컴퓨터 및 워크스테이션 구성
Single-phase UPS Module 230 VAC 19 inch installation (2 HE) / desktop unit
Modern, flexible, efficient and microcontroller managed 230VAC online UPS for constant uninterruptible power supply of critical loads such as workstation or server of the nurse call system.
Please sign in to access more documents
Once signed in, you may be able to access additional documents for your account.
Overview
- Brand
- Honeywell
Electrical Specifications
- Power consumption (W)
- 90
- Output voltage (V AC)
- 230
Operating Characteristics
- Storage Temperature
- -40 to 85°C
- Air humidity
- < 20 %
Technical Specifications
- Technical Data
- Autonomy Time At 75% Load: 8 Min
- Battery Replacement Hot-Swap: Yes
- Connection Input: IEC C14 Output
- Efficiency: Typically 90%
- Input Voltage: Range Of 180-240 V AC 45-65 Hz
- Max. Output Current (Per Phase): 3.9A
- Number of Batteries: 3X7 Ah
- Output Power: 0.9KW
- Power Dissipation At 100% Load: 90 W (230 V AC)
- Recommended Circuit Breaker: 16A (B,C) (Charact.)
- Required Cooling Air Volume: 50M³
- Voltage: 230 V AC +/- 1%
- Interface
- RS232
Dimensions & Weight
- Weight (kg)
- 12
- Dimensions
- W: 440 mm H: 88 mm D: 405 mm
Applications & Compatibility
- Application
- Workstation or Server of the Nurse Call System
Overview
- Brand
- Honeywell
Electrical Specifications
- Power consumption (W)
- 90
- Output voltage (V AC)
- 230
Operating Characteristics
- Storage Temperature
- -40 to 85°C
- Air humidity
- < 20 %
Technical Specifications
- Technical Data
- Autonomy Time At 75% Load: 8 Min
- Battery Replacement Hot-Swap: Yes
- Connection Input: IEC C14 Output
- Efficiency: Typically 90%
- Input Voltage: Range Of 180-240 V AC 45-65 Hz
- Max. Output Current (Per Phase): 3.9A
- Number of Batteries: 3X7 Ah
- Output Power: 0.9KW
- Power Dissipation At 100% Load: 90 W (230 V AC)
- Recommended Circuit Breaker: 16A (B,C) (Charact.)
- Required Cooling Air Volume: 50M³
- Voltage: 230 V AC +/- 1%
- Interface
- RS232
Dimensions & Weight
- Weight (kg)
- 12
- Dimensions
- W: 440 mm H: 88 mm D: 405 mm
Applications & Compatibility
- Application
- Workstation or Server of the Nurse Call System
- Brand : Honeywell
- Power consumption (W) : 90
- Output voltage (V AC) : 230
- Storage Temperature : -40 to 85°C
- Technical Data : Autonomy Time At 75% Load: 8 Min|Battery Replacement Hot-Swap: Yes|Connection Input: IEC C14 Output|Efficiency: Typically 90%|Input Voltage: Range Of 180-240 V AC 45-65 Hz|Max. Output Current (Per Phase): 3.9A|Number of Batteries: 3X7 Ah|Output Power: 0.9KW|Power Dissipation At 100% Load: 90 W (230 V AC)|Recommended Circuit Breaker: 16A (B,C) (Charact.)|Required Cooling Air Volume: 50M³|Voltage: 230 V AC +/- 1%
- Air humidity : < 20 %
- Weight (kg) : 12
- Application : Workstation or Server of the Nurse Call System
- Dimensions : W: 440 mm H: 88 mm D: 405 mm
- Interface : RS232
제발 귀하의 계정을 기반으로 구매 가능한 부품 번호를 보려면 로그인하세요 로그인