance in adverse weather conditions (through smoke, rain, mist and fog)
- Features : High-visibility halo light ring|Modbus, HART®, 4-20 mA, Relays Standard|Mounting bracket and sunshade included|Multiple marine certifications|Proved triple IR sensor technology
- Material : 316 Stainless Steel|Low Copper Aluminum with Marine Grade Paint
- Relay Included : Yes
- Relay Rated Load : 2A at 32 VDC
- Relay Output Configuration : Alarm, Fault, and Auxiliary
- Relay Activation Settings : Single Pole Double Throw (SPDT)
- Sensing Method : Triple IR
- Operating Current : 1.8 Watts (Nominal)|12 Watts (max) = with heater ON 100% duty cycle.|2.4 Watts (Alarm)
- Visual Indicators : LED halo light ring - Green, Yellow, Red
- Response time : Typically, 5 Seconds and a maximum of 10 Seconds
- NEMA Rating : Type 4X
- Replacement Parts : FS24XP-PUCK
- Number of Relay Outputs : 3
- Ingress Protection : IP66/67
Data Sheet
Manuals and Guides
Software
Brochure
Certificate
Please sign in to view part numbers available for purchase based on your account Sign In