Technical Specifications
- Accuracy
- ± 5% of Measuring Value
- Position Sensitivity
- None
- Long Term Sensitivity Drift
- < 2% per Months
- Flow Rate
- 200 ml/min when Using Recommended Gassing Hood
- Connection
- PCB Pins
- Solder Tags
Overview
- Warranty
- 5 Years
- Brand
- Honeywell
- Honeywell Citytech
Operating Characteristics
- Storage Temperature
- 0 to 20°C
- Operating Humidity Range
- 15 to 90% RH (Non-Condensing)
Standards & Certifications
- Standards & Certifications
- ANSI/ISA 92.00.01
- AS/NZS 4641
- BS EN 45544-1
Features
- Series Name
- 5
- Features & Benefits
- Digital Interface and Traceability
- Electrical Connection via PCB Pins or Solder Tags
- End-Of-Life Indication
- Fast Response and Recovery Time
- Fault Indication
- Incorporates Scavenging Electrode for Removal of by-Products
- Interchangeable
- OEM Lock
- Pre-Calibrated
- Predictive Calibration
- Superior Long-Term Performance at Temperature and Humidity Extremes
Material Specifications
- Outer Body Material
- Modified PPO
- O-Ring Material
- FKM60 ± 5 Shore A
- Contact Material
- Gold Plated
- Body Material
- Modified PPO
Others
- Response Time
- < 20 Seconds
- < 30 Seconds
- < 35 Seconds
- < 40 Seconds
- < 60 Seconds
- Recommended Load Resistor
- 10 Ohm
- 10 Ohm
- 100 Ohm
- 33 Ohm
- Operating Principle
- 3-Electrode Electrochemical
- 4-Electrode Electrochemical
- 4-Electrode Electrochemical
- Electrochemical
- Industry
- Energy
- Gases Detected
- Nitric Oxide (NO)
- Nitrogen Dioxide (NO2)
- Sulfur Dioxide (SO2)
- Expected Operating Life
- 2 Years
- 3 Years
- 5 Years
Technical Specifications
- Accuracy
- ± 5% of Measuring Value
- Position Sensitivity
- None
- Long Term Sensitivity Drift
- < 2% per Months
- Flow Rate
- 200 ml/min when Using Recommended Gassing Hood
- Connection
- PCB Pins
- Solder Tags
Overview
- Warranty
- 5 Years
- Brand
- Honeywell
- Honeywell Citytech
Operating Characteristics
- Storage Temperature
- 0 to 20°C
- Operating Humidity Range
- 15 to 90% RH (Non-Condensing)
Standards & Certifications
- Standards & Certifications
- ANSI/ISA 92.00.01
- AS/NZS 4641
- BS EN 45544-1
Features
- Series Name
- 5
- Features & Benefits
- Digital Interface and Traceability
- Electrical Connection via PCB Pins or Solder Tags
- End-Of-Life Indication
- Fast Response and Recovery Time
- Fault Indication
- Incorporates Scavenging Electrode for Removal of by-Products
- Interchangeable
- OEM Lock
- Pre-Calibrated
- Predictive Calibration
- Superior Long-Term Performance at Temperature and Humidity Extremes
Material Specifications
- Outer Body Material
- Modified PPO
- O-Ring Material
- FKM60 ± 5 Shore A
- Contact Material
- Gold Plated
- Body Material
- Modified PPO
Others
- Response Time
- < 20 Seconds
- < 30 Seconds
- < 35 Seconds
- < 40 Seconds
- < 60 Seconds
- Recommended Load Resistor
- 10 Ohm
- 10 Ohm
- 100 Ohm
- 33 Ohm
- Operating Principle
- 3-Electrode Electrochemical
- 4-Electrode Electrochemical
- 4-Electrode Electrochemical
- Electrochemical
- Industry
- Energy
- Gases Detected
- Nitric Oxide (NO)
- Nitrogen Dioxide (NO2)
- Sulfur Dioxide (SO2)
- Expected Operating Life
- 2 Years
- 3 Years
- 5 Years
- Accuracy : ± 5% of Measuring Value
- Warranty : 5 Years
- Storage Temperature : 0 to 20°C
- Standards & Certifications : ANSI/ISA 92.00.01|AS/NZS 4641|BS EN 45544-1
- Series Name : 5
- Response Time : < 20 Seconds|< 30 Seconds|< 35 Seconds|< 40 Seconds|< 60 Seconds
- Recommended Load Resistor : 10 Ohm|10 Ohm|100 Ohm|33 Ohm
- Position Sensitivity : None
- Outer Body Material : Modified PPO
- Operating Principle : 3-Electrode Electrochemical|4-Electrode Electrochemical|4-Electrode Electrochemical|Electrochemical
- Operating Humidity Range : 15 to 90% RH (Non-Condensing)
- O-Ring Material : FKM60 ± 5 Shore A
- Long Term Sensitivity Drift : < 2% per Months
- Industry : Energy
- Gases Detected : Nitric Oxide (NO)|Nitrogen Dioxide (NO2)|Sulfur Dioxide (SO2)
- Flow Rate : 200 ml/min when Using Recommended Gassing Hood
- Features & Benefits : Digital Interface and Traceability|Electrical Connection via PCB Pins or Solder Tags|End-Of-Life Indication|Fast Response and Recovery Time|Fault Indication|Incorporates Scavenging Electrode for Removal of by-Products|Interchangeable|OEM Lock|Pre-Calibrated|Predictive Calibration|Superior Long-Term Performance at Temperature and Humidity Extremes
- Expected Operating Life : 2 Years|3 Years|5 Years
- Contact Material : Gold Plated
- Connection : PCB Pins|Solder Tags
- Brand : Honeywell|Honeywell Citytech
- Body Material : Modified PPO
Please sign in to access more documents.
Once signed in, you may be able to access additional documents for your account.
Data Sheet
Manuals and Guides
CAD Model
Regulatory Information
Brochure
Technical Note
Application Note
Please sign in to view part numbers available for purchase based on your account Sign In