/content/sps/au/en/search-results.html
    Important Information: Now Live Introducing the new myAutomation experience! For site support, contact myAutomation@honeywell.com. Thank you for choosing Honeywell! Click here to get started.
    false
    false
    false

    Multi-Gas

    QRAE 3

    Versatile Compact wireless monitor for up to four gases

    Overview

    QRAE 3 is a versatile, rugged, one- to four-sensor pumped or diffusion gas monitor that provides continuous exposure monitoring of oxygen (O2), combustibles, and toxic gases, including hydrogen sulfide (H2S), carbon monoxide (CO), sulfur dioxide (SO2) and hydrogen cyanide (HCN) for workers and responders in hazardous environments.

    The QRAE 3’s wireless communications capability enables access to real-time instrument readings and alarm status (including man-down alarm) from any location for better visibility and faster response. Real-time hazard readings can also be communicated to the ProRAE Guardian Safety System and the EchoView Host Mini-Controller Closed-Loop Wireless System for safety-enhancing wireless monitoring.

    Features and Benefits:

    • Real-time gas detector readings and alarm status enabled by state of the art wireless technology
    • Unmistakable five-way local and remote wireless notification of alarm conditions
    • Intuitive simple-to-operate two-button user interface
    • Strong, protective, concussion-proof design
    • IP-65/67 water- and dust-resistant case

    Application:

    • CBRNE
    • Clandestine Labs
    • Confined Space Entry
    • Emergency Response
    • Environmental Cleanups/ Remediation
    • Exploration
    • Fire Overhaul
    • Leak Detection
    • Plant Shutdown & Turn-Around
    • Residential Calls
    • Urban Search & Rescue
    • Worker Exposure
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Brand

    • Brand
      • RAE

    Category

    • Sub-Category
      • Multi-Gas

    Dimension & Weight

    • Instrument Size
      • 5.7 "H x 3.2 "W x 1.7" D (145 mm x 82 mm x 42mm)

    Range

    • Sensor Range
      • O2 (0-30%vol), LEL (0-100% LEL), CO (0-500ppm), H2S (0-100ppm), SO2 (0-20ppm), HCN (0-50ppm), NH3 (0-100ppm), PH3 (0-20ppm), CL2 (0-50ppm), NO2 (0-50ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 8-14 hours

    Certifications

    • Standards & Certifications
      • US and Canada: classified for use in Class I

    Datalogging

    • Datalogging
      • Continuous datalogging (3 months for 4 sensors at 1-minute intervals,

    Features & Benefits

    • Features & Benefits
      • Available in Diffusion

    Options

    • User Options
      • Alarms: latching, non latching, or manual override

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • 2-year warranty on device

    Wireless

    • Wireless Technology
      • MESH

    Additional Specifications

    • Gas Type
      • O2, LEL, CO, H2S, SO2, HCN, NH3, PH3, CL2, NO2
    • Ingress Protection
      • IP65

    Others

    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 14.5 ounce av
      • 410 gram
    • Maximum Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius

    Brand

    • Brand
      • RAE

    Category

    • Sub-Category
      • Multi-Gas

    Dimension & Weight

    • Instrument Size
      • 5.7 "H x 3.2 "W x 1.7" D (145 mm x 82 mm x 42mm)

    Range

    • Sensor Range
      • O2 (0-30%vol), LEL (0-100% LEL), CO (0-500ppm), H2S (0-100ppm), SO2 (0-20ppm), HCN (0-50ppm), NH3 (0-100ppm), PH3 (0-20ppm), CL2 (0-50ppm), NO2 (0-50ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 8-14 hours

    Certifications

    • Standards & Certifications
      • US and Canada: classified for use in Class I

    Datalogging

    • Datalogging
      • Continuous datalogging (3 months for 4 sensors at 1-minute intervals,

    Features & Benefits

    • Features & Benefits
      • Available in Diffusion

    Options

    • User Options
      • Alarms: latching, non latching, or manual override

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • 2-year warranty on device

    Wireless

    • Wireless Technology
      • MESH

    Additional Specifications

    • Gas Type
      • O2, LEL, CO, H2S, SO2, HCN, NH3, PH3, CL2, NO2
    • Ingress Protection
      • IP65

    Others

    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 14.5 ounce av
      • 410 gram
    • Maximum Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius
    • Brand : RAE
    • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
    • Weight : 14.5 ounce av|410 gram
    • Maximum Temperature : 122 degree Fahrenheit|50 degree Celsius
    • Sub-Category : Multi-Gas
    • Instrument Size : 5.7 "H x 3.2 "W x 1.7" D (145 mm x 82 mm x 42mm)
    • Sensor Range : O2 (0-30%vol), LEL (0-100% LEL), CO (0-500ppm), H2S (0-100ppm), SO2 (0-20ppm), HCN (0-50ppm), NH3 (0-100ppm), PH3 (0-20ppm), CL2 (0-50ppm), NO2 (0-50ppm)
    • Humidity Range : 0%-95% percent
    • Alarm Type : Audible, Visual, Vibrating
    • Battery Run Time : 8-14 hours
    • Standards & Certifications : US and Canada: classified for use in Class I
    • Datalogging : Continuous datalogging (3 months for 4 sensors at 1-minute intervals,
    • Features & Benefits : Available in Diffusion
    • User Options : Alarms: latching, non latching, or manual override
    • Sampling Pump Range : 100ft (30m) meter
    • Warranty : 2-year warranty on device
    • Wireless Technology : MESH
    • Gas Type : O2, LEL, CO, H2S, SO2, HCN, NH3, PH3, CL2, NO2
    • Ingress Protection : IP65
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    QRAE 3 Data Sheet
    application/pdf 119.31 KB
    7/15/2021
    119.31 KB
    QRAE 3 Data Sheet - NL
    application/pdf 120.19 KB
    7/15/2021
    120.19 KB
    QRAE 3 Data Sheet - FR
    application/pdf 121.95 KB
    7/15/2021
    121.95 KB
    QRAE 3 Data Sheet - DE
    application/pdf 122.32 KB
    7/15/2021
    122.32 KB
    QRAE 3 Data Sheet - PT
    application/pdf 122.29 KB
    7/15/2021
    122.29 KB
    QRAE 3 Data Sheet - RU
    application/pdf 205.15 KB
    7/15/2021
    205.15 KB
    QRAE 3 Data Sheet - ES
    application/pdf 120.95 KB
    7/15/2021
    120.95 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    QRAE 3 User Manual EN
    application/postscript 6.32 MB
    1/16/2024
    6.32 MB
    QRAE 3 Quick Start Guide
    application/pdf 848.86 KB
    7/15/2021
    848.86 KB
    Firmware
    Name
    Description
    File Size
    Date
    Size
    QRAE3 V2.18 with signature
    application/zip 481.01 KB
    10/27/2021
    481.01 KB
    QRAE3 V2.18 with signature
    application/zip 481.01 KB
    7/15/2021
    481.01 KB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/15/2021
    926.7 KB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Electrochemical Sensor Replacement & Maintenance Technical Note 151
    application/pdf 976.3 KB
    7/15/2021
    976.3 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 161 Intrinsic Safety And Hazardous Locations
    application/pdf 884.37 KB
    7/15/2021
    884.37 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    Technical Note 180 SPE (Solid Polymer Electrolyte) Oxygen Sensor
    application/pdf 915.76 KB
    7/15/2021
    915.76 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    Certificate
    Name
    Description
    File Size
    Date
    Size
    QRAE 3 INMETRO Certificate Of Conformity
    application/pdf 459.4 KB
    2/20/2024
    459.4 KB
    QRAE 3 Ingress Protection - IP 67 Test Certificate
    application/pdf 426.98 KB
    1/6/2022
    426.98 KB
    QRAE 3 IECEx Certificate of Conformity
    application/pdf 73.53 KB
    1/6/2022
    73.53 KB
    SIRA EC-Type Certificate
    application/pdf 68.54 KB
    1/6/2022
    68.54 KB
    QRAE 3 CSA Certificate of Compliance
    application/pdf 57.06 KB
    1/6/2022
    57.06 KB
    QRAE 3 Ingress Protection - IP 65 Test Certificate
    application/pdf 426.95 KB
    1/6/2022
    426.95 KB
    QRAE 3 EU Declaration of Conformity
    application/pdf 212.09 KB
    1/6/2022
    212.09 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
    application/pdf 941.33 KB
    8/4/2022
    941.33 KB
    Toxic Twins (HCN & CO) In Fire Overhaul
    application/pdf 828.25 KB
    7/15/2021
    828.25 KB
    Application Note 222: Carbon Monoxide & Natural Gas Detection For Fire Department Engine Companies
    application/pdf 1.17 MB
    7/15/2021
    1.17 MB
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces
    application/pdf 1 MB
    7/15/2021
    1 MB
    Application Note 217: Confined Spaces And The Construction Industry
    application/pdf 828.21 KB
    7/15/2021
    828.21 KB
    Name
    Description
    File Size
    Date
    Size
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/15/2021
    926.7 KB
    QRAE 3 INMETRO Certificate Of Conformity
    application/pdf 459.4 KB
    2/20/2024
    459.4 KB
    QRAE 3 User Manual EN
    application/postscript 6.32 MB
    1/16/2024
    6.32 MB
    QRAE 3 Ingress Protection - IP 67 Test Certificate
    application/pdf 426.98 KB
    1/6/2022
    426.98 KB
    QRAE 3 IECEx Certificate of Conformity
    application/pdf 73.53 KB
    1/6/2022
    73.53 KB
    SIRA EC-Type Certificate
    application/pdf 68.54 KB
    1/6/2022
    68.54 KB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    QRAE 3 Data Sheet
    application/pdf 119.31 KB
    7/15/2021
    119.31 KB
    QRAE 3 Data Sheet - NL
    application/pdf 120.19 KB
    7/15/2021
    120.19 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Electrochemical Sensor Replacement & Maintenance Technical Note 151
    application/pdf 976.3 KB
    7/15/2021
    976.3 KB
    QRAE 3 Data Sheet - FR
    application/pdf 121.95 KB
    7/15/2021
    121.95 KB
    QRAE 3 CSA Certificate of Compliance
    application/pdf 57.06 KB
    1/6/2022
    57.06 KB
    QRAE 3 Quick Start Guide
    application/pdf 848.86 KB
    7/15/2021
    848.86 KB
    QRAE 3 Data Sheet - DE
    application/pdf 122.32 KB
    7/15/2021
    122.32 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    QRAE3 V2.18 with signature
    application/zip 481.01 KB
    10/27/2021
    481.01 KB
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
    application/pdf 941.33 KB
    8/4/2022
    941.33 KB
    QRAE 3 Data Sheet - PT
    application/pdf 122.29 KB
    7/15/2021
    122.29 KB
    Toxic Twins (HCN & CO) In Fire Overhaul
    application/pdf 828.25 KB
    7/15/2021
    828.25 KB
    Application Note 222: Carbon Monoxide & Natural Gas Detection For Fire Department Engine Companies
    application/pdf 1.17 MB
    7/15/2021
    1.17 MB
    Technical Note 161 Intrinsic Safety And Hazardous Locations
    application/pdf 884.37 KB
    7/15/2021
    884.37 KB
    QRAE3 V2.18 with signature
    application/zip 481.01 KB
    7/15/2021
    481.01 KB
    QRAE 3 Ingress Protection - IP 65 Test Certificate
    application/pdf 426.95 KB
    1/6/2022
    426.95 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    QRAE 3 Data Sheet - RU
    application/pdf 205.15 KB
    7/15/2021
    205.15 KB
    QRAE 3 EU Declaration of Conformity
    application/pdf 212.09 KB
    1/6/2022
    212.09 KB
    Technical Note 180 SPE (Solid Polymer Electrolyte) Oxygen Sensor
    application/pdf 915.76 KB
    7/15/2021
    915.76 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces
    application/pdf 1 MB
    7/15/2021
    1 MB
    QRAE 3 Data Sheet - ES
    application/pdf 120.95 KB
    7/15/2021
    120.95 KB
    Application Note 217: Confined Spaces And The Construction Industry
    application/pdf 828.21 KB
    7/15/2021
    828.21 KB
    Name
    Description
    File Size
    Date
    Size
    QRAE 3 Data Sheet
    119.31 KB
    7/15/2021
    QRAE 3 Data Sheet - NL
    120.19 KB
    7/15/2021
    QRAE 3 Data Sheet - FR
    121.95 KB
    7/15/2021
    QRAE 3 Data Sheet - DE
    122.32 KB
    7/15/2021
    QRAE 3 Data Sheet - PT
    122.29 KB
    7/15/2021
    QRAE 3 Data Sheet - RU
    205.15 KB
    7/15/2021
    QRAE 3 Data Sheet - ES
    120.95 KB
    7/15/2021
    QRAE 3 User Manual EN
    6.32 MB
    1/16/2024
    QRAE 3 Quick Start Guide
    848.86 KB
    7/15/2021
    QRAE3 V2.18 with signature
    481.01 KB
    10/27/2021
    QRAE3 V2.18 with signature
    481.01 KB
    7/15/2021
    Lithium-Ion Batteries Technical Note 166
    926.7 KB
    7/15/2021
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    609.21 KB
    7/15/2021
    Technical Note 148 Defining The Interval Between Calibration Checks
    839.32 KB
    12/14/2022
    Electrochemical Sensor Replacement & Maintenance Technical Note 151
    976.3 KB
    7/15/2021
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Technical Note 161 Intrinsic Safety And Hazardous Locations
    884.37 KB
    7/15/2021
    Technical Note 144 Handling LEL Sensor Poisons
    802.28 KB
    8/3/2022
    Technical Note 180 SPE (Solid Polymer Electrolyte) Oxygen Sensor
    915.76 KB
    7/15/2021
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    795.02 KB
    7/15/2021
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    125.12 KB
    1/23/2024
    QRAE 3 INMETRO Certificate Of Conformity
    459.4 KB
    2/20/2024
    QRAE 3 Ingress Protection - IP 67 Test Certificate
    426.98 KB
    1/6/2022
    QRAE 3 IECEx Certificate of Conformity
    73.53 KB
    1/6/2022
    SIRA EC-Type Certificate
    68.54 KB
    1/6/2022
    QRAE 3 CSA Certificate of Compliance
    57.06 KB
    1/6/2022
    QRAE 3 Ingress Protection - IP 65 Test Certificate
    426.95 KB
    1/6/2022
    QRAE 3 EU Declaration of Conformity
    212.09 KB
    1/6/2022
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
    941.33 KB
    8/4/2022
    Toxic Twins (HCN & CO) In Fire Overhaul
    828.25 KB
    7/15/2021
    Application Note 222: Carbon Monoxide & Natural Gas Detection For Fire Department Engine Companies
    1.17 MB
    7/15/2021
    Application Note 206 Guide To Atmospheric Testing In Confined Spaces
    1 MB
    7/15/2021
    Application Note 217: Confined Spaces And The Construction Industry
    828.21 KB
    7/15/2021
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    D06J-0420-008
    RG3 S ATEXIECEx ,H2S,  HART Output
    https://s7d1.scene7.com/is/image/Honeywell65/QRAE3-Diffusion_front_clr-bkg
    D06J-0420-008
    RG3 S ATEXIECEx ,H2S,  HART Output
    https://s7d1.scene7.com/is/image/Honeywell65/QRAE3-Diffusion_front_clr-bkg
    M02-2043-000
    4-point chest harness for QRAE 3 holster case
    https://s7d1.scene7.com/is/image/Honeywell65/QRAE3-Diffusion_front_clr-bkg
    M02-2043-000
    4-point chest harness for QRAE 3 holster case
    https://s7d1.scene7.com/is/image/Honeywell65/QRAE3-Diffusion_front_clr-bkg
    M02-3005-000
    Travel charger
    https://s7d1.scene7.com/is/image/Honeywell65/QRAE3-Diffusion_front_clr-bkg
    M02-3005-000
    Travel charger
    https://s7d1.scene7.com/is/image/Honeywell65/QRAE3-Diffusion_front_clr-bkg