Overview
XCD_RFD_web_main

Your most flexible, practical choice for remote flammable gas monitoring in Class 1, Div 1 areas.

Product Overview:

Sensepoint XCD RFD (Remote Flammable Detector) has been specifically designed for use with remotely mounted flammable gas sensors. This configuration is ideal for applications where the sensor is required to be mounted remotely from the transmitter in areas where temperatures are well above ambient (up to 150°C/302°F), or that are difficult to access. The transmitter can be mounted at a suitable location away from this area where it is easy to access, view its display and interact with via the user interface.

Features & Benefits:

  • Accurate detection with fast response
  • Mount sensor up to 100 ft. from transmitter
  • Easy to read tri-color backlit display

Quick Specs:

  • Input voltage range: 16 to 32 VDC (24 VDC nominal)
  • Communication: RS485, MODBUS RTU
  • Mounting: Pole or wall

Fire and Gas Consultancy Services

Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Overview

  • Brand
    • Honeywell
    • Honeywell

Features

  • Sub-Category
    • Gas Detection Sensors & Transmitters
    • Gas Detection Sensors & Transmitters
  • Features & Benefits
    • Auto-Inhibit During Maintenance Prevents False Alarms
    • Compatible with Honeywell Analytics’ Proven Catalytic Bead Flammable Gas Sensors
    • Easy to Read Tri-Colour Backlit Display with Digits, Bar Graph and Icons
    • Fully Configurable via Non-Intrusive Magnetic Switches
    • Gas Sensors Use Long Life, Poison Resistant Beads as Standard, Reducing Ongoing Cost of Ownership
    • High Temperature Gas Sensors Have Thermally Matched Beads for Highest Accuracy and Stability Enabling Low Alarm Levels
    • Non-Intrusive, One-Man Operation Reduces Cost of Maintenance
    • Optional Sensepoint XCD plug-in sensor reduces maintenance time further
    • Reduced Spares and Stock Costs
    • Reduces Training Costs
    • Selectable Sink or Source 4 to 20 mA Output
    • Sensepoint XCD Common Transmitter Platform

Dimensions & Weight

  • Weight range
    • 316 Stainless Steel: 11 lbs
    • Aluminium Alloy LM25: 4.4 lbs

Technical Specifications

  • Humidity Range
    • Continuous: 20 to 90% RH (Non-Condensing)
    • Intermittent: 10 to 99% RH (Non-Condensing)
  • Relay Output Configuration
    • 3 x 5A @250 VAC
  • Mounting
    • Wall
  • Maximum Pressure
    • 110 kPa
  • Conduit Entries
    • (2) 3/4 in NPT
  • Communication
    • Modbus RTU
    • RS485

Operating Characteristics

  • Minimum Temperature
    • -40˚C
  • Storage Temperature
    • -25 to +65°C

Electrical Specifications

  • Operating Current
    • 4 to 20 mA
  • Electrical Connection
    • 15 x Screw Terminals with Wire Diameter 0.5 to 2.5 sq.mm (20 to 13 AWG)
  • Power Consumption
    • 5W @24 VDC
  • Operating Voltage
    • 16 to 32 VDC

Standards & Certifications

  • Ingress Protection
    • IP66

Applications & Compatibility

  • Application
    • Compatible with High Temperature Sensors for Use in and around Gas Turbine Enclosures and Solvent Based Printing and Coating Drying Ovens
    • Compliant with the Requirements of HSE Guidance Note PM84
    • Sensor can be Mounted up to 30m (100ft) from Transmitter
    • Standard Temperature Catalytic And Infrared Sensor Types Also Available
    • Transmitter can Be Mounted in Easy to Access Area Even if Sensor is in a Hard to Access or Restricted Access Area

Material Specifications

  • Enclosure Material
    • 316 Stainless Steel
    • Epoxy Painted Aluminium Alloy

Overview

  • Brand
    • Honeywell
    • Honeywell

Features

  • Sub-Category
    • Gas Detection Sensors & Transmitters
    • Gas Detection Sensors & Transmitters
  • Features & Benefits
    • Auto-Inhibit During Maintenance Prevents False Alarms
    • Compatible with Honeywell Analytics’ Proven Catalytic Bead Flammable Gas Sensors
    • Easy to Read Tri-Colour Backlit Display with Digits, Bar Graph and Icons
    • Fully Configurable via Non-Intrusive Magnetic Switches
    • Gas Sensors Use Long Life, Poison Resistant Beads as Standard, Reducing Ongoing Cost of Ownership
    • High Temperature Gas Sensors Have Thermally Matched Beads for Highest Accuracy and Stability Enabling Low Alarm Levels
    • Non-Intrusive, One-Man Operation Reduces Cost of Maintenance
    • Optional Sensepoint XCD plug-in sensor reduces maintenance time further
    • Reduced Spares and Stock Costs
    • Reduces Training Costs
    • Selectable Sink or Source 4 to 20 mA Output
    • Sensepoint XCD Common Transmitter Platform

Dimensions & Weight

  • Weight range
    • 316 Stainless Steel: 11 lbs
    • Aluminium Alloy LM25: 4.4 lbs

Technical Specifications

  • Humidity Range
    • Continuous: 20 to 90% RH (Non-Condensing)
    • Intermittent: 10 to 99% RH (Non-Condensing)
  • Relay Output Configuration
    • 3 x 5A @250 VAC
  • Mounting
    • Wall
  • Maximum Pressure
    • 110 kPa
  • Conduit Entries
    • (2) 3/4 in NPT
  • Communication
    • Modbus RTU
    • RS485

Operating Characteristics

  • Minimum Temperature
    • -40˚C
  • Storage Temperature
    • -25 to +65°C

Electrical Specifications

  • Operating Current
    • 4 to 20 mA
  • Electrical Connection
    • 15 x Screw Terminals with Wire Diameter 0.5 to 2.5 sq.mm (20 to 13 AWG)
  • Power Consumption
    • 5W @24 VDC
  • Operating Voltage
    • 16 to 32 VDC

Standards & Certifications

  • Ingress Protection
    • IP66

Applications & Compatibility

  • Application
    • Compatible with High Temperature Sensors for Use in and around Gas Turbine Enclosures and Solvent Based Printing and Coating Drying Ovens
    • Compliant with the Requirements of HSE Guidance Note PM84
    • Sensor can be Mounted up to 30m (100ft) from Transmitter
    • Standard Temperature Catalytic And Infrared Sensor Types Also Available
    • Transmitter can Be Mounted in Easy to Access Area Even if Sensor is in a Hard to Access or Restricted Access Area

Material Specifications

  • Enclosure Material
    • 316 Stainless Steel
    • Epoxy Painted Aluminium Alloy
  • Brand : Honeywell|Honeywell
  • Sub-Category : Gas Detection Sensors & Transmitters|Gas Detection Sensors & Transmitters
  • Weight range : 316 Stainless Steel: 11 lbs|Aluminium Alloy LM25: 4.4 lbs
  • Humidity Range : Continuous: 20 to 90% RH (Non-Condensing)|Intermittent: 10 to 99% RH (Non-Condensing)
  • Minimum Temperature : -40˚C
  • Features & Benefits : Auto-Inhibit During Maintenance Prevents False Alarms|Compatible with Honeywell Analytics’ Proven Catalytic Bead Flammable Gas Sensors|Easy to Read Tri-Colour Backlit Display with Digits, Bar Graph and Icons|Fully Configurable via Non-Intrusive Magnetic Switches|Gas Sensors Use Long Life, Poison Resistant Beads as Standard, Reducing Ongoing Cost of Ownership|High Temperature Gas Sensors Have Thermally Matched Beads for Highest Accuracy and Stability Enabling Low Alarm Levels|Non-Intrusive, One-Man Operation Reduces Cost of Maintenance|Optional Sensepoint XCD plug-in sensor reduces maintenance time further|Reduced Spares and Stock Costs|Reduces Training Costs|Selectable Sink or Source 4 to 20 mA Output|Sensepoint XCD Common Transmitter Platform
  • Relay Output Configuration : 3 x 5A @250 VAC
  • Operating Current : 4 to 20 mA
  • Mounting : Wall
  • Maximum Pressure : 110 kPa
  • Ingress Protection : IP66
  • Electrical Connection : 15 x Screw Terminals with Wire Diameter 0.5 to 2.5 sq.mm (20 to 13 AWG)
  • Application : Compatible with High Temperature Sensors for Use in and around Gas Turbine Enclosures and Solvent Based Printing and Coating Drying Ovens|Compliant with the Requirements of HSE Guidance Note PM84|Sensor can be Mounted up to 30m (100ft) from Transmitter|Standard Temperature Catalytic And Infrared Sensor Types Also Available|Transmitter can Be Mounted in Easy to Access Area Even if Sensor is in a Hard to Access or Restricted Access Area
  • Storage Temperature : -25 to +65°C
  • Power Consumption : 5W @24 VDC
  • Operating Voltage : 16 to 32 VDC
  • Enclosure Material : 316 Stainless Steel|Epoxy Painted Aluminium Alloy
  • Conduit Entries : (2) 3/4 in NPT
  • Communication : Modbus RTU|RS485
Data Sheet
Name
Description
File Size
Date
Size
Sensepoint XCD RFD - Data Sheet - English
application/pdf 2.11 MB
6/7/2023
2.11 MB
Manuals and Guides
Name
Description
File Size
Date
Size
Sensepoint XCD RFD Quick Start Guide
application/pdf 742.01 KB
7/15/2021
742.01 KB
Sensepoint XCD RFD User Manual
application/pdf 5.81 MB
7/15/2021
5.81 MB
Industrial Fixed Gas and Flame Detection Product Guide 2018
application/pdf 8.69 MB
3/3/2022
8.69 MB
Brochure
Name
Description
File Size
Date
Size
Sensepoint XCD RFD Brochure
application/pdf 513.4 KB
7/15/2021
513.4 KB
Technical Note
Name
Description
File Size
Date
Size
Sensepoint XCD RFD,Sensepoint XCD RTD Technical Note
application/pdf 331.52 KB
7/15/2021
331.52 KB
Sensepoint XCD RFD Specifications
application/pdf 256.52 KB
7/15/2021
256.52 KB
Certificate
Name
Description
File Size
Date
Size
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate IECEx BAS 08.0104X
application/pdf 358.33 KB
7/15/2021
358.33 KB
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate Baseefa08ATEX0222
application/pdf 357.73 KB
7/15/2021
357.73 KB
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate BAS 08.0072
application/pdf 356.28 KB
7/15/2021
356.28 KB
Sensepoint XCD RFD Certificate of Conformity 130006
application/pdf 427.16 KB
7/15/2021
427.16 KB
Sensepoint XCD RFD CSA Certificate of Compliance
application/pdf 89.42 KB
7/15/2021
89.42 KB
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate Baseefa08ATEX0316X
application/pdf 356.47 KB
7/15/2021
356.47 KB
Name
Description
File Size
Date
Size
Sensepoint XCD RFD Brochure
application/pdf 513.4 KB
7/15/2021
513.4 KB
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate IECEx BAS 08.0104X
application/pdf 358.33 KB
7/15/2021
358.33 KB
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate Baseefa08ATEX0222
application/pdf 357.73 KB
7/15/2021
357.73 KB
Sensepoint XCD RFD,Sensepoint XCD RTD Technical Note
application/pdf 331.52 KB
7/15/2021
331.52 KB
Sensepoint XCD RFD Quick Start Guide
application/pdf 742.01 KB
7/15/2021
742.01 KB
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate BAS 08.0072
application/pdf 356.28 KB
7/15/2021
356.28 KB
Sensepoint XCD RFD User Manual
application/pdf 5.81 MB
7/15/2021
5.81 MB
Sensepoint XCD RFD Certificate of Conformity 130006
application/pdf 427.16 KB
7/15/2021
427.16 KB
Industrial Fixed Gas and Flame Detection Product Guide 2018
application/pdf 8.69 MB
3/3/2022
8.69 MB
Sensepoint XCD RFD Specifications
application/pdf 256.52 KB
7/15/2021
256.52 KB
Sensepoint XCD RFD CSA Certificate of Compliance
application/pdf 89.42 KB
7/15/2021
89.42 KB
Sensepoint XCD RFD,Sensepoint XCD,Sensepoint XCD RTD Flameproof Certificate Baseefa08ATEX0316X
application/pdf 356.47 KB
7/15/2021
356.47 KB
Sensepoint XCD RFD - Data Sheet - English
application/pdf 2.11 MB
6/7/2023
2.11 MB
Showing 1 to 2 of 2 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
1283-1047
Adapter Assembly: Duct-Mount
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
1283-1047
Adapter Assembly: Duct-Mount
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
SPXCDALMRFD
XCD RFD Transmitter: 4 to 20 mA output: ATEXIECEx: 2 x M20 entries: 1 x M25 entry: painted LM25
https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-alerton-gas-sensor-primaryimage
SPXCDALMRFD
XCD RFD Transmitter: 4 to 20 mA output: ATEXIECEx: 2 x M20 entries: 1 x M25 entry: painted LM25
https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-alerton-gas-sensor-primaryimage
SPXCDASMRFD
ATEXIECEX AP APPROVED SP XCD RFD 316SS
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
SPXCDASMRFD
ATEXIECEX AP APPROVED SP XCD RFD 316SS
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
SPXCDULNPX
XCD Gas Detector, includes infrared propane sensor cartridge 0 to 100%LEL
https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-spxcdulnb1-gas-detector-primaryimage
SPXCDULNPX
XCD Gas Detector, includes infrared propane sensor cartridge 0 to 100%LEL
https://s7d1.scene7.com/is/image/Honeywell65/hbt-fire-spxcdulnb1-gas-detector-primaryimage
SPXCDULNRFD
XCD RFD Transmitter, 4 to 20 mA output, cCSAusINMETRO, 3 x 34 NPT entries, painted LM25
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
SPXCDULNRFD
XCD RFD Transmitter, 4 to 20 mA output, cCSAusINMETRO, 3 x 34 NPT entries, painted LM25
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
SPXCDULNRFDM
XCD RFD Transmitter: 4 to 20 mA and Modbus output: cCSAusINMETRO: 3 x 34' NPT entries: painted LM25
https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-alerton-gas-sensor-primaryimage
SPXCDULNRFDM
XCD RFD Transmitter: 4 to 20 mA and Modbus output: cCSAusINMETRO: 3 x 34' NPT entries: painted LM25
https://honeywell.scene7.com/is/image/Honeywell65/hbt-bms-alerton-gas-sensor-primaryimage
SPXCDUSNRFD
XCD RFD Transmitter, 4 to 20 mA output, cCSAusINMETRO, 3 x 34 NPT entries, painted 316SS
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
SPXCDUSNRFD
XCD RFD Transmitter, 4 to 20 mA output, cCSAusINMETRO, 3 x 34 NPT entries, painted 316SS
https://honeywell.scene7.com/is/image/Honeywell65/hbt-icon-parts-and-accessories-4-primaryimage
SPXCDUSNRFDM
XCD RFD Transmitter, 4 to 20 mA and Modbus output, cCSAusINMETRO, 3 x 34 NPT entries, painted 316SS
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
SPXCDUSNRFDM
XCD RFD Transmitter, 4 to 20 mA and Modbus output, cCSAusINMETRO, 3 x 34 NPT entries, painted 316SS
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
XCDRFDKIT
CALIBRATION KIT FOR XCD RFD
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
XCDRFDKIT
CALIBRATION KIT FOR XCD RFD
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
XCDRFDL
cCSAus approved SPXCD RFD Transmitter with LM25, 34“NPT Entry, aluminum, 705 sensor, and 3 wire junction box
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main
XCDRFDL
cCSAus approved SPXCD RFD Transmitter with LM25, 34“NPT Entry, aluminum, 705 sensor, and 3 wire junction box
https://s7d1.scene7.com/is/image/Honeywell65/XCD_RFD_web_main

Alternative Products

Feedback