/content/sps/ca/en/search-results.html

    Transportable Area Monitoring

    AreaRAE Pro

    The first choice of first responders

    Overview

    For years, you’ve relied on AreaRAE as a first line of defense. As the threats have evolved, our technology has, too. Today’s AreaRAE Pro wireless multi-gas, multi-threat detector is equipped with more sensors, more versatility, and more insight into threats happening in real-time—arming you with the information you need when seconds count.

    Features and Benefits:

    • Monitors up to seven threats, including Gamma radiation , VOCs, combustibles, Toxics and Oxygen
    • Ppb performance level on VOCs measurement
    • Dedicated gamma sensor slot
    • Local weather station
    • Part of ConneXt Safety Solutions with ISM and Wi-Fi wireless configurations
    • Wireless technology sends real-time data to command station up to two miles (3km) away
    • Secondary radio module (Mesh) act as an communication Hub for other wireless devices
    • Ruggedized, portable, and weather-resistant design for harsh environments

    Application:

    • CBRNE
    • Clandestine Labs
    • Decontamination
    • Emergency Response
    • Fire Overhaul
    • Hazmat Response
    • Urban Search & Rescue
    • Venue Protection
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Brand

    • Brand
      • RAE

    Sampling

    • Sampling Pump Range
      • 100ft (30m)

    Category

    • Sub-Category
      • Transportable

    Dimension & Weight

    • Instrument Size
      • 12.36” x 12.04” x 6.53”

    Range

    • Sensor Range
      • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm), Gamma (0.01 μSv/h to 0.2 mSv/h)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-20 hours

    Certifications

    • Standards & Certifications
      • US and Canada: Class 1, Division 2, Groups A, B, C, D

    Datalogging

    • Datalogging
      • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

    Features & Benefits

    • Features & Benefits
      • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat

    Options

    • User Options
      • 3 operation and programming keys

    Warranty

    • Warranty
      • Four years for O2 Liquid Oxygen sensors

    Wireless

    • Wireless Technology
      • BLE, MESH, WiFi

    Additional Specifications

    • Gas Type
      • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma
    • Ingress Protection
      • IP65

    Others

    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 14.33 US Pound
      • 6.5 kilogram
    • Maximum Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius

    Brand

    • Brand
      • RAE

    Sampling

    • Sampling Pump Range
      • 100ft (30m)

    Category

    • Sub-Category
      • Transportable

    Dimension & Weight

    • Instrument Size
      • 12.36” x 12.04” x 6.53”

    Range

    • Sensor Range
      • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm), Gamma (0.01 μSv/h to 0.2 mSv/h)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-20 hours

    Certifications

    • Standards & Certifications
      • US and Canada: Class 1, Division 2, Groups A, B, C, D

    Datalogging

    • Datalogging
      • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

    Features & Benefits

    • Features & Benefits
      • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat

    Options

    • User Options
      • 3 operation and programming keys

    Warranty

    • Warranty
      • Four years for O2 Liquid Oxygen sensors

    Wireless

    • Wireless Technology
      • BLE, MESH, WiFi

    Additional Specifications

    • Gas Type
      • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma
    • Ingress Protection
      • IP65

    Others

    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 14.33 US Pound
      • 6.5 kilogram
    • Maximum Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius
    • Brand : RAE
    • Sampling Pump Range : 100ft (30m)
    • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
    • Weight : 14.33 US Pound|6.5 kilogram
    • Maximum Temperature : 140 degree Fahrenheit|60 degree Celsius
    • Sub-Category : Transportable
    • Instrument Size : 12.36” x 12.04” x 6.53”
    • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm), Gamma (0.01 μSv/h to 0.2 mSv/h)
    • Humidity Range : 0%-95% percent
    • Alarm Type : Audible, Visual, Vibrating
    • Battery Run Time : 12-20 hours
    • Standards & Certifications : US and Canada: Class 1, Division 2, Groups A, B, C, D
    • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
    • Features & Benefits : Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
    • User Options : 3 operation and programming keys
    • Warranty : Four years for O2 Liquid Oxygen sensors
    • Wireless Technology : BLE, MESH, WiFi
    • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma
    • Ingress Protection : IP65
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    VOC ZeroingTube Data Sheet
    application/pdf 77.52 KB
    7/15/2021
    77.52 KB
    AreaRAE Pro Data Sheet
    application/pdf 537.7 KB
    7/15/2021
    537.7 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Plus & AreaRAE Pro - User Guide - Korean
    application/pdf 18.73 MB
    5/14/2024
    18.73 MB
    AreaRAE Plus & AreaRAE Pro - User Guide - Japanese
    application/pdf 19.31 MB
    5/14/2024
    19.31 MB
    AreaRAE Plus & AreaRAE Pro - User Guide - German
    application/pdf 18.72 MB
    5/14/2024
    18.72 MB
    AreaRAE Plus & AreaRAE Pro - User Guide - English
    application/pdf 18.87 MB
    5/14/2024
    18.87 MB
    AreaRAE Pro and AreaRAE Plus QuickStart Guide
    application/pdf 1.8 MB
    1/11/2022
    1.8 MB
    Firmware
    Name
    Description
    File Size
    Date
    Size
    Area RAE 1.12 Firmware and Release Notes
    application/zip 2.01 MB
    8/18/2023
    2.01 MB
    AREARAE Plus / Pro v 1.08
    application/zip 1.57 MB
    7/15/2021
    1.57 MB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    Fenceline Monitoring with Honeywell Fenceline Solutions
    application/pdf 1.4 MB
    9/24/2024
    1.4 MB
    AreaRAE Pro Brochure
    application/pdf 2.87 MB
    7/15/2021
    2.87 MB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    AreaRAE PlusPro Technical Note 106A
    application/pdf 428.08 KB
    7/15/2021
    428.08 KB
    AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
    application/pdf 146.2 KB
    8/10/2022
    146.2 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    application/pdf 1.08 MB
    7/15/2021
    1.08 MB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
    application/pdf 1.02 MB
    7/15/2021
    1.02 MB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    application/pdf 787.55 KB
    7/15/2021
    787.55 KB
    Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 176 Basics Of Nuclear Radiation
    application/pdf 1.31 MB
    7/15/2021
    1.31 MB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    application/pdf 884.91 KB
    7/15/2021
    884.91 KB
    White Paper
    Name
    Description
    File Size
    Date
    Size
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    application/pdf 949.42 KB
    7/15/2021
    949.42 KB
    Certificate
    Name
    Description
    File Size
    Date
    Size
    Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
    application/pdf 817.01 KB
    7/15/2021
    817.01 KB
    AreaRAE Plus and Pro - Certificate of compliance
    application/pdf 45.13 KB
    9/27/2021
    45.13 KB
    AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
    application/pdf 194.1 KB
    1/11/2022
    194.1 KB
    RM2400A EU Component of Conformity to Certificates
    application/pdf 110.56 KB
    1/3/2022
    110.56 KB
    AreaRAE Plus and Pro - EU Declaration of Conformity
    application/pdf 154.78 KB
    1/11/2022
    154.78 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    application/pdf 826.34 KB
    7/15/2021
    826.34 KB
    Application Note 232 Radioisotopes in Everyday Life
    application/pdf 582.87 KB
    3/4/2022
    582.87 KB
    Application Note 228 - Facility and Venue Protection
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    application/pdf 831.7 KB
    7/15/2021
    831.7 KB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Name
    Description
    File Size
    Date
    Size
    AreaRAE PlusPro Technical Note 106A
    application/pdf 428.08 KB
    7/15/2021
    428.08 KB
    Fenceline Monitoring with Honeywell Fenceline Solutions
    application/pdf 1.4 MB
    9/24/2024
    1.4 MB
    AreaRAE Plus & AreaRAE Pro - User Guide - Korean
    application/pdf 18.73 MB
    5/14/2024
    18.73 MB
    AreaRAE Plus & AreaRAE Pro - User Guide - Japanese
    application/pdf 19.31 MB
    5/14/2024
    19.31 MB
    AreaRAE Plus & AreaRAE Pro - User Guide - German
    application/pdf 18.72 MB
    5/14/2024
    18.72 MB
    AreaRAE Plus & AreaRAE Pro - User Guide - English
    application/pdf 18.87 MB
    5/14/2024
    18.87 MB
    Area RAE 1.12 Firmware and Release Notes
    application/zip 2.01 MB
    8/18/2023
    2.01 MB
    AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
    application/pdf 146.2 KB
    8/10/2022
    146.2 KB
    Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
    application/pdf 817.01 KB
    7/15/2021
    817.01 KB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    AreaRAE Pro Brochure
    application/pdf 2.87 MB
    7/15/2021
    2.87 MB
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    application/pdf 826.34 KB
    7/15/2021
    826.34 KB
    VOC ZeroingTube Data Sheet
    application/pdf 77.52 KB
    7/15/2021
    77.52 KB
    AreaRAE Pro and AreaRAE Plus QuickStart Guide
    application/pdf 1.8 MB
    1/11/2022
    1.8 MB
    Application Note 232 Radioisotopes in Everyday Life
    application/pdf 582.87 KB
    3/4/2022
    582.87 KB
    AreaRAE Plus and Pro - Certificate of compliance
    application/pdf 45.13 KB
    9/27/2021
    45.13 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    Technical Note 169 Theory And Operation Of NDIR Sensors
    application/pdf 994.45 KB
    8/3/2022
    994.45 KB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    application/pdf 1.08 MB
    7/15/2021
    1.08 MB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    application/pdf 125.12 KB
    1/23/2024
    125.12 KB
    AreaRAE Pro Data Sheet
    application/pdf 537.7 KB
    7/15/2021
    537.7 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Application Note 228 - Facility and Venue Protection
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
    application/pdf 1.02 MB
    7/15/2021
    1.02 MB
    AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
    application/pdf 194.1 KB
    1/11/2022
    194.1 KB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    AREARAE Plus / Pro v 1.08
    application/zip 1.57 MB
    7/15/2021
    1.57 MB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    application/pdf 787.55 KB
    7/15/2021
    787.55 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    RM2400A EU Component of Conformity to Certificates
    application/pdf 110.56 KB
    1/3/2022
    110.56 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    application/pdf 949.42 KB
    7/15/2021
    949.42 KB
    Technical Note 176 Basics Of Nuclear Radiation
    application/pdf 1.31 MB
    7/15/2021
    1.31 MB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    application/pdf 831.7 KB
    7/15/2021
    831.7 KB
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    application/pdf 884.91 KB
    7/15/2021
    884.91 KB
    AreaRAE Plus and Pro - EU Declaration of Conformity
    application/pdf 154.78 KB
    1/11/2022
    154.78 KB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Name
    Description
    File Size
    Date
    Size
    VOC ZeroingTube Data Sheet
    77.52 KB
    7/15/2021
    AreaRAE Pro Data Sheet
    537.7 KB
    7/15/2021
    AreaRAE Plus & AreaRAE Pro - User Guide - Korean
    18.73 MB
    5/14/2024
    AreaRAE Plus & AreaRAE Pro - User Guide - Japanese
    19.31 MB
    5/14/2024
    AreaRAE Plus & AreaRAE Pro - User Guide - German
    18.72 MB
    5/14/2024
    AreaRAE Plus & AreaRAE Pro - User Guide - English
    18.87 MB
    5/14/2024
    AreaRAE Pro and AreaRAE Plus QuickStart Guide
    1.8 MB
    1/11/2022
    Area RAE 1.12 Firmware and Release Notes
    2.01 MB
    8/18/2023
    AREARAE Plus / Pro v 1.08
    1.57 MB
    7/15/2021
    Fenceline Monitoring with Honeywell Fenceline Solutions
    1.4 MB
    9/24/2024
    AreaRAE Pro Brochure
    2.87 MB
    7/15/2021
    AreaRAE PlusPro Technical Note 106A
    428.08 KB
    7/15/2021
    AreaRAE Plus & AreaRAE Pro - Technical Note TN-201
    146.2 KB
    8/10/2022
    Technical Note 144 Handling LEL Sensor Poisons
    802.28 KB
    8/3/2022
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    911.54 KB
    7/15/2021
    Technical Note 169 Theory And Operation Of NDIR Sensors
    994.45 KB
    8/3/2022
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    795.02 KB
    7/15/2021
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    1.08 MB
    7/15/2021
    Technical Note 148 Defining The Interval Between Calibration Checks
    839.32 KB
    12/14/2022
    MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
    125.12 KB
    1/23/2024
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    839.29 KB
    8/3/2022
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    950.72 KB
    7/15/2021
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    814.89 KB
    7/15/2021
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
    1.02 MB
    7/15/2021
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    1.09 MB
    2/8/2022
    Technical Note 130 Setting Alarm Limits For Mixtures
    788.83 KB
    7/15/2021
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    787.55 KB
    7/15/2021
    Technical Note 185 Response Guidelines for Inadvertent Movement or Illicit Trafficking of Radioactive Material
    1.1 MB
    7/15/2021
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    930.69 KB
    7/15/2021
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Technical Note 176 Basics Of Nuclear Radiation
    1.31 MB
    7/15/2021
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    609.21 KB
    7/15/2021
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    884.91 KB
    7/15/2021
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    949.42 KB
    7/15/2021
    Technical Note 177 ITRAP Certification Of Radiation Monitors (Illicit Trafficking Radiation Assessment Program)
    817.01 KB
    7/15/2021
    AreaRAE Plus and Pro - Certificate of compliance
    45.13 KB
    9/27/2021
    AreaRAE Pro RAEMet Sensor EU Declaration of Conformity
    194.1 KB
    1/11/2022
    RM2400A EU Component of Conformity to Certificates
    110.56 KB
    1/3/2022
    AreaRAE Plus and Pro - EU Declaration of Conformity
    154.78 KB
    1/11/2022
    Application Note 203: PIDs As HazMat Response Tools
    1.26 MB
    7/15/2021
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    826.34 KB
    7/15/2021
    Application Note 232 Radioisotopes in Everyday Life
    582.87 KB
    3/4/2022
    Application Note 228 - Facility and Venue Protection
    1.1 MB
    7/15/2021
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    7/15/2021
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    964.88 KB
    7/15/2021
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    655.59 KB
    7/15/2021
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    831.7 KB
    7/15/2021
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    1.07 MB
    7/15/2021
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list