Thermostats
3200 Series
Hermetically sealed. Tight tolerances & differentials. Pre-set & tamper proof. SPST contacts. Mounting brackets, terminals
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Features
- Hermetically sealed
- Tight tolerances
- Tight differentials
- Space qualified
- Hi-Rel
Potential Applications
- Satellites
- International space station
- Space shuttle
- Spacecraft
Technical Specifications
- Acceleration Range/Limits
- MIL-STD-202, Method 212; 20 G
- Thermostat Environmental Exposure Range
- -65 °C to 177 °C [-85 °F to 350 °F]
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.025 Ohm max.
- Insulation Resistance
- MIL-STD-202, Method 302; 500 MOhm
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac
Features
- Vibration
- MIL-STD-202, Method 204; 30 G : MIL-STD-202, Method 214; 50 G
- Thermal Shock
- MIL-STD-202, Method 107; Cond. B
- Shock
- MIL-STD-202, Method 213; 750 G
- Seal Type
- MIL-STD-202, Method 112; Cond. C
- Salt Spray
- MIL-STD-202, Method 101; Cond. B
Operating Characteristics
- Operating Temperature
- -51 °C to 163 °C [-60 °F to 325 °F]
- Humidity
- MIL-STD-202, Method 106
Standards & Certifications
- Agency Approvals and Standards
- MIL-PRF-24236
Others
- Industry
- Construction
- Life Sciences
- Manufacturing
Technical Specifications
- Acceleration Range/Limits
- MIL-STD-202, Method 212; 20 G
- Thermostat Environmental Exposure Range
- -65 °C to 177 °C [-85 °F to 350 °F]
- Thermostat Contact Resistance
- MIL-STD-202, Method 307; 0.025 Ohm max.
- Insulation Resistance
- MIL-STD-202, Method 302; 500 MOhm
- Dielectric Strength
- MIL-STD-202, Method 301; 1250 Vac
Features
- Vibration
- MIL-STD-202, Method 204; 30 G : MIL-STD-202, Method 214; 50 G
- Thermal Shock
- MIL-STD-202, Method 107; Cond. B
- Shock
- MIL-STD-202, Method 213; 750 G
- Seal Type
- MIL-STD-202, Method 112; Cond. C
- Salt Spray
- MIL-STD-202, Method 101; Cond. B
Operating Characteristics
- Operating Temperature
- -51 °C to 163 °C [-60 °F to 325 °F]
- Humidity
- MIL-STD-202, Method 106
Standards & Certifications
- Agency Approvals and Standards
- MIL-PRF-24236
Others
- Industry
- Construction
- Life Sciences
- Manufacturing
- Acceleration Range/Limits : MIL-STD-202, Method 212; 20 G
- Vibration : MIL-STD-202, Method 204; 30 G : MIL-STD-202, Method 214; 50 G
- Thermostat Environmental Exposure Range : -65 °C to 177 °C [-85 °F to 350 °F]
- Thermostat Contact Resistance : MIL-STD-202, Method 307; 0.025 Ohm max.
- Thermal Shock : MIL-STD-202, Method 107; Cond. B
- Shock : MIL-STD-202, Method 213; 750 G
- Seal Type : MIL-STD-202, Method 112; Cond. C
- Salt Spray : MIL-STD-202, Method 101; Cond. B
- Operating Temperature : -51 °C to 163 °C [-60 °F to 325 °F]
- Insulation Resistance : MIL-STD-202, Method 302; 500 MOhm
- Industry : Construction|Life Sciences|Manufacturing
- Humidity : MIL-STD-202, Method 106
- Dielectric Strength : MIL-STD-202, Method 301; 1250 Vac
- Agency Approvals and Standards : MIL-PRF-24236
Please sign in to access more documents.
Once signed in, you may be able to access additional documents for your account.
Data Sheet
Manuals and Guides
Brochure
Technical Note
Application Note
eBook
Please sign in to view part numbers available for purchase based on your account Sign In