Fixed Flame Detectors
FS24X Flame Detector
Triple IR flame detector using Honeywell’s WideBand IR™ infrared technology to detect hydrocarbon fires
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Product Overview:
The FS24X is the latest generation high technology Multi-Spectrum Triple IR (IR/IR/IR/Visible) Flame Detector, which is part of our FSX family of advanced technology Electro-Optical fire detectors. Using our patented* WideBand IR™, WideBand 4.3 micron IR™, and Visible detection technology, the FS24X is a quantum leap in flame detection. Sophisticated software algorithms and dual microprocessors ensure that the FS24X has the highest fire detection performance combined with optimal false alarm rejection.
The WideBand IR™ Infrared technology using high-speed solid-state Quantum sensors allows detection of all types of fires, hydrocarbon and non-hydrocarbon, in all weather conditions. If the detector’s signal is blocked by ordinary window glass, the patented WideBand IR sensors will still alarm to the fire but at a reduced sensitivity and slower response time.
Dual microprocessors provide a high level of fail-safe operation combined with fast and reliable performance. The Master Microprocessor performs high-speed digital sampling and signal-processing calculations: while the slave microprocessor handles various sensor data, performs communications, self-diagnostics and provides interface versatility: and additional memory for storing Event Log and FirePic™ data.
The FSX family of detectors feature our patented* FirePic data storage and information retrieval facility. FirePic™ records pre-fire data, which can be recovered from the Detector’s non-volatile flash memory for post fire analysis and postulation of the fire cause. Additionally, unique Real-Time Graphing (RTG™) allows viewing of the data that the Detector actually sees. A combination of outputs makes the FS24X a truly versatile detector for today’s demanding industrial requirements.
The FS24X Flame Detector has a detection range greater than 200 feet (Very High Sensitivity setting) for the detection of a one square-foot Heptane reference fire and has a cone of vision far greater in volumetric coverage than any other Multi-Spectrum IR Detector. This means fewer detectors can be used as compared to other manufacturers’ detectors.
Additional Features and Benefits:
Features:
- Patented* WideBand IR™ Technology
- Patented* Electronic Frequency Analysis™
- Visible Sensor for optimum false alarm rejection
- Selectable detection sensitivities
- Field-of-View: 110° full 100% cone-of-vision (90° full 100% cone-of-vision model also available)
- Dual microprocessors for reliable performance
- Real-time clock for accurate time dating of events
- FirePic™ — pre-fire event data storage
- Event log with date and time stamp
- RS-485 ModBus communication
- Non-Isolated 4-20 mA Analog output (sink or source)
- Alarm, Fault and Fire Verification relays
- Automatic optical path and electronic self-test
- Widest operating temperature range
- Patented* Electronics Module for components protection with easy plug-in terminations and field installation
- Two ¾” NPT OR 25mm conduit entries
- Low power consumption
- High RFI and EMI immunity
- FM, ATEX, CE mark approvals
- Meets SIL 2 requirements
- Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
- User selectable outputs
- Optimal false alarm rejection for all environmental conditions
- Minimal maintenance for trouble-free operation
- PC software and Interface Module (FSIM) for fault diagnostics, real-time graphics (RTGs), and downloading of FirePics™ and event log
- Suitable for a wide variety of applications
- Easy electronics module replacement
- Test lamps for manual testing.
- Detects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions
- User selection outputs
- Optimal false alarm rejection
- Sensitivity: Very high, high, medium and low - switch selectable
- Operating voltage: 24 VDC nominal (18-32 VDC) - regulated
- Humidity range: 5 to 98% relative humidity, non-condensing
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Overview
- Brand
- Honeywell
- Warranty
- 3 Years from Date of Shipment
Features
- Sub-Category
- Flame Detectors
- Flame Detectors
- Alarm Included
- Yes
- Features & Benefits
- Detects Hydrocarbon and Non-Hydrocarbon Fires
- Diagnostics, Real-Time Graphics (RTGs)
- Downloading of FirePics™ and Event Log
- Easy Electronics Module Replacement
- Minimal Maintenance for Trouble-Free Operation
- Optimal False Alarm Rejection
- PC Software and Interface Module (FSIM) for fault
- Suitable for a Wide Variety of Applications
- Test Lamps for Manual Testing
- User Selectable Outputs
- Wide Operating Temperature Range
- Relay Included
- Yes
- Warnings & Restrictions
- Potential Electrostatic Charge, Wipe Enclosure Only with a Damp Cloth
- Wireless Technology
- WideBand IR™
- Visual Indicators
- Green LED: Power
- Red LED: Alarm
- Yellow: Fault
- Vibration
- Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
Dimensions & Weight
- Mounting Hole Diameter
- 0.25
- Overall Height
- 124.2 mm
- Overall Width
- 110.4 mm
- Weight range
- Aluminum: 1.6 kg (3.6 lbs)
- Stainless Steel: 3.2 kg (7 lbs)
- Overall Depth
- 156.4 mm
Technical Specifications
- Output Signal Range
- 4 to 20 mA
- Humidity Range
- 5 to 98% RH (Non-Condensing)
- Altitude Range
- 200ft (60m)
- Analog Output Signal Type
- mA
- Number of Analog Outputs
- 1
- Relay Circuit Resting Configuration
- NO, NC, COM
- Relay Output Configuration
- SPDT
- Relay Activation Settings
- Fire Alarm(Relay 1), Fault (Relay2), Auxilary (Relay3)
- Relay Rated Load
- 1A @24V DC
- Sensor Mechanism
- Infrared Sensor
- Sensing Method
- Infrared
- Maximum Analog Input Resistance
- 400
- Default Relay Activation
- Alarm Relay (Relay 1), Auxiliary Relay V (Relay 2), Fault Relay (Relay 3)
- Number of Relay Outputs
- 3
- Output Signal Type
- mA
- Mounting
- Swivel Bracket Assembly
- Spectral Sensitivity
- Near Band IR: 0.7 to 1.1 microns
- Visible: 400 to 700 Nanometers
- Wide Band IR: 1.1 to 3.0 microns
- Wide Band IR: 3.0 to 5.0 microns
- Loop Resistance
- 50 to 400 Ohms
- Conduit Entries
- (2) 3/4 in NPT
- Field of View
- FS24X-2: 110° Cone of Vision, ± 55° From On Axis
- FS24X-9: 90° Cone of Vision, ± 45° From On Axis
- Communication
- HART®, Optional Plug-in Module (Not Available on EN54-10 Units)
- RS485, FireBus II
- RS485, ModBus Protocol
- Sensitivity
- Selectable Switch: Very High (200ft), High (150ft), Medium (100ft) and Low (50ft)
- Wiring
- Shielded: 2.5 sq.mm (14 AWG) to 0.326 sq.mm (22 AWG)
Electrical Specifications
- Analog Output Signal Current
- 4 to 20 mA
- Maximum Operating Current
- 60 mA
- Operating Current
- 60
- Power Requirement
- 18 to 32 VDC
- Power Consumption
- Alarm: 106 mA @24 VDC Nominal
- Heater will Turn on at -17°C
- Heater: 155 mA (Additional)
- Operating: 56 mA @24 VDC Nominal
- Operating Voltage
- 24 VDC
Standards & Certifications
- Certifications - Performance
- EN54-10 Sensitivity
- Certifications - Regional
- Global
- Certifications - Other
- ATEX/IECEx: Ex II 2 G Ex db IIC T4 (Ta: -40 to +110°C), T5 (Ta: -40 to +75°C), T6 (Ta: -40 to +60°C), II 2 D Ex tb IIIC T135°C (FS24X-2, 110° Field of View)
- ATEX/IECEx: Ex II 2 G Ex db IIC T4 (Ta: -60 to +110°C), T5 (Ta: -60 to +75°C), T6 (Ta: -60 to +60°C), II 2 D Ex tb IIIC T135°C (FS24X-9, 90° Field of View)
- CE: EN6100-6-4 & EN50130-4
- FM: Class I, Div. 1 & 2, Groups B, C, & D; Class II, Div. 1 & 2, Groups E, F, & G; Class III
- INMETRO, CU-TR
- NEMA Rating
- NEMA 4, 4X
Operating Characteristics
- Storage Temperature
- -55 to +110°C
Material Specifications
- Enclosure Material
- 316 Stainless Steel
- Copper-Free Powder Coated Aluminum
Applications & Compatibility
- Application
- Aircraft Hangars
- Chemical Production, Storage and Loading Facilities
- Crude Oil and Gasoline Storage and Tank Farms
- Ethanol, Methanol and IPA Production and Storage
- LNG/LPG Loading and Unloading Facilities
- Natural Gas and CNG Plants
- Off-Shore Platforms
- Oil and Gas Pipelines and Pumping Stations
- Paint and Solvent Storage
- Power Plants
- Refineries and Oil Production Facilities
- Turbine/Compressor Enclosures
Others
- Industry
- Energy
- Government & Public Sector
- Logistics & Warehouses
Overview
- Brand
- Honeywell
- Warranty
- 3 Years from Date of Shipment
Features
- Sub-Category
- Flame Detectors
- Flame Detectors
- Alarm Included
- Yes
- Features & Benefits
- Detects Hydrocarbon and Non-Hydrocarbon Fires
- Diagnostics, Real-Time Graphics (RTGs)
- Downloading of FirePics™ and Event Log
- Easy Electronics Module Replacement
- Minimal Maintenance for Trouble-Free Operation
- Optimal False Alarm Rejection
- PC Software and Interface Module (FSIM) for fault
- Suitable for a Wide Variety of Applications
- Test Lamps for Manual Testing
- User Selectable Outputs
- Wide Operating Temperature Range
- Relay Included
- Yes
- Warnings & Restrictions
- Potential Electrostatic Charge, Wipe Enclosure Only with a Damp Cloth
- Wireless Technology
- WideBand IR™
- Visual Indicators
- Green LED: Power
- Red LED: Alarm
- Yellow: Fault
- Vibration
- Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
Dimensions & Weight
- Mounting Hole Diameter
- 0.25
- Overall Height
- 124.2 mm
- Overall Width
- 110.4 mm
- Weight range
- Aluminum: 1.6 kg (3.6 lbs)
- Stainless Steel: 3.2 kg (7 lbs)
- Overall Depth
- 156.4 mm
Technical Specifications
- Output Signal Range
- 4 to 20 mA
- Humidity Range
- 5 to 98% RH (Non-Condensing)
- Altitude Range
- 200ft (60m)
- Analog Output Signal Type
- mA
- Number of Analog Outputs
- 1
- Relay Circuit Resting Configuration
- NO, NC, COM
- Relay Output Configuration
- SPDT
- Relay Activation Settings
- Fire Alarm(Relay 1), Fault (Relay2), Auxilary (Relay3)
- Relay Rated Load
- 1A @24V DC
- Sensor Mechanism
- Infrared Sensor
- Sensing Method
- Infrared
- Maximum Analog Input Resistance
- 400
- Default Relay Activation
- Alarm Relay (Relay 1), Auxiliary Relay V (Relay 2), Fault Relay (Relay 3)
- Number of Relay Outputs
- 3
- Output Signal Type
- mA
- Mounting
- Swivel Bracket Assembly
- Spectral Sensitivity
- Near Band IR: 0.7 to 1.1 microns
- Visible: 400 to 700 Nanometers
- Wide Band IR: 1.1 to 3.0 microns
- Wide Band IR: 3.0 to 5.0 microns
- Loop Resistance
- 50 to 400 Ohms
- Conduit Entries
- (2) 3/4 in NPT
- Field of View
- FS24X-2: 110° Cone of Vision, ± 55° From On Axis
- FS24X-9: 90° Cone of Vision, ± 45° From On Axis
- Communication
- HART®, Optional Plug-in Module (Not Available on EN54-10 Units)
- RS485, FireBus II
- RS485, ModBus Protocol
- Sensitivity
- Selectable Switch: Very High (200ft), High (150ft), Medium (100ft) and Low (50ft)
- Wiring
- Shielded: 2.5 sq.mm (14 AWG) to 0.326 sq.mm (22 AWG)
Electrical Specifications
- Analog Output Signal Current
- 4 to 20 mA
- Maximum Operating Current
- 60 mA
- Operating Current
- 60
- Power Requirement
- 18 to 32 VDC
- Power Consumption
- Alarm: 106 mA @24 VDC Nominal
- Heater will Turn on at -17°C
- Heater: 155 mA (Additional)
- Operating: 56 mA @24 VDC Nominal
- Operating Voltage
- 24 VDC
Standards & Certifications
- Certifications - Performance
- EN54-10 Sensitivity
- Certifications - Regional
- Global
- Certifications - Other
- ATEX/IECEx: Ex II 2 G Ex db IIC T4 (Ta: -40 to +110°C), T5 (Ta: -40 to +75°C), T6 (Ta: -40 to +60°C), II 2 D Ex tb IIIC T135°C (FS24X-2, 110° Field of View)
- ATEX/IECEx: Ex II 2 G Ex db IIC T4 (Ta: -60 to +110°C), T5 (Ta: -60 to +75°C), T6 (Ta: -60 to +60°C), II 2 D Ex tb IIIC T135°C (FS24X-9, 90° Field of View)
- CE: EN6100-6-4 & EN50130-4
- FM: Class I, Div. 1 & 2, Groups B, C, & D; Class II, Div. 1 & 2, Groups E, F, & G; Class III
- INMETRO, CU-TR
- NEMA Rating
- NEMA 4, 4X
Operating Characteristics
- Storage Temperature
- -55 to +110°C
Material Specifications
- Enclosure Material
- 316 Stainless Steel
- Copper-Free Powder Coated Aluminum
Applications & Compatibility
- Application
- Aircraft Hangars
- Chemical Production, Storage and Loading Facilities
- Crude Oil and Gasoline Storage and Tank Farms
- Ethanol, Methanol and IPA Production and Storage
- LNG/LPG Loading and Unloading Facilities
- Natural Gas and CNG Plants
- Off-Shore Platforms
- Oil and Gas Pipelines and Pumping Stations
- Paint and Solvent Storage
- Power Plants
- Refineries and Oil Production Facilities
- Turbine/Compressor Enclosures
Others
- Industry
- Energy
- Government & Public Sector
- Logistics & Warehouses
- Brand : Honeywell
- Sub-Category : Flame Detectors|Flame Detectors
- Mounting Hole Diameter : 0.25
- Overall Height : 124.2 mm
- Overall Width : 110.4 mm
- Weight range : Aluminum: 1.6 kg (3.6 lbs)|Stainless Steel: 3.2 kg (7 lbs)
- Output Signal Range : 4 to 20 mA
- Humidity Range : 5 to 98% RH (Non-Condensing)
- Altitude Range : 200ft (60m)
- Alarm Included : Yes
- Analog Output Signal Current : 4 to 20 mA
- Analog Output Signal Type : mA
- Number of Analog Outputs : 1
- Certifications - Performance : EN54-10 Sensitivity
- Certifications - Regional : Global
- Certifications - Other : ATEX/IECEx: Ex II 2 G Ex db IIC T4 (Ta: -40 to +110°C), T5 (Ta: -40 to +75°C), T6 (Ta: -40 to +60°C), II 2 D Ex tb IIIC T135°C (FS24X-2, 110° Field of View)|ATEX/IECEx: Ex II 2 G Ex db IIC T4 (Ta: -60 to +110°C), T5 (Ta: -60 to +75°C), T6 (Ta: -60 to +60°C), II 2 D Ex tb IIIC T135°C (FS24X-9, 90° Field of View)|CE: EN6100-6-4 & EN50130-4|FM: Class I, Div. 1 & 2, Groups B, C, & D; Class II, Div. 1 & 2, Groups E, F, & G; Class III|INMETRO, CU-TR
- Features & Benefits : Detects Hydrocarbon and Non-Hydrocarbon Fires|Diagnostics, Real-Time Graphics (RTGs)|Downloading of FirePics™ and Event Log|Easy Electronics Module Replacement|Minimal Maintenance for Trouble-Free Operation|Optimal False Alarm Rejection|PC Software and Interface Module (FSIM) for fault|Suitable for a Wide Variety of Applications|Test Lamps for Manual Testing|User Selectable Outputs|Wide Operating Temperature Range
- Relay Circuit Resting Configuration : NO, NC, COM
- Relay Output Configuration : SPDT
- Relay Activation Settings : Fire Alarm(Relay 1), Fault (Relay2), Auxilary (Relay3)
- Relay Rated Load : 1A @24V DC
- Relay Included : Yes
- Sensor Mechanism : Infrared Sensor
- Sensing Method : Infrared
- Maximum Analog Input Resistance : 400
- Maximum Operating Current : 60 mA
- Operating Current : 60
- Warnings & Restrictions : Potential Electrostatic Charge, Wipe Enclosure Only with a Damp Cloth
- Wireless Technology : WideBand IR™
- Default Relay Activation : Alarm Relay (Relay 1), Auxiliary Relay V (Relay 2), Fault Relay (Relay 3)
- Number of Relay Outputs : 3
- Output Signal Type : mA
- Visual Indicators : Green LED: Power|Red LED: Alarm|Yellow: Fault
- NEMA Rating : NEMA 4, 4X
- Mounting : Swivel Bracket Assembly
- Spectral Sensitivity : Near Band IR: 0.7 to 1.1 microns|Visible: 400 to 700 Nanometers|Wide Band IR: 1.1 to 3.0 microns|Wide Band IR: 3.0 to 5.0 microns
- Storage Temperature : -55 to +110°C
- Enclosure Material : 316 Stainless Steel|Copper-Free Powder Coated Aluminum
- Power Requirement : 18 to 32 VDC
- Power Consumption : Alarm: 106 mA @24 VDC Nominal|Heater will Turn on at -17°C|Heater: 155 mA (Additional)|Operating: 56 mA @24 VDC Nominal
- Operating Voltage : 24 VDC
- Loop Resistance : 50 to 400 Ohms
- Conduit Entries : (2) 3/4 in NPT
- Overall Depth : 156.4 mm
- Field of View : FS24X-2: 110° Cone of Vision, ± 55° From On Axis|FS24X-9: 90° Cone of Vision, ± 45° From On Axis
- Communication : HART®, Optional Plug-in Module (Not Available on EN54-10 Units)|RS485, FireBus II|RS485, ModBus Protocol
- Sensitivity : Selectable Switch: Very High (200ft), High (150ft), Medium (100ft) and Low (50ft)
- Application : Aircraft Hangars|Chemical Production, Storage and Loading Facilities|Crude Oil and Gasoline Storage and Tank Farms|Ethanol, Methanol and IPA Production and Storage|LNG/LPG Loading and Unloading Facilities|Natural Gas and CNG Plants|Off-Shore Platforms|Oil and Gas Pipelines and Pumping Stations|Paint and Solvent Storage|Power Plants|Refineries and Oil Production Facilities|Turbine/Compressor Enclosures
- Vibration : Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12
- Warranty : 3 Years from Date of Shipment
- Industry : Energy|Government & Public Sector|Logistics & Warehouses
- Wiring : Shielded: 2.5 sq.mm (14 AWG) to 0.326 sq.mm (22 AWG)
Data Sheet
Manuals and Guides
Firmware
Brochure
Technical Note
Certificate
Others
Please sign in to view part numbers available for purchase based on your account Sign In