Products
Products
Part Numbers
General Content
/content/sps/gb/en/search-results.html

Photoionization Detectors (PID)

UltraRAE 3000 +

The most advanced wireless handheld VOC monitor with parts per million measurement

Overview
UltraRAE3000

The UltraRAE 3000 is the most advanced Compound-Specific Monitor on the market. Its Photoionization Detector’s (PID)extended range of 0.01 to 10,000 ppm in VOC mode and 10 ppb to 200 ppm in benzene-specific mode makes it an ideal instrument for applications, from entry pre-screening during refinery and plant maintenance to hazardous material response, marine spill response and refinery down-stream monitoring.

  • Dual detection mode for total benzene exposure assessment: 60-second snapshot or 15-minute STEL measurement
  • High sensitivity to benzene (as low as 10 ppb) provides a lower detection range for future benzene exposure limits
  • Lower risk of false alarms through advanced speciation method
  • Total VOC measurement mode with extended range of 0.05 to 10,000 ppm

Key Features:

  • Proven PID technology
  • 3-second response in VOC mode or 60 seconds in compound-specific mode
  • Extended range up to 10,000 ppm (in VOC mode) with improved linearity
  • Built-in humidity sensor
  • Automatic temperature-controlled sampling time calculation
  • Highly specific readings, combining a 9.8eV UV lamp and RAE-Sep™ benzene tube
  • New sampling probe design provides instant tube-breakthrough visibility
  • Versatile VOC or Benzene-Specific modes
  • Real-time wireless with built-in Bluetooth and optional RAELink3 portable modem
  • Integrated RAE Systems Correction Factors list for more than 200 compounds

Easy to Use:

  • Large graphic display
  • Multi-language support
  • Easy access to lamp, sensor and battery in seconds without tools

Low Cost of Ownership:

  • Inexpensive analysis using low-cost RAE-Sep tubes

Applications:

  • Confined space entry pre-screening during refinery and plant maintenance
  • Hazardous material response
  • Marine spill response
  • Refinery down-stream monitoring
  • Plant overhaul

Monitor Only Includes:

  • UltraRAE 3000 Monitor, Model PGM-7360
  • Wireless communication module built-in
  • Datalogging with ProRAE Studio II Package for Windows® XP, Windows® Vista, or Windows® 7
  • Travel Charger
  • RAE UV lamp and RAE-Sep™ Tubes
  • Flex-I-Probe™ and short probe
  • External filter
  • Red rubber boot
  • Alkaline battery adapter
  • Lamp-cleaning kit
  • Tool kit
  • Lithium-ion (Li-Ion) battery with universal AC/DC charger and international plug kit
  • Operation CD-ROM
  • Operation & Maintenance manual
  • Soft leather carrying case
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 26 ounce av
    • 738 gram
  • Instrument Size
    • 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
  • Weight range
    • 738 g gram

Category

  • Sub-Category
    • Portable Handheld Compound-Specific VOC Monitor
    • Premium-Gas

Range

  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent
  • Extended Range
    • 0.01-10,000 ppm
  • Sensor Range
    • Benzene 0 -200 ppm
    • Butadiene 0-200 ppm
    • VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Alarm

  • Alarm Settings
    • Additional Diagnostic Alarm and Display Message for Low Battery and Pump Stall
    • Alarm Latching with Manual Override or Automatic Reset
    • High: 3 Beeps and Flashes per sec
    • Low: 2 Beeps and Flashes per sec
  • Alarm Type
    • Audible (95 dB)
    • Visual (LED)

Features

  • Alarm Included
    • Yes
  • Series Name
    • UltraRAE 3000+
  • Languages
    • Multi-Language Support

Battery & Charging

  • Batteries Required
    • Yes
  • Batteries Included
    • Yes
  • Battery Run Time
    • 16 Hours hours

Calibration

  • Calibration Procedures
    • Calibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates
    • Reflex PID Technology
    • Two-Point or Three-Point Calibration for Zero and Span
  • Calibration Points
    • 2
    • 3

Certifications

  • Standards
    • Europe: ATEX II 2G EEx ia IIC T4
    • IECEx CSA 10.0005 Ex ia IIC/IIB GbT4
    • US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Standard 6 Months at 1 min Intervals
    • Standard 6 months at one-minute intervals

Display

  • Display Viewing Area
    • 28 x 43 mm
  • Display Included
    • Yes

Features & Benefits

  • Features & Benefits
    • Built-In Humidity Sensor with Automatic Temperature Controlled Sampling Time Calculation
    • Cost Effective Solution and Low-Cost RAE-SepTM Tubes
    • Easy Access to Lamp, Sensor and Battery in Seconds without Tools
    • Highly Connectivity Capability through Multiple Wireless Module Options
    • Highly Specific Readings, Combining a 9.8eV UV Lamp and RAE-Sep™ Benzene Tube
    • Multi-Language Support
    • Reflex PID Technology
    • See-Through Sampling Probe Design for Instant Tube Breakthrough Visibility
    • Versatile VOC or Benzene-Specific Modes

Filter

  • Filter Included
    • No

Options

  • User Options
    • Alarms latching with manual override or automatic reset

Sampling

  • Sampling Pump Included
    • Yes
  • Sampling Pump Range
    • 100 ft meter
    • 100ft (30m) meter
  • Sampling Pump Rate
    • 400

Sensor

  • Number of Sensors Included
    • 3
  • Sensor Mechanism
    • Photoionization
  • Sensor Type
    • Photoionization

Warranty

  • Warranty
    • 1 Year for Pump, Battery, Sensor and Instrument
    • 3 Years for 10.6 eV Lamp
    • 6 Months for 9.8 eV Lamp

Wireless

  • Wireless Technology
    • MESH, BLE
  • Wireless Enabled
    • Yes

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Additional Specifications

  • Combustible
    • Yes
  • Gas Type
    • VOC, Benzene, Butadiene
  • Decibels
    • 95 decibel

Dimensions & Weight

  • Size
    • 10 in L x 3.0 in W x 2.5 in H

Technical Specifications

  • Communication and Data Download
    • Download Data and Upload Instrument Set-Up From PC Through Charging Cradle or Using BLE Module and Dedicated App
    • Wireless Data Transmission Through Built-In RF Modem
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Wireless Network
    • Mesh RAE Systems Dedicated Wireless Network
  • Display Graphic
    • 4 Lines, 28 x 43 mm
  • Wireless Range
    • EchoView Host: LOS > 660 ft (200 m)
    • ProRAE Guardian and RAELink3 Mesh: LOS > 330 ft (100m)
    • ProRAE Guardian and RAEMesh Reader: LOS > 660 ft (200m)
    • Up to 15 ft (5m) for BLE
  • Gases Detected
    • VOCS, Benzene, Butadiene
  • Direct Readout
    • Battery and Shutdown Voltage
    • Date and Time
    • High and Low Values
    • STEL and TWA
    • Temperature
    • VOCs as ppm by Volume (mg/m³)
  • Model Number
    • PGM-7360
  • Keypad Type
    • 1 Operation and 2 Programming Keys, 1 Flashlight On/Off
  • Resolution
    • Benzene 0.010 ppm
    • Butadiene 0.010 ppm
    • VOCs 0.010 ppm, 0.1 ppm, 1 ppm
  • Attachment
    • Durable Bright Red Rubber Boot
  • Pump Draw
    • Sample from 100 ft (30m) Horizontally or Vertically
  • Sampling
    • Internal
  • EMC/RFI
    • EMC Directive: 2004/108/EC
    • EMI and ESD Test: 100 MHz to 1 GHz 30V/m, No Alarm, Contact: ±4kV, Air: ±8kV, No Alarm

Material Specifications

  • Housing Material
    • Rubber

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Confined Space Entry Pre-Screening During Refinery and Plant Maintenance
    • Hazardous Material Response
    • Marine Spill Response
    • Plant Overhaul
    • Refinery Down-Stream Monitoring

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 26 ounce av
    • 738 gram
  • Instrument Size
    • 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
  • Weight range
    • 738 g gram

Category

  • Sub-Category
    • Portable Handheld Compound-Specific VOC Monitor
    • Premium-Gas

Range

  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent
  • Extended Range
    • 0.01-10,000 ppm
  • Sensor Range
    • Benzene 0 -200 ppm
    • Butadiene 0-200 ppm
    • VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Alarm

  • Alarm Settings
    • Additional Diagnostic Alarm and Display Message for Low Battery and Pump Stall
    • Alarm Latching with Manual Override or Automatic Reset
    • High: 3 Beeps and Flashes per sec
    • Low: 2 Beeps and Flashes per sec
  • Alarm Type
    • Audible (95 dB)
    • Visual (LED)

Features

  • Alarm Included
    • Yes
  • Series Name
    • UltraRAE 3000+
  • Languages
    • Multi-Language Support

Battery & Charging

  • Batteries Required
    • Yes
  • Batteries Included
    • Yes
  • Battery Run Time
    • 16 Hours hours

Calibration

  • Calibration Procedures
    • Calibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates
    • Reflex PID Technology
    • Two-Point or Three-Point Calibration for Zero and Span
  • Calibration Points
    • 2
    • 3

Certifications

  • Standards
    • Europe: ATEX II 2G EEx ia IIC T4
    • IECEx CSA 10.0005 Ex ia IIC/IIB GbT4
    • US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Standard 6 Months at 1 min Intervals
    • Standard 6 months at one-minute intervals

Display

  • Display Viewing Area
    • 28 x 43 mm
  • Display Included
    • Yes

Features & Benefits

  • Features & Benefits
    • Built-In Humidity Sensor with Automatic Temperature Controlled Sampling Time Calculation
    • Cost Effective Solution and Low-Cost RAE-SepTM Tubes
    • Easy Access to Lamp, Sensor and Battery in Seconds without Tools
    • Highly Connectivity Capability through Multiple Wireless Module Options
    • Highly Specific Readings, Combining a 9.8eV UV Lamp and RAE-Sep™ Benzene Tube
    • Multi-Language Support
    • Reflex PID Technology
    • See-Through Sampling Probe Design for Instant Tube Breakthrough Visibility
    • Versatile VOC or Benzene-Specific Modes

Filter

  • Filter Included
    • No

Options

  • User Options
    • Alarms latching with manual override or automatic reset

Sampling

  • Sampling Pump Included
    • Yes
  • Sampling Pump Range
    • 100 ft meter
    • 100ft (30m) meter
  • Sampling Pump Rate
    • 400

Sensor

  • Number of Sensors Included
    • 3
  • Sensor Mechanism
    • Photoionization
  • Sensor Type
    • Photoionization

Warranty

  • Warranty
    • 1 Year for Pump, Battery, Sensor and Instrument
    • 3 Years for 10.6 eV Lamp
    • 6 Months for 9.8 eV Lamp

Wireless

  • Wireless Technology
    • MESH, BLE
  • Wireless Enabled
    • Yes

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Additional Specifications

  • Combustible
    • Yes
  • Gas Type
    • VOC, Benzene, Butadiene
  • Decibels
    • 95 decibel

Dimensions & Weight

  • Size
    • 10 in L x 3.0 in W x 2.5 in H

Technical Specifications

  • Communication and Data Download
    • Download Data and Upload Instrument Set-Up From PC Through Charging Cradle or Using BLE Module and Dedicated App
    • Wireless Data Transmission Through Built-In RF Modem
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Wireless Network
    • Mesh RAE Systems Dedicated Wireless Network
  • Display Graphic
    • 4 Lines, 28 x 43 mm
  • Wireless Range
    • EchoView Host: LOS > 660 ft (200 m)
    • ProRAE Guardian and RAELink3 Mesh: LOS > 330 ft (100m)
    • ProRAE Guardian and RAEMesh Reader: LOS > 660 ft (200m)
    • Up to 15 ft (5m) for BLE
  • Gases Detected
    • VOCS, Benzene, Butadiene
  • Direct Readout
    • Battery and Shutdown Voltage
    • Date and Time
    • High and Low Values
    • STEL and TWA
    • Temperature
    • VOCs as ppm by Volume (mg/m³)
  • Model Number
    • PGM-7360
  • Keypad Type
    • 1 Operation and 2 Programming Keys, 1 Flashlight On/Off
  • Resolution
    • Benzene 0.010 ppm
    • Butadiene 0.010 ppm
    • VOCs 0.010 ppm, 0.1 ppm, 1 ppm
  • Attachment
    • Durable Bright Red Rubber Boot
  • Pump Draw
    • Sample from 100 ft (30m) Horizontally or Vertically
  • Sampling
    • Internal
  • EMC/RFI
    • EMC Directive: 2004/108/EC
    • EMI and ESD Test: 100 MHz to 1 GHz 30V/m, No Alarm, Contact: ±4kV, Air: ±8kV, No Alarm

Material Specifications

  • Housing Material
    • Rubber

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Confined Space Entry Pre-Screening During Refinery and Plant Maintenance
    • Hazardous Material Response
    • Marine Spill Response
    • Plant Overhaul
    • Refinery Down-Stream Monitoring
  • Brand : Honeywell RAE Systems|RAE
  • Weight : 26 ounce av|738 gram
  • Sub-Category : Portable Handheld Compound-Specific VOC Monitor|Premium-Gas
  • Instrument Size : 10” L x 3.0” W x 2.5” H (25.5 x 7.6 x 6.4 cm)
  • Weight range : 738 g gram
  • Humidity Range : 0 to 95% RH (Non-Condensing) percent|0%-95% percent
  • Extended Range : 0.01-10,000 ppm
  • Sensor Range : Benzene 0 -200 ppm|Butadiene 0-200 ppm|VOCs 0 to 99.99 ppm, 100 to 999.9 ppm, 1000 to 9999 ppm
  • Minimum Temperature : -20|-20 degree Celsius|-4 degree Fahrenheit
  • Maximum Temperature : 122 degree Fahrenheit|50|50 degree Celsius
  • Alarm Settings : Additional Diagnostic Alarm and Display Message for Low Battery and Pump Stall|Alarm Latching with Manual Override or Automatic Reset|High: 3 Beeps and Flashes per sec|Low: 2 Beeps and Flashes per sec
  • Alarm Included : Yes
  • Alarm Type : Audible (95 dB)|Visual (LED)
  • Batteries Required : Yes
  • Batteries Included : Yes
  • Battery Run Time : 16 Hours hours
  • Calibration Procedures : Calibration Memory for 8 Calibration Gases, Alarm Limits, Span Values and Calibration Dates|Reflex PID Technology|Two-Point or Three-Point Calibration for Zero and Span
  • Calibration Points : 2|3
  • Standards : Europe: ATEX II 2G EEx ia IIC T4|IECEx CSA 10.0005 Ex ia IIC/IIB GbT4|US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Div 1 Group A, B, C, D
  • Datalogging Interval : 1 min
  • Datalogging Capable : Yes
  • Datalogging : Standard 6 Months at 1 min Intervals|Standard 6 months at one-minute intervals
  • Display Viewing Area : 28 x 43 mm
  • Display Included : Yes
  • Features & Benefits : Built-In Humidity Sensor with Automatic Temperature Controlled Sampling Time Calculation|Cost Effective Solution and Low-Cost RAE-SepTM Tubes|Easy Access to Lamp, Sensor and Battery in Seconds without Tools|Highly Connectivity Capability through Multiple Wireless Module Options|Highly Specific Readings, Combining a 9.8eV UV Lamp and RAE-Sep™ Benzene Tube|Multi-Language Support|Reflex PID Technology|See-Through Sampling Probe Design for Instant Tube Breakthrough Visibility|Versatile VOC or Benzene-Specific Modes
  • Filter Included : No
  • User Options : Alarms latching with manual override or automatic reset
  • Sampling Pump Included : Yes
  • Sampling Pump Range : 100 ft meter|100ft (30m) meter
  • Sampling Pump Rate : 400
  • Number of Sensors Included : 3
  • Sensor Mechanism : Photoionization
  • Sensor Type : Photoionization
  • Warranty : 1 Year for Pump, Battery, Sensor and Instrument|3 Years for 10.6 eV Lamp|6 Months for 9.8 eV Lamp
  • Wireless Technology : MESH, BLE
  • Wireless Enabled : Yes
  • Ingress Protection : IP65|IP65
  • Combustible : Yes
  • Gas Type : VOC, Benzene, Butadiene
  • Decibels : 95 decibel
  • Size : 10 in L x 3.0 in W x 2.5 in H
  • Communication and Data Download : Download Data and Upload Instrument Set-Up From PC Through Charging Cradle or Using BLE Module and Dedicated App|Wireless Data Transmission Through Built-In RF Modem
  • Wireless Approvals : CE RandTTE|FCC Part 15
  • Wireless Network : Mesh RAE Systems Dedicated Wireless Network
  • Housing Material : Rubber
  • Display Graphic : 4 Lines, 28 x 43 mm
  • Wireless Range : EchoView Host: LOS > 660 ft (200 m)|ProRAE Guardian and RAELink3 Mesh: LOS > 330 ft (100m)|ProRAE Guardian and RAEMesh Reader: LOS > 660 ft (200m)|Up to 15 ft (5m) for BLE
  • Gases Detected : VOCS, Benzene, Butadiene
  • Direct Readout : Battery and Shutdown Voltage|Date and Time|High and Low Values|STEL and TWA|Temperature|VOCs as ppm by Volume (mg/m³)
  • Power Source : Battery
  • Model Number : PGM-7360
  • Series Name : UltraRAE 3000+
  • Keypad Type : 1 Operation and 2 Programming Keys, 1 Flashlight On/Off
  • Application : Confined Space Entry Pre-Screening During Refinery and Plant Maintenance|Hazardous Material Response|Marine Spill Response|Plant Overhaul|Refinery Down-Stream Monitoring
  • Resolution : Benzene 0.010 ppm|Butadiene 0.010 ppm|VOCs 0.010 ppm, 0.1 ppm, 1 ppm
  • Attachment : Durable Bright Red Rubber Boot
  • Pump Draw : Sample from 100 ft (30m) Horizontally or Vertically
  • Languages : Multi-Language Support
  • Sampling : Internal
  • EMC/RFI : EMC Directive: 2004/108/EC|EMI and ESD Test: 100 MHz to 1 GHz 30V/m, No Alarm, Contact: ±4kV, Air: ±8kV, No Alarm
Data Sheet
Name
Description
File Size
Date
Size
UltraRAE 3000+ Data Sheet - DE
application/pdf 472.5 KB
10/5/2023
472.5 KB
UltraRAE 3000+ Data Sheet - DE
application/pdf 472.5 KB
10/5/2023
472.5 KB
UltraRAE 3000+ Data Sheet - FR
application/pdf 467.94 KB
7/15/2021
467.94 KB
UltraRAE 3000+ Data Sheet - RU
application/pdf 581.71 KB
7/15/2021
581.71 KB
UltraRAE 3000+ Data Sheet - NL
application/pdf 468.16 KB
7/15/2021
468.16 KB
UltraRAE 3000+ Data Sheet - IT
application/pdf 467.99 KB
7/15/2021
467.99 KB
UltraRAE 3000+ Data Sheet - ES
application/pdf 469.7 KB
7/15/2021
469.7 KB
UltraRAE 3000+ Data Sheet - DE
application/pdf 472.01 KB
7/15/2021
472.01 KB
UltraRAE 3000+ Data Sheet - PT
application/pdf 469.58 KB
7/15/2021
469.58 KB
UltraRAE 3000+ Data Sheet - EN
application/pdf 2.08 MB
7/15/2021
2.08 MB
Manuals and Guides
Name
Description
File Size
Date
Size
3000+ Series PID Quick Start Guide - ES
application/pdf 735.47 KB
7/15/2021
735.47 KB
3000+ Series PID Quick Start Guide - EN
application/pdf 737.56 KB
4/23/2024
737.56 KB
Handheld PID Monitors User Manual - EN
application/pdf 6.83 MB
12/12/2023
6.83 MB
Software
Name
Description
File Size
Date
Size
UltraRAE3000+ PGM-7360 V2.22A.35
application/zip 963.72 KB
7/15/2021
963.72 KB
Technical Note
Name
Description
File Size
Date
Size
Lithium-Ion Batteries Technical Note 166
application/pdf 926.7 KB
7/15/2021
926.7 KB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
application/pdf 790.79 KB
7/15/2021
790.79 KB
Technical Note 141 Monitor Remote Control Functions
application/pdf 984.3 KB
8/3/2022
984.3 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
3GPID+ Technical Note
application/pdf 436.09 KB
7/15/2021
436.09 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 127 Benzene-Specific Measurements In Petroleum Hydrocarbons Using The RAE Systems UltraRAE 3000
application/pdf 798.21 KB
7/15/2021
798.21 KB
Technical Note 170 USB To Serial Port Adapter
application/pdf 1.26 MB
7/15/2021
1.26 MB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
2/8/2022
1.09 MB
Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
application/pdf 624.75 KB
7/15/2021
624.75 KB
Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
Certificate
Name
Description
File Size
Date
Size
EU & UK Declaration of Conformity UltraRAE 3000
application/pdf 200.94 KB
6/26/2023
200.94 KB
UltraRAE 3000 +,RAESep Tubes Warning Letter
application/pdf 20.63 KB
7/15/2021
20.63 KB
UltraRAE 3000 EU Declaration of Conformity
application/pdf 208.5 KB
1/11/2022
208.5 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Application Note 214: Environmental Applications For PIDs
application/pdf 836.36 KB
7/15/2021
836.36 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 729.36 KB
7/15/2021
729.36 KB
Name
Description
File Size
Date
Size
Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
application/pdf 964.88 KB
7/15/2021
964.88 KB
Lithium-Ion Batteries Technical Note 166
application/pdf 926.7 KB
7/15/2021
926.7 KB
Application Note 214: Environmental Applications For PIDs
application/pdf 836.36 KB
7/15/2021
836.36 KB
EU & UK Declaration of Conformity UltraRAE 3000
application/pdf 200.94 KB
6/26/2023
200.94 KB
Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
application/pdf 790.79 KB
7/15/2021
790.79 KB
UltraRAE 3000+ Data Sheet - DE
application/pdf 472.5 KB
10/5/2023
472.5 KB
UltraRAE 3000+ Data Sheet - DE
application/pdf 472.5 KB
10/5/2023
472.5 KB
UltraRAE 3000+ Data Sheet - FR
application/pdf 467.94 KB
7/15/2021
467.94 KB
Technical Note 141 Monitor Remote Control Functions
application/pdf 984.3 KB
8/3/2022
984.3 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
3GPID+ Technical Note
application/pdf 436.09 KB
7/15/2021
436.09 KB
UltraRAE 3000+ Data Sheet - RU
application/pdf 581.71 KB
7/15/2021
581.71 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Technical Note 165 Combating Drift In Portable And Fixed PIDs
application/pdf 930.69 KB
7/15/2021
930.69 KB
3000+ Series PID Quick Start Guide - ES
application/pdf 735.47 KB
7/15/2021
735.47 KB
UltraRAE 3000+ Data Sheet - NL
application/pdf 468.16 KB
7/15/2021
468.16 KB
UltraRAE3000+ PGM-7360 V2.22A.35
application/zip 963.72 KB
7/15/2021
963.72 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 127 Benzene-Specific Measurements In Petroleum Hydrocarbons Using The RAE Systems UltraRAE 3000
application/pdf 798.21 KB
7/15/2021
798.21 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Technical Note 170 USB To Serial Port Adapter
application/pdf 1.26 MB
7/15/2021
1.26 MB
UltraRAE 3000+ Data Sheet - IT
application/pdf 467.99 KB
7/15/2021
467.99 KB
3000+ Series PID Quick Start Guide - EN
application/pdf 737.56 KB
4/23/2024
737.56 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
UltraRAE 3000+ Data Sheet - ES
application/pdf 469.7 KB
7/15/2021
469.7 KB
Monitoring Benzene and Choosing an Appropriate Monitor for Personal Protection and Compliance with Exposure Limits
application/pdf 729.36 KB
7/15/2021
729.36 KB
UltraRAE 3000+ Data Sheet - DE
application/pdf 472.01 KB
7/15/2021
472.01 KB
UltraRAE 3000+ Data Sheet - PT
application/pdf 469.58 KB
7/15/2021
469.58 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
UltraRAE 3000 +,RAESep Tubes Warning Letter
application/pdf 20.63 KB
7/15/2021
20.63 KB
Handheld PID Monitors User Manual - EN
application/pdf 6.83 MB
12/12/2023
6.83 MB
UltraRAE 3000 EU Declaration of Conformity
application/pdf 208.5 KB
1/11/2022
208.5 KB
Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
application/pdf 1.09 MB
2/8/2022
1.09 MB
Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
application/pdf 624.75 KB
7/15/2021
624.75 KB
Technical Note 158 Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
application/pdf 950.72 KB
7/15/2021
950.72 KB
UltraRAE 3000+ Data Sheet - EN
application/pdf 2.08 MB
7/15/2021
2.08 MB
Name
Date
Size
Showing 1 to 1 of 1 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
059-D316-200
ULTRARAE 3KPID9.8RE LI-IONNO-WLSSATX
https://s7d1.scene7.com/is/image/Honeywell65/UltraRAE3000
059-D316-200
ULTRARAE 3KPID9.8RE LI-IONNO-WLSSATX
https://s7d1.scene7.com/is/image/Honeywell65/UltraRAE3000
Feedback