fixed gas controllers
Manning AirAlert 96d
Manning AirAlert 96d
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Acting as the nerve center of a modular gas detection network, this multichannel system provides continuous monitoring of up to 96 sensors.
Product Overview:
The Manning AirAlertTM 96d multichannel gas monitoring system is designed for installation and operational simplicity for continuous monitoring and control of toxic gases, combustible gases and Oxygen hazards.
The Manning AirAlert™ 96d can support up to 96 sensors and relay modules and provides unique at-a-glance system status and can be maintained with ease using the menu driven push button controls.
This easy to use system can be completely customized in an industrial or commercial application by using any combination of Honeywell Analytics sensors. The Manning AirAlert™ 96d has the potential to complete plant control systems by operating independently, interfacing with it to create a reliable stand-alone safety system.
Additional Features and Benefits:
Applications:
- Garage Ventilation Control
- IAQ Control
- Perimeter Monitoring
- Refrigerant Leak Detection Monitoring
- Zoned Valve Cut-off Control
96 Sensor Capacity:
- Supports up to 96 network devices
- Three distinct channels act as the nerve center of a modular gas detection network
Menu-Driven Program:
- Easily fine-tune applications ranging from minor operational sequences to reconfiguration of entire network
- Simple push-button program facilitates adjustments
Customizable:
- Supports any combination of Honeywell Analytics gas sensors, including NH3, CO2, H2, CO, Cl2, CFC’s, HCFC’s, HFC’s, CH4, O2, NO2, and more
- Field-programmable alarm levels for each sensor
- Zoning capability allows for up to 126 zones
Immediate At-a-Glance Status:
- 122 x 32 alphanumeric LCD display provides continuous information for the entire network
Automatic Datalogging Capability:
- Controller provides automatic datalogging within cast aluminum enclosure
- Sensor concentrations and alarms is recorded for analysis
Easy Installation:
- Cost is reduced by addressable RS-485 MODBUS communication protocol
- Installation requires only two pairs of wires to connect each gas sensors and relay modules to one of the controller’s three input channels
Centralized Information:
- Interface with or function individually with plant control
Features & Benefits:
- Simple push-button program facilitates adjustment
- Supports any combination of Honeywell Analytics gas sensors
- Immediate, at-a-glance status
Quick Specs:
- Supports up to 96 network devices
- Easily fine-tune applications ranging from minor operational sequences to reconfiguration of entire network
- Simple push-button program facilitates adjustments
- Supports any combination of Honeywell Analytics gas sensors, including NH3, CO2, H2, CO, Cl2, CFC’s, HCFC’s, HFC’s, CH4, O2, NO2, and more
- Zoning capability allows for up to 126 zones
- Immediate At-a-Glance Status
Brand
- Brand
- Honeywell
- Manning
Category
- Sub-Category
- Gas Detection Controllers
- Toxic and Combustible Gas Detector Network Platform
Dimension & Weight
- Weight range
- 5170.9 gram
Range
- Humidity Range
- 0 to 95% RH (Non-Condensing) percent
- Altitude Range
- Up to 3,000 m
Temperature
- Minimum Temperature
- -20
- Maximum Temperature
- 50
Alarm
- Alarm Included
- Yes
- Alarm Type
- Alphanumeric LCD Display
Datalogging
- Datalogging Capable
- Yes
Display
- Display Viewing Area
- 122 x 82 pixel
- Display Included
- Yes
- Display Readout
- Continuous Information for the Entire Network
- Display Type
- Graphic 122 x 82 pixel Alphanumeric Dot Matrix Backlit
Features & Benefits
- Features & Benefits
- Automatic Datalogging within Cast Aluminum Enclosure
- Easily Fine-Tune Applications Ranging from Minor Operational Sequences to Reconfiguration of Entire Network
- Installation Requires Only Two Pairs of Wires to Connect Each Gas Sensors and Relay Modules to One of the Controller’s Three Input Channels
- Simple Push-Button Program Facilitates Adjustments
- Supports up to 96 Network Devices
- Zoning Capability Allows for up to 126 Zones
Material
- Material
- Cast Aluminum
Port
- Communication Ports
- RS-485 Modbus Protocol
Relay
- Relay Output Configuration
- 4 DPDT Relays
- Relay Included
- Yes
Voltage & Current
- Operating Current
- 500 milliampere
Wireless
- Wireless Enabled
- Yes
Additional Specifications
- Signal Output Connection
- BACnet Output Only
- Number of Relay Outputs
- 4
- Output Signal Type
- BACnet Output
- Number of Contacts
- 96
- Visual Indicators
- Alarm: Red
- Fault: Yellow
- High Alarm: Red
- Power On: Green
- Rx: Green (Blinks when in Use)
- Tx: Amber (Blinks when in Use)
- Warn Red (Blinks Upon an Event)
- NEMA Rating
- NEMA 4x
- Combustible
- Yes
- Shielded
- Yes
- Gas Type
- Supports Any Combination of Honeywell Analytics Gas Sensors Including NH3, CO2, H2, CO, Cl2, CFC’s, HCFC’s, HFC’s, CH4, O2, NO2 and More
Dimensions & Weight
- Size
- 241.3 mm x 355.6 mm x 88.9 mm
Electrical Specifications
- Power Requirement
- 24V DC, 500 mA (18 to 36V DC)
Features
- Series Name
- AirAlertTM 96d
Applications & Compatibility
- Application
- Garage Ventilation Control
- IAQ Control
- Perimeter Monitoring
- Refrigerant Leak Detection Monitoring
- Zoned Valve Cut-off Control
Technical Specifications
- Time Delay
- 0, 30, and 45 sec
- 1 to 99 min Before and After Alarm
- Zoning
- Up to 126
Others
- Industry
- Commercial Buildings
Brand
- Brand
- Honeywell
- Manning
Category
- Sub-Category
- Gas Detection Controllers
- Toxic and Combustible Gas Detector Network Platform
Dimension & Weight
- Weight range
- 5170.9 gram
Range
- Humidity Range
- 0 to 95% RH (Non-Condensing) percent
- Altitude Range
- Up to 3,000 m
Temperature
- Minimum Temperature
- -20
- Maximum Temperature
- 50
Alarm
- Alarm Included
- Yes
- Alarm Type
- Alphanumeric LCD Display
Datalogging
- Datalogging Capable
- Yes
Display
- Display Viewing Area
- 122 x 82 pixel
- Display Included
- Yes
- Display Readout
- Continuous Information for the Entire Network
- Display Type
- Graphic 122 x 82 pixel Alphanumeric Dot Matrix Backlit
Features & Benefits
- Features & Benefits
- Automatic Datalogging within Cast Aluminum Enclosure
- Easily Fine-Tune Applications Ranging from Minor Operational Sequences to Reconfiguration of Entire Network
- Installation Requires Only Two Pairs of Wires to Connect Each Gas Sensors and Relay Modules to One of the Controller’s Three Input Channels
- Simple Push-Button Program Facilitates Adjustments
- Supports up to 96 Network Devices
- Zoning Capability Allows for up to 126 Zones
Material
- Material
- Cast Aluminum
Port
- Communication Ports
- RS-485 Modbus Protocol
Relay
- Relay Output Configuration
- 4 DPDT Relays
- Relay Included
- Yes
Voltage & Current
- Operating Current
- 500 milliampere
Wireless
- Wireless Enabled
- Yes
Additional Specifications
- Signal Output Connection
- BACnet Output Only
- Number of Relay Outputs
- 4
- Output Signal Type
- BACnet Output
- Number of Contacts
- 96
- Visual Indicators
- Alarm: Red
- Fault: Yellow
- High Alarm: Red
- Power On: Green
- Rx: Green (Blinks when in Use)
- Tx: Amber (Blinks when in Use)
- Warn Red (Blinks Upon an Event)
- NEMA Rating
- NEMA 4x
- Combustible
- Yes
- Shielded
- Yes
- Gas Type
- Supports Any Combination of Honeywell Analytics Gas Sensors Including NH3, CO2, H2, CO, Cl2, CFC’s, HCFC’s, HFC’s, CH4, O2, NO2 and More
Dimensions & Weight
- Size
- 241.3 mm x 355.6 mm x 88.9 mm
Electrical Specifications
- Power Requirement
- 24V DC, 500 mA (18 to 36V DC)
Features
- Series Name
- AirAlertTM 96d
Applications & Compatibility
- Application
- Garage Ventilation Control
- IAQ Control
- Perimeter Monitoring
- Refrigerant Leak Detection Monitoring
- Zoned Valve Cut-off Control
Technical Specifications
- Time Delay
- 0, 30, and 45 sec
- 1 to 99 min Before and After Alarm
- Zoning
- Up to 126
Others
- Industry
- Commercial Buildings
- Brand : Honeywell|Manning
- Sub-Category : Gas Detection Controllers|Toxic and Combustible Gas Detector Network Platform
- Weight range : 5170.9 gram
- Humidity Range : 0 to 95% RH (Non-Condensing) percent
- Altitude Range : Up to 3,000 m
- Minimum Temperature : -20
- Maximum Temperature : 50
- Alarm Included : Yes
- Alarm Type : Alphanumeric LCD Display
- Datalogging Capable : Yes
- Display Viewing Area : 122 x 82 pixel
- Display Included : Yes
- Display Readout : Continuous Information for the Entire Network
- Display Type : Graphic 122 x 82 pixel Alphanumeric Dot Matrix Backlit
- Features & Benefits : Automatic Datalogging within Cast Aluminum Enclosure|Easily Fine-Tune Applications Ranging from Minor Operational Sequences to Reconfiguration of Entire Network|Installation Requires Only Two Pairs of Wires to Connect Each Gas Sensors and Relay Modules to One of the Controller’s Three Input Channels|Simple Push-Button Program Facilitates Adjustments|Supports up to 96 Network Devices|Zoning Capability Allows for up to 126 Zones
- Material : Cast Aluminum
- Communication Ports : RS-485 Modbus Protocol
- Relay Output Configuration : 4 DPDT Relays
- Relay Included : Yes
- Operating Current : 500 milliampere
- Wireless Enabled : Yes
- Signal Output Connection : BACnet Output Only
- Number of Relay Outputs : 4
- Output Signal Type : BACnet Output
- Number of Contacts : 96
- Visual Indicators : Alarm: Red|Fault: Yellow|High Alarm: Red|Power On: Green|Rx: Green (Blinks when in Use)|Tx: Amber (Blinks when in Use)|Warn Red (Blinks Upon an Event)
- NEMA Rating : NEMA 4x
- Combustible : Yes
- Shielded : Yes
- Gas Type : Supports Any Combination of Honeywell Analytics Gas Sensors Including NH3, CO2, H2, CO, Cl2, CFC’s, HCFC’s, HFC’s, CH4, O2, NO2 and More
- Size : 241.3 mm x 355.6 mm x 88.9 mm
- Power Requirement : 24V DC, 500 mA (18 to 36V DC)
- Series Name : AirAlertTM 96d
- Application : Garage Ventilation Control|IAQ Control|Perimeter Monitoring|Refrigerant Leak Detection Monitoring|Zoned Valve Cut-off Control
- Time Delay : 0, 30, and 45 sec|1 to 99 min Before and After Alarm
- Industry : Commercial Buildings
- Zoning : Up to 126
Please sign in to access more documents.
Once signed in, you may be able to access additional documents for your account.
Data Sheet
Manuals and Guides
Technical Note
Please sign in to view part numbers available for purchase based on your account Sign In