High Tech & Semiconductor
ACM 150G2
ACM 150G2 FTIR Centralized Gas Monitoring System
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
- Up to 40 measuring points can be centrally located on one device, such as process tools, gas and chemical storage units, gas cabinets, distribution boxes, process tools, emission measurement, and ambient air monitoring.
- Up to 15 gases can be detected per measuring point, lowering your cost-per-gas-per-point monitoring.
- Self-diagnostic programming detects faults and critical alarms, eliminating many maintenance calls.
- Communications options meet unique site requirements (Open Platform Communications (OPC), ControlNet™, Modbus®, and Profibus®
- Detect multiple gases, chemicals, or odors in an industrial process*
- Overlay the spectrum of detected gas against a library of spectra for precise detection as a user validation tool
- Up to 40 measuring points can be detected sequentially
- 80 configurable relay points for increased flexibility
- Sealed aluminum body prevents moisture intrusion, protecting critical internal components
- Double IR scan ensures reliable performance and reduces false alarms
- Optimized built-in measuring/self-diagnostics eliminate on-site gas calibration
- Desiccant replacement cycle of 3-to-5 years
- Composite sampling of up to four measuring points provides faster measurement
- Easy-to-service gas cell with stainless-steel body construction prevents costly downtime
- Better Signal to Noise Ratio (SNR) performance allows for lower LDL measurements
- Improved HMI with modernized solid-state computer operating on a world-proven operating system
- Large user-friendly touchscreen interface
- Flexible communications options meet unique site requirements
- Robust solid-state drive
- Embedded web server for remote access
- Refer to the ACM 150G2/100 Gas List or ask your regional sales rep for more information. More than two hundred gases detectable. Our engineers may be able to generate a new method for gases not listed.
- Analysis method: Continuous scan FTIR (Fourier Transform Infrared) analyzer
- Gas cell path: 5.0 m path length
- Scanning rate: ≤ 15 sec per point
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Brand
- Brand
- Honeywell
Dimensions & Weight
- Size
- H: 66 in D: 25 in W: 34 in
Standards & Certifications
- Certificates and Standards
- CE Certified
- EN 50270:2015/AC:2016
- EN 61000-6-4:2007/A1:2011
- EN 61010-1:2010
- EN IEC 63000:2018
- EN ISO/IEC 17050-1:2010
- RoHS Directive 2015/863/EU
- UL 61010
- Ingress Protection
- IP20
Technical Specifications
- Sample Point Capacity
- Composite Sampling up to 4 points
- Point Configurations: 10, 20, 30 or 40
- Tubing Sample Inlet
- 0.375 in (Swagelok Connector)
- Operating Altitude
- Up to 6,562 ft (2,000 m)
- Network Interface
- ControlNet
- LonWorks
- Modbus
- OPC Drivers
- Profibus
- Analysis Method
- Continuous Scan FT-IR (Fourier Transform Infrared) Analyzer
- Scanning Rate
- ≤15 sec/Point
- Sample Lines
- ID: 0.25 in OD: 0.375 in PTFE
- Exhaust Line
- 1.5 in NPT (15 cfm)
- Data Logging
- 30 Days for All Spectra
- 90 Days for Alarms
- Gas Type
- Organic, PFC, CFC, HFC, Metal Organic, NF, and Other Inorganic Gases
- Relays
- 0 x DPDT (Double-Pole Double-Thow)
Features
- Features & Benefits
- All Connections for Power, Sample Lines, Compressed Air, and Nitrogen are Located on the Top of the Unit
- Electric or Venturi (Compressed Air) Pump Options, with Redundant Electric Backup Pump as Standard
- Enhanced Data Processing Reduces System Slowdowns while Boosting Performance and Reliability
- Every ACM 150G2 is Equipped with 80 Programmable Relays
- FT-IR Bench: Provides More Gas Detection Options (Up to 15 Gases per Measuring Point are Possible)
- Quickly Evaluates the IR Spectra, Stores Critical Data, Transmits Alarms, Activates Point Relays, and Monitors Diagnostics and Test Functions
- Sealed Aluminum Body: Prevents Moisture Intrusion, Reduces EMI, and Boosts Uptime
- Software Method can be Configured to Detect a Large Variety of Gases, Odors, or Chemical Compounds
- Stainless Steel Construction Provides Best-in-Class SNR Performance with Ease of Service and Maintenance
- Touchscreen Computer, Improved HMI for Easier Viewing, Web-Based User Interface
- Display Type
- Touch Screen User Friendly Interface
Operating Characteristics
- Operating Humidity
- 80% at Temperatures up to 88°F (31°C)
Electrical Specifications
- Power Requirement
- 115 V AC, 20A
- 230 V AC, 10A
- Operating Voltage
- ±10% of the Nominal Voltage
Brand
- Brand
- Honeywell
Dimensions & Weight
- Size
- H: 66 in D: 25 in W: 34 in
Standards & Certifications
- Certificates and Standards
- CE Certified
- EN 50270:2015/AC:2016
- EN 61000-6-4:2007/A1:2011
- EN 61010-1:2010
- EN IEC 63000:2018
- EN ISO/IEC 17050-1:2010
- RoHS Directive 2015/863/EU
- UL 61010
- Ingress Protection
- IP20
Technical Specifications
- Sample Point Capacity
- Composite Sampling up to 4 points
- Point Configurations: 10, 20, 30 or 40
- Tubing Sample Inlet
- 0.375 in (Swagelok Connector)
- Operating Altitude
- Up to 6,562 ft (2,000 m)
- Network Interface
- ControlNet
- LonWorks
- Modbus
- OPC Drivers
- Profibus
- Analysis Method
- Continuous Scan FT-IR (Fourier Transform Infrared) Analyzer
- Scanning Rate
- ≤15 sec/Point
- Sample Lines
- ID: 0.25 in OD: 0.375 in PTFE
- Exhaust Line
- 1.5 in NPT (15 cfm)
- Data Logging
- 30 Days for All Spectra
- 90 Days for Alarms
- Gas Type
- Organic, PFC, CFC, HFC, Metal Organic, NF, and Other Inorganic Gases
- Relays
- 0 x DPDT (Double-Pole Double-Thow)
Features
- Features & Benefits
- All Connections for Power, Sample Lines, Compressed Air, and Nitrogen are Located on the Top of the Unit
- Electric or Venturi (Compressed Air) Pump Options, with Redundant Electric Backup Pump as Standard
- Enhanced Data Processing Reduces System Slowdowns while Boosting Performance and Reliability
- Every ACM 150G2 is Equipped with 80 Programmable Relays
- FT-IR Bench: Provides More Gas Detection Options (Up to 15 Gases per Measuring Point are Possible)
- Quickly Evaluates the IR Spectra, Stores Critical Data, Transmits Alarms, Activates Point Relays, and Monitors Diagnostics and Test Functions
- Sealed Aluminum Body: Prevents Moisture Intrusion, Reduces EMI, and Boosts Uptime
- Software Method can be Configured to Detect a Large Variety of Gases, Odors, or Chemical Compounds
- Stainless Steel Construction Provides Best-in-Class SNR Performance with Ease of Service and Maintenance
- Touchscreen Computer, Improved HMI for Easier Viewing, Web-Based User Interface
- Display Type
- Touch Screen User Friendly Interface
Operating Characteristics
- Operating Humidity
- 80% at Temperatures up to 88°F (31°C)
Electrical Specifications
- Power Requirement
- 115 V AC, 20A
- 230 V AC, 10A
- Operating Voltage
- ±10% of the Nominal Voltage
- Brand : Honeywell
- Size : H: 66 in D: 25 in W: 34 in
- Certificates and Standards : CE Certified|EN 50270:2015/AC:2016|EN 61000-6-4:2007/A1:2011|EN 61010-1:2010|EN IEC 63000:2018|EN ISO/IEC 17050-1:2010|RoHS Directive 2015/863/EU|UL 61010
- Sample Point Capacity : Composite Sampling up to 4 points|Point Configurations: 10, 20, 30 or 40
- Tubing Sample Inlet : 0.375 in (Swagelok Connector)
- Features & Benefits : All Connections for Power, Sample Lines, Compressed Air, and Nitrogen are Located on the Top of the Unit|Electric or Venturi (Compressed Air) Pump Options, with Redundant Electric Backup Pump as Standard|Enhanced Data Processing Reduces System Slowdowns while Boosting Performance and Reliability|Every ACM 150G2 is Equipped with 80 Programmable Relays|FT-IR Bench: Provides More Gas Detection Options (Up to 15 Gases per Measuring Point are Possible)|Quickly Evaluates the IR Spectra, Stores Critical Data, Transmits Alarms, Activates Point Relays, and Monitors Diagnostics and Test Functions|Sealed Aluminum Body: Prevents Moisture Intrusion, Reduces EMI, and Boosts Uptime|Software Method can be Configured to Detect a Large Variety of Gases, Odors, or Chemical Compounds|Stainless Steel Construction Provides Best-in-Class SNR Performance with Ease of Service and Maintenance|Touchscreen Computer, Improved HMI for Easier Viewing, Web-Based User Interface
- Operating Humidity : 80% at Temperatures up to 88°F (31°C)
- Operating Altitude : Up to 6,562 ft (2,000 m)
- Ingress Protection : IP20
- Power Requirement : 115 V AC, 20A|230 V AC, 10A
- Operating Voltage : ±10% of the Nominal Voltage
- Network Interface : ControlNet|LonWorks|Modbus|OPC Drivers|Profibus
- Analysis Method : Continuous Scan FT-IR (Fourier Transform Infrared) Analyzer
- Scanning Rate : ≤15 sec/Point
- Sample Lines : ID: 0.25 in OD: 0.375 in PTFE
- Exhaust Line : 1.5 in NPT (15 cfm)
- Display Type : Touch Screen User Friendly Interface
- Data Logging : 30 Days for All Spectra|90 Days for Alarms
- Gas Type : Organic, PFC, CFC, HFC, Metal Organic, NF, and Other Inorganic Gases
- Relays : 0 x DPDT (Double-Pole Double-Thow)
Manuals and Guides
Brochure
Technical Note
Certificate
Please sign in to view part numbers available for purchase based on your account Sign In