fixed gas detectors
SS4 Flame Detector
Electro-Optical Digital Fire and Flame Detectors
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Electro-optical digital detectors represent leading edge UV and UV/IR technology.
Product Overview:
SS4-A:
The SS4-A represents the world’s pre-eminent UV/IR technology for Electro-Optical Flame Detectors with tens of thousands successfully operating in a multitude of installations worldwide. This multi-spectrum detector senses radiant energy in the ultraviolet (UV), visible and Wide Band Infrared™ (IR) spectrum. The radiant energy from all types of flaming fires will alert the detector to their presence.
To eliminate common nuisance false alarms that occasionally occur with UV-only, IR-only, Dual IR or Dual Mode UV/IR detectors, the SS4 Flame Detectors’ FireLogic signal processing requires that UV, visible and Wide Band IR radiant energy all be evaluated before declaring a fire. The smart detector utilizes real-time signal processing algorithms that are optimized to alarm on all types of fires, while virtually eliminating the possibility of false alarms.
SS4-AS:
The SS4-AS processes UV, IR and Visible (VIS) spectral ranges from ruggedized solar-blind UV, “Quantum-Effect” IR and VIS sensors correspondingly. It is optimized for detection of hydrogen, ethanol, methanol and methane (natural gas) fires and like the other detectors in its family, it responds to Type A, B and C flaming fires.
SS4-AUV:
The SS4-AUV represents the leading edge technology UV optical flame detectors. This flame detector senses radiant energy in the ultraviolet (UV) spectrum. The radiant emissions of flaming fires will alert the detector to their presence.
Additional Features and Benefits:
SS4-A and SS4-AS Features:
- Multi-Spectrum™: senses ultraviolet, visible and Wide Band Infrared™
- Built-in test for optical “through the lens” testing
- False alarm immunity
- Detects hydrocarbon and non-hydrocarbon based fires
- Wide field-of-view and solar-blind
- Adjustable detector sensitivity
- Microprocessor based algorithms: FirePic™, Snapshot™ and Tri-Mode Plot™
- Wide temperature range of operation
- Compatible with standard approved fire alarm panels
- Explosion-proof housing
- Time programmable alarm verification
SS4-AUV Features:
- Senses solar-blink ultraviolet band
- Built-in test for optical “through the lens” testing
- Utilizes long-life, ruggedized UV sensors
- Detects hydrocarbon and non-hydrocarbon based fires
- Wide field-of-view and solar-blind
- Adjustable detector sensitivity
- Microcomputer based algorithms: FirePic™, Snapshot™ and UV Plot
- Wide temperature range of operation
- Compatible with standard approved fire alarm panels
- Explosion-proof housing
- Time programmable alarm verification.
Features & Benefits:
- Detects hydrocarbon and non-hydrocarbon based fires
- Built-in test for optical “through the lens” testing
- False alarm immunity
Quick Specs:
- Sensitivity: Adjustable between 60 ft., 45 ft., 30 ft., and 15 ft. to a 1 sq. ft. gasoline fire
- Response time: 2-5 seconds to 1 sq. ft. of gasoline fire at 60 ft.
- Field-of-view: 120 degrees cone of vision (60 degrees from on axis)
Fire and Gas Consultancy Services
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Overview
- Brand
- Honeywell
- Honeywell
- Warranty
- 2 Years from Date of Shipping
Features
- Sub-Category
- Flame Detectors
- Features & Benefits
- Adjustable Detector Sensitivity
- Adjustable Detector Sensitivity
- Available SS4-A, SS4-AS and SS4-AUV
- Built-In Test For Optical “Through The Lens” Testing
- Built-In Test For Optical “Through The Lens” Testing
- Compatible with Standard Approved Fire Alarm Panels
- Compatible with Standard Approved Fire Alarm Panels
- Detects Hydrocarbon and Non-Hydrocarbon Fires
- Detects Hydrocarbon and Non-Hydrocarbon Fires
- Explosion-Proof Housing
- Explosion-Proof Housing
- False Alarm Immunity
- Microcomputer Based Algorithms: FirePic™, Snapshot™ and UV Plot
- Microprocessor Based Algorithms: FirePic™, Snapshot™ and Tri-Mode Plot™
- Multi-Spectrum Senses Energy in the UV, Vis and WideBand IR™
- Senses Solar-Blink Ultraviolet Band
- Time Programmable Alarm Verification
- Time Programmable Alarm Verification
- Utilizes Long-Life, Ruggedized UV Sensors
- Wide Field of View and Solar Blind
- Wide Field of View and Solar Blind
- Wide Temperature Range of Operation
- Wide Temperature Range of Operation
Dimensions & Weight
- Weight range
- Aluminum: 4 lbs
- Stainless Steel: 7.5 lbs
Technical Specifications
- Humidity Range
- 5 to 98% RH (Non-Condensing)
- Relay Output Configuration
- Fault Relay: NO & NC Contacts
- Fire Alarm Relay: NO & NC Contacts, Latching/Non-Latching, Switch Selectable
- Fire Verify Relay: NO & NC Contacts, Adjustable Time From 0 to 30 sec
- Relay Contact Ratings: 0.5A @120 VAC, 1.0A @24 VDC
- Mounting
- Swivel Bracket Assembly
- Spectral Sensitivity
- Ultraviolet: 185 to 260 Nanometers
- Visible: 400 to 700 Nanometers
- Wide Band Infrared: 0.7 to 3.5 micrometers
- Conduit Entries
- 3/4 in NPT
- Field of View
- From Cone of Vision: 120 deg
- From On Axis: 60 deg
Operating Characteristics
- Minimum Temperature
- -40˚C
Standards & Certifications
- Ingress Protection
- IP66
- NEMA Rating
- NEMA 4
Material Specifications
- Enclosure Material
- Copper-Free Powder Coated Aluminum
Electrical Specifications
- Power Requirement
- 24 VDC
- Power Consumption
- 68 mA Normal Operation (Relay Version)
- 75 mA Alarm Condition (Relay Version)
- 95 mA Alarm Condition (Analog Version)
Applications & Compatibility
- Application
- Aircraft Hangars
- Co-Generation Plants
- Gas Compressor Stations
- Gas Turbines & Power Plants
- Silane and Hydrogen Gas Storage
- Warehouses
Overview
- Brand
- Honeywell
- Honeywell
- Warranty
- 2 Years from Date of Shipping
Features
- Sub-Category
- Flame Detectors
- Features & Benefits
- Adjustable Detector Sensitivity
- Adjustable Detector Sensitivity
- Available SS4-A, SS4-AS and SS4-AUV
- Built-In Test For Optical “Through The Lens” Testing
- Built-In Test For Optical “Through The Lens” Testing
- Compatible with Standard Approved Fire Alarm Panels
- Compatible with Standard Approved Fire Alarm Panels
- Detects Hydrocarbon and Non-Hydrocarbon Fires
- Detects Hydrocarbon and Non-Hydrocarbon Fires
- Explosion-Proof Housing
- Explosion-Proof Housing
- False Alarm Immunity
- Microcomputer Based Algorithms: FirePic™, Snapshot™ and UV Plot
- Microprocessor Based Algorithms: FirePic™, Snapshot™ and Tri-Mode Plot™
- Multi-Spectrum Senses Energy in the UV, Vis and WideBand IR™
- Senses Solar-Blink Ultraviolet Band
- Time Programmable Alarm Verification
- Time Programmable Alarm Verification
- Utilizes Long-Life, Ruggedized UV Sensors
- Wide Field of View and Solar Blind
- Wide Field of View and Solar Blind
- Wide Temperature Range of Operation
- Wide Temperature Range of Operation
Dimensions & Weight
- Weight range
- Aluminum: 4 lbs
- Stainless Steel: 7.5 lbs
Technical Specifications
- Humidity Range
- 5 to 98% RH (Non-Condensing)
- Relay Output Configuration
- Fault Relay: NO & NC Contacts
- Fire Alarm Relay: NO & NC Contacts, Latching/Non-Latching, Switch Selectable
- Fire Verify Relay: NO & NC Contacts, Adjustable Time From 0 to 30 sec
- Relay Contact Ratings: 0.5A @120 VAC, 1.0A @24 VDC
- Mounting
- Swivel Bracket Assembly
- Spectral Sensitivity
- Ultraviolet: 185 to 260 Nanometers
- Visible: 400 to 700 Nanometers
- Wide Band Infrared: 0.7 to 3.5 micrometers
- Conduit Entries
- 3/4 in NPT
- Field of View
- From Cone of Vision: 120 deg
- From On Axis: 60 deg
Operating Characteristics
- Minimum Temperature
- -40˚C
Standards & Certifications
- Ingress Protection
- IP66
- NEMA Rating
- NEMA 4
Material Specifications
- Enclosure Material
- Copper-Free Powder Coated Aluminum
Electrical Specifications
- Power Requirement
- 24 VDC
- Power Consumption
- 68 mA Normal Operation (Relay Version)
- 75 mA Alarm Condition (Relay Version)
- 95 mA Alarm Condition (Analog Version)
Applications & Compatibility
- Application
- Aircraft Hangars
- Co-Generation Plants
- Gas Compressor Stations
- Gas Turbines & Power Plants
- Silane and Hydrogen Gas Storage
- Warehouses
- Brand : Honeywell|Honeywell
- Sub-Category : Flame Detectors
- Weight range : Aluminum: 4 lbs|Stainless Steel: 7.5 lbs
- Humidity Range : 5 to 98% RH (Non-Condensing)
- Minimum Temperature : -40˚C
- Features & Benefits : Adjustable Detector Sensitivity|Adjustable Detector Sensitivity|Available SS4-A, SS4-AS and SS4-AUV|Built-In Test For Optical “Through The Lens” Testing|Built-In Test For Optical “Through The Lens” Testing|Compatible with Standard Approved Fire Alarm Panels|Compatible with Standard Approved Fire Alarm Panels|Detects Hydrocarbon and Non-Hydrocarbon Fires|Detects Hydrocarbon and Non-Hydrocarbon Fires|Explosion-Proof Housing|Explosion-Proof Housing|False Alarm Immunity|Microcomputer Based Algorithms: FirePic™, Snapshot™ and UV Plot|Microprocessor Based Algorithms: FirePic™, Snapshot™ and Tri-Mode Plot™|Multi-Spectrum Senses Energy in the UV, Vis and WideBand IR™|Senses Solar-Blink Ultraviolet Band|Time Programmable Alarm Verification|Time Programmable Alarm Verification|Utilizes Long-Life, Ruggedized UV Sensors|Wide Field of View and Solar Blind|Wide Field of View and Solar Blind|Wide Temperature Range of Operation|Wide Temperature Range of Operation
- Relay Output Configuration : Fault Relay: NO & NC Contacts|Fire Alarm Relay: NO & NC Contacts, Latching/Non-Latching, Switch Selectable|Fire Verify Relay: NO & NC Contacts, Adjustable Time From 0 to 30 sec|Relay Contact Ratings: 0.5A @120 VAC, 1.0A @24 VDC
- Ingress Protection : IP66
- NEMA Rating : NEMA 4
- Mounting : Swivel Bracket Assembly
- Spectral Sensitivity : Ultraviolet: 185 to 260 Nanometers|Visible: 400 to 700 Nanometers|Wide Band Infrared: 0.7 to 3.5 micrometers
- Enclosure Material : Copper-Free Powder Coated Aluminum
- Power Requirement : 24 VDC
- Power Consumption : 68 mA Normal Operation (Relay Version)|75 mA Alarm Condition (Relay Version)|95 mA Alarm Condition (Analog Version)
- Conduit Entries : 3/4 in NPT
- Field of View : From Cone of Vision: 120 deg|From On Axis: 60 deg
- Application : Aircraft Hangars|Co-Generation Plants|Gas Compressor Stations|Gas Turbines & Power Plants|Silane and Hydrogen Gas Storage|Warehouses
- Warranty : 2 Years from Date of Shipping
Please sign in to access more documents.
Once signed in, you may be able to access additional documents for your account.
Manuals and Guides
Brochure
Certificate
Please sign in to view part numbers available for purchase based on your account Sign In