Overview
- Brand
- Honeywell
Dimensions & Weight
- Weight range
- 1400 g
- Dimension
- 118 mm x 159 mm x 93 mm
Technical Specifications
- Humidity Range
- 0 to 99% (Non-Condensing)
- Analog Outputs
- 0 to 22 mA
- Wireless Communication
- Bluetooth 4.0 (Bluetooth Low Energy)
- Maximum Pressure
- 110 kPa
- Measuring Range
- CO: 0 to 300 ppm (Adjustable Between 50 and 1000 Ppm)
- Combustible: 0 to 100 % LEL (Adjustable Between 20 and 100% LEL, Factory Calibrated to Methane)
- H2: 0 to 1,000 ppm
- H2S High Range: 0 to 100 ppm (Adjustable Between 50 and 200 ppm)
- H2S Low Range: 0 to 50 ppm (Adjustable Between 10 and 50 ppm)
- O2: 0 to 25% vol
- Digital Output
- Modbus RTU
Operating Characteristics
- Minimum Temperature
- -40˚C
- Storage Temperature
- 0 to 30°C
Features
- Features & Benefits
- Choose from a Range of mA or Modbus Output Versions for Flexible System Design to Meet the Customers Requirements
- Manage the Detector without Making a Physical Connection. Remove the Need for Physical Access to Hard-to-Reach Devices
- Multi-Color Visual Indicator to Stow Status Makes it Easier to Know the Detector Status Immediately and Identify Detectors that Require Attention or are Warning of Danger
- One Person Calibration without the Need to Open the Detector. Saves Time and Removes Need for Hot Work Permit
- Selectable Source or Sink Current for Analog Output Enables One Detector to be Suitable for Both System Configurations
- Simplified Maintenance with Familiar Smartphone Technology Saves Money and Time
- The Ingress Protection of NEMA 4X/IP66 Allows Units to be Installed in Outdoor Environemtns
- Visual Indicators
- Flashing Blue: Bluetooth Pairing in Progress
- Flashing Green and Yellow: Warning
- Flashing Green: Normal
- Flashing Red: Alarm
- Flashing Yellow: Fault
- Solid Blue: Bluetooth Connection Established
- Solid Yellow: Inhibited
Electrical Specifications
- Maximum Operating Current
- 850 mA
- Electrical Connection
- Pluggable Rising Clamp Style, 0.5 to 1.5 sq.mm (20 to 16 AWG)
- Operating Voltage
- 24 VDC
Standards & Certifications
- NEMA Rating
- NEMA 4X
- Ingress Protection
- IP66
Material Specifications
- Enclosure Material
- Aluminum Alloy LM20 (Charcoal or Yellow)
Applications & Compatibility
- Application
- Battery Charging Facilities
- Fuelling Depots
- Manufacturing Facilities and Factories
- Petrochemical Plants
- Vehicle Test Facilities
- Water Treatment Plants
Overview
- Brand
- Honeywell
Dimensions & Weight
- Weight range
- 1400 g
- Dimension
- 118 mm x 159 mm x 93 mm
Technical Specifications
- Humidity Range
- 0 to 99% (Non-Condensing)
- Analog Outputs
- 0 to 22 mA
- Wireless Communication
- Bluetooth 4.0 (Bluetooth Low Energy)
- Maximum Pressure
- 110 kPa
- Measuring Range
- CO: 0 to 300 ppm (Adjustable Between 50 and 1000 Ppm)
- Combustible: 0 to 100 % LEL (Adjustable Between 20 and 100% LEL, Factory Calibrated to Methane)
- H2: 0 to 1,000 ppm
- H2S High Range: 0 to 100 ppm (Adjustable Between 50 and 200 ppm)
- H2S Low Range: 0 to 50 ppm (Adjustable Between 10 and 50 ppm)
- O2: 0 to 25% vol
- Digital Output
- Modbus RTU
Operating Characteristics
- Minimum Temperature
- -40˚C
- Storage Temperature
- 0 to 30°C
Features
- Features & Benefits
- Choose from a Range of mA or Modbus Output Versions for Flexible System Design to Meet the Customers Requirements
- Manage the Detector without Making a Physical Connection. Remove the Need for Physical Access to Hard-to-Reach Devices
- Multi-Color Visual Indicator to Stow Status Makes it Easier to Know the Detector Status Immediately and Identify Detectors that Require Attention or are Warning of Danger
- One Person Calibration without the Need to Open the Detector. Saves Time and Removes Need for Hot Work Permit
- Selectable Source or Sink Current for Analog Output Enables One Detector to be Suitable for Both System Configurations
- Simplified Maintenance with Familiar Smartphone Technology Saves Money and Time
- The Ingress Protection of NEMA 4X/IP66 Allows Units to be Installed in Outdoor Environemtns
- Visual Indicators
- Flashing Blue: Bluetooth Pairing in Progress
- Flashing Green and Yellow: Warning
- Flashing Green: Normal
- Flashing Red: Alarm
- Flashing Yellow: Fault
- Solid Blue: Bluetooth Connection Established
- Solid Yellow: Inhibited
Electrical Specifications
- Maximum Operating Current
- 850 mA
- Electrical Connection
- Pluggable Rising Clamp Style, 0.5 to 1.5 sq.mm (20 to 16 AWG)
- Operating Voltage
- 24 VDC
Standards & Certifications
- NEMA Rating
- NEMA 4X
- Ingress Protection
- IP66
Material Specifications
- Enclosure Material
- Aluminum Alloy LM20 (Charcoal or Yellow)
Applications & Compatibility
- Application
- Battery Charging Facilities
- Fuelling Depots
- Manufacturing Facilities and Factories
- Petrochemical Plants
- Vehicle Test Facilities
- Water Treatment Plants
- Brand : Honeywell
- Weight range : 1400 g
- Humidity Range : 0 to 99% (Non-Condensing)
- Minimum Temperature : -40˚C
- Analog Outputs : 0 to 22 mA
- Features & Benefits : Choose from a Range of mA or Modbus Output Versions for Flexible System Design to Meet the Customers Requirements|Manage the Detector without Making a Physical Connection. Remove the Need for Physical Access to Hard-to-Reach Devices|Multi-Color Visual Indicator to Stow Status Makes it Easier to Know the Detector Status Immediately and Identify Detectors that Require Attention or are Warning of Danger|One Person Calibration without the Need to Open the Detector. Saves Time and Removes Need for Hot Work Permit|Selectable Source or Sink Current for Analog Output Enables One Detector to be Suitable for Both System Configurations|Simplified Maintenance with Familiar Smartphone Technology Saves Money and Time|The Ingress Protection of NEMA 4X/IP66 Allows Units to be Installed in Outdoor Environemtns
- Maximum Operating Current : 850 mA
- Wireless Communication : Bluetooth 4.0 (Bluetooth Low Energy)
- Visual Indicators : Flashing Blue: Bluetooth Pairing in Progress|Flashing Green and Yellow: Warning|Flashing Green: Normal|Flashing Red: Alarm|Flashing Yellow: Fault|Solid Blue: Bluetooth Connection Established|Solid Yellow: Inhibited
- NEMA Rating : NEMA 4X
- Maximum Pressure : 110 kPa
- Ingress Protection : IP66
- Electrical Connection : Pluggable Rising Clamp Style, 0.5 to 1.5 sq.mm (20 to 16 AWG)
- Storage Temperature : 0 to 30°C
- Operating Voltage : 24 VDC
- Measuring Range : CO: 0 to 300 ppm (Adjustable Between 50 and 1000 Ppm)|Combustible: 0 to 100 % LEL (Adjustable Between 20 and 100% LEL, Factory Calibrated to Methane)|H2: 0 to 1,000 ppm|H2S High Range: 0 to 100 ppm (Adjustable Between 50 and 200 ppm)|H2S Low Range: 0 to 50 ppm (Adjustable Between 10 and 50 ppm)|O2: 0 to 25% vol
- Enclosure Material : Aluminum Alloy LM20 (Charcoal or Yellow)
- Dimension : 118 mm x 159 mm x 93 mm
- Digital Output : Modbus RTU
- Application : Battery Charging Facilities|Fuelling Depots|Manufacturing Facilities and Factories|Petrochemical Plants|Vehicle Test Facilities|Water Treatment Plants