Overview
his-rae-multirae-lite-pump-front-hires
This multi-gas monitor provides versatile, customizable detection and monitoring of up to six gases, available in both pumped and diffused air models. With more than 25 sensors to choose from — the broadest selection in its class — it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a range of industries and applications. The wireless connection sends threat and alarm data in real time to a central command, providing superior awareness for fast incident response. And its replaceable sensors, alarm, and battery, large screen, and automated bump testing and calibration make it easy to use and maintain.Features and Benefits:
  • Multi-gas monitor for 1-6 gases
  • Pumped and diffusion models available
  • Man down alarm
  • More than 25 different chemical sensors
  • Fully automatic bump testing and calibration
  • Real-time access to readings at central command
  • Swap out sensors as needed
  • Simple maintenance with replaceable sensors, pump, and battery
  • 5-way local and remote wireless alarm
  • Multi-language capability – up to 18 languages
  • Device Management with Honeywell Sotera™ Express
  • Readily enables to communicate with Motorola MOTOTRBO
Application:
  • Clandestine Labs
  • Confined Space Entry
  • Emergency Response
  • Environmental Cleanups/ Remediation
  • Exploration
  • Fire Overhaul
  • Fracking
  • Hazmat Response
  • Plant Shutdown & Turn-Around
  • Urban Search & Rescue
Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Specifications

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 31 ounce av
    • 880 gram
  • Weight range
    • 880 g gram
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Category

  • Sub-Category
    • Multi-Gas

Range

  • Sensor Range
    • Carbon Dioxide (CO2) NDIR 0 to 50,000 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Features

  • Alarm Included
    • Yes
  • Series Name
    • MultiRAE Lite Pumped
  • Languages
    • Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish

Alarm

  • Alarm Type
    • Audible (95 dB @30 cm)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)

Battery & Charging

  • Charging Time
    • 6 hours
    • 9 hours
  • Battery Run Time
    • 12-18 hours
    • Alkaline Adapter with 4 X AA Batteries 6 Hours hours
    • Extended Duration Li-Ion (18 Hours) hours
    • Rechargeable Li-Ion (12 Hours) hours
  • Batteries Required
    • Yes
  • Batteries Included
    • Yes

Calibration

  • Calibration Procedures
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual

Certifications

  • Standards
    • ATEX: 0575 II 1G Ex ia IIC T4 Ga
    • ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed
    • ATEX: I M1 Ex ia I Ma
    • CSA: Class I, Div 1, Group A, B, C, D, T4
    • CSA: Class II, Div 1, Group E, F, G T85°C
    • IECEx/ANZEx: Ex ia I Ma
    • IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: Ex ia IIC T4 Ga
    • IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: I M1 Ex ia I Ma
  • Certifications - Performance
    • ISA-12.13.01
    • LEL CSA C22.2 No. 152

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Display

  • Display Type
    • Monochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature
  • Display Readout
    • Man Down Alarm On/Off; Visual Compliance Indicator; Battery Status; Datalogging On/Off; Wireless On/Off and Reception Quality
    • Real-Time Reading of Gas Concentrations; PID Measurement Gas and Correction Factor
    • STEL, TWA, Peak and Minimum Values
  • Display Matrix
    • 128 x 160
  • Display Included
    • Yes

Features & Benefits

  • Features & Benefits
    • Device Management with Honeywell SafetySuite
    • Easy Maintenance with Replaceable Sensors, Pump, and Plug-and-Play Battery
    • Highly Versatile and Customizable
    • Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field
    • Large Graphical Display with Easy-to-Use, Icon-Driven User Interface
    • Over 25 Interchangeable Sensor Options, Including PID4 for VOCs, NDIR5 and Catalytic for Combustibles, and NDIR for CO2
    • Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions Including Man Down Alarm
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Sampling

  • Sampling Pump Range
    • 100ft (30m) meter
  • Sampling Pump Included
    • Yes

Sensor

  • Sensor Type
    • PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR
  • Number of Sensors Included
    • 25

Warranty

  • Warranty
    • 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components and Catalytic LEL Sensors
    • 3 Years on CO and H2S Sensors
    • 4 Years on Liq O2 Sensors

Wireless

  • Wireless Technology
    • BLE
  • Wireless Enabled
    • Yes

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Additional Specifications

  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • External Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Decibels
    • 95 decibel
  • Combustible
    • Yes

Technical Specifications

  • Wireless Range
    • MultiRAE Lite to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)
    • MultiRAE Lite to RAELink3 [Z1] Mesh Modem 330 ft (100m)
    • MultiRAE Lite to Wi-Fi Access Point - 330 ft (100m)
  • Wireless Network
    • EchoView Host-Based Closed-Loop System
    • ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Tests
    • Fully Automatic Bump Testing and Calibration with AutoRAE 2
  • Sampling
    • Built-In Pump
  • Radio Module
    • Supports RM900A
  • Model Number
    • PGM-6208
  • Keypad Type
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Gases Detected
    • CO2, H2S, CO, SO2, O2
  • EMC/RFI
    • EMC Directive: 2004/108/EC
  • Communication and Data Download
    • Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System
    • Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)

Dimensions & Weight

  • Size
    • H: 7.6 in W: 3.8 in D: 2.6 in

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Chemical
    • Fire Overhaul
    • Food and Beverage
    • Oil and Gas (Downstream)
    • Pharmaceutical
    • Telecommunications
    • Waste Water Treatment

Brand

  • Brand
    • Honeywell RAE Systems
    • RAE

Dimension & Weight

  • Weight
    • 31 ounce av
    • 880 gram
  • Weight range
    • 880 g gram
  • Instrument Size
    • 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]

Category

  • Sub-Category
    • Multi-Gas

Range

  • Sensor Range
    • Carbon Dioxide (CO2) NDIR 0 to 50,000 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol
    • NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Humidity Range
    • 0 to 95% RH (Non-Condensing) percent
    • 0%-95% percent

Temperature

  • Minimum Temperature
    • -20
    • -20 degree Celsius
    • -4 degree Fahrenheit
  • Maximum Temperature
    • 122 degree Fahrenheit
    • 50
    • 50 degree Celsius

Features

  • Alarm Included
    • Yes
  • Series Name
    • MultiRAE Lite Pumped
  • Languages
    • Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish

Alarm

  • Alarm Type
    • Audible (95 dB @30 cm)
    • Vibrating
    • Visual (Flashing Bright Red LEDs)

Battery & Charging

  • Charging Time
    • 6 hours
    • 9 hours
  • Battery Run Time
    • 12-18 hours
    • Alkaline Adapter with 4 X AA Batteries 6 Hours hours
    • Extended Duration Li-Ion (18 Hours) hours
    • Rechargeable Li-Ion (12 Hours) hours
  • Batteries Required
    • Yes
  • Batteries Included
    • Yes

Calibration

  • Calibration Procedures
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual

Certifications

  • Standards
    • ATEX: 0575 II 1G Ex ia IIC T4 Ga
    • ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed
    • ATEX: I M1 Ex ia I Ma
    • CSA: Class I, Div 1, Group A, B, C, D, T4
    • CSA: Class II, Div 1, Group E, F, G T85°C
    • IECEx/ANZEx: Ex ia I Ma
    • IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: Ex ia IIC T4 Ga
    • IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed
    • IECEx: I M1 Ex ia I Ma
  • Certifications - Performance
    • ISA-12.13.01
    • LEL CSA C22.2 No. 152

Datalogging

  • Datalogging Interval
    • 1 min
  • Datalogging Capable
    • Yes
  • Datalogging
    • Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Display

  • Display Type
    • Monochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature
  • Display Readout
    • Man Down Alarm On/Off; Visual Compliance Indicator; Battery Status; Datalogging On/Off; Wireless On/Off and Reception Quality
    • Real-Time Reading of Gas Concentrations; PID Measurement Gas and Correction Factor
    • STEL, TWA, Peak and Minimum Values
  • Display Matrix
    • 128 x 160
  • Display Included
    • Yes

Features & Benefits

  • Features & Benefits
    • Device Management with Honeywell SafetySuite
    • Easy Maintenance with Replaceable Sensors, Pump, and Plug-and-Play Battery
    • Highly Versatile and Customizable
    • Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field
    • Large Graphical Display with Easy-to-Use, Icon-Driven User Interface
    • Over 25 Interchangeable Sensor Options, Including PID4 for VOCs, NDIR5 and Catalytic for Combustibles, and NDIR for CO2
    • Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions Including Man Down Alarm
    • Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location

Options

  • User Options
    • 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected
    • User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)

Sampling

  • Sampling Pump Range
    • 100ft (30m) meter
  • Sampling Pump Included
    • Yes

Sensor

  • Sensor Type
    • PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR
  • Number of Sensors Included
    • 25

Warranty

  • Warranty
    • 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts
    • 2 Years on Non-Consumable Components and Catalytic LEL Sensors
    • 3 Years on CO and H2S Sensors
    • 4 Years on Liq O2 Sensors

Wireless

  • Wireless Technology
    • BLE
  • Wireless Enabled
    • Yes

Standards & Certifications

  • Ingress Protection
    • IP65
    • IP65

Additional Specifications

  • Gas Type
    • NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • External Calibration
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Decibels
    • 95 decibel
  • Combustible
    • Yes

Technical Specifications

  • Wireless Range
    • MultiRAE Lite to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)
    • MultiRAE Lite to RAELink3 [Z1] Mesh Modem 330 ft (100m)
    • MultiRAE Lite to Wi-Fi Access Point - 330 ft (100m)
  • Wireless Network
    • EchoView Host-Based Closed-Loop System
    • ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Approvals
    • CE RandTTE
    • FCC Part 15
  • Tests
    • Fully Automatic Bump Testing and Calibration with AutoRAE 2
  • Sampling
    • Built-In Pump
  • Radio Module
    • Supports RM900A
  • Model Number
    • PGM-6208
  • Keypad Type
    • Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Gases Detected
    • CO2, H2S, CO, SO2, O2
  • EMC/RFI
    • EMC Directive: 2004/108/EC
  • Communication and Data Download
    • Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System
    • Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)

Dimensions & Weight

  • Size
    • H: 7.6 in W: 3.8 in D: 2.6 in

Electrical Specifications

  • Power Source
    • Battery

Applications & Compatibility

  • Application
    • Chemical
    • Fire Overhaul
    • Food and Beverage
    • Oil and Gas (Downstream)
    • Pharmaceutical
    • Telecommunications
    • Waste Water Treatment
  • Brand : Honeywell RAE Systems|RAE
  • Weight : 31 ounce av|880 gram
  • Sub-Category : Multi-Gas
  • Weight range : 880 g gram
  • Instrument Size : 7.6 in x 3.8 in x 2.6 in D / [193 mm x 96.5 mm x 66 mm]
  • Sensor Range : Carbon Dioxide (CO2) NDIR 0 to 50,000 ppm, Hydrogen Sulfide (H2S) 0 to 100 ppm, Carbon Monoxide (CO) 0 to 500 ppm, Sulfur Dioxide (SO2) 0 to 20 ppm, Oxygen (O2) 0 to 30% Vol|NH3 (0-100ppm), CO (0-2000ppm), H2S (0-200ppm), CL2 (0-50ppm), CLO2 (0-1ppm), ETO (0-100ppm), HCHO (0-10ppm), HCN (0-50ppm), CH3-SH (0-10ppm), NO (0-250ppm), NO2 (0-20ppm), O2 (0-30%vol), PH3 (0-20ppm), SO2 (0-20ppm), VOC (0-5000ppm), LEL (0-100%LEL), CO2 (0-50000ppm)
  • Humidity Range : 0 to 95% RH (Non-Condensing) percent|0%-95% percent
  • Minimum Temperature : -20|-20 degree Celsius|-4 degree Fahrenheit
  • Maximum Temperature : 122 degree Fahrenheit|50|50 degree Celsius
  • Alarm Included : Yes
  • Alarm Type : Audible (95 dB @30 cm)|Vibrating|Visual (Flashing Bright Red LEDs)
  • Charging Time : 6 hours|9 hours
  • Battery Run Time : 12-18 hours|Alkaline Adapter with 4 X AA Batteries 6 Hours hours|Extended Duration Li-Ion (18 Hours) hours|Rechargeable Li-Ion (12 Hours) hours
  • Batteries Required : Yes
  • Batteries Included : Yes
  • Calibration Procedures : Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Calibration : Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Standards : ATEX: 0575 II 1G Ex ia IIC T4 Ga|ATEX: 2G Ex ia d IIC T4 Gb with IR Sensor Installed|ATEX: I M1 Ex ia I Ma|CSA: Class I, Div 1, Group A, B, C, D, T4|CSA: Class II, Div 1, Group E, F, G T85°C|IECEx/ANZEx: Ex ia I Ma|IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor Installed|IECEx: Ex ia IIC T4 Ga|IECEx: Ex ia d IIC T4 Gb with IR Sensor Installed|IECEx: I M1 Ex ia I Ma
  • Certifications - Performance : ISA-12.13.01|LEL CSA C22.2 No. 152
  • Datalogging Interval : 1 min
  • Datalogging Capable : Yes
  • Datalogging : Continuous Datalogging (6 Months for 5 Sensors at 1 Min Intervals, 24/7)|User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
  • Display Type : Monochrome Graphical LCD Display with Backlighting and Automatic Screen “Flip” Feature
  • Display Readout : Man Down Alarm On/Off; Visual Compliance Indicator; Battery Status; Datalogging On/Off; Wireless On/Off and Reception Quality|Real-Time Reading of Gas Concentrations; PID Measurement Gas and Correction Factor|STEL, TWA, Peak and Minimum Values
  • Display Matrix : 128 x 160
  • Display Included : Yes
  • Features & Benefits : Device Management with Honeywell SafetySuite|Easy Maintenance with Replaceable Sensors, Pump, and Plug-and-Play Battery|Highly Versatile and Customizable|Intelligent Sensors Store Calibration Data, so they can be Swapped in the Field|Large Graphical Display with Easy-to-Use, Icon-Driven User Interface|Over 25 Interchangeable Sensor Options, Including PID4 for VOCs, NDIR5 and Catalytic for Combustibles, and NDIR for CO2|Unmistakable Five-Way Local and Remote Wireless Notification of Alarm Conditions Including Man Down Alarm|Wireless Access to Real-Time Instrument Readings and Alarm Status from Any Location
  • User Options : 3 operation and programming keys (Mode, Y/+, and N/-). Multiple User Options can be selected|User-Configurable Datalogging Intervals (from 1 to 3,600 Secs)
  • Sampling Pump Range : 100ft (30m) meter
  • Sampling Pump Included : Yes
  • Sensor Type : PID, Electrochemical, Combustible LEL, NDIR, CO2 NDIR
  • Number of Sensors Included : 25
  • Warranty : 1 Year on All Other Sensors, Pump, Battery, and Other Consumable Parts|2 Years on Non-Consumable Components and Catalytic LEL Sensors|3 Years on CO and H2S Sensors|4 Years on Liq O2 Sensors
  • Wireless Technology : BLE
  • Wireless Enabled : Yes
  • Ingress Protection : IP65|IP65
  • Gas Type : NH3, CO, H2S, CL2, CLO2, ETO, HCHO, HCN,CH3-SH, NO, NO2, O2, PH3, SO2, VOC, LEL, CO2
  • External Calibration : Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Decibels : 95 decibel
  • Combustible : Yes
  • Wireless Range : MultiRAE Lite to EchoView Host, RAEMesh Reader or RAEPoint 660 ft (200m)|MultiRAE Lite to RAELink3 [Z1] Mesh Modem 330 ft (100m)|MultiRAE Lite to Wi-Fi Access Point - 330 ft (100m)
  • Wireless Network : EchoView Host-Based Closed-Loop System|ProRAE Guardian Real-Time Wireless Safety System
  • Wireless Approvals : CE RandTTE|FCC Part 15
  • Tests : Fully Automatic Bump Testing and Calibration with AutoRAE 2
  • Size : H: 7.6 in W: 3.8 in D: 2.6 in
  • Series Name : MultiRAE Lite Pumped
  • Sampling : Built-In Pump
  • Radio Module : Supports RM900A
  • Power Source : Battery
  • Model Number : PGM-6208
  • Languages : Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
  • Keypad Type : Automatic with AutoRAE 2 Test and Calibration System or Manual
  • Gases Detected : CO2, H2S, CO, SO2, O2
  • EMC/RFI : EMC Directive: 2004/108/EC
  • Communication and Data Download : Data Download and Instrument Set-Up and Upgrades on PC via Desktop Charging and PC Comm. Cradle, Travel Charger, or Autorae 2 Automatic Test and Calibration System|Wireless Data and Alarm Status Transmission via Built-In RF Modem (Optional)
  • Application : Chemical|Fire Overhaul|Food and Beverage|Oil and Gas (Downstream)|Pharmaceutical|Telecommunications|Waste Water Treatment
Data Sheet
Name
Description
File Size
Date
Size
MultiRAE Lite Diffused & Pumped Data Sheet
application/pdf 137.81 KB
7/27/2021
137.81 KB
Manuals and Guides
Name
Description
File Size
Date
Size
MultiRAE (Pumped Models) User's Guide - EN
application/pdf 898.78 KB
11/15/2023
898.78 KB
MultiRAE - User Guide
application/pdf 13.7 MB
4/11/2023
13.7 MB
MultiRAE User Guide
application/pdf 8.12 MB
7/15/2021
8.12 MB
Software
Name
Description
File Size
Date
Size
MultiRAE Sensor Firmware V 1.56.006 with signature
application/zip 264.62 KB
1/4/2024
264.62 KB
MultiRAE Application Firmware V 1.56.006 with signature
application/zip 1.4 MB
1/4/2024
1.4 MB
Brochure
Name
Description
File Size
Date
Size
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
10/28/2024
441.3 KB
Technical Note
Name
Description
File Size
Date
Size
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
application/pdf 976.3 KB
7/15/2021
976.3 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 750.26 KB
11/1/2022
750.26 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
Technical Note 141 Monitor Remote Control Functions
application/pdf 984.3 KB
8/3/2022
984.3 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
7/15/2021
620.4 KB
Certificate
Name
Description
File Size
Date
Size
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
MultiRAE Lite - IECEx Certificate of Conformity
application/pdf 155.39 KB
3/14/2023
155.39 KB
MultiRAE - EU Declaration of Conformity
application/pdf 212.27 KB
1/7/2022
212.27 KB
MultiRAE - Atex SIra EU Type Exam Certification
application/pdf 310.08 KB
1/7/2022
310.08 KB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
MultiRAE - CSA Certificate of Compliance
application/pdf 136.44 KB
1/7/2022
136.44 KB
Application Note
Name
Description
File Size
Date
Size
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
Application 202: The ABC®s Of Gases In The Industry
application/pdf 843.47 KB
7/27/2021
843.47 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
application/pdf 1 MB
7/15/2021
1 MB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
7/15/2021
901.23 KB
Name
Description
File Size
Date
Size
ToxiRAE & MultiRAE RMBLED CE Certificate of Component Conformity
application/pdf 116.75 KB
10/16/2024
116.75 KB
MultiRAE Sensor Firmware V 1.56.006 with signature
application/zip 264.62 KB
1/4/2024
264.62 KB
MultiRAE Application Firmware V 1.56.006 with signature
application/zip 1.4 MB
1/4/2024
1.4 MB
MultiRAE (Pumped Models) User's Guide - EN
application/pdf 898.78 KB
11/15/2023
898.78 KB
MultiRAE - User Guide
application/pdf 13.7 MB
4/11/2023
13.7 MB
MultiRAE - INMETRO Certificate of Conformity
application/pdf 472.03 KB
4/24/2023
472.03 KB
MultiRAE Lite - IECEx Certificate of Conformity
application/pdf 155.39 KB
3/14/2023
155.39 KB
MultiRAE Benzene, MeshGuard EC, AreaRAE Pro, MultiRAE Lite Pumped, QRAE 3, ToxiRAE Pro, MultiRAE, MultiRAE Pro, AreaRAE Plus, MultiRAE Lite Diffused Product Notice
application/pdf 125.12 KB
1/23/2024
125.12 KB
Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
application/pdf 655.59 KB
7/15/2021
655.59 KB
Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
application/pdf 911.54 KB
7/15/2021
911.54 KB
MultiRAE - EU Declaration of Conformity
application/pdf 212.27 KB
1/7/2022
212.27 KB
Technical Note 148 Defining The Interval Between Calibration Checks
application/pdf 839.32 KB
12/14/2022
839.32 KB
MultiRAE Lite Diffused & Pumped Data Sheet
application/pdf 137.81 KB
7/27/2021
137.81 KB
Technical Note 132 Upgrading Firmware On RAE Systems Instruments
application/pdf 820.7 KB
9/14/2022
820.7 KB
Technical Note 130 Setting Alarm Limits For Mixtures
application/pdf 788.83 KB
7/15/2021
788.83 KB
Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
application/pdf 839.29 KB
8/3/2022
839.29 KB
A Guideline for Pid Instrument Response
application/pdf 1.45 MB
8/3/2022
1.45 MB
MSI-Honeywell Connected Safety Solution
application/pdf 441.3 KB
10/28/2024
441.3 KB
Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
application/pdf 609.21 KB
7/15/2021
609.21 KB
Application Note 000: RAE Systems PID Overview
application/pdf 1.1 MB
7/15/2021
1.1 MB
MultiRAE - Atex SIra EU Type Exam Certification
application/pdf 310.08 KB
1/7/2022
310.08 KB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces RU
application/pdf 941.33 KB
8/4/2022
941.33 KB
Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
application/pdf 785.04 KB
11/1/2022
785.04 KB
Electrochemical Sensor Replacement & Maintenance Technical Note 151
application/pdf 976.3 KB
7/15/2021
976.3 KB
Technical Note 128 Formaldehyde (HCHO) Sensor In RAE Systems Instruments
application/pdf 750.26 KB
11/1/2022
750.26 KB
Application 202: The ABC®s Of Gases In The Industry
application/pdf 843.47 KB
7/27/2021
843.47 KB
Technical Note 114 Sensor Specifications and Cross-Sensitivities
application/pdf 795.02 KB
7/15/2021
795.02 KB
MultiRAE User Guide
application/pdf 8.12 MB
7/15/2021
8.12 MB
Application Note 206 Guide To Atmospheric Testing In Confined Spaces
application/pdf 1 MB
7/15/2021
1 MB
RM2400A EU Component of Conformity to Certificates
application/pdf 110.56 KB
1/3/2022
110.56 KB
MultiRAE - CSA Certificate of Compliance
application/pdf 136.44 KB
1/7/2022
136.44 KB
Technical Note 141 Monitor Remote Control Functions
application/pdf 984.3 KB
8/3/2022
984.3 KB
Application Note 218: Measurement Of Fumigants In The Food Storage Industry
application/pdf 901.23 KB
7/15/2021
901.23 KB
Technical Note 169 Theory And Operation Of NDIR Sensors
application/pdf 994.45 KB
8/3/2022
994.45 KB
MultiRAE Series Technical Note 106B
application/pdf 620.4 KB
7/15/2021
620.4 KB
Name
Date
Size
Showing 1 to 10 of 49 parts
Product Number
Part Number
Description
Leaf Category
Thumbnail
M01-4021-000
LABEL,HARD CASE,MULTIRAE LITE
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
M01-4021-000
LABEL,HARD CASE,MULTIRAE LITE
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-0003568-020
MR LTATXPMP Z0 SO2NO2Cl2NH3N-WS
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-0003568-020
MR LTATXPMP Z0 SO2NO2Cl2NH3N-WS
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-00C11FS-W20
MR LTATXPMP Z0 LELH2SCOLIQ O2WiFi
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-00C11FS-W20
MR LTATXPMP Z0 LELH2SCOLIQ O2WiFi
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-01068HK-020
MR LTAXPMP Z0H2SCl2NH3CH4SEtON-W
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-01068HK-020
MR LTAXPMP Z0H2SCl2NH3CH4SEtON-W
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-A2C1028-020
MR LTATXPMP Z0PIDLELCONH3N-WS
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-A2C1028-020
MR LTATXPMP Z0PIDLELCONH3N-WS
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-A2C102S-020
MR LTATXPMP Z0PIDLELCOO2N-WS
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA2-A2C102S-020
MR LTATXPMP Z0PIDLELCOO2N-WS
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-030
MR LTATXPMPALK
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-030
MR LTATXPMPALK
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-320
MR LTATXPMP 868M
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-320
MR LTATXPMP 868M
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-330
MR LTATXPMP868MALK
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-330
MR LTATXPMP868MALK
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-D30
MR LTATXPMPINDALK
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
MAA3-0000000-D30
MR LTATXPMPINDALK
https://s7d1.scene7.com/is/image/Honeywell65/his-rae-multirae-lite-pump-front-hires
Feedback