/content/sps/it/it/search-results.html
    Questo sito sarà sottoposto a manutenzione programmata. Ti ringraziamo per la tua pazienza durante questo periodo.
    Systeemupdate bezig: Questo sito è programmato per una manutenzione pianificata domenica 17 maggio dalle 01:00 EST alle 11:00 EST (domenica 17 maggio dalle 05:00 UTC alle 15:00 PM UTC). Apprezziamo la vostra pazienza durante questo periodo.

    central components

    89954R5 Single Phase Power Supply Unit 24 V DC (10 A)

    Single-phase power supply unit (10 A) for the constant DC power supply of the call system in accordance with DIN VDE 0834-1: 2016-06, fulfilment of EN60601-1, 2xMOPP.

    Panoramica

    Part Number: 89954R5

    Single-phase power supply unit (10 A) for the constant DC power supply of the call system in accordance with DIN VDE 0834-1: 2016-06, fulfilment of EN60601-1, 2xMOPP. UL/CSA 60601-1 (E213214) certified. Very compact design due to fully-integrated primary-clocked switching technology. Parallel-switchable and series-switchable for flexible power supply of the call system and its components. Voltage range adjustable, for adaptation to local requirements. DC-OK-Signal (LED/relay) for further interference processing in accordance with DIN VDE 0834-1: 2016-06. Fitted with push-in connectors for simple wiring (max. 2.5 mm2). Suitable for top-hat rail mounting in the sub-distribution.

    Features
    Connectors output:
    • Push-In, max 2.5 mm2
    • earth leakage current:
    Signalling DC-OK:
    • Uout > 21,5 V DC (LED)
    • Uout > 21,5 V (typ.) max. 30 V/1A (relay)
    Recommended circuit breaker:
    • 10 A (characteristic B/C)
    Switch-on current limitation:
    • < 30 A, NTC
    Additional information

    IEC 60364-4-41 (DIN VDE 0100-410).

    SELV: EN 60601-1, 2xMOPP.

    EN 61558-1 /-2-16, EN 60950-1.

    AAMI/ANSI ES 60601-1: 2005.

    CSA C22.2 No. 60601-1 (2008).

    EMC: EN 61204-3.

    IEC 60601-1-2.

    CE: in accordance with 2014/30/EU and 2014/35/EU.

    UL: UL/CSA 60601-1 (E213214).

    Specifiche

    Operating Characteristics

    • Ambient Temperature
      • -25 to 70°C
    • Storage Temperature
      • -40 to 85°C

    Dimensions & Weight

    • Weight (kg)
      • 1
    • Dimensions
      • W: 55 mm H: 127 mm D: 171 mm

    Electrical Specifications

    • Rated voltage (V AC)
      • 230
    • Rated current (A)
      • 1.24
    • Output Voltage
      • 23 to 28.5 VDC
    • Output Current
      • 10 A at 24 V (Continuous Load)

    Technical Specifications

    • Rated frequency
      • 50 Hz
    • Mounting
      • Top-Hat Rail Mounting

    Funzioni

    • Features & Benefits
      • Earth Leakage Current: Uout > 21.5 VDC (LED), Uout > 21.5 V (typ.) Max. 30 V/1 A (Relay), 10 A (Characteristic B/C), < 30 A, NTC
      • Max 2.5 mm²
      • Push-In

    Panoramica

    • Brand
      • Honeywell

    Applications & Compatibility

    • Application
      • Constant DC Power Supply of the Call System

    Altro

    • Industry
      • Healthcare

    Operating Characteristics

    • Ambient Temperature
      • -25 to 70°C
    • Storage Temperature
      • -40 to 85°C

    Dimensions & Weight

    • Weight (kg)
      • 1
    • Dimensions
      • W: 55 mm H: 127 mm D: 171 mm

    Electrical Specifications

    • Rated voltage (V AC)
      • 230
    • Rated current (A)
      • 1.24
    • Output Voltage
      • 23 to 28.5 VDC
    • Output Current
      • 10 A at 24 V (Continuous Load)

    Technical Specifications

    • Rated frequency
      • 50 Hz
    • Mounting
      • Top-Hat Rail Mounting

    Funzioni

    • Features & Benefits
      • Earth Leakage Current: Uout > 21.5 VDC (LED), Uout > 21.5 V (typ.) Max. 30 V/1 A (Relay), 10 A (Characteristic B/C), < 30 A, NTC
      • Max 2.5 mm²
      • Push-In

    Panoramica

    • Brand
      • Honeywell

    Applications & Compatibility

    • Application
      • Constant DC Power Supply of the Call System

    Altro

    • Industry
      • Healthcare
    • Ambient Temperature : -25 to 70°C
    • Weight (kg) : 1
    • Storage Temperature : -40 to 85°C
    • Rated voltage (V AC) : 230
    • Rated frequency : 50 Hz
    • Rated current (A) : 1.24
    • Output Voltage : 23 to 28.5 VDC
    • Output Current : 10 A at 24 V (Continuous Load)
    • Mounting : Top-Hat Rail Mounting
    • Industry : Healthcare
    • Features & Benefits : Earth Leakage Current: Uout > 21.5 VDC (LED), Uout > 21.5 V (typ.) Max. 30 V/1 A (Relay), 10 A (Characteristic B/C), < 30 A, NTC|Max 2.5 mm²|Push-In
    • Dimensions : W: 55 mm H: 127 mm D: 171 mm
    • Brand : Honeywell
    • Application : Constant DC Power Supply of the Call System
    Nome
    Descrizione
    Dimensione file
    Data
    Dimensione
    Nome
    Descrizione
    Dimensione file
    Data
    Dimensione

    Filters

    Product Number
    Part Number
    Compare
    Description
    Leaf Category
    Thumbnail
    Add to list
    89954R5
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-fire-72581b1-primaryimage
    89954R5
    https://honeywell.scene7.com/is/image/Honeywell65/hbt-fire-72581b1-primaryimage