/content/sps/gb/en/search-results.html

    Photoionization Detectors (PID)

    MiniRAE 3000 +

    The most advanced wireless handheld VOC monitor with parts per million measurement

    Overview
    Whether for industrial hygiene, leak detection, or HazMat response, the MiniRAE 3000 + delivers one of the most advanced VOC monitoring capabilities on the market. With a photoionization detector (PID) that has an extended detection range from 0-15,000 ppm, a rapid three-second response time, built-in correction factors for more than 200 compounds, patented auto-cleaning sensor technology and Reflex PID Technology™, the MiniRAE 3000 + can measure one of the highest levels of ionizable chemicals available on the market.The powerful sample pump draws through up to 100 feet of tubing horizontally or vertically. A built-in flashlight to help navigate in darker environments and an IP 65/67 dust-tight and water-proof housing all add up to a device that performs reliably even in harsh conditions.MiniRAE 3000 + is solution oriented through multiple connected options. A dedicated mobile APP has been developed for Remediation engineers and Industrial Hygienists. Instrument is also available with real time connectivity which can relay readings and alarm status up to 2 miles to a RAELink 3 wireless transmitter.Features and Benefits:
    • Most advanced handheld VOC monitor on the market
    • PID measures from 0-15,000 ppm
    • 3-second response
    • Humidity compensation
    • Patented PID lamp auto-cleaning technology
    • Patented Reflex PID Technology™
    • Optional Mesh Radio for ConneXT compatibility
    • Optional built-in Bluetooth transmitter that transmits real-time data up to 2 miles with RAELink3 wireless router
    • Optional BLE Module
    • Sample pump draws from up to 100 feet
    • Correction factors for more than 200 compounds
    • Built-in flashlight
    • IP 65/67 water-proof and dust-tight
    • Logs up to 6 months of data at 1-minute intervals
    • Multi-language capability – up to 10 languages
    • 9.8eV for benzene and TVOC and 10.6 and 11.7 UV lamps for TVOC
    Application:
    • Emergency Response
    • Environmental Cleanups/ Remediation
    • Hazmat Response
    • Leak Detection
    • Urban Search & Rescue
    • Venue Protection
    • Worker Exposure
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Brand

    • Brand
      • RAE

    Category

    • Sub-Category
      • Premium-Gas

    Dimension & Weight

    • Instrument Size
      • 10" L x 3.0" W x 2.5" H (25.5 x 7.6 x 6.4 cm)

    Range

    • Sensor Range
      • VOC (0-15000ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-16 hours

    Certifications

    • Standards & Certifications
      • US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Division 1

    Datalogging

    • Datalogging
      • Standard 6 months at one-minute intervals

    Features & Benefits

    • Features & Benefits
      • Third-generation patented PID technology

    Options

    • User Options
      • Alarms latching with manual override or automatic reset

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • 3 years for 10.6 eV lamp, 1 year for

    Wireless

    • Wireless Technology
      • MESH, BLE

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • VOC

    Others

    • Maximum Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius
    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 26 ounce av
      • 738 gram

    Brand

    • Brand
      • RAE

    Category

    • Sub-Category
      • Premium-Gas

    Dimension & Weight

    • Instrument Size
      • 10" L x 3.0" W x 2.5" H (25.5 x 7.6 x 6.4 cm)

    Range

    • Sensor Range
      • VOC (0-15000ppm)
    • Humidity Range
      • 0%-95% percent

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-16 hours

    Certifications

    • Standards & Certifications
      • US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Division 1

    Datalogging

    • Datalogging
      • Standard 6 months at one-minute intervals

    Features & Benefits

    • Features & Benefits
      • Third-generation patented PID technology

    Options

    • User Options
      • Alarms latching with manual override or automatic reset

    Sampling

    • Sampling Pump Range
      • 100ft (30m) meter

    Warranty

    • Warranty
      • 3 years for 10.6 eV lamp, 1 year for

    Wireless

    • Wireless Technology
      • MESH, BLE

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • VOC

    Others

    • Maximum Temperature
      • 122 degree Fahrenheit
      • 50 degree Celsius
    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Weight
      • 26 ounce av
      • 738 gram
    • Brand : RAE
    • Maximum Temperature : 122 degree Fahrenheit|50 degree Celsius
    • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
    • Weight : 26 ounce av|738 gram
    • Sub-Category : Premium-Gas
    • Instrument Size : 10" L x 3.0" W x 2.5" H (25.5 x 7.6 x 6.4 cm)
    • Sensor Range : VOC (0-15000ppm)
    • Humidity Range : 0%-95% percent
    • Alarm Type : Audible, Visual, Vibrating
    • Battery Run Time : 12-16 hours
    • Standards & Certifications : US and Canada: CSA, Classified as Intrinsically Safe for use in Class I, Division 1
    • Datalogging : Standard 6 months at one-minute intervals
    • Features & Benefits : Third-generation patented PID technology
    • User Options : Alarms latching with manual override or automatic reset
    • Sampling Pump Range : 100ft (30m) meter
    • Warranty : 3 years for 10.6 eV lamp, 1 year for
    • Wireless Technology : MESH, BLE
    • Ingress Protection : IP65
    • Gas Type : VOC
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    MiniRAE 3000 + Data Sheet - NL
    application/pdf 572.3 KB
    7/15/2021
    572.3 KB
    MiniRAE 3000 + Data Sheet - FR
    application/pdf 574.31 KB
    7/15/2021
    574.31 KB
    MiniRAE 3000 + Data Sheet - RU
    application/pdf 604.02 KB
    7/15/2021
    604.02 KB
    MiniRAE 3000+ Data Sheet - DE
    application/pdf 575.45 KB
    7/15/2021
    575.45 KB
    MiniRAE 3000 + Data Sheet - EN
    application/pdf 570.25 KB
    7/15/2021
    570.25 KB
    MiniRAE 3000 + Data Sheet - ES
    application/pdf 572.94 KB
    7/15/2021
    572.94 KB
    MiniRAE 3000 + Data Sheet - PT
    application/pdf 574.41 KB
    7/15/2021
    574.41 KB
    MiniRAE 3000 + Data Sheet - IT
    application/pdf 577.93 KB
    7/15/2021
    577.93 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    3000+ Series PID Quick Start Guide - EN
    application/pdf 737.56 KB
    4/23/2024
    737.56 KB
    Handheld PID Monitors User Manual - EN
    application/pdf 6.83 MB
    12/12/2023
    6.83 MB
    3000+ Series PID Quick Start Guide - ES
    application/pdf 735.47 KB
    7/15/2021
    735.47 KB
    Software
    Name
    Description
    File Size
    Date
    Size
    MiniRAE3000+ PGM-7320 V2.22A.35
    application/zip 963.57 KB
    7/15/2021
    963.57 KB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    3GPID+ Technical Note
    application/pdf 436.09 KB
    7/15/2021
    436.09 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    7/15/2021
    790.79 KB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    application/pdf 813.81 KB
    2/8/2022
    813.81 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
    application/pdf 624.75 KB
    7/15/2021
    624.75 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/15/2021
    926.7 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    9/14/2022
    820.7 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Certificate
    Name
    Description
    File Size
    Date
    Size
    EU Declaration of Conformity - MiniRAE 3000+ and MiniRAE Lite+
    application/pdf 240.01 KB
    2/27/2023
    240.01 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    7/15/2021
    836.36 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Name
    Description
    File Size
    Date
    Size
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    3000+ Series PID Quick Start Guide - EN
    application/pdf 737.56 KB
    4/23/2024
    737.56 KB
    Handheld PID Monitors User Manual - EN
    application/pdf 6.83 MB
    12/12/2023
    6.83 MB
    EU Declaration of Conformity - MiniRAE 3000+ and MiniRAE Lite+
    application/pdf 240.01 KB
    2/27/2023
    240.01 KB
    3GPID+ Technical Note
    application/pdf 436.09 KB
    7/15/2021
    436.09 KB
    MiniRAE 3000 + Data Sheet - NL
    application/pdf 572.3 KB
    7/15/2021
    572.3 KB
    MiniRAE3000+ PGM-7320 V2.22A.35
    application/zip 963.57 KB
    7/15/2021
    963.57 KB
    MiniRAE 3000 + Data Sheet - FR
    application/pdf 574.31 KB
    7/15/2021
    574.31 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    7/15/2021
    790.79 KB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    application/pdf 813.81 KB
    2/8/2022
    813.81 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/15/2021
    911.54 KB
    Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
    application/pdf 624.75 KB
    7/15/2021
    624.75 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    MiniRAE 3000 + Data Sheet - RU
    application/pdf 604.02 KB
    7/15/2021
    604.02 KB
    MiniRAE 3000+ Data Sheet - DE
    application/pdf 575.45 KB
    7/15/2021
    575.45 KB
    MiniRAE 3000 + Data Sheet - EN
    application/pdf 570.25 KB
    7/15/2021
    570.25 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    7/15/2021
    836.36 KB
    3000+ Series PID Quick Start Guide - ES
    application/pdf 735.47 KB
    7/15/2021
    735.47 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/15/2021
    926.7 KB
    MiniRAE 3000 + Data Sheet - ES
    application/pdf 572.94 KB
    7/15/2021
    572.94 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    9/14/2022
    820.7 KB
    MiniRAE 3000 + Data Sheet - PT
    application/pdf 574.41 KB
    7/15/2021
    574.41 KB
    MiniRAE 3000 + Data Sheet - IT
    application/pdf 577.93 KB
    7/15/2021
    577.93 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Name
    Description
    File Size
    Date
    Size
    MiniRAE 3000 + Data Sheet - NL
    572.3 KB
    7/15/2021
    MiniRAE 3000 + Data Sheet - FR
    574.31 KB
    7/15/2021
    MiniRAE 3000 + Data Sheet - RU
    604.02 KB
    7/15/2021
    MiniRAE 3000+ Data Sheet - DE
    575.45 KB
    7/15/2021
    MiniRAE 3000 + Data Sheet - EN
    570.25 KB
    7/15/2021
    MiniRAE 3000 + Data Sheet - ES
    572.94 KB
    7/15/2021
    MiniRAE 3000 + Data Sheet - PT
    574.41 KB
    7/15/2021
    MiniRAE 3000 + Data Sheet - IT
    577.93 KB
    7/15/2021
    3000+ Series PID Quick Start Guide - EN
    737.56 KB
    4/23/2024
    Handheld PID Monitors User Manual - EN
    6.83 MB
    12/12/2023
    3000+ Series PID Quick Start Guide - ES
    735.47 KB
    7/15/2021
    MiniRAE3000+ PGM-7320 V2.22A.35
    963.57 KB
    7/15/2021
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    814.89 KB
    7/15/2021
    3GPID+ Technical Note
    436.09 KB
    7/15/2021
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    790.79 KB
    7/15/2021
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    1.09 MB
    2/8/2022
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    813.81 KB
    2/8/2022
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    911.54 KB
    7/15/2021
    Technical Note 120 Measuring PID Correction Factors For Volatile Compounds With RAE Systems Instruments
    624.75 KB
    7/15/2021
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    930.69 KB
    7/15/2021
    Technical Note 170 USB To Serial Port Adapter
    1.26 MB
    7/15/2021
    Technical Note 148 Defining The Interval Between Calibration Checks
    839.32 KB
    12/14/2022
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    950.72 KB
    7/15/2021
    Lithium-Ion Batteries Technical Note 166
    926.7 KB
    7/15/2021
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    9/14/2022
    Technical Note 130 Setting Alarm Limits For Mixtures
    788.83 KB
    7/15/2021
    EU Declaration of Conformity - MiniRAE 3000+ and MiniRAE Lite+
    240.01 KB
    2/27/2023
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    1.07 MB
    7/15/2021
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    964.88 KB
    7/15/2021
    Application Note 203: PIDs As HazMat Response Tools
    1.26 MB
    7/15/2021
    Application Note 214: Environmental Applications For PIDs
    836.36 KB
    7/15/2021
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    7/15/2021
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    655.59 KB
    7/15/2021
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list