Portable Calibration Stations
MicroDock II Dock Calibration System
MicroDock II Dock Calibration System
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
The most cost effective way to manage the calibration and bump testing of Honeywell Analytics portable gas detectors.
Product Overview
The most cost effective way to manage the calibration and bump testing of Honeywell Analytics portable gas detectors is through the MicroDock II automated test and calibration system. Fully portable and easily expandable, the MicroDock II requires no computer and provides simultaneous management of up to six modules. Minimize expenses and maximize productivity with the MicroDock II.
Features & Benefits:
- Quick and easy compliance - automatically maintain accurate records
- Automatic bump testing, calibration, record keeping and charging
- One base station with one AC outlet supports up to six modules to suit your application
- Verifies proper performance of detectors
- Reduces maintenance costs
- Device management with Honeywell Safety Suite
Quick Specs:
- Size 8.3 x 10.4 x 3.2 in. / 21.2 x 26.3 x 8.2 cm (base station plus one docking module)
- Power supply 6V wall adaptor or four C-cell batteries
- Real-time clock provides time and date stamp for “last calibration” and “last bump test” data
- Data storage Automatic (instrument and base station)
- MultiMediaCard data storage system
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Brand
- Brand
- BW
- Honeywell BW™
Category
- Sub-Category
- Docks
- Docks
Dimension & Weight
- Overall Width
- 264.16 millimetre
- Overall Height
- 3.2 inch
Battery & Charging
- Batteries Required
- Four C-Cell Batteries
Certifications
- Standards
- Ordinary Location Approved C22.2 No. 61010 European Conformity
Features & Benefits
- Features & Benefits
- Add Extra Self-Contained Docking Modules to System via Simple Plug-in Connections - No External Pressure Transducers or Gas Lines Needed
- Automatically Verifies Performance of Audible and Visual Alarms
- Device Management with Honeywell Safety Suite
- Entirely Self-Contained with No Computer Required
- Fully Automatic Hands-Free Calibration and Functional Bump Testing
- Fully Customizable
- Lightweight and Fully Portable with Optional Wall Mount
- Multiple MicroDock II Systems can be Connected via a LAN
- One Base Station with One AC Outlet Supports up to Six Modules to Suit Your Application
- Operates via 6V Line Power or a Set of Four C-Cell Batteries
- Quick and Easy Compliance - Automatically Maintain Accurate Records
- Record Keeping and Charging
- Reduces Maintenance Costs
- Simple and Accurate Record Keeping and Fleet Management
- Stores and Updates Calibration Records in the MicroDock II as well as in Datalogging Instruments
- Verifies Proper Performance of Detectors
Flow Rate
- Flow Rate
- 300 millilitre per minute
Options
- User Options
- One touch bump-test initiation
- Real-Time Clock
- Provides Time and Date Stamp for “Last Calibration” and “Last Bump Test” Data
- Options & Accessories
- Cal Gas Wall Mount
- Demand Flow Regulator
- MicroDock II Portable System Kit
- Network USB
- One Touch Bump-Test Initiation
- Languages
- English, French, German, Spanish and Portuguese
- Includes
- Includes Fleet Manager II Software for Easy Data Analysis
Warranty
- Warranty
- 2 Years
- Full two year warranty
Wireless
- Wireless Technology
- Direct cable (RJ-45 10/100 Base T port)
Additional Specifications
- Power Supply
- 6V Wall Adaptor or Four C-Cell Batteries
- 6V wall adaptor or four C-cell batteries
- Data Storage Capacity
- 128
- 128 megabyte
- 128 MB
Standards & Certifications
- Ratings
- This Device Complies with the FCC Part 15 and ICES-003 Canadian EMI Requirements
Configuration
- Networking
- Direct Cable (RJ-45 10/100 Base T port)
- Communication
- Infrared Communication between Docking Module and Detector
Dimensions & Weight
- Dimension
- H: 3.2 in W: 10.4 in L: 8.3 in
Applicability
- Compatible Detectors
- GasAlert Extreme
- GasAlertMicro 5 Series
- GasAlertQuattro
- Honeywell BW™ Max XT II
- Honeywell BW™ MicroClip Series
Others
- Weight
- 0.97 kilogram
- 2.15 US Pound
Brand
- Brand
- BW
- Honeywell BW™
Category
- Sub-Category
- Docks
- Docks
Dimension & Weight
- Overall Width
- 264.16 millimetre
- Overall Height
- 3.2 inch
Battery & Charging
- Batteries Required
- Four C-Cell Batteries
Certifications
- Standards
- Ordinary Location Approved C22.2 No. 61010 European Conformity
Features & Benefits
- Features & Benefits
- Add Extra Self-Contained Docking Modules to System via Simple Plug-in Connections - No External Pressure Transducers or Gas Lines Needed
- Automatically Verifies Performance of Audible and Visual Alarms
- Device Management with Honeywell Safety Suite
- Entirely Self-Contained with No Computer Required
- Fully Automatic Hands-Free Calibration and Functional Bump Testing
- Fully Customizable
- Lightweight and Fully Portable with Optional Wall Mount
- Multiple MicroDock II Systems can be Connected via a LAN
- One Base Station with One AC Outlet Supports up to Six Modules to Suit Your Application
- Operates via 6V Line Power or a Set of Four C-Cell Batteries
- Quick and Easy Compliance - Automatically Maintain Accurate Records
- Record Keeping and Charging
- Reduces Maintenance Costs
- Simple and Accurate Record Keeping and Fleet Management
- Stores and Updates Calibration Records in the MicroDock II as well as in Datalogging Instruments
- Verifies Proper Performance of Detectors
Flow Rate
- Flow Rate
- 300 millilitre per minute
Options
- User Options
- One touch bump-test initiation
- Real-Time Clock
- Provides Time and Date Stamp for “Last Calibration” and “Last Bump Test” Data
- Options & Accessories
- Cal Gas Wall Mount
- Demand Flow Regulator
- MicroDock II Portable System Kit
- Network USB
- One Touch Bump-Test Initiation
- Languages
- English, French, German, Spanish and Portuguese
- Includes
- Includes Fleet Manager II Software for Easy Data Analysis
Warranty
- Warranty
- 2 Years
- Full two year warranty
Wireless
- Wireless Technology
- Direct cable (RJ-45 10/100 Base T port)
Additional Specifications
- Power Supply
- 6V Wall Adaptor or Four C-Cell Batteries
- 6V wall adaptor or four C-cell batteries
- Data Storage Capacity
- 128
- 128 megabyte
- 128 MB
Standards & Certifications
- Ratings
- This Device Complies with the FCC Part 15 and ICES-003 Canadian EMI Requirements
Configuration
- Networking
- Direct Cable (RJ-45 10/100 Base T port)
- Communication
- Infrared Communication between Docking Module and Detector
Dimensions & Weight
- Dimension
- H: 3.2 in W: 10.4 in L: 8.3 in
Applicability
- Compatible Detectors
- GasAlert Extreme
- GasAlertMicro 5 Series
- GasAlertQuattro
- Honeywell BW™ Max XT II
- Honeywell BW™ MicroClip Series
Others
- Weight
- 0.97 kilogram
- 2.15 US Pound
- Brand : BW|Honeywell BW™
- Weight : 0.97 kilogram|2.15 US Pound
- Sub-Category : Docks|Docks
- Overall Width : 264.16 millimetre
- Overall Height : 3.2 inch
- Batteries Required : Four C-Cell Batteries
- Standards : Ordinary Location Approved C22.2 No. 61010 European Conformity
- Features & Benefits : Add Extra Self-Contained Docking Modules to System via Simple Plug-in Connections - No External Pressure Transducers or Gas Lines Needed|Automatically Verifies Performance of Audible and Visual Alarms|Device Management with Honeywell Safety Suite|Entirely Self-Contained with No Computer Required|Fully Automatic Hands-Free Calibration and Functional Bump Testing|Fully Customizable|Lightweight and Fully Portable with Optional Wall Mount|Multiple MicroDock II Systems can be Connected via a LAN|One Base Station with One AC Outlet Supports up to Six Modules to Suit Your Application|Operates via 6V Line Power or a Set of Four C-Cell Batteries|Quick and Easy Compliance - Automatically Maintain Accurate Records|Record Keeping and Charging|Reduces Maintenance Costs|Simple and Accurate Record Keeping and Fleet Management|Stores and Updates Calibration Records in the MicroDock II as well as in Datalogging Instruments|Verifies Proper Performance of Detectors
- Flow Rate : 300 millilitre per minute
- User Options : One touch bump-test initiation
- Warranty : 2 Years|Full two year warranty
- Wireless Technology : Direct cable (RJ-45 10/100 Base T port)
- Power Supply : 6V Wall Adaptor or Four C-Cell Batteries|6V wall adaptor or four C-cell batteries
- Data Storage Capacity : 128|128 megabyte|128 MB
- Real-Time Clock : Provides Time and Date Stamp for “Last Calibration” and “Last Bump Test” Data
- Ratings : This Device Complies with the FCC Part 15 and ICES-003 Canadian EMI Requirements
- Options & Accessories : Cal Gas Wall Mount|Demand Flow Regulator|MicroDock II Portable System Kit|Network USB|One Touch Bump-Test Initiation
- Networking : Direct Cable (RJ-45 10/100 Base T port)
- Languages : English, French, German, Spanish and Portuguese
- Includes : Includes Fleet Manager II Software for Easy Data Analysis
- Dimension : H: 3.2 in W: 10.4 in L: 8.3 in
- Compatible Detectors : GasAlert Extreme|GasAlertMicro 5 Series|GasAlertQuattro|Honeywell BW™ Max XT II|Honeywell BW™ MicroClip Series
- Communication : Infrared Communication between Docking Module and Detector
Data Sheet
Manuals and Guides
Certificate
Others
Please sign in to view part numbers available for purchase based on your account Sign In
Please sign in to view part numbers available for purchase based on your account Sign In