    The ppbRAE 3000+ is a best-of-breed monitor trusted by many of the world’s leaders in CBRNE, HazMat Response, Civil Defense, Oil & Gas, and other hazardous environments. Using a 3rd generation photoionization detector (PID) and built-in correction factors for more than 200 compounds, the ppbRAE 3000+ is one of the most advanced VOC monitors for parts-per-billion (ppb) detection. It measures the presence of VOCs from 1ppb-10,000ppm with a three-second response time. Optional built-in Mesh Radio enables real-time monitoring of instrument readings wirelessly. Another option is Bluetooth, which can relay readings and alarm status up to 2 miles to a RAELink 3 wireless transmitter. And a rugged housing, large display, and large keys that can be operated with three layers of gloves all make for a unit that’s easy to use and maintain.A rugged housing, large display, and large keys that can be operated with three layers of gloves all make for a unit that’s easy to use and maintain.ppbRAE 3000 + is solution oriented through multiple connected options. A dedicated mobile APP has been developed for survey applications. Instrument is also available with real time connectivity which can relay readings and alarm status up to 2 miles to a RAELink 3 wireless transmitter.Features and Benefits:
    • Measures from 1ppb up to 10,000ppb
    • 3-second response time
    • Humidity compensation
    • Optional Mesh Radio for ConneXt compatibility
    • Optional BLE Module
    • Optional built-in Bluetooth transmitter that transmits real-time data up to 2 miles with RAELink3 wireless router
    • Sample pump draws from up to 100 feet
    • Correction factors for more than 350 compounds
    • Large display reports gas type, correction factor, concentration
    • Rugged housing for harsh environments
    • Sensor and lamp auto-cleaning
    • Built-in flashlight
    • Multi-language capability – up to 10 languages
    • MIL-STD-810F certified rugged housing for harsh environments
    • Patented PID lamp auto-cleaning
    • Patented Reflex PID Technology™
    Application:
    • CBRNE
    • Decontamination
    • Environmental Cleanups/ Remediation
    • Hazmat Response
    • Indoor Air Quality
    • Plant Shutdown & Turn-Around
    • Urban Search & Rescue
    • Venue Protection
    • Worker Exposure
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Marca

    • Marca
      • RAE

    Dimensiones

    • Peso
      • 738

    Categoría

    • Subcategoría
      • Gas premium

    Dimension & Weight

    • Tamaño del instrumento
      • 25.5 x 7.6 x 6.4 cm (10” de largo x 3.0” de ancho x 2.5” de alto)

    Intervalo

    • Rango de humedad
      • 0%-95% percent
    • Rango del sensor
      • COV (0-10000ppm)

    Alarm

    • Función de alarma
      • Audible, visual, vibratorio

    Battery & Charging

    • Tiempo de funcionamiento de la batería
      • 12-16 hours

    Certifications

    • Estándares
      • • EE. UU. y Canadá: UL, cUL, clasificado como intrínsecamente seguro para su uso en la clase I, división

    Datalogging

    • Registro de datos
      • Estándar 6 meses a intervalos de un minuto

    Features & Benefits

    • Ventajas
      • • Tiempo de respuesta de 3 segundos

    Opciones

    • Opciones de usuario
      • • Alarmas enclavadas con anulación manual o reinicio automático

    Sampling

    • Gama de bombas de muestreo
      • 100 pies (30 m) meter

    Warranty

    • Garantía
      • Garantía de 3 años para lámpara de 10.6 eV
      • Garantía de 3 años para lámpara de 10.6 eV,

    Wireless

    • Tecnología inalámbrica
      • MALLA, BLE
      • MESH, BLE

    Additional Specifications

    • Protección contra el ingreso
      • IP65
    • Tipo de gas
      • VOC

    Otros

    • Temperatura mínima
      • -20
    • Temperatura máxima
      • 50

    Marca

    • Marca
      • RAE

    Dimensiones

    • Peso
      • 738

    Categoría

    • Subcategoría
      • Gas premium

    Dimension & Weight

    • Tamaño del instrumento
      • 25.5 x 7.6 x 6.4 cm (10” de largo x 3.0” de ancho x 2.5” de alto)

    Intervalo

    • Rango de humedad
      • 0%-95% percent
    • Rango del sensor
      • COV (0-10000ppm)

    Alarm

    • Función de alarma
      • Audible, visual, vibratorio

    Battery & Charging

    • Tiempo de funcionamiento de la batería
      • 12-16 hours

    Certifications

    • Estándares
      • • EE. UU. y Canadá: UL, cUL, clasificado como intrínsecamente seguro para su uso en la clase I, división

    Datalogging

    • Registro de datos
      • Estándar 6 meses a intervalos de un minuto

    Features & Benefits

    • Ventajas
      • • Tiempo de respuesta de 3 segundos

    Opciones

    • Opciones de usuario
      • • Alarmas enclavadas con anulación manual o reinicio automático

    Sampling

    • Gama de bombas de muestreo
      • 100 pies (30 m) meter

    Warranty

    • Garantía
      • Garantía de 3 años para lámpara de 10.6 eV
      • Garantía de 3 años para lámpara de 10.6 eV,

    Wireless

    • Tecnología inalámbrica
      • MALLA, BLE
      • MESH, BLE

    Additional Specifications

    • Protección contra el ingreso
      • IP65
    • Tipo de gas
      • VOC

    Otros

    • Temperatura mínima
      • -20
    • Temperatura máxima
      • 50
    • Marca : RAE
    • Temperatura mínima : -20
    • Peso : 738
    • Temperatura máxima : 50
    • Subcategoría : Gas premium
    • Tamaño del instrumento : 25.5 x 7.6 x 6.4 cm (10” de largo x 3.0” de ancho x 2.5” de alto)
    • Rango de humedad : 0%-95% percent
    • Rango del sensor : COV (0-10000ppm)
    • Función de alarma : Audible, visual, vibratorio
    • Tiempo de funcionamiento de la batería : 12-16 hours
    • Estándares : • EE. UU. y Canadá: UL, cUL, clasificado como intrínsecamente seguro para su uso en la clase I, división
    • Registro de datos : Estándar 6 meses a intervalos de un minuto
    • Ventajas : • Tiempo de respuesta de 3 segundos
    • Opciones de usuario : • Alarmas enclavadas con anulación manual o reinicio automático
    • Gama de bombas de muestreo : 100 pies (30 m) meter
    • Garantía : Garantía de 3 años para lámpara de 10.6 eV|Garantía de 3 años para lámpara de 10.6 eV,
    • Tecnología inalámbrica : MALLA, BLE|MESH, BLE
    • Protección contra el ingreso : IP65
    • Tipo de gas : VOC
    Ficha técnica
    Nombre
    Descripción
    Tamaño del archivo
    Fecha
    Tamaño
    ppbRAE 3000 + Data Sheet - RU
    application/pdf 401.41 KB
    7/18/2021
    401.41 KB
    ppbRAE 3000 + Data Sheet - PT
    application/pdf 344.72 KB
    7/18/2021
    344.72 KB
    ppbRAE 3000 + Data Sheet - FR
    application/pdf 344.63 KB
    7/18/2021
    344.63 KB
    ppbRAE 3000 + Data Sheet - NL
    application/pdf 343.12 KB
    7/18/2021
    343.12 KB
    ppbRAE 3000 + Data Sheet - DE
    application/pdf 345.82 KB
    7/18/2021
    345.82 KB
    ppbRAE 3000 + Data Sheet - ES
    application/pdf 343.33 KB
    7/18/2021
    343.33 KB
    ppbRAE 3000 + Data Sheet - EN
    application/pdf 2.68 MB
    7/18/2021
    2.68 MB
    ppbRAE 3000 + Data Sheet - IT
    application/pdf 342.08 KB
    7/18/2021
    342.08 KB
    Manuales y Guía
    Nombre
    Descripción
    Tamaño del archivo
    Fecha
    Tamaño
    3G PID User Guide - DE
    application/pdf 7.64 MB
    7/18/2021
    7.64 MB
    3000+ Series PID Quick Start Guide - EN
    application/pdf 737.56 KB
    4/23/2024
    737.56 KB
    ppbRAE 3000 plus - User Manual
    application/pdf 6.82 MB
    6/6/2023
    6.82 MB
    3000+ Series PID Quick Start Guide - RU
    application/pdf 784.44 KB
    7/18/2021
    784.44 KB
    3000+ Series PID Quick Start Guide - DE
    application/pdf 739.46 KB
    7/18/2021
    739.46 KB
    3G PID User Guide - PT
    application/pdf 7.58 MB
    7/18/2021
    7.58 MB
    3G PID User Guide - FR
    application/pdf 7.57 MB
    7/18/2021
    7.57 MB
    3G PID User Guide - NL
    application/pdf 7.5 MB
    7/18/2021
    7.5 MB
    3G PID User Guide - ES
    application/pdf 7.53 MB
    7/18/2021
    7.53 MB
    3G PID User Guide - EN
    application/pdf 7.52 MB
    7/18/2021
    7.52 MB
    3G PID User's Guide - PL
    application/pdf 3.91 MB
    7/18/2021
    3.91 MB
    3000+ Series PID Quick Start Guide - NL
    application/pdf 736.75 KB
    7/18/2021
    736.75 KB
    3G PID User Guide - IT
    application/pdf 7.57 MB
    7/18/2021
    7.57 MB
    3000+ Series PID Quick Start Guide - PT
    application/pdf 736.66 KB
    7/18/2021
    736.66 KB
    3G PID User Guide - RU
    application/pdf 7.71 MB
    7/18/2021
    7.71 MB
    3000+ Series PID Quick Start Guide - FR
    application/pdf 736.61 KB
    7/18/2021
    736.61 KB
    3000+ Series PID Quick Start Guide - ES
    application/pdf 735.47 KB
    7/18/2021
    735.47 KB
    3000+ Series PID Quick Start Guide - IT
    application/pdf 734.57 KB
    7/18/2021
    734.57 KB
    Nota técnica
    Nombre
    Descripción
    Tamaño del archivo
    Fecha
    Tamaño
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/18/2021
    950.72 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    7/18/2021
    1.26 MB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    7/18/2021
    1.09 MB
    3GPID+ Technical Note
    application/pdf 436.09 KB
    7/18/2021
    436.09 KB
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    application/pdf 813.81 KB
    7/18/2021
    813.81 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    7/18/2021
    790.79 KB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/18/2021
    926.7 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/18/2021
    788.83 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    PID Lamp Characteristics Technical Note 124
    application/pdf 768.24 KB
    7/18/2021
    768.24 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/18/2021
    930.69 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/18/2021
    911.54 KB
    Nota de aplicación
    Nombre
    Descripción
    Tamaño del archivo
    Fecha
    Tamaño
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    7/18/2021
    836.36 KB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/18/2021
    964.88 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/18/2021
    1.1 MB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/18/2021
    655.59 KB
    Otros
    Nombre
    Descripción
    Tamaño del archivo
    Fecha
    Tamaño
    3G PID User Guide - EN
    application/pdf 4.11 MB
    7/18/2021
    4.11 MB
    Nombre
    Descripción
    Tamaño del archivo
    Fecha
    Tamaño
    3G PID User Guide - DE
    application/pdf 7.64 MB
    7/18/2021
    7.64 MB
    3000+ Series PID Quick Start Guide - EN
    application/pdf 737.56 KB
    4/23/2024
    737.56 KB
    ppbRAE 3000 plus - User Manual
    application/pdf 6.82 MB
    6/6/2023
    6.82 MB
    3G PID User Guide - EN
    application/pdf 4.11 MB
    7/18/2021
    4.11 MB
    3000+ Series PID Quick Start Guide - RU
    application/pdf 784.44 KB
    7/18/2021
    784.44 KB
    Application Note 214: Environmental Applications For PIDs
    application/pdf 836.36 KB
    7/18/2021
    836.36 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/18/2021
    950.72 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    ppbRAE 3000 + Data Sheet - RU
    application/pdf 401.41 KB
    7/18/2021
    401.41 KB
    3000+ Series PID Quick Start Guide - DE
    application/pdf 739.46 KB
    7/18/2021
    739.46 KB
    3G PID User Guide - PT
    application/pdf 7.58 MB
    7/18/2021
    7.58 MB
    3G PID User Guide - FR
    application/pdf 7.57 MB
    7/18/2021
    7.57 MB
    3G PID User Guide - NL
    application/pdf 7.5 MB
    7/18/2021
    7.5 MB
    Technical Note 170 USB To Serial Port Adapter
    application/pdf 1.26 MB
    7/18/2021
    1.26 MB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/18/2021
    964.88 KB
    ppbRAE 3000 + Data Sheet - PT
    application/pdf 344.72 KB
    7/18/2021
    344.72 KB
    3G PID User Guide - ES
    application/pdf 7.53 MB
    7/18/2021
    7.53 MB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    7/18/2021
    1.09 MB
    3GPID+ Technical Note
    application/pdf 436.09 KB
    7/18/2021
    436.09 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/18/2021
    1.1 MB
    ppbRAE 3000 + Data Sheet - FR
    application/pdf 344.63 KB
    7/18/2021
    344.63 KB
    3G PID User Guide - EN
    application/pdf 7.52 MB
    7/18/2021
    7.52 MB
    3G PID User's Guide - PL
    application/pdf 3.91 MB
    7/18/2021
    3.91 MB
    ppbRAE 3000 + Data Sheet - NL
    application/pdf 343.12 KB
    7/18/2021
    343.12 KB
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    application/pdf 813.81 KB
    7/18/2021
    813.81 KB
    3000+ Series PID Quick Start Guide - NL
    application/pdf 736.75 KB
    7/18/2021
    736.75 KB
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    application/pdf 790.79 KB
    7/18/2021
    790.79 KB
    3G PID User Guide - IT
    application/pdf 7.57 MB
    7/18/2021
    7.57 MB
    Lithium-Ion Batteries Technical Note 166
    application/pdf 926.7 KB
    7/18/2021
    926.7 KB
    3000+ Series PID Quick Start Guide - PT
    application/pdf 736.66 KB
    7/18/2021
    736.66 KB
    ppbRAE 3000 + Data Sheet - DE
    application/pdf 345.82 KB
    7/18/2021
    345.82 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/18/2021
    788.83 KB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/18/2021
    655.59 KB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    11/1/2022
    820.7 KB
    3G PID User Guide - RU
    application/pdf 7.71 MB
    7/18/2021
    7.71 MB
    PID Lamp Characteristics Technical Note 124
    application/pdf 768.24 KB
    7/18/2021
    768.24 KB
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/18/2021
    930.69 KB
    3000+ Series PID Quick Start Guide - FR
    application/pdf 736.61 KB
    7/18/2021
    736.61 KB
    3000+ Series PID Quick Start Guide - ES
    application/pdf 735.47 KB
    7/18/2021
    735.47 KB
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    application/pdf 911.54 KB
    7/18/2021
    911.54 KB
    ppbRAE 3000 + Data Sheet - ES
    application/pdf 343.33 KB
    7/18/2021
    343.33 KB
    3000+ Series PID Quick Start Guide - IT
    application/pdf 734.57 KB
    7/18/2021
    734.57 KB
    ppbRAE 3000 + Data Sheet - EN
    application/pdf 2.68 MB
    7/18/2021
    2.68 MB
    ppbRAE 3000 + Data Sheet - IT
    application/pdf 342.08 KB
    7/18/2021
    342.08 KB
    Nombre
    Descripción
    Tamaño del archivo
    Fecha
    Tamaño
    ppbRAE 3000 + Data Sheet - RU
    401.41 KB
    7/18/2021
    ppbRAE 3000 + Data Sheet - PT
    344.72 KB
    7/18/2021
    ppbRAE 3000 + Data Sheet - FR
    344.63 KB
    7/18/2021
    ppbRAE 3000 + Data Sheet - NL
    343.12 KB
    7/18/2021
    ppbRAE 3000 + Data Sheet - DE
    345.82 KB
    7/18/2021
    ppbRAE 3000 + Data Sheet - ES
    343.33 KB
    7/18/2021
    ppbRAE 3000 + Data Sheet - EN
    2.68 MB
    7/18/2021
    ppbRAE 3000 + Data Sheet - IT
    342.08 KB
    7/18/2021
    3G PID User Guide - DE
    7.64 MB
    7/18/2021
    3000+ Series PID Quick Start Guide - EN
    737.56 KB
    4/23/2024
    ppbRAE 3000 plus - User Manual
    6.82 MB
    6/6/2023
    3000+ Series PID Quick Start Guide - RU
    784.44 KB
    7/18/2021
    3000+ Series PID Quick Start Guide - DE
    739.46 KB
    7/18/2021
    3G PID User Guide - PT
    7.58 MB
    7/18/2021
    3G PID User Guide - FR
    7.57 MB
    7/18/2021
    3G PID User Guide - NL
    7.5 MB
    7/18/2021
    3G PID User Guide - ES
    7.53 MB
    7/18/2021
    3G PID User Guide - EN
    7.52 MB
    7/18/2021
    3G PID User's Guide - PL
    3.91 MB
    7/18/2021
    3000+ Series PID Quick Start Guide - NL
    736.75 KB
    7/18/2021
    3G PID User Guide - IT
    7.57 MB
    7/18/2021
    3000+ Series PID Quick Start Guide - PT
    736.66 KB
    7/18/2021
    3G PID User Guide - RU
    7.71 MB
    7/18/2021
    3000+ Series PID Quick Start Guide - FR
    736.61 KB
    7/18/2021
    3000+ Series PID Quick Start Guide - ES
    735.47 KB
    7/18/2021
    3000+ Series PID Quick Start Guide - IT
    734.57 KB
    7/18/2021
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    950.72 KB
    7/18/2021
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Technical Note 170 USB To Serial Port Adapter
    1.26 MB
    7/18/2021
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    1.09 MB
    7/18/2021
    3GPID+ Technical Note
    436.09 KB
    7/18/2021
    Technical Note 118 Using RAE Systems PIDs For Measuring Soil Headspace And In Soil Vapor Extractions
    813.81 KB
    7/18/2021
    Technical Note 122 Compliance of RAE Systems PIDs with EPA Method
    790.79 KB
    7/18/2021
    Lithium-Ion Batteries Technical Note 166
    926.7 KB
    7/18/2021
    Technical Note 130 Setting Alarm Limits For Mixtures
    788.83 KB
    7/18/2021
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    11/1/2022
    PID Lamp Characteristics Technical Note 124
    768.24 KB
    7/18/2021
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    930.69 KB
    7/18/2021
    Technical Note 140 The Effect Of Extension Tubing Volume And Vacuum On Sample Flow For RAE Systems Instruments
    911.54 KB
    7/18/2021
    Application Note 214: Environmental Applications For PIDs
    836.36 KB
    7/18/2021
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    964.88 KB
    7/18/2021
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    7/18/2021
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    655.59 KB
    7/18/2021
    3G PID User Guide - EN
    4.11 MB
    7/18/2021
    Product Number
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list
    059-9140-000
    https://s7d1.scene7.com/is/image/Honeywell65/ppbRAE3000
    059-9140-000
    https://s7d1.scene7.com/is/image/Honeywell65/ppbRAE3000
    059-9140-100
    https://s7d1.scene7.com/is/image/Honeywell65/ppbRAE3000
    059-9140-100
    https://s7d1.scene7.com/is/image/Honeywell65/ppbRAE3000