Fixed Gas Detectors
Searchline Excel™ Edge
Open Path Infrared Gas Detector - Long Range
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
- Fast response to flammable hydrocarbon gas even in low visibility
- Advanced diagnostics including window clarity and alignment accuracy to enable maximum uptime
- Honeywell’s Fixed Platform Universal Mount and new alignment scope makes for easy installation
- Bluetooth® connectivity for simplified, non-intrusive set-up and maintenance.
- High Visibility, Multi Color LED HALO ring provides clear indication of device status
- Detection from 60 to 330 meters (196 to 1082 feet)
- Multiple outputs including 4-20mA, Relays, HART®, Modbus and Bluetooth® communication
- Responses to a wide range of hydrocarbon gases such as Methane, Ethane, Propane, Butane, Pentane, Hexane, Ethylene, and Propylene
- Speed of response (T90) less than 3 seconds
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Brand
- Brand
- Honeywell
Category
- Sub-Category
- Open Path Gas Detectors & Transmitters
Range
- Humidity Range
- 0–99 % RH Non-condensing
- Sensor Range
- 60 m to 330 m (196 to 1,082 ft)
Alarm
- Alarm Settings
- Recommended High Alarm - 3 LEL.m
- Recommended Low Alarm - 1 LEL.m
Analog
- Analog Output Signal Type
- 4-20mA standard
Certifications
- Standards
- EN 50270: (EMC)NEWLINEIEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EUNEWLINEIEC/EN/UL/CSA 61010 (Electrical Safety)NEWLINEFCC / ICNEWLINERoHS, China RoHS
Features & Benefits
- Features
- Bluetooth® enabled
Material
- Material
- 316L Stainless Steel
Relay
- Relay Output Configuration
- Relay 1 is Alarm Level 1, Relay 2 is Alarm Level 2, Relay 3 Indicates Faults
- Relay Activation Settings
- Single Pole Double Throw (SPDT)
- Relay Rated Load
- Max. 32 Vdc/ac, max. 2 A resistive load
Sensor
- Sensor Type
- Open Path Infrared
- Sensing Method
- Near Band Infrared
Wireless
- Wireless Technology
- Bluetooth® (range up to 20 m (66 ft)
Additional Specifications
- Ingress Protection
- IP66/67
- Gas Type
- Flammable Hydrocarbon
- Visual Indicators
- LEDs on the transmitter and a high visibility HALO light ring on the receiver
- Number of Relay Outputs
- 3
- Mounting
- Universal Mounting Bracket Included
- Maximum Pressure
- 105.5 kPa (1055 mBar, non-compensated) kilopascal
- NEMA Rating
- Type 4X, in accordance with NEMA 250
Others
- Weight
- Receiver 6.1 kg (13.4 lbs), Transmitter 6.0 kg (13.2 lbs)
- Minimum Temperature
- -55 °C (-67 °F)
- Response Time
- T90 less than 3 seconds
- Maximum Temperature
- +75 °C (+167 °F)
Brand
- Brand
- Honeywell
Category
- Sub-Category
- Open Path Gas Detectors & Transmitters
Range
- Humidity Range
- 0–99 % RH Non-condensing
- Sensor Range
- 60 m to 330 m (196 to 1,082 ft)
Alarm
- Alarm Settings
- Recommended High Alarm - 3 LEL.m
- Recommended Low Alarm - 1 LEL.m
Analog
- Analog Output Signal Type
- 4-20mA standard
Certifications
- Standards
- EN 50270: (EMC)NEWLINEIEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EUNEWLINEIEC/EN/UL/CSA 61010 (Electrical Safety)NEWLINEFCC / ICNEWLINERoHS, China RoHS
Features & Benefits
- Features
- Bluetooth® enabled
Material
- Material
- 316L Stainless Steel
Relay
- Relay Output Configuration
- Relay 1 is Alarm Level 1, Relay 2 is Alarm Level 2, Relay 3 Indicates Faults
- Relay Activation Settings
- Single Pole Double Throw (SPDT)
- Relay Rated Load
- Max. 32 Vdc/ac, max. 2 A resistive load
Sensor
- Sensor Type
- Open Path Infrared
- Sensing Method
- Near Band Infrared
Wireless
- Wireless Technology
- Bluetooth® (range up to 20 m (66 ft)
Additional Specifications
- Ingress Protection
- IP66/67
- Gas Type
- Flammable Hydrocarbon
- Visual Indicators
- LEDs on the transmitter and a high visibility HALO light ring on the receiver
- Number of Relay Outputs
- 3
- Mounting
- Universal Mounting Bracket Included
- Maximum Pressure
- 105.5 kPa (1055 mBar, non-compensated) kilopascal
- NEMA Rating
- Type 4X, in accordance with NEMA 250
Others
- Weight
- Receiver 6.1 kg (13.4 lbs), Transmitter 6.0 kg (13.2 lbs)
- Minimum Temperature
- -55 °C (-67 °F)
- Response Time
- T90 less than 3 seconds
- Maximum Temperature
- +75 °C (+167 °F)
- Brand : Honeywell
- Weight : Receiver 6.1 kg (13.4 lbs), Transmitter 6.0 kg (13.2 lbs)
- Minimum Temperature : -55 °C (-67 °F)
- Response Time : T90 less than 3 seconds
- Maximum Temperature : +75 °C (+167 °F)
- Sub-Category : Open Path Gas Detectors & Transmitters
- Humidity Range : 0–99 % RH Non-condensing
- Sensor Range : 60 m to 330 m (196 to 1,082 ft)
- Alarm Settings : Recommended High Alarm - 3 LEL.m|Recommended Low Alarm - 1 LEL.m
- Analog Output Signal Type : 4-20mA standard
- Standards : EN 50270: (EMC)NEWLINEIEC/EN 61000-6-4; Radio Equipment Directive 2014/53/EUNEWLINEIEC/EN/UL/CSA 61010 (Electrical Safety)NEWLINEFCC / ICNEWLINERoHS, China RoHS
- Features : Bluetooth® enabled
- Material : 316L Stainless Steel
- Relay Output Configuration : Relay 1 is Alarm Level 1, Relay 2 is Alarm Level 2, Relay 3 Indicates Faults
- Relay Activation Settings : Single Pole Double Throw (SPDT)
- Relay Rated Load : Max. 32 Vdc/ac, max. 2 A resistive load
- Sensor Type : Open Path Infrared
- Sensing Method : Near Band Infrared
- Wireless Technology : Bluetooth® (range up to 20 m (66 ft)
- Ingress Protection : IP66/67
- Gas Type : Flammable Hydrocarbon
- Visual Indicators : LEDs on the transmitter and a high visibility HALO light ring on the receiver
- Number of Relay Outputs : 3
- Mounting : Universal Mounting Bracket Included
- Maximum Pressure : 105.5 kPa (1055 mBar, non-compensated) kilopascal
- NEMA Rating : Type 4X, in accordance with NEMA 250
Data Sheet
Manuals and Guides
Software
Brochure
Certificate
Please sign in to view part numbers available for purchase based on your account Sign In