/content/sps/us/en/search-results.html

    Transportable Area Monitoring

    AreaRAE Rapid Deployment Kit (RDK)

    Rapidly deployable wireless gas detection for hazardous threats

    Overview
    Assess and respond quickly to the release of toxic and radioactive substances with this turnkey system. The AreaRAE Rapid Deployment Kit (RDK) includes four versatile GPS-enabled AreaRAE monitors, RAEMet (AreaRAE Pro RDK only), a RAELink3 wireless router built in and all the necessary accessories for field operation. With The RDK, you have everything you need to create a perimeter and set up a command station up to two miles from the site. It all fits into a military-grade protective case, which charges all the batteries during storage.Features and Benefits:
    • Turnkey system for detection of hazardous toxic chemicals and radioactivity
    • Includes 4 AreaRAE monitors and RDK Ruggedized Host Controller (Not the case for AreaRAE Plus / AreaRAE Pro)
    • Up to 2 miles (3km) range for ISM 900Mhz
    • Up to 1.2 miles (2km) range for ISM 2.4Ghz
    • Push data to any location via ProRAE Guardian
    • Military-grade case
    • Device batteries charged during storage
    • Easy to transport
    • Standard GPS enable units (AreaRAE Plus / AreaRAE Pro) and Optional for other monitors
    • Scales up to 64 remote devices
    Application:
    • CBRNE
    • Clandestine Labs
    • Emergency Response
    • Environmental Cleanups/ Remediation
    • Fence Line Monitoring
    • Hazmat Response
    • Plant Shutdown & Turn-Around
    • Urban Search & Rescue
    • Venue Protection
    Even the best products deserve expert maintenance!

    Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

    Explore our fixed, portable, and high-tech support services now!

    Specifications

    Brand

    • Brand
      • RAE

    Sampling

    • Sampling Pump Range
      • 100ft (30m)

    Category

    • Sub-Category
      • Transportable

    Dimension & Weight

    • Instrument Size
      • 12.36” x 12.04” x 6.53”

    Range

    • Humidity Range
      • 0%-95% percent
    • Sensor Range
      • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm), Gamma (0.01 μSv/h to 0.2 mSv/h)

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-20 hours

    Certifications

    • Standards & Certifications
      • US and Canada: Class 1, Division 2, Groups A, B, C, D

    Datalogging

    • Datalogging
      • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

    Features & Benefits

    • Features & Benefits
      • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat

    Options

    • User Options
      • 3 operation and programming keys

    Warranty

    • Warranty
      • Four years for O2 Liquid Oxygen sensors

    Wireless

    • Wireless Technology
      • BLE, MESH, WiFi

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma

    Others

    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Maximum Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius
    • Weight
      • 14.33 US Pound
      • 6.5 kilogram

    Brand

    • Brand
      • RAE

    Sampling

    • Sampling Pump Range
      • 100ft (30m)

    Category

    • Sub-Category
      • Transportable

    Dimension & Weight

    • Instrument Size
      • 12.36” x 12.04” x 6.53”

    Range

    • Humidity Range
      • 0%-95% percent
    • Sensor Range
      • VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm), Gamma (0.01 μSv/h to 0.2 mSv/h)

    Alarm

    • Alarm Type
      • Audible, Visual, Vibrating

    Battery & Charging

    • Battery Run Time
      • 12-20 hours

    Certifications

    • Standards & Certifications
      • US and Canada: Class 1, Division 2, Groups A, B, C, D

    Datalogging

    • Datalogging
      • Continuous data logging (90 days for 7 gas sensors, 1 Gamma

    Features & Benefits

    • Features & Benefits
      • Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat

    Options

    • User Options
      • 3 operation and programming keys

    Warranty

    • Warranty
      • Four years for O2 Liquid Oxygen sensors

    Wireless

    • Wireless Technology
      • BLE, MESH, WiFi

    Additional Specifications

    • Ingress Protection
      • IP65
    • Gas Type
      • VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma

    Others

    • Minimum Temperature
      • -20 degree Celsius
      • -4 degree Fahrenheit
    • Maximum Temperature
      • 140 degree Fahrenheit
      • 60 degree Celsius
    • Weight
      • 14.33 US Pound
      • 6.5 kilogram
    • Brand : RAE
    • Sampling Pump Range : 100ft (30m)
    • Minimum Temperature : -20 degree Celsius|-4 degree Fahrenheit
    • Maximum Temperature : 140 degree Fahrenheit|60 degree Celsius
    • Weight : 14.33 US Pound|6.5 kilogram
    • Sub-Category : Transportable
    • Instrument Size : 12.36” x 12.04” x 6.53”
    • Humidity Range : 0%-95% percent
    • Sensor Range : VOC (0-2000ppm), LEL (0-100%LEL), CO2 (0-50000ppm), NH3 (0-100ppm), CO (0-2000ppm), Cl2 (0-50ppm), ETO (0-500ppm), H2 (0-2000ppm), HCL (0-15ppm), HCN (0-50ppm), HF (0.5-10ppm), H2S (0-1000ppm), O2 (0-30%), SO2 (0-20ppm), NO (0-250ppm), NO2 (0-20ppm), PH3 (0-20ppm), Gamma (0.01 μSv/h to 0.2 mSv/h)
    • Alarm Type : Audible, Visual, Vibrating
    • Battery Run Time : 12-20 hours
    • Standards & Certifications : US and Canada: Class 1, Division 2, Groups A, B, C, D
    • Datalogging : Continuous data logging (90 days for 7 gas sensors, 1 Gamma
    • Features & Benefits : Delivers real-time readings to Honeywell’s remote monitoring software, so you can instantly determine the location and severity of a threat
    • User Options : 3 operation and programming keys
    • Warranty : Four years for O2 Liquid Oxygen sensors
    • Wireless Technology : BLE, MESH, WiFi
    • Ingress Protection : IP65
    • Gas Type : VOC, LEL, CO2, NH3, CO, Cl2, ETO, H2, HCL, HCN, HF, H2S, O2, SO2, NO, NO2, PH3, Gamma
    Data Sheet
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Pro Data Sheet
    application/pdf 537.7 KB
    7/15/2021
    537.7 KB
    AreaRAE Plus Datasheet
    application/pdf 569.87 KB
    7/15/2021
    569.87 KB
    Manuals and Guides
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Plus & AreaRAE Pro User's Guide
    application/pdf 5.65 MB
    1/4/2022
    5.65 MB
    AreaRAE Plus & AreaRAE Pro QuickStart Guide
    application/pdf 689.87 KB
    1/4/2022
    689.87 KB
    Brochure
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Pro Brochure
    application/pdf 2.87 MB
    7/15/2021
    2.87 MB
    AreaRAE Plus Brochure
    application/pdf 3.23 MB
    7/15/2021
    3.23 MB
    Technical Note
    Name
    Description
    File Size
    Date
    Size
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    application/pdf 884.91 KB
    7/15/2021
    884.91 KB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    application/pdf 787.55 KB
    7/15/2021
    787.55 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    Technical Note 163 Addressing PID Instruments Moisture Sensitivity
    application/pdf 944.51 KB
    7/15/2021
    944.51 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    9/14/2022
    820.7 KB
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    application/pdf 1.08 MB
    7/15/2021
    1.08 MB
    Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
    application/pdf 1.02 MB
    7/15/2021
    1.02 MB
    White Paper
    Name
    Description
    File Size
    Date
    Size
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    application/pdf 949.42 KB
    7/15/2021
    949.42 KB
    Application Note
    Name
    Description
    File Size
    Date
    Size
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Application Note 228 - Facility and Venue Protection
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    application/pdf 826.34 KB
    7/15/2021
    826.34 KB
    Measurement Of PGMEA Using Photoionization Detectors_12-11
    application/pdf 750.69 KB
    7/15/2021
    750.69 KB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    Application Note 215: Gas Detection In The Marine Industries
    application/pdf 889.61 KB
    7/15/2021
    889.61 KB
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    application/pdf 831.7 KB
    7/15/2021
    831.7 KB
    Name
    Description
    File Size
    Date
    Size
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    application/pdf 930.69 KB
    7/15/2021
    930.69 KB
    AreaRAE Plus & AreaRAE Pro User's Guide
    application/pdf 5.65 MB
    1/4/2022
    5.65 MB
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    application/pdf 655.59 KB
    7/15/2021
    655.59 KB
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    application/pdf 884.91 KB
    7/15/2021
    884.91 KB
    AreaRAE Pro Brochure
    application/pdf 2.87 MB
    7/15/2021
    2.87 MB
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    application/pdf 609.21 KB
    7/15/2021
    609.21 KB
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    application/pdf 839.29 KB
    8/3/2022
    839.29 KB
    Technical Note 148 Defining The Interval Between Calibration Checks
    application/pdf 839.32 KB
    12/14/2022
    839.32 KB
    Application Note 000: RAE Systems PID Overview
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    application/pdf 1.07 MB
    7/15/2021
    1.07 MB
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    application/pdf 949.42 KB
    7/15/2021
    949.42 KB
    Application Note 228 - Facility and Venue Protection
    application/pdf 1.1 MB
    7/15/2021
    1.1 MB
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    application/pdf 826.34 KB
    7/15/2021
    826.34 KB
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    application/pdf 785.04 KB
    11/1/2022
    785.04 KB
    Measurement Of PGMEA Using Photoionization Detectors_12-11
    application/pdf 750.69 KB
    7/15/2021
    750.69 KB
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    application/pdf 787.55 KB
    7/15/2021
    787.55 KB
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    application/pdf 814.89 KB
    7/15/2021
    814.89 KB
    Technical Note 130 Setting Alarm Limits For Mixtures
    application/pdf 788.83 KB
    7/15/2021
    788.83 KB
    AreaRAE Pro Data Sheet
    application/pdf 537.7 KB
    7/15/2021
    537.7 KB
    Application Note 203: PIDs As HazMat Response Tools
    application/pdf 1.26 MB
    7/15/2021
    1.26 MB
    Technical Note 163 Addressing PID Instruments Moisture Sensitivity
    application/pdf 944.51 KB
    7/15/2021
    944.51 KB
    AreaRAE Plus & AreaRAE Pro QuickStart Guide
    application/pdf 689.87 KB
    1/4/2022
    689.87 KB
    Technical Note 144 Handling LEL Sensor Poisons
    application/pdf 802.28 KB
    8/3/2022
    802.28 KB
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    application/pdf 964.88 KB
    7/15/2021
    964.88 KB
    A Guideline for Pid Instrument Response
    application/pdf 1.45 MB
    11/1/2022
    1.45 MB
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    application/pdf 795.02 KB
    7/15/2021
    795.02 KB
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    application/pdf 950.72 KB
    7/15/2021
    950.72 KB
    AreaRAE Plus Datasheet
    application/pdf 569.87 KB
    7/15/2021
    569.87 KB
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    application/pdf 1.09 MB
    2/8/2022
    1.09 MB
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    application/pdf 820.7 KB
    9/14/2022
    820.7 KB
    AreaRAE Plus Brochure
    application/pdf 3.23 MB
    7/15/2021
    3.23 MB
    Application Note 215: Gas Detection In The Marine Industries
    application/pdf 889.61 KB
    7/15/2021
    889.61 KB
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    application/pdf 1.08 MB
    7/15/2021
    1.08 MB
    Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
    application/pdf 1.02 MB
    7/15/2021
    1.02 MB
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    application/pdf 831.7 KB
    7/15/2021
    831.7 KB
    Name
    Description
    File Size
    Date
    Size
    AreaRAE Pro Data Sheet
    537.7 KB
    7/15/2021
    AreaRAE Plus Datasheet
    569.87 KB
    7/15/2021
    AreaRAE Plus & AreaRAE Pro User's Guide
    5.65 MB
    1/4/2022
    AreaRAE Plus & AreaRAE Pro QuickStart Guide
    689.87 KB
    1/4/2022
    AreaRAE Pro Brochure
    2.87 MB
    7/15/2021
    AreaRAE Plus Brochure
    3.23 MB
    7/15/2021
    Technical Note 165 Combating Drift In Portable And Fixed PIDs
    930.69 KB
    7/15/2021
    Technical Note 159 Chemical Warfare Agent Measurements By PID
    884.91 KB
    7/15/2021
    Technical Note 156 Correction Factors For Combustible Gas LEL Sensors 20022016
    609.21 KB
    7/15/2021
    Technical Note 152 Effects Of Operating Conditions On Oxygen Sensors
    839.29 KB
    8/3/2022
    Technical Note 148 Defining The Interval Between Calibration Checks
    839.32 KB
    12/14/2022
    Technical Note 121 CO Sensor Cross Sensitivity And Removal With A Charcoal Filter
    785.04 KB
    11/1/2022
    Technical Note 146 Turning On UV Lamps In A PID Monitor
    787.55 KB
    7/15/2021
    Technical Note 174Decontamination Procedures For Monitors Exposed To Chemical Warfare Agents
    814.89 KB
    7/15/2021
    Technical Note 130 Setting Alarm Limits For Mixtures
    788.83 KB
    7/15/2021
    Technical Note 163 Addressing PID Instruments Moisture Sensitivity
    944.51 KB
    7/15/2021
    Technical Note 144 Handling LEL Sensor Poisons
    802.28 KB
    8/3/2022
    A Guideline for Pid Instrument Response
    1.45 MB
    11/1/2022
    Technical Note 114 Sensor Specifications and Cross-Sensitivities
    795.02 KB
    7/15/2021
    Technical Note 158_Conversion Of PID Readings To Methane Equivalent Or Hexane Equivalent FID Response
    950.72 KB
    7/15/2021
    Technical Note 178 Humidity Filtering II Tube For PID Measurements In Humid Environments
    1.09 MB
    2/8/2022
    Technical Note 132 Upgrading Firmware On RAE Systems Instruments
    820.7 KB
    9/14/2022
    Moisture Exchange Tubes For Humidity Control Of Test Gases Technical Note 157
    1.08 MB
    7/15/2021
    Proper Use Of Dilution Fittings On Pumped Monitors Technical Note 167
    1.02 MB
    7/15/2021
    Application Note 204 - Pulp & Paper: Measuring Turpentine & ClO2
    949.42 KB
    7/15/2021
    Application Note 201: Measuring Ammonia (NH3) With Photoionization Detectors
    655.59 KB
    7/15/2021
    Application Note 000: RAE Systems PID Overview
    1.1 MB
    7/15/2021
    Application Note 216: Using PIDs In Terrorist Chemical Attacks
    1.07 MB
    7/15/2021
    Application Note 228 - Facility and Venue Protection
    1.1 MB
    7/15/2021
    Application Note 211 - PIDs For Continuous Monitoring Of VOCs
    826.34 KB
    7/15/2021
    Measurement Of PGMEA Using Photoionization Detectors_12-11
    750.69 KB
    7/15/2021
    Application Note 203: PIDs As HazMat Response Tools
    1.26 MB
    7/15/2021
    Application Note 221: Using PIDs To Assess Exposure Risk In Unknown Environments
    964.88 KB
    7/15/2021
    Application Note 215: Gas Detection In The Marine Industries
    889.61 KB
    7/15/2021
    Application Note 205 - Measuring Heat Transfer Fluids With A PID
    831.7 KB
    7/15/2021
    Part Number
    Description
    Leaf Category
    Thumbnail
    Add to list