    XPT sampling system is an easily configurable sampling system that supports up to 2 channels of gas detections which can be serial or parallel configured. It accepts inputs from Searchpoint Optima Plus infrared point detectors, Sensepoint detectors, Sensepoint XCD detectors or XNX transmitters. Three different configurations of Searchpoint Optima Plus are available to suit the requirements of different solvent monitoring applications. The system can be plate or cabinet mounted and assembled with an injector or pump.

    Filters

    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    01-HP-SP2230
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered- injector Typ. 710200 incl. throttle check valve fitting
    01-HP-SP2230
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered- injector Typ. 710200 incl. throttle check valve fitting
    01-HP-SP2231
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Sample gas pump P2.2-ATEX, 230 V 50 Hz
    01-HP-SP2231
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Sample gas pump P2.2-ATEX, 230 V 50 Hz
    01-HP-SR1130
    Sample System Searchpoint Optima (ATEX M25) for integration of one sensor mounted in series, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Injector Typ. 710200 incl. throttle check valve fitting
    01-HP-SR1130
    Sample System Searchpoint Optima (ATEX M25) for integration of one sensor mounted in series, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Injector Typ. 710200 incl. throttle check valve fitting
    01-HP-SR1131
    Sample System Searchpoint Optima (ATEX M25) for integration of one sensor mounted in series, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Sample gas pump P2.2-ATEX, 230 V 50 Hz
    01-HP-SR1131
    Sample System Searchpoint Optima (ATEX M25) for integration of one sensor mounted in series, Type Optima Plus consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Sample gas pump P2.2-ATEX, 230 V 50 Hz
    01-HZ-SP2220
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Z consisting of: Housing 500 x 500 x 200 mm, sheet metal, covered. Injector Typ. 710200 incl. throttle check valve fitting
    01-HZ-SP2220
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Z consisting of: Housing 500 x 500 x 200 mm, sheet metal, covered. Injector Typ. 710200 incl. throttle check valve fitting
    01-HZ-SP2230
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Z consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Injector Typ. 710200 incl. throttle check valve fitting
    01-HZ-SP2230
    Sample System Searchpoint Optima (ATEX M25) mounted in parallel, Type Optima Z consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Injector Typ. 710200 incl. throttle check valve fitting
    01-HZ-SR1120
    Sample System Searchpoint Optima (ATEX M25) for integration of one sensor mounted in series, Type Optima Z consisting of: Housing 500 x 500 x 200 mm, sheet metal, covered, Injector Typ. 710200 incl. throttle check valve fitting
    01-HZ-SR1120
    Sample System Searchpoint Optima (ATEX M25) for integration of one sensor mounted in series, Type Optima Z consisting of: Housing 500 x 500 x 200 mm, sheet metal, covered, Injector Typ. 710200 incl. throttle check valve fitting
    02-HL-SP2231
    Sample System Sensepoint TOXLEL mounted in parallel, Type Sensepoint-LEL consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Sample gas pump P2.2-ATEX, 230 V 50 Hz
    02-HL-SP2231
    Sample System Sensepoint TOXLEL mounted in parallel, Type Sensepoint-LEL consisting of: Housing 600 x 400 x 260 mm, sheet metal, covered, Sample gas pump P2.2-ATEX, 230 V 50 Hz
    06-HP-CR1140
    SIL2-sample system according to EN1539 Performance level d for XNX Transmitter with Optima Plus cosisting of: Mounting plate 570 x 543 mm, Injector Typ. 710200 incl. throttle check valve fitting
    06-HP-CR1140
    SIL2-sample system according to EN1539 Performance level d for XNX Transmitter with Optima Plus cosisting of: Mounting plate 570 x 543 mm, Injector Typ. 710200 incl. throttle check valve fitting
    06-HP-CR1150
    SIL2-sample system according to EN1539 Performance level d for XNX Transmitter with Optima Plus consisting of: Sheet steel cabinet 600 x 600 mm, Injector Typ. 710200 incl. throttle check valve fitting
    06-HP-CR1150